Replacing Your Gas Furnace Is Easier Than You'd Think.

  Рет қаралды 316,465

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

All my favorite HVAC tools: www.amazon.com/shop/thediyhva...
Manometer: amzn.to/3jcQXxS
Hose adapter: amzn.to/3V645SE
#1 Source for HVAC equipment: hvacdirect.com
Use my discount code X17AYSRVNGN8 for an extra 3% off!
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a small fee of $200, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/qYEa1J0knccjlwe...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com/@diy.hvac.guy?...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
00:00 Introduction
00:30 Shutting off the natural gas
01:40 Shutting off the electricity
03:21 Removing gas line
04:50 Installing new gas valve
08:04 Removing electrical box
12:10 Disconnecting return plenum
14:17 Disconnecting supply plenum
17:24 Removing old furnace
20:21 Cutting hole in furnace for return air
22:47 Installing new gas line
28:00 New electrical installation
31:29 Ductwork transition
41:21 Main power and electrical switch
46:08 Reinstalling thermostat wires
48:43 Checking gas pressure
52:07 Checking static pressure
56:16 Checking temp rise

Пікірлер: 809
@roystorts6495
@roystorts6495 Жыл бұрын
I have seen all of your furnace videos and this is the best install so far. I like that you are growing and getting better at sheet metal. I have been a service tech for some time now and would not install my own ac and furnace because I’m too much about aesthetics but I will do installs on the side.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thanks so much for the feedback! Always trying to improve and I’m excited for the next one! Cheers bro
@damon6852
@damon6852 6 ай бұрын
Won’t install your own equipment because of…wow, I just don’t see the logic in that, but whatever…
@brokeminer475
@brokeminer475 9 ай бұрын
Been 15 years since I last installed my furnace and AC unit. Back then it was difficult to even buy a furnace or ac unit because market was locked up. Now it’s way easier to get. Just bought new setup and was all dropped off in driveway 3 days later. It does take a day to install. A professional with correct tools, I’m sure can do it in a afternoon. But for a days work I save thousands. Best 1 day job that pays well!
@VaporheadATC
@VaporheadATC Жыл бұрын
Don't forget to ground the metal j boxes. You will take your incoming ground wire and connect it to the metal box, then tie it back into the outgoing line.
@tenthdimension9836
@tenthdimension9836 Жыл бұрын
I replaced mine about 2 years ago. I've never done it before. It took about 12 hours total time and I saved an absolute crapload of money and did a better job than most professional installers. I did it in early October so there was no conflict with heating or air conditioning. I swapped out an old roof vented 80% efficient piece of junk for a 96.5% efficient Goodman and vented it out the side.
@diyhvacguy
@diyhvacguy Жыл бұрын
Amazing. Glad you were able to get the same product and save a bundle!
@user-vs3yo5nu7n
@user-vs3yo5nu7n 5 ай бұрын
Hi I agree if you do yourself it nice and neat, contractors just want to get done and take money and go away, my I ask in your state??? You don't need license to do the hvac?? It not hard but it require license in Toronto canada when it come to gas,
@nygiantsfan84
@nygiantsfan84 5 ай бұрын
Bro 90% Percent furnaces absolutely suck…..you were better off replacing your old 80% furnace with a new one….trust me….
@latehappylife
@latehappylife Жыл бұрын
My Goodman furnace and ac is 16 years old. Never gave me a problem. Last year I got a few estimates to replace the furnace coil and compressor with the same Goodman units. The estimate ranged from $8000 to $15000 it looks like I have to pay the piper. In my younger days I probably could do the job myself. But at 86 , there is no way! by the way . That is a great video. I learned a lot . I wish you were in NJ.
@topher8634
@topher8634 Жыл бұрын
This scenario is every HVAC installers dream: upflow in a nice room with plenty of space. However, most installers often have to replace furnaces in a crawl space or tight attics or jammed into a closet in a narrow hallway. I have had to remove water heaters before to gain access to the equipment. The job is really harder than you think!
@diyhvacguy
@diyhvacguy Жыл бұрын
Umm, then hire a professional if it’s too hard to get to. 🤷🏻‍♂️ In Utah, 95% of the systems are just like this one 👍🏽 it’s a great place to be an hvac contractor.
@daffron101
@daffron101 Жыл бұрын
im from south east texas and all of our installs are in really hot attics with insulation and very little area to work...plus we use ductboard and the entire application is different than this application in a mechanical room upflow lol i would call this a dream job that you tell your work buddies for years to come haha
@newmoon54
@newmoon54 Жыл бұрын
In the 45 years (started '77!) I've been involved with HVACR service and installation, I've seen IT ALL~!~ LOL~!~ Residential change-outs and new installs were always the best work~!~ Plus you almost ALWAYS got a nice tip from the home owner if things went smoothly,, with it did 95% of the time or more~!~ I've always said, HVACR work is the very best of the trades~!~ Once you get past being a helper, it's $$$$ time for you~!~ I used to make between $200 - $400 plus after hours!!!! That was in early 198o's too~!~ Any one of you guys, and girls watching this video, go for it~!~!~!~ In less than 5 years you'll be making buku bucks~!~ No if and's or buts~!~
@petersmart1999
@petersmart1999 Жыл бұрын
Biggest issue is,you will have no warranty! Most companies will not issue any warranty unless it was purchased from a supply house and installed by an approved contractor!
