No video

DIY 24V 14Ah Li-ion 18650 UPS Replacement battery

  Рет қаралды 1,728

FastFIX KS

FastFIX KS

Күн бұрын

Пікірлер: 16
@rogermcdonald1607
@rogermcdonald1607 2 жыл бұрын
Nice job sir! Now i understand why you made the spot welder. Very handy machine and it seem like it went pretty fast .👍🇺🇸Roger
@fastfixks
@fastfixks 2 жыл бұрын
Thank you very much my friend, I'm glad you like it. Always among the first to watch and comment, I really appreciate that. Great machine, trust me. One of the more useful projects I have done. The spot welder has just started working, there will be a lot of work for this machine.
@tinkeringtaylor3053
@tinkeringtaylor3053 2 жыл бұрын
excellent video FastFIX KS well done,you just need to design something for all your cables now 😆😆
@fastfixks
@fastfixks 2 жыл бұрын
Thank you for watching and commenting friend. I think, I could put these batteries in the computer and monitor and throw out all the cables they have. That would be the right solution. The angry machine is ready for that act ..... 😆😆😆😆😆😆😆😆😆😆😆😆😆😆
@ghulamshabbir5837
@ghulamshabbir5837 2 жыл бұрын
Your efert is very nice tks
@fastfixks
@fastfixks 2 жыл бұрын
Thank you very much for the kind words. I hope you have subscribed to the channel, I would really appreciate it. Greetings
@mctzr
@mctzr 5 ай бұрын
Thanks for sharing:) Is it last more than normal battery (12 v 9 a)?
@fastfixks
@fastfixks 5 ай бұрын
My pleasure, I hope the video was useful. It works much longer on lithium batteries than on ordinary lead batteries. In my case, it is 24V, but also the 12V option can be boosted with amps so that the battery lasts longer.
@maniksarkar577
@maniksarkar577 Жыл бұрын
২৪ ভোল্ট ২০ এ্যম্পিয়ার ব্যাটারের দাম কত
@kyleperkins4757
@kyleperkins4757 11 ай бұрын
Can you help me do this to my bigger ups I have plenty of extra new 18650 batteries I just wouldn’t know how to put them on correct series etc
@kyleperkins4757
@kyleperkins4757 11 ай бұрын
liebert gxt3 is the model UPS I am working with
@moqtadahasan5413
@moqtadahasan5413 2 жыл бұрын
Hey, buddy, I did just like you, and everything started to be okay, but after a while, about 6 to 8 hours, the ups go off, whether it's on electricity or during discharge, but it's normal after I separate the battery from the ups wire, and then I reconnect it, it starts working normally again, and I checked everything and everything seemed fine without problems. How do I solve this problem?
@fastfixks
@fastfixks 2 жыл бұрын
It is very difficult to explain something that cannot be seen live. But considering what you wrote, I would have a few tips to say what could be the cause of this problem. First one statement: UPS cannot work without batteries or cannot work with very bad batteries. Sure, you have a battery but I doubt this second part of the sentence. 1. In order for lithium batteries to work without problems, they must first be tested. You may have noticed that I have paper stuck to each battery with certain values ​​printed on it. The most important of these values ​​is mAh. Testing checks their condition. Over time, they lose their strength and capacity. So you can't group them by manufacturer's model or battery color, because they haven't been used up evenly. Not all batteries are the same power, some charge or discharge quickly and some slower. So you can't combine such batteries. Eg If you have a 2500mAh battery, you can't combine it with a battery of e.g. 1000mAh. There is a big difference. In this case, even the BMS cannot balance the charge or discharge. So charging the battery a bit which ultimately signals that the battery is bad. My working principle is not to make a difference of more than 400mAh and only if I use more batteries in parallel mode. If I use one or two batteries in parallel, then I don’t make a bigger difference than 200mAh. I must emphasize that I have a lot of batteries, so I can choose batteries that are almost the same capacity. So it might be a little easier for me to do something like this. 2. Another thing that might be a problem: The wires used for charging and discharging are thin (wire + and wire -). Stronger currents cannot pass through thin wires. They do not pass enough electricity, they do it slowly and the wires heat up a lot in that case. Both of these cases "send" a signal to the UPS that the batteries are bad or non-existent (now we return to the statement I mentioned in the text above). That's why UPS reacts by shutting down and staying in some "safe" mode. When you disconnect the wires on the battery, this mode is reset. I hope these tips will help you and that you will solve the problem. Greetings FastFIX
@moqtadahasan5413
@moqtadahasan5413 2 жыл бұрын
@@fastfixks Thank you my dear friend all these things have been taken care of in detail and by expert people in this field but at the beginning when I completed the battery I managed to test the duration of unloading and I put it in discharge until it ended I think that is the cause of the problem but I recharge it again and the voltage returned to its previous time which is 27 volts anyway thank you my dear friend for these fruitful advices and I will try to find a solution to this issue
@fastfixks
@fastfixks 2 жыл бұрын
@@moqtadahasan5413 You're welcome, I wish I could help more.
@Nuttavoot
@Nuttavoot Жыл бұрын
I have the same problem, it cause by the BMS shut off after the battery voltage dropped below the BMS shut off voltage, I have to disconnect the wires to the UPS. Maybe I will have to connect a switch instead.
18650 24v Ups Hack pt1 Build, Setup and Discharge Test
24:12
AveRage Joe
Рет қаралды 52 М.
Can a UPS use li-ion batteries
14:04
Leaf Xpack
Рет қаралды 41 М.
👨‍🔧📐
00:43
Kan Andrey
Рет қаралды 10 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 14 МЛН
Building 24V/10Ah Li-Ion battery pack
21:17
Mcells Batteries
Рет қаралды 361 М.
Lithium-ion battery, How does it work?
10:38
Lesics
Рет қаралды 3,1 МЛН
Antique Drawknife  ||  Restoration
10:50
FastFIX KS
Рет қаралды 948
15 Differences between Lithium battery and Tubular Battery.
16:10
Smilinsun Solar Energies
Рет қаралды 19 М.
New SOK Battery! Lowest Price 48V Battery: $1,349 for 5kWh
7:47
DIY Solar Power with Will Prowse
Рет қаралды 195 М.
Battery 4.0: The Solid State Battery Revolution
14:35
Dr Ben Miles
Рет қаралды 431 М.
Rarely Seen Pliers. Restoration With Copper Plating
11:12
FastFIX KS
Рет қаралды 1,1 М.