How To Add Refrigerant / Freon To Your Window Air Conditioner R22 & 410a

  Рет қаралды 85,101

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

1/2" 5/8" Saddle Valve: amzn.to/3WjFttv
1/4" 5/16" 3/8" Saddle Valve: amzn.to/4cylZam
America's #1 Choice For Quality, Affordable HVAC Equipment: www.alpinehome...
All my favorite HVAC tools: www.amazon.com...
Do you own a service business and need a customer management software?
Housecall Pro is the BEST CRM for small businesses and can save you so much time with scheduling, onboarding new customers, sending estimates etc.
Use my link to get 50% off the first 2 months: housecallpro.p...
Join our channel membership to gain access to exclusive HVAC training videos AND x10 entries for our monthly giveaways!! NO PURCHASE NEEDED. Prizes are valued anywhere between $500-$2000!
Join here: / @diyhvacguy
IF YOU ARE IN NEED OF ONE ON ONE GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a low price of $400, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

Пікірлер: 150
@billiamc1969
@billiamc1969 3 ай бұрын
This is the BEST ac channel on KZbin...I have learned how to service all my units at home saving 1000s
@lindabullard1596
@lindabullard1596 3 ай бұрын
Yes, I have had such bad experiences from the AC company I bought my complete system from. Now I check with your videos and take care of my system myself. Thank you!!
@7x779
@7x779 3 ай бұрын
I have used those A1 and A2 to screw saddle valves for decades, and occasionally gone back even years later to follow up on them and I don't recall one of them ever leaking. However, local suppliers here shifted to another brand with three screws and defeating coming off at it add an angle, the name is called bullet in an orange box I forgot the brand but I have had those leaked and in some installations they won't fit well. The one shown in this video are the best ones to get I would avoid others
@Harry1s
@Harry1s 3 ай бұрын
I've been an AC tech for 35 years - I've never seen a bullet valve that did not leak. I highly recommend to never leave them installed. If you think the circuit is low I recommend: 1) remove the remaining freon. 2) find and repair the leak. 3) leak test. 4) add factory recommended charge. 5) test operations. One other thing I've found a lot of people that work on window units don't know is that a lot of them have condenser water slingers = a plastic scoop on the cond fan that slings the water from the evaporator on to the cond coil. This helps keep the cond/high pressure down. If this is not operating properly the unit will not cool properly.
@synowiecj
@synowiecj 3 ай бұрын
You are completely correct. Bullet valves are temporary. And refrigerant in these units is measured in ounces, over charged is good either way
@BradBennet-md4tv
@BradBennet-md4tv 2 ай бұрын
Your right. But all that your saying is not worth doing on a window unit. A cheap charge is a good go to before tossing it
@Red-Raider
@Red-Raider 2 ай бұрын
First off a new a/c unit is $200-$300. For a homeowner to do this will cost the charging adapter, the freon and the valve. Your close to $200 right there. What have you saved? You still need to uninstall, and reinstall. You could save time, effort and headache (if the valve fails over time) by just replacing it! If you already have all the equipment, then try it, otherwise not worth it imho
@JetSettingBotanist
@JetSettingBotanist 2 ай бұрын
So I got a fairly new (2019) GE window unit for free on the curb. I don’t have brazing skills, so I was thinking about adding a bullet valve to add refrigerant, and UV dye so I can find a leak. What are your thoughts on repairing a leak with something like JB Weld? I wouldn’t be selling the AC so I’m ok with a little bit of risk, remember, the unit was free
@jalixvarietytv7849
@jalixvarietytv7849 2 ай бұрын
I agree with you. I also do the same as a technician.
@illiniwood
@illiniwood 3 ай бұрын
I think I'm going to learn to braze. I'm starting to believe it's a skill that's worth its weight in gold.
@mikafoxx2717
@mikafoxx2717 2 ай бұрын
Silver, actually.