@numchux2
@numchux2 Жыл бұрын
@@petersmart1999 to add to this, any time you make a major change to your home or make a major purchase, it needs to be inspected. You also need permits. If you get caught replacing your own furnace with no licenses, certifications, permits, and haven't a clue on code, be ready to be fined lots of $$$$.
@philxcskier
@philxcskier Жыл бұрын
Pretty cool! I’m an HVAC Engineering designer. I spec equipment and duct layouts and make up drawings. It’s nice to see the install, I always try and think of how the installer is going to actually put the stuff together, but that’s hard to do when you haven’t installed the equipment before. This gives me a bit of an insight on how you’d actually go about doing your checks and pull the old equipment out. Thanks for posting! I’m gonna follow your channel. 👍🏼
@tallboyhec4461
@tallboyhec4461 Жыл бұрын
Where do you work as a engineer designer, that's neat! I've always thought about going that route later on in life. I find it fascinating. I've been in service part of the industry.
@philxcskier
@philxcskier Жыл бұрын
@@tallboyhec4461 I work in Northern Canada, in a medium sized HVAC consulting firm. I started out in a small (3-5 person) firm. If you want to work in the HVAC Engineering field there's kind of 2 routes, at least in Canada. You can get your full mechanical engineering bachelors degree (4 years of school), then you become an Engineer in Training, and need to work for 4 years and apply to become a full Professional Engineer, with a stamp and legal designation. The other route is you can get an Engineering Technician certificate, its a trades program and I think it's about 2 years. The tech position is more of a support (drafting/site inspection) role since you need a full engineer to stamp and approve your work, but with experience you can also do lots of the design work under supervision. Since you have experience in the service industry that could be a nice fit since you already have some HVAC experience, you would just end up flushing out your knowledge with more in depth theory and math.
@aaronodonnel5001
@aaronodonnel5001 Жыл бұрын
“Jokingly “you’re the problem. Plans are never drawn with elevation in mind. It always shows a 12 inch high object in and 11 inch space
@davidwright1752
@davidwright1752 7 ай бұрын
Scary a engineer that cannot install what they designed. The best engineer is a tradesman that became a engineer. Please do the world a favour go out on job sites and talk to the guys doing the job. Engineers are fairly dangerous people. For example in Australia they designed a train and made some simple mistakes. The driver could not look out the driver-side to see the Marcus to pull up at the railway station. Then they made all the trains 6 inches too high they obviously did not consult. The train drivers never looked into the ergonomics. Never did a mock up to see how the passengers would step on in Brisbane Australia. We talking about hundreds of millions of dollars to create this very basic engineering mistakes, so an engineer theoretical person absolute hazard to every industry. If you don’t go out on the jobsites with mockups if needed and talk to every trade involved you’re just a pencil pusher but doesn’t care. When it comes to try and design, the very brilliant engineers designed a train 6 inches to wide for a train tunnel through a mountain. These issues also happened in the computer industry where programs are designed by people that cannot use them. I do not understand the business or how the end user is to use it.
@petef.4361
@petef.4361 7 ай бұрын
@@davidwright1752 I think they also "engineer" furnaces, compressors, etc.. to only last X amount of years before they fail. Great job security for HVAC techs if these expensive components need to be replaced every 5 or 10 years, as opposed to every 25 to 30 years. I know MANY units in my older neighborhood, including my own RUUD system, which lasted for at least 20 to 25 years. Yes they are probably more inefficient, but it proves that they CAN be engineered to last longer, they just choose not to. They just don't build them like they used to. Same goes for appliances. My mother had a refrigerator that lasted for over 30 years, a washing machine for over 10 years, and a dishwasher over 10 years with some minor inexpensive repairs along the way. Now, appliances are "engineered" to last 5 years if you are lucky, and it's cheaper to buy a new one and send the old one to landfill, than have it repaired due to exorbitant costs on replacement parts and labor.
@inspectr1949
@inspectr1949 Жыл бұрын
Great video, thank you. Have been in the building trades my entire life in addition to doing everything I also see everything so I also do everything myself with some associated guidance so I really appreciate what you posted here.
@diyhvacguy
@diyhvacguy Жыл бұрын
Of course. thanks for watching, cheers
@bairdjc
@bairdjc Жыл бұрын
Agreed. I helped my FIL (an electrician) replace his boiler - the toughest part of the job was manhandling the new boiler inside the home and to the basement. The old one we broke up (cast is brittle) but the new one was heavy as hell.
@jordanrichardson9645
@jordanrichardson9645 6 ай бұрын
Been doing hvac service work for years and definitely appreciate video that’s detailed like this always can learn from someone
@RagsHSC-7
@RagsHSC-7 19 күн бұрын
I must have missed seeing you clean the evaporator. I'm going to go back and and watch again. You really do A high-grade install for sure 👊😎 We had a normal contract with a HVAC company with the same mechanic. He taught me so much, especially when it comes to commercial units. Had an issue at my home while I was learning. Andy said you know everything about commercial units. It's the same principal. It's just smaller. The commercial units we use were flown by A. Helo put in place on the new building. Almost a 10 acre building me and another was responsible for all the mechanicals and electricals therefore. That is one nice clean job that you did. Jam up job brother. Proud of you. 👌
@erickmoen1014
@erickmoen1014 Жыл бұрын
I agree with previous comments on combustion testing and clocking the meter in case of natural gas to get proper btu input and proper combustion for maximum efficiency from your furnace install
@justwork_hvac
@justwork_hvac Жыл бұрын
That looks good brother . Super cool how you checked the static pressure and the gas valve.
@DerivingsPvP
@DerivingsPvP Жыл бұрын
Love the install. Very professional. I Will say though testing the static pressure is more accurate the closer to the blower. I make holes in the furnace with a zip in screw and use something to clear the insulation
@johnmontana1820
@johnmontana1820 4 ай бұрын
Great video, extremely helpful. I got stuck installing a furnace because you can't get a contractor around here to do it (they're all maxed out on new housing developments) and I did not have a clue about how to do it. The instructions that come with the furnace are just impossible to sort out. This video really clarified how you do this. Thanks a bunch!
@robertwilliams6288
@robertwilliams6288 7 ай бұрын
Thank you for making these videos so a non tech can understand them I have learned so much from your videos you have the hart of a instructor keep them coming. 👍
@micmike
@micmike 5 ай бұрын
Thanks for the lesson, it's not hard as you mentioned if one is mechanically inclined. It's great to see the steps involved and the money saving aspect is fantastic. Especially if one thinks they could save a little but still complete a safe furnace replacement. Thanks again for your help
@donaldmanning7379
@donaldmanning7379 Жыл бұрын
Great video and very detailed. You answered one question I had concerning the flex gas line and I thank you.
@diyhvacguy
@diyhvacguy Жыл бұрын
Of course! Thanks for watching!
@Patriottoo2
@Patriottoo2 7 ай бұрын
Dang! You're good. Your videos are so real, it's like we are right next to you while you work. Thanks for posting.
@richardhoner7842
@richardhoner7842 Жыл бұрын
It really is a straightforward job if the dimensions of components don't change very much. I got a couple quotes to replace 2 furnaces and after a bit of research realized the furnaces were being marked up $3-4000 and they wanted over $4000 for each installation. I bought the exact same furnaces for about $1200 each and installed myself for under $500 and about a day and half of my labor.
@diyhvacguy
@diyhvacguy Жыл бұрын
Nice!
@dailyrant4068
@dailyrant4068 Жыл бұрын
That's because HVAC is easy to markup... like plumbing. You can't really say no to someone that is going to get your heat back on when it's freezing. Obviously you have the DIY skills but in general HVAC folks can charge an arm and a leg just because.
@tycurtin7565
@tycurtin7565 Жыл бұрын
Where's a good place to purchase HVAC equipment? Sounds like you got a great deal.
@richardhoner7842
@richardhoner7842 Жыл бұрын
@@tycurtin7565 I used AC WHolesalers.
@gadgethunter5732
@gadgethunter5732 Жыл бұрын
Comparing doing it yourself to what a company charges is pretty immature. Company costs include specialized equipment , inventory, vehicles, employee benefits , insurance, permit costs and annual fees allowing them to do business in the fuels industry. I would be surprised if a manufacturer would honour the warranty on equipment installed by a unqualified home owner.
@PersianGulf007
@PersianGulf007 Жыл бұрын
Thank you for sharing your knowledge and experience with us. This was a great step-by-step furnace install. I was wondering in your near future videos if you can do a roof AC - Furnace unit install. 🙏
@diyhvacguy
@diyhvacguy Жыл бұрын
I don’t do any roof units but if I get one of those I will 100% film it! Cheers
@MK-wi1bj
@MK-wi1bj Жыл бұрын
Really nice, informative, clear, organized and neat job , thank for every thing.