@grundyb
@grundyb 3 ай бұрын
Neat! I have the exact same gauge set as you. I don’t do HVAC work every day so this year I needed a little Freon and it worked perfectly. My condenser coil was so dirty that maybe 1/3 of the air could pass over the coils. I added Freon until I was about 38 degrees F. I added a tap years ago and added Freon to my mother in law’s refrigerator but the compressor was just not able to keep up and we needed to replace it. Refrigerators are easy to know when they aren’t working properly when the ice cubes can’t be made.
@barnowl6807
@barnowl6807 Ай бұрын
One VERY important observation. The condenser coils are almost invariably installed with the lower part of their copper coils resting on the metal of the bottom pan. When water is present there - - will - - be electrolytic corrosion of both metals. Usually, the copper will develop tiny pin holes and slowly leak the refrigerant. This causes the temperature out of the evaporator to slowly rise over months (Cooling capacity has been reduced) until the ice forms on the return line and you have no cooling. This happened to me on three window units over the years before I realized what was going on. On all new window units I remove the cover, add a 1/8 inch thick piece of plastic between the coils and the metal bottom. No more leaks after 7 years. This can also occur on the evaporator coils if they are touching the pan. Same cure.
@davearonow65
@davearonow65 3 күн бұрын
Awesome advice. Thank you.
@AverageJoesracingteam
@AverageJoesracingteam 3 ай бұрын
I have learned so much from this channel. Thanks for sharing your knowledge
@TheRealRenn
@TheRealRenn 3 ай бұрын
You find the coolest products. Thank you for sharing.
@jameswest3890
@jameswest3890 3 ай бұрын
Always great information Thank you. So many HVAC guys think there brain surgeons. I got a 608 just to work on my own equipment. Any half wit can pass the 608 test.
@Notdave29
@Notdave29 3 ай бұрын
lol just don’t forget that the 608 test has nothing to do with being an HVAC tech.
@stevendevilliers471
@stevendevilliers471 3 ай бұрын
Thank you. All your explanations are brilliant
@7x779
@7x779 3 ай бұрын
Have you ever checked your infrared thermometer against a real physical thermometer? I have three different ones and I pretty much gave up on using them professionally because they're so inaccurate and inconsistent. And when you're on a job with multiple people waiting, some of them in emergency situations, you don't have time for screw-ups and errors and confusion when you point the thing at something and it reads one thing and then you point it again and it reads differently. You need accurate readings. I get it though, all of us are lazy and would much rather point something in a register then get up and sometimes need a ladder to stick an actual thermometer in there but at least you know you're getting accurate reading Also a lot of people don't even understand that the infrared does not read the pinpoint that the laser is pointing to, but rather it's an ever-expanding funnel shape that measures a bigger and bigger Circle the farther the object is a way that you're measuring That should be taught to your viewers as well
@MariaRochetti-w5k
@MariaRochetti-w5k Ай бұрын
Very informational thank you for explaining how to do this correctly
@7x779
@7x779 3 ай бұрын
Also, a very important piece of information missing, was that the temperature of the intake air to the evaporator coil was not measured in either before or after. I get it, it did get colder after adding freon of course But for the sake of accuracy, the most important thing is how much the temperature drop or split changed, since we don't know if the intake air temperature changed during this comparison. I just charged very expensive portable Runway air conditioner that keeps an emergency helicopter cool when sitting outside in 118° and blazing sun I had to charge it in actual operating conditions, so I brought it outside the hanger hooked everything up put my thermometers everywhere and started charging, and one of the staff members just opened a regular door several feet away from where I was working and I noticed it through all the readings off. I wondered why my ambient dropped 10°, if I went by my emotions and subjective feeling, it still felt hot outside and I could have ignored it which would have made me ignorant of the facts and what was happening. Just buy the guy opening the door it let enough cool air out of the hanger into the outdoors where I was working, that some of it was getting sucked into the condenser, so I would not have been charging it in actual conditions. Then I could have left and they bring it out to the helicopter and it goes off on high head. I understand this is not a concern when you're making casual videos for KZbin, but when you're actually out there on the line in the most extreme conditions and circumstances were people absolutely depend on you, you can't afford to be as casual and lackadaisical with your instruments and measuring methods
@frankdeleon9293
@frankdeleon9293 Ай бұрын
Pretty good and informative. Most techs I have asked about it say to replace the unit.