@HobbyOrganist
@HobbyOrganist Жыл бұрын
I installed my new Goodman 80K gas, 96% furnace a couple of months ago with all new ducts and returns totally myself, I'm very happy with it and after a little adjustments to get a better duct balance I'ts good now. I added an external intake with damper, installed the gas and electric myself. Thankfully I have just heat only so I don't have to mess with A/C coils, condensors and all that krap stuck on top of the furnace etc I had my kitchen where my desk is feel cooler than the rest of the house, and the basement was as well due to insulation on all the ducts. I originally had 2 registers in the kitchen but blocked off one as the room is further from the furnace at the end of the duct run, but I wound up getting rid of the tee that went from thr 6" round to the two registers, and cutting out 4' too and making a straighter shorter run to the one duct and the airflow is MUCH better there now and much warmer. In the basement I cut a hole for a register in the 3x14 duct that goes to one register in the front room where the thermostat is, and partially closed the room's register- it was getting a lot more air and I suspect the furnace was shutting off sooner so the kitchen didn't get warm enough. I keep the thermostat at 73 degrees and the furnace is doing great.
@diyhvacguy
@diyhvacguy Жыл бұрын
Amazing. Thanks so much for sharing 🙏🏻 did you get quotes for the same job?
@stinerart1
@stinerart1 Жыл бұрын
That is a lot of work to still do it wrong but enjoy!
@thebackwoodsmechanic5029
@thebackwoodsmechanic5029 Жыл бұрын
Great information , supporting a fellow tradesman. Glad the channel is thriving
@diyhvacguy
@diyhvacguy Жыл бұрын
🙏🏻
@jongagnon5791
@jongagnon5791 Жыл бұрын
I really appreciate your videos and they are very educational. You made one earlier that somewhat touch on the newer high efficiently furnace but basically completely skipped over the fact you had to run a new flue and intake. Any plan in the near future to make a video on that? I bought a new furnace and turns out I cannot use my existing chimney and got caught off guard by it. This would help a lot of people, especially now these days that I'm sure a lot more people are installing high efficiency units.
@mitomendez3943
@mitomendez3943 Жыл бұрын
Don't be that hard yourself, this video is perfect for me, I love the screen wheel trick to create the creases or bends.
@erickmoen1014
@erickmoen1014 Жыл бұрын
Total external static pressure , ESP, is including the filter pressure drop. You need to take your return pressure reading between blower and filter.
@Dave-nm3xc
@Dave-nm3xc Жыл бұрын
You are awesome. As someone that needs a new furnace as mine is 30 years old, you give me the confidence to replace my furnace without the need to spend thousands of dollars that I don't have.
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome. Just make sure you are being safe! That’s all I ask :) cheers
@AllTattedUp13
@AllTattedUp13 Жыл бұрын
Manufacturer won't honor a warranty if a home owner does it diy...just sayn.
@Dave-nm3xc
@Dave-nm3xc Жыл бұрын
@@AllTattedUp13 I'm fully aware. At a savings of $6,000 I'm willing to live with that.
@jdwht2455
@jdwht2455 Жыл бұрын
Great video! One comment I have to make tho you may have covered it - make sure the local government building dept. is OK with a DIY install (permit) and if a final inspection is needed. Now, if you were to do a baseboard hot water furnace, you might do my area a world of good. I did ours about 10 years ago. I even purchased the same brand (Utica Boiler) assuming that the circ pump and zone valves would be a simple disconnect old and reconnect new. Nope. I got lots of copper piping soldering practice as everything was just the opposite. The spec sheets the seller had were outdated. Have to say that the new arrangement was cleaner. I learned a lot plus the higher efficiency furnace helped my gas bill somewhat.
@johnhaller5851
@johnhaller5851 Жыл бұрын
The big thing with the building department is that everything is local. This install was apparently in an earthquake area, and flex pipe was required. At my last house, they required hard pipe all the way. This is one of the things where a pro would understand what the inspectors care about. In a different install, all they seemed to inspect is that the AC has the correct sized breaker, since newer AC units frequently are rated for a smaller breaker than older installs. The furnace was not even looked at, perhaps because a local company which always gets permits did the work.
@Newt3700
@Newt3700 Жыл бұрын
Awesome Going to mine,myself . Thanks
@mikekatko7193
@mikekatko7193 Жыл бұрын
Great video, minor things, I never use a pipe wrench on brass, I always use an adjustable ie crescent on them to prevent bite marks. I would have put filler pieces in on the coil to prevent air bypass. Keep doing the great work!
@diyhvacguy
@diyhvacguy Жыл бұрын
Thanks so much for the feedback, I really really appreciate it. I try and make each one a little better then the last :) cheers
@sharpenflat6002
@sharpenflat6002 Жыл бұрын
I haven't used a crescent wrench since I was a kid. They make wrenches to fit all sizes, including metric.
@Dave-nm3xc
@Dave-nm3xc Жыл бұрын
@@diyhvacguy Class act response.
@BOHICA_
@BOHICA_ Жыл бұрын
@@sharpenflat6002 Crescent wrenches have purpose for the professional homeowner and pro. You are talking about auto mechanics not using a crescent wrench.
@petersmart1999
@petersmart1999 Жыл бұрын
@@sharpenflat6002 Knipex Smooth jaws!
@diannechiu8986
@diannechiu8986 Жыл бұрын
Great video for home owner. So if the furnace is being installed by a contractor, the home owner can understand what the contractor is talking about and ask good questions 👍
@keithsauer3574
@keithsauer3574 Жыл бұрын
I once had an error code on my goodman furnace and I think it was because I was using a very high merv pleted air filter. Our house and space was not blessed with a very big return, its 14x20x1 and I had like a MERV-8 pleted in there. Going down to those cheaper filters always resolved it. The static pressure thing makes sense.
@keytothegate68
@keytothegate68 8 ай бұрын
Merv 11 chocked my furnace to complete stall
@masterdirk101
@masterdirk101 Жыл бұрын
Pre covid our trucks cost 400 a month, post covid our new trucks cost 1200 a month. Same truck, same setups, equipment costs twice what it did before covid, our starting pay went from 12 dollars an hour to 20/hr. Flex duct if you can get it is twice the price as it was. Copper is more expensive, flux is more expensive, pipe is more expensive, in all honesty I'm surprised equipment doesnt cost more to install.
@anthonyheak3479
@anthonyheak3479 Жыл бұрын
Great video! From start to finish. Thank you!
@TheMonkdad
@TheMonkdad Жыл бұрын
This is helpful to reduce the anxiety of doing this job myself one day. I was told to replace my furnace about 15 years ago by a furnace company. I have multiple carbon monoxide detectors which never indicated any problem. 🤷‍♀️
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome. Knowledge is power and it’s in your best interest to have co testers. It’s getting harder and harder to find trustworthy hvac contractors.
@user-ik7dp1tz9j
@user-ik7dp1tz9j Жыл бұрын
@@diyhvacguy Most carbon monoxide detectors need 50 ppm for over 8 hours to go off, 9 ppm is the maximum safe level indoors. When you test for CO in the trades you typically have a device that will detect extremely small leaks. Your standard detector is there to keep you from falling asleep and not waking up, not to detect any CO leak your system has.
@stevemurzyn9711
@stevemurzyn9711 Жыл бұрын
Very informative video ! I would recommend using gloves when working around sheet metal due to all of the sharp edges. You have convinced me I can do my own install.
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome! If you need help with your replacement, check out our membership over at Patreon.com/diyhvacguy where for 25 bucks you will get one on one support and quick response times 👍🏼 cheers
@brandonharvey7939
@brandonharvey7939 5 ай бұрын
Instead of stripping the end of the green ground wire and puting a hook on it for your ground screw start your strippers about 2" from the end of the wire and just slide the green insulation 1/2" towards the end of the wire without sliding it all the way off. This gives you something to grab on both sides to curve the wire around the screw without taking the ground screw completely out and dropping it into the abyss. Also works with stranded wire and can be used instead of a ring terminal when in a pinch.
@partylee007
@partylee007 Жыл бұрын
Nice job on that furnace replacement. There is only one thing that I would have done and I did do differently on my gas furnace. Coming up off of the switch box to the box in the ceiling used a piece of three conductor #12 S/O cord with a male plug on the end and then put a 20a receptacle in that box in the ceiling. That way if there’s ever an emergency where the power is out, can have a generator outside run an extension cord inside and plug your furnace into an extension cord to give you your 120V for your blower and controls.
@roflchopter11
@roflchopter11 Жыл бұрын
You'll need to take steps to make sure you don't have mains on the male plug during normal use, and steps to make sure you don't backfeed the rest of your house (and the grid) when you run on the generator.
@partylee007
@partylee007 Жыл бұрын
@@roflchopter11 I know that
@whitcwa
@whitcwa 7 ай бұрын
I have a hardwired furnace and installed a small manual transfer switch made for connecting a generator via an extension cord. I can't wait until the next power outage!
@amnun11
@amnun11 3 ай бұрын
I agree with all comments of this video, excellent job, and very good explanation.
@benqtran
@benqtran Жыл бұрын
Great video! Appreciate all the details. In your next video, can you explain more about the adjustments of airflow with static air? Would love to see how you would adjust it. Thanks.
@diyhvacguy
@diyhvacguy Жыл бұрын
👍🏼 will do
@mikesimone1
@mikesimone1 Жыл бұрын
Your videos are so well done. You have a soothing, calm nature when you explain things. I'm a big fan of constructive criticism--we all learn from it. I just wish some of the people who point out ways to improve would be more tactful (or just be a bit nicer)--you deserve that for making these videos.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thank you so much sir. I wish people would be more tactful too. Like I’m open to advice but people don’t have to be so abrasive. Thanks again! Cheers
@danlah1303
@danlah1303 Жыл бұрын
Unfortunately, "experts" tend to be very critical whenever they see someone doing something that they believe only they are qualified to do.