@katisugarbaker7349
@katisugarbaker7349 3 ай бұрын
To figure out the size of the line tap valve, you could also use that math you said you never needed in adulthood and just measure the line circumference. Then divide by pi. Some calcs have a pi button, so you can get a more accurate number or you can just use 3:141592. I’m not a handyman, though, so I’d consider the thickness of the pipe itself, too. Hopefully the AC unit specs would tell you. But do they differ that much from unit to unit?
@thatguy3468
@thatguy3468 3 ай бұрын
Can use some help advice. My house has 3 4 ton central systems. All except one put out about 54 degree air, the one I’ve been concerned about only puts out at best 68 degree air. The condenser is clean, the refrigerant pressure is where it needs to be. The refrigerant I believe is 410a. The system in question cannot keep up when outside temperatures go above 95. Needless to say it’s been costing a fortune to keep the rooms on that system cool.
@MrAcacio
@MrAcacio 2 ай бұрын
This is a great video. Thank you so much for teaching. I would like to suggest making a video on how to soldering Cooper ac pipes. May God bless you. 1000 Thanks
@jazzfreek54
@jazzfreek54 3 ай бұрын
Perfect timing! Same operation with a dehumidifier I assume. Your info is amazing! Thank you... again!
@TechnoAlliance1
@TechnoAlliance1 3 ай бұрын
Curved brim finally 👍 Just playing. Love the channel man.
@cesarvazquez4658
@cesarvazquez4658 Ай бұрын
Excellent video. Thank you 👍🏻
@ChavezDIY
@ChavezDIY 2 ай бұрын
That was awesome. I didn't know this was possible. Would adding some nylog to the saddle valve help it seal better?
@MrHVACguy71
@MrHVACguy71 3 ай бұрын
Did the wall a/c come from the factory low on refrigerant or is there a leak somewhere? I know once a piercing valve is installed they can seep at that location over time
@izb1678
@izb1678 3 ай бұрын
This guy doesn’t seem to totally understand the consequences of some of the things he does
@jkmarshall3553
@jkmarshall3553 3 ай бұрын
Then just add a bit more in two years...otherwise you need to trash that unit and buy another.
@borshardsd
@borshardsd 3 ай бұрын
Oh yeah lol piercing valves are for temporary use. Hilarious. I remember one of our guys videos [mostly this guy is 100%] where he had the general public vacuum out there condensate lines but never told them to prime the trap after, negating the point of the trap. But what do I know =D
@D2O2
@D2O2 3 ай бұрын
Yes, everytime I have used a piercing valve it because the definite leak point, if not immediately, it did begin to leak shortly. I belive the vibration of the lines causes them to loosen and leak.
@skasev
@skasev 3 ай бұрын
Stop asking questions and top her up dude
@scoobtoober2975
@scoobtoober2975 3 ай бұрын
We'd love your thoughts on the newer heatpump window units. Midea who makes the aciq stuff. $400 for heating and cooling. heat that is way more efficient than electric space heater. tech ingredients here on youtube did a demo. but that was with an old unit. He said he's going to provide some improvements too, soon. Love you both. my aciq 2 ton inverter is sweet, even with colorado 100 deg day right now
@superspeeder
@superspeeder 3 ай бұрын
Could you do a deep dive video on how to read gauges? I’m sure many would appreciate it!!!
@josephduncan8090
@josephduncan8090 Ай бұрын
this why I'm an automotive tech. what am saying I have different trades in one vehicle. (hopefully never plumbing)
@s2sailingfree
@s2sailingfree 3 ай бұрын
Love your content, thank you for sharing. Could you please make a video performing the same service on an RV roof top AC unit. These units are notoriously expensive and it’s almost impossible to find anyone to service or recharge them. Additionally is there a sealant that can be safely added to repair small leaks? Thank you 🙏🏼
@jamesszalla4274
@jamesszalla4274 Ай бұрын
I’m a retired HVAC technician. You don’t change to above 32 on the temperature scale. You use superheat or subcool to change. The way you’re doing it, you can end up being overcharged or undercharged.
@RobtTa
@RobtTa 3 ай бұрын
By far one of the best videos I have seen in a long time, Thanks!!
@terrillfloyd
@terrillfloyd 2 ай бұрын
Very good video I have about 8 window units that aren't cooling.I just took them out and buy another one now i'm not confix them
@1951Roy
@1951Roy 2 ай бұрын
Can you make a video on what an A/C company does when they come out to the house for yearly maintenance check. Thanks for sharing.
@kylelaw7210
@kylelaw7210 3 ай бұрын
What gauges are vacuum pump would you recommend for a DIY person that wants to be able to install car (134a) and home AC (410A)? I don’t want the cheapest junk possible but also wouldn’t need top of the line equipment.
@qinlingzhou8815
@qinlingzhou8815 2 ай бұрын
R410A is very expensive. This method can be used to fix dehumidifier too if using R130A. :)
@23x31
@23x31 3 ай бұрын
These piercing valves do work although are hit and miss with leaking. They're used quite often on refrigerators that are low on gas.
@rogermartin404
@rogermartin404 Ай бұрын
I've been putting R134 car refridgent in mine for 15 years... damn thing shoots out snowflakes it gets so cold.
@TOOL_TECHNICAL
@TOOL_TECHNICAL 15 күн бұрын
if your ac is R134 rated then it's fine. car or not it's all R134. Now R12, R22 to 410 or R134 is different. swapping refrigerant types may shorten your system's lifespan
@Bowhunters6go8xz6x
@Bowhunters6go8xz6x 3 ай бұрын
Awesome video for servicing window AC units, you could see the frost was gone from the tubing after you got done. Also its a good idea to wear safety glasses when doing this or any work around freon, I know a guy that is blinded in one eye today as he serviced his own AC many years ago and some freon under pressure sprayed into his face and hit him in one eye.
@denniszhaunerchyk6191
@denniszhaunerchyk6191 3 ай бұрын
Nice video. Thank you for the review!
@9to5techs
@9to5techs 2 ай бұрын
I am in a mobile home and was wondering if you could help. Backstory: The unit started to freeze up at 64F inside house, thermostat set for 60F, 85 outside (i like it 🥶 ❄️ at night). I was using standard 3m merv 5 pleated filters on the A-coil( but tech said the evaporator coil was getting the cardboard/filter pleats that the filters are made of wet makeing more restrictoed air and to use those metal mesh A-coil filters 16 x 25) And merv 1 on return door(20in x 30in)= merv 6 Total. Those metal mesh A-coil filters are not that good at catching dust is their any other filters I could use on the A-coil evaporator without getting the paper pleated filters wet. The company that installed the unit put a R-410A 5 ton A-coil evaporator with a 3.5 piston in A-coil then put a 3.5 ton condenser outside. The air intake is a 20 in x 30 in with blower (4 speed up to 4 ton HP/AC, 2.9 FLA, 1/3 horse power@ high speed 1460
@TSGEnt
@TSGEnt 3 ай бұрын
Great tips! Great information! Thank you! Ok, the elephant in the room is; How does one get an EPA certificate?
@colinnwn
@colinnwn 3 ай бұрын
You can study and take the course online. He's got other videos about how to do it.
@bluejay713
@bluejay713 3 ай бұрын
Hi i used skillcat to get mine he has a video on that.
@TSGEnt
@TSGEnt 2 ай бұрын
@@bluejay713 Thank you.
@TSGEnt
@TSGEnt 2 ай бұрын
@@colinnwn Great. Thank you.
@JustinMiales
@JustinMiales 2 ай бұрын
Arizona used swamp coolers they work great if it didn't rain, we used to get the afternoon thunderstorms in monsoon season and then the sun would come out and they're worthless than
@jscott5042
@jscott5042 2 ай бұрын
Great video. Thanks!
@MrInkotime
@MrInkotime 3 ай бұрын
To install the saddle valve, don't you lose the refrigerant inside. How will you recover the refrigerant before?
@GhostReaper2043
@GhostReaper2043 3 ай бұрын
you wont loose the refrigerant until you screw in the cap all the way in then it will pierce the line.
@MrInkotime
@MrInkotime 3 ай бұрын
@@GhostReaper2043 I meant the other valve that was brazed.
@illiniwood
@illiniwood 3 ай бұрын
I'm no HVAC guy, but I'd first install the piercing valve, recover the refrigerant, Remove the piercing valve, then braze on the other saddle valve in its place. Like I said, I'm no HVAC guy, but that's what I'd do. Please correct me if I'm wrong. We're all here to learn.
@ChavezDIY
@ChavezDIY 2 ай бұрын
Yes, if you want to braze on the saddle valve you will need to remove the refrigerant. HVAC techs have the equipment to recover the refrigerant so it doesn't get released into the atmosphere.
@gnvdude
@gnvdude 11 күн бұрын
what about refrigerators? do the same rules apply ? if the coils are freezing up and the defrost cycles are working can you test refrigerant pressures to see if it needs more?
@JustinMiales
@JustinMiales 2 ай бұрын
That's really cool no soldering, cuz I suck
@boblevey
@boblevey 2 ай бұрын
Nice video! Thanks !!!
@jdthewelder8308
@jdthewelder8308 3 ай бұрын
Great vid but what normal person has all that gear. Is there a diy kit like there is for auto ac jobs?
@Dicofol1
@Dicofol1 2 ай бұрын
What is your opinion of the PRO-FIT Quick Connect Fittings from Rectorseal? Looks like a Sharkbite version for HVAC, looks safer to use with R290.
@american_patriot6218
@american_patriot6218 2 ай бұрын
I have a 4-year-old system, and the service tech said there is a leak in the coil. He said I will have to replace the coil, and the R410A would be $700, and the labor would be almost $3000. Is this normal? Can R410A with stop leak be used instead?
@rogermartin404
@rogermartin404 Ай бұрын
Guy was trying to rip you off.
@fishlanding2
@fishlanding2 3 ай бұрын
what do you think about the aluminum framed reusable electrostatic filters ?
@salvadorcastillo1539
@salvadorcastillo1539 3 ай бұрын
Thank a lot of for the video very good and helpful information......
@mrj1902
@mrj1902 27 күн бұрын
Can you put a condensate tablet in your window ac unit ?
@rollandjoeseph
@rollandjoeseph 3 ай бұрын
Great tip if you have an EPA certificate i guess?
@natersalad889
@natersalad889 3 ай бұрын
Quick online test and you can have one too....
@lunacyworks
@lunacyworks Ай бұрын
can you post the actual link to valve you used in the video, the listed valves on amazon listed are not the same.
@jkmarshall3553
@jkmarshall3553 3 ай бұрын
Great stuff! Thanks!
@rdlockrey
@rdlockrey 3 ай бұрын
awesome video, thank you so much!...
@donc461
@donc461 2 ай бұрын
Not sure why you installed your own saddle valve . The one below yours looks usable .What am I missing.?
@Time-Trvlr
@Time-Trvlr 3 ай бұрын
Would you benefit cleaning the line before installing the saddle unit?
@GhostReaper2043
@GhostReaper2043 3 ай бұрын
to get a good seal I'd would think so but I dont think it would matter though
@TheDopalgangr
@TheDopalgangr 3 ай бұрын
Yes you would and he fails to mention that although if you watch the video closely the line magically goes from dirty to clean when he’s installing it so I guess he forgot that step then went back and did it during an edit.
@blackout7615
@blackout7615 3 ай бұрын
If im getting 35 to 40 degree air exiting my mini split and air entering is 70-75. Is that cold enough?
@phoneblaster
@phoneblaster 2 ай бұрын
...if I can ask a question please. You turned the freon cylinder upside down. If you can explain why it will be helpful. I am new to all this. Thanks
@diyhvacguy
@diyhvacguy 2 ай бұрын
So that you get liquid refrigerant
@phoneblaster
@phoneblaster 2 ай бұрын
@@diyhvacguy ...then you would only fill the side that is 'liquid' ? Is this correct. Thanks
@donc461
@donc461 2 ай бұрын
410 is a mixture of two gases, if your only take the vapor off the top of the liquid you will not get the proper ratio of the two gases.So you invert the tank to get liquid and then add it slowly to avoid slugging the compresor with liquid.
@davidyummus6259
@davidyummus6259 3 ай бұрын
I have an old Chrysler Wall A/C unit, probably early 90's,... Hosed the rear coil out at the end of last summer, ran fine now will turn on but won't make cool air. What did I do wrong ? lol.
@annettesurfer
@annettesurfer 3 ай бұрын
Reminds me of the time I hosed out a couple A/C window units and it wasn’t long before I had to replace the fan bearings. Easy and cheap but I learned not to do that again.
@erikyoung5139
@erikyoung5139 3 ай бұрын
Is it possible to use staybright with these brazed ports?
@albundy3696
@albundy3696 Ай бұрын
piercing valve may install to check out if there any Gas Left in the Unit , if some you can use that valve to remove how much then when gas out you can install permanent valve , unit what I seen in video already have valve on same pipe , why install second One ?
@brandog1734
@brandog1734 2 ай бұрын
I prefer to braze them on.
@christhinksit
@christhinksit 3 ай бұрын
First Channel I have ever wanted to join and even after watching a video on it still cant find the join button.
@googacct
@googacct 3 ай бұрын
A few years ago I was given a window AC unit that had lost its charge. I tried using one of those piercing valves and instead of piercing the copper line, it crushed it. I am not sure why that happened. I did not have any time to mess with it beyond that, so the AC unit eventually ended on the curb for big trash pickup day.
@MrNorthstar50
@MrNorthstar50 3 ай бұрын
I have never used a piercing valve on AC, but I have have replaced many of the piercing valves that are leaking when they were used on plumbing. The rubber seals deteriorate in time or they have crushed the copper like your has. I would never use one on an AC .
@borshardsd
@borshardsd 3 ай бұрын
​@@MrNorthstar50if we use them in the field it's temporary. I agree with you fam
@MrNorthstar50
@MrNorthstar50 3 ай бұрын
@@borshardsd I knew you were just doing it for a demonstration, you always try to do things the right way. I just thought some would think could be a permanent fix, I always like watching your videos.
@tyronehowell3909
@tyronehowell3909 2 ай бұрын
can you add a small can 134a from auto zone
@jimhoward1655
@jimhoward1655 3 ай бұрын
Did i miss the ambient air temperature??
@northernliving2387
@northernliving2387 2 ай бұрын
How much freon dose a window A/C unit hold
@skyscraper37
@skyscraper37 3 ай бұрын
I suppose this would work for a refrigerator too
@GhostReaper2043
@GhostReaper2043 3 ай бұрын
yep
@Kevin-mm6xm
@Kevin-mm6xm 3 ай бұрын
Surprisingly most of what he said was correct. The problem is finding and repairing the leak which most probably is in the condenser or evaporator coil. The unit was fixed once already as can be seen by the brazed in Schrader valve (brass cap). Those saddle valves are known to leak over time also. For a DIY with no experience in HVAC, by the time you get R410a, manifold gauge, valves etc, just to have it leak again, you are way better off just buying a new window unit then constantly charging at $100.00 or more a pop each time it leaks out.
@jamesorellana9930
@jamesorellana9930 22 күн бұрын
I charged my one but goes to zero psi, it does not go to vacuum, i add refrigerant to it but after it still goes to zero psi. Any idea that can help me out?
@johnverdin6600
@johnverdin6600 2 ай бұрын
How to fix the heater on a two year old GE window unit
@DaleJacobs-d1i
@DaleJacobs-d1i Ай бұрын
Huge fines..
@kitchenenterprise3787
@kitchenenterprise3787 2 ай бұрын
👏👏👏👏🇺🇸😎
@makienaral1546
@makienaral1546 Ай бұрын
It doesn't leak ?
@Dave-nm3xc
@Dave-nm3xc 3 ай бұрын
You are awesome.
@Igotstaknowit
@Igotstaknowit 2 ай бұрын
Amazing it is legal to buy r-22 online for about $30/lb if you are unlicensed and state you will not use it yourself and only plan on selling it to someone who is licensed. Like who is going to send the r-22 police to your house? What should be illegal is the thousands of dollars companies charge for a refill.
@bluejay713
@bluejay713 2 ай бұрын
Hi only if your Epa 608 certified its not cheap 30 pound jug cost $845 from ability refrigerants they sale a recharge kit that has 2 pounds for $153 you can use skillcat to take the epa 608 test thats it thats how i got mine.
@JustinMiales
@JustinMiales 2 ай бұрын
What happens when you don't have the ports to add the stuff
@brucey5585
@brucey5585 3 ай бұрын
It's pretty useless for non certified technician. Also, if you need to add refrigerant, then it must be leaking somewhere. I have a 20 year old window a/c and never needed refrigerant. It is cheaper to just buy a new window a/c.
@seangriffon6502
@seangriffon6502 3 ай бұрын
Yep, and all ac units today use a midly flamable R 32 A refrigerant. They have been using this refrigerant since 2016 so this unit this guy is servicing has to be way older thsn 2 yrs old.
@BillyBobDingledorf
@BillyBobDingledorf 2 ай бұрын
A two year old AC unit is already low on coolant? That's the real issue.
@joeearley3351
@joeearley3351 2 ай бұрын
Why does it leak? If it was made right it shouldn't leak for 40 years.
@skasev
@skasev 3 ай бұрын
I added 6 pounds to mine and still don’t work
@GeorgeWashingtonLaserMusket
@GeorgeWashingtonLaserMusket 3 ай бұрын
Uh I'm deeply concerned about this video. You're seriously advising people to use a tap that isn't soldered on there? That's going to cause more leaks... HVAC isn't something where pressure fit is viable, every connection should be soldered/welded. This is disappointing, that tap would be legitimate for once time use to extract gas if you then seal/cut and replace the damaged pipe that'd be fine. Is that even rated for use in the free world? It looks like something that wouldn't even be legal in China or India, remember just because you can buy it doesn't make it legal. Also in the USA you have to be licensed to do this. I didn't hear you say that as a legal disclaimer/warning.
@GhostReaper2043
@GhostReaper2043 3 ай бұрын
Anyone could do this as long as you know what your doing and are using proper equipment. Plus if you read the video description notes you would find his disclaimer/warning next time read the video notes not that hard to find. Yes, he is a licened HVAC Contractor in the state of Utah. Copied from the video notes he stated.... "⚠ Disclaimer: This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information."
@skasev
@skasev 3 ай бұрын
Qualified maybe but not to teach
@silat13
@silat13 3 ай бұрын
Are you saying he's wrong and what he said? If so could you write the correction in your reply?
@Watchyn_Yarwood
@Watchyn_Yarwood 3 ай бұрын
@@silat13 Better yet, document your certifications and experience to make such a statement. Everyone has a keyboard and can type anything they wish. Actions speak much louder than words.
@Notdave29
@Notdave29 3 ай бұрын
We just throw them away and buy a new one. If I have to work on it for an hour and buy a part then it’s cheaper to just replace it. Same for refrigerators. I only work on laboratory/medical or large commercial refrigerators. Anything smaller is almost never worth the time and money.
@xSuperManW3x
@xSuperManW3x 3 ай бұрын
This is all completely pointless LOL.... These units are DESIGNED TO FAIL after the 1st season/year When you buy a new a/c if it does not have a drain, drill a couple drain holes........ These aircons are made to pool water and then spray that on the coil, well it certainly increases the efficiency rating so they can sell them for a higher $$$.... but in reality this increased efficiently is almost meaningless in reality........ All this does is spray outside air and gunk and clog up the outside coil to the point that the ac fails because the outside coil is so clogged that air can no longer pass through it .......... well saving 25$ in a year sounds good..... until you realize that after a year you have to pay 500$ to replace you broken A/C......... BUT IN REALITY this a/c design builds up pools of stagnant water and gunk which it then sprays on the coil which then clogs up the outside coil and essentially makes the aircon blow up after a single years use... certainly having a few drains slightly decrease efficiently, but the gains outweigh the detriments...... With a few drains the water never builds up and becomes gunky, and this dirty sticky water is not sprayed onto the outside coil just to clog it up and make the a/c fail after a single season........................ I am honestly surprised soo many ppl defend the anti hole drillers here... LOL
@tellittotheworld857
@tellittotheworld857 3 ай бұрын
Or just throw it out and get a new one.😮
@nonyaanon6801
@nonyaanon6801 2 ай бұрын
Know it all video, damaging trade value type.
@donaldmartinez5252
@donaldmartinez5252 Ай бұрын
Lol unless you have a license to buy these refrigerants 22 and 400 hundred series can not be sold to you. How misleading, yes easy to add refrigerant impossible to buy. This video wast of time. I know I work in the field.
@jimmyk.9437
@jimmyk.9437 Ай бұрын
It’s not that hard to do the online test for your certification. Really helps in the long run to have it anyway.
@stevenjernaginii7748
@stevenjernaginii7748 Ай бұрын
You'd think they would have mentioned that before WASTING 10 OF 12 MINUTES of my life!
@paulbryant68
@paulbryant68 Ай бұрын
go to site he mentioned…you can buy it with out a license. check a box and order. i did it last year with no license. i learned that from one of his earlier videos. not sure why he didn’t say it this time? must have gotten heat from hvac techs???
@imeyers01
@imeyers01 15 күн бұрын
even so, most window A/c units don't have the service port for a professional to add refrigerant. paying $15 for the Tap Valve and however much it'll cost for the actual refrigerant is still way more affordable than buying an entirely new unit. especially if you're dumb like me who damaged it in a very repairable way, who now just needs it to be filled. taking the unit to a pro to fill is still way cheaper
@eli84360
@eli84360 6 күн бұрын
? I can go online and buy R410a if I want to right now. There's no regulation on who can be sold to. The government does want you to be certified to service your own cars AC system though 🙄
@worlddemize
@worlddemize 3 ай бұрын
what a dork .
@izb1678
@izb1678 3 ай бұрын
Why would you add another one just another point to leak from
@jkmarshall3553
@jkmarshall3553 3 ай бұрын
Dude!
@mikemike4415
@mikemike4415 3 ай бұрын
Because that's probably the only demo unit he had on hand. He stated someone else installed the 1st one. Had to install the saddle one to make the video.
@diyhvacguy
@diyhvacguy 3 ай бұрын
For demonstration purposes
@JustinMiales
@JustinMiales 2 ай бұрын
Dirt and dust
@DaleJacobs-d1i
@DaleJacobs-d1i Ай бұрын
Piercing valves are Only temporary!!! Is illegal to do this without an epa license...
@therealdheel8177
@therealdheel8177 2 ай бұрын
Go ahead and put gauges on a unit without that EPA 608. Take pictures and send them to me. So, i can turn you in and make that money. An piercing valves are garbage. It is going to leak again in the future. Get a schrade valve with a copper stem. Burn a hole in the copper, and braze on the schrader valve
@brandog1734
@brandog1734 2 ай бұрын
I prefer to braze them on.
How To Add Refrigerant To Air Conditioner
22:01
Word of Advice TV
Рет қаралды 1,8 МЛН
Soldering An HVAC Line Set Using Staybrite 8.  STRONGER THAN BRAZING!
29:04
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 10 МЛН
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 50 МЛН
Миллионер | 2 - серия
16:04
Million Show
Рет қаралды 1,2 МЛН
Seja Gentil com os Pequenos Animais 😿
00:20
Los Wagners
Рет қаралды 21 МЛН
The COLDEST And QUIETEST AC Unit Ever Made!  Still Use Your Window!
12:02
The Mini Split - REINVENTED.
31:23
The DIY HVAC Guy
Рет қаралды 390 М.
Clean Window AC the LAZY (but still effective) way!
7:48
Handyman Hertz
Рет қаралды 1,7 МЛН
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 387 М.
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 553 М.
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 992 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
3 Things HVAC Contractors Don't Want You To Know About.
13:17
The DIY HVAC Guy
Рет қаралды 2,3 МЛН
How To Refill R22 AC With Subcooling Method
14:30
Word of Advice TV
Рет қаралды 377 М.
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 10 МЛН