@jessemalone8083
@jessemalone8083 Жыл бұрын
Agreed. I also need to be more tactful. Thank you to DIY GUY and to the commenters.
@djblackarrow
@djblackarrow Жыл бұрын
For solid Wires i would use the Wago 2273 Versions. They have no lever. All you have to do is to push the 11mm stripped wire into the hole and you are done. To loosen the wire, you have to twist it back and forth and pull it at the same time. The Wago 2273's are available for 2, 3, 4, 5 and 8 Wires. (2273-202, 2273-203, 2273-204, 2273-205, 2273-208)
@agartin1
@agartin1 Жыл бұрын
as much as wagos have been tested the small amount of actual connection concerns me. i prefer the twist the wires together and then add a wire nut. i know the old way...
@theunit5939
@theunit5939 Жыл бұрын
Been in the trade since i was 22 years now 38 the trade has been the best thing that has ever happen to me, best part is side job sat where in one day i make 2 weeks worth or work replacing a ac and furnace job.
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome thanks so much for sharing.
@diyhvacguy
@diyhvacguy Жыл бұрын
Best thing I’ve ever done too.
@kensimmo
@kensimmo Жыл бұрын
The instructions were very clear
@hectorgonzalez8185
@hectorgonzalez8185 Жыл бұрын
Thank you for all of your videos I have learn alot .
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome, I’m glad they are helping people :) cheers
@adolfovazquez8427
@adolfovazquez8427 Жыл бұрын
Wow tremendous video I think I learned more by wanting you that in technical school bro you are the best thank you again
@diyhvacguy
@diyhvacguy Жыл бұрын
You got it bro! Cheers
@danstojic5643
@danstojic5643 Жыл бұрын
Great job David!
@diyhvacguy
@diyhvacguy Жыл бұрын
Wouldn’t be able to do it without you🙏🏻
@greggutierrez7760
@greggutierrez7760 Жыл бұрын
Great video and I laughed pretty hard at the additional content (sniffing the customers crabs). That's a first! Tip to use a screen gasket tool for breaks is genius.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thank you 🙏🏻
@markw.2106
@markw.2106 Жыл бұрын
We just had our first floor furnace replaced, dual fuel, 80,000 btu. Cost us $15k. I checked with a few people I know who just had theirs replaced and that is the going rate here, North Carolina. Not a job I wanted to tackle, I'm glad you guys are out there. Hoping our upstairs system will keep going for awhile, I'm running out of kidneys to sell :)
@JoseloPezoa
@JoseloPezoa Жыл бұрын
i just had my furnace and 40 gallon water heater replaced,6200 dollars,in saskatoon sask. i hear some people have paid way more !!! 6200 new units ,parts and labor .
@PartTimeYooper
@PartTimeYooper Жыл бұрын
$15k for an 80k btu furnace....thats $13k in labor! How many weeks did it take???
@viet102082
@viet102082 Жыл бұрын
I need to move to North Carolina. Give yall 20% off $15k Furnace replacement job
@PartTimeYooper
@PartTimeYooper Жыл бұрын
@@viet102082 you could do half off and still make great money!!!
@markw.2106
@markw.2106 Жыл бұрын
@VietVlog 17 I've got another unit on the second floor so come on over :)
@rsearchtim
@rsearchtim Жыл бұрын
Thanks for this video to replace furnace's I love videos like this.
@JeremyStyninger
@JeremyStyninger Жыл бұрын
These furnace videos of yours keep getting better and you are giving out some very solid information. However, you did ask for feedback and I'm surprised you didn't take to heart comments about the electrical hookup regarding the Anti-short bushing inside the armored cable and a knockout bushing for the back of the junction box. It was pointed out in previous comments that leaving the wires unprotected can result in rubbing against the sharp edges and slowly, little by little over the next ten or twenty years (or more one hopes!) from the vibration of the motor. When the day comes that the insulation wears through the circuit protection may not trip because you didn't bond the ground to the junction box. And the one on the inside that you didn't fully seat can come loose.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thank you for the feedback, I have the bushings on my truck now, so that will be shown in the next install. I’ve see 30 year old systems no bushing and no issues so I’m finding it hard to wrap my brain around this one, but I want to make each one better so I will 100% do it moving forward. Thanks again for the feedback! Cheers
@gextreme2381
@gextreme2381 Жыл бұрын
Was thinking the same. Do it right.
@jimw6991
@jimw6991 9 ай бұрын
I normally don't run wires thru sheet metal holes without grommets (even low voltage). If I wanted to have the electrical junction box (switch box) mounted on outside of furnace, what could I use to protect insulation of stranded wires from getting chafed on knock out hole ? What about strain relief? Do you ever do something for stranded wires running from box to box in metal clad? I am not aware of anything in NEC about that. Also there was a comment that an anti short bushing was missed ? Where? I saw an orange bushing supplied in the end of the mc cable.
@gkblair
@gkblair Жыл бұрын
Easier than I thought - thanks!!
@bluangasa09
@bluangasa09 Жыл бұрын
Hello. How are you doing. I am watching you clip and you are so great, to explain everything you do. I am very happy to see. I am learning from you. You are doing great 👍job
@diyhvacguy
@diyhvacguy Жыл бұрын
🙏🏻
@keovongvilaykeo4799
@keovongvilaykeo4799 Жыл бұрын
Always great content 😊thanks you again 😊
@diyhvacguy
@diyhvacguy Жыл бұрын
So nice of you. Thanks for watching! Cheers
@kennethlankford6809
@kennethlankford6809 11 ай бұрын
Grown up , fixing everything , like a farmer, thanks
@charlesgranthom5908
@charlesgranthom5908 Жыл бұрын
love the install the best easy to understand.
@jackonthefarm5540
@jackonthefarm5540 Жыл бұрын
I appreciate your making this video. I would additionally have liked to have seen how you cleaned the "A" coil and contain the mess. Some viewers might not have detected that this was a low-efficiency furnace. I would think most modern installations are high-efficiency condensing units.
@diyhvacguy
@diyhvacguy Жыл бұрын
It’s all based on how much the homeowner wants to pay. This particular one wanted to spend as little as possible so that’s why they got a lower efficiency furnace.
@paulmoffat9306
@paulmoffat9306 Жыл бұрын
In my area, a 92% efficient furnace is the minimum allowed. I had a 96% one installed in my house, 98% was available, but it was a lot more expensive.
@whitcwa
@whitcwa 7 ай бұрын
@@diyhvacguy Some people don't understand operational cost will be higher than purchase cost. The savings over the life of the higher efficiency furnace makes it worth it. If you explain it to them, they may be convinced.
@erics9213
@erics9213 Жыл бұрын
This is an amazing tutorial on gas furnace replacement. I have not seen this much detail on other videos. I especially liked the air cleaner attachment and static pressure measurement technique. I've seen a lot of transition videos but your was a new twist for me. Could the temp rise have been measured at the furnace return air/supply air ducts?
@diyhvacguy
@diyhvacguy Жыл бұрын
Probably so on the temp locations. There is quite a range on temp rise. Thanks for the feedback! I appreciate the support 🙏🏻
@inspectortv100
@inspectortv100 Жыл бұрын
Thanks for sharing
@carlosjackson4474
@carlosjackson4474 Жыл бұрын
AMAZING VIDEO, CLEAN WORK!!!!
@ronzek3207
@ronzek3207 Жыл бұрын
Use a Cresent smooth jaw wrench on brass or copper fittings leaves no marks and safer from cracks forming from deep cuts from pipe wrenches,
@nygiantsfan84
@nygiantsfan84 5 ай бұрын
Phenomenal install bro
@wdxwm300
@wdxwm300 7 ай бұрын
Explained very well Thanks
@paulaboukhaled813
@paulaboukhaled813 Жыл бұрын
Great video. Thank you for sharing.
@diyhvacguy
@diyhvacguy Жыл бұрын
Of course 🙏🏻
@deltasquared7777
@deltasquared7777 Жыл бұрын
Really nice video ! - one suggestion: wherever possible use a square drive screwdriver bit instead of a phillips; you have much better control of tightness and it is far less likely to slip out or strip the screws. Phillips screws are designed to cam out without overtightening, but if the screwdriver is or the screw is worn, it does not serve this function properly. (note that you can use a Japanese Industrial Standard -JIS- screwdrivers that is designed not to cam out and works much better than phillips-indeed if you have a Japanese car or bike then using a phillips screwdriver is an invitation to disaster)
@spirogovas8722
@spirogovas8722 Жыл бұрын
The square aka Robertson screw is Canadian. It is superior, but Americans have too much pride to use it.
@deltasquared7777
@deltasquared7777 Жыл бұрын
@@Kevin-mp5of many very commonly used phillips screws-like those in electrical outlets and circuit breakers- also accept square drive as well as straight screwdrivers. only torx screws will accept torx, which-like many other uncommon screw types- are somewhat of a specialty item
@deltasquared7777
@deltasquared7777 Жыл бұрын
@@Kevin-mp5of You are so smart about this stuff that it scares me. you must be using google search to find all of this stuff that is not relevant to my original simple comment.
@topher8634
@topher8634 Жыл бұрын
@@spirogovas8722 I use it all the time. Just about everything electrical uses either #1 or #2 Robertson.
@whitcwa
@whitcwa 7 ай бұрын
@@spirogovas8722 I hope you're joking because it just isn't true.
@rayfridley6649
@rayfridley6649 Жыл бұрын
28:53-That flexible electrical cable section looks like BX cable shielding.
@bendent9002
@bendent9002 Жыл бұрын
Non marring tools highly recommend. Can't stand tool marks but, as for the Romex wire above the metal duct, I hope it was secured to the joice and not just left laying on top? As for the tape, not a big issue to me, least it is sealed. Oh, one more thing. The flex pipe connector, I use the high flow shut off type. Once installed it will not flow if not connected while gas is in on position. Goes good with the earth quake scenario.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thanks for the pointers! Cheers
@dragonlordship
@dragonlordship Жыл бұрын
Thanks for your teaching. Can you post the instllation video of replacing the 80% furnace with HE(>90%) that required removing metal duct and installing the PVC for condensation.
@jonathanhoskins6580
@jonathanhoskins6580 Жыл бұрын
It would be interesting to see a downflow unit with ducting that attaches to the bottom of the furnace
@user-ik7dp1tz9j
@user-ik7dp1tz9j Жыл бұрын
Evaporator coil needs to be flush to sheet metal on the left, right, front, and back to provide proper air flow, this leads to major issues down the line. Mastic should be applied outside of the unit, inside application as shown here leads to it cracking over time and causing issues (not a major issue, just not ideal and you can avoid future issues by applying this outside the unit). Flexible gas lines frequently (at least in my state) require the gas line to be bonded.
@diyhvacguy
@diyhvacguy Жыл бұрын
Thanks for the feedback! 👊🏼
@habaneropepper4156
@habaneropepper4156 Жыл бұрын
A good thing to mention is your typical NPT pipe thread make up is 3/8”-1/2” some times people with no experience over tighten fittings. And it doesn’t matter the diameter, weather its 3/4” or 1 1/2” diameter pipe it will thread in approximately 1/2” and should be close. Good job!
@MiteyMOofyearsAgo
@MiteyMOofyearsAgo 7 ай бұрын
Very thorough! Thank you
@jeffreyritchie1447
@jeffreyritchie1447 Жыл бұрын
I never get that lucky! I always end up changing out 75 year old Williamson units with new 95% ones!
@paulmoffat9306
@paulmoffat9306 Жыл бұрын
The only thing, is that in my area, only a licensed gasfitter can connect the gas line, and in addition, requires a connection inspection by the gas utility. The gasfitter also installs a certification seal on the piping they did.
@shepherdhillfarms7821
@shepherdhillfarms7821 11 ай бұрын
Cool video! One “issue” I have with what you did; I work in the natural gas industry, shutting of and turning on the gas shut off at the meter is illegal! It is what is considered an “OQ covered task” meaning it should ONLY be done by the gas company. Thanks for what you do! I appreciate how in depth you go and the knowledge you are able to share.
@VideoArchiveGuy
@VideoArchiveGuy 7 ай бұрын
In most areas shutting OFF the gas at the meter is something anyone is allowed to do, but only the gas company is allowed to turn it back on. For example, disaster planning advice is to shut off the gas to your house, and then the gas company will go around turning it back on after your house is checked to make sure it's safe.
@shepherdhillfarms7821
@shepherdhillfarms7821 7 ай бұрын
@@VideoArchiveGuy I am in the natural gas industry, turning on/off a gas service valve, the valve before the meter, is considered an “OQ covered task”. OQ stands for Operator Qualifications. This means that to turn off or on the valve, one MUST be on OQ covered employee based on the standards set forth by the federal DOT and the other governing bodies of the transport of natural gas. In the IFGC, gas code book, it states that the only other individual(s) who can turn off the gas service valve are the fire dept in emergency situations, and the “code official” again, in emergency situations but they are NEVER allowed to turn service back on.
@VideoArchiveGuy
@VideoArchiveGuy 7 ай бұрын
@@shepherdhillfarms7821 It warns official personnel will be needed to turn it back on, but even this FEMA document details how to shut it off. www.fema.gov/sites/default/files/2020-08/fema_earthquakes_fema-p-530-earthquake-safety-at-home-march-2020.pdf
@Struthio_Camelus
@Struthio_Camelus 7 ай бұрын
@@shepherdhillfarms7821 Who enforces the "OQ covered task" requirements? Every time my gas company replaces the meter (7-year intervals) they insist on relighting any pilot lights and performing a safety check on any connected equipment - which is fine. The gas company tech could probably tell that a DIYer was at the meter if there were pipe wrench jaw-marks on the valve, but other than that, who is going to know?
@shepherdhillfarms7821
@shepherdhillfarms7821 7 ай бұрын
@@Struthio_Camelus Great question! It really is not enforced. Technically if the gas company wanted to, they could pursue prosecution, but it would most likely not pan out. It is technically against federal law to operate the gas service valve unless you are OQed by the operating company. So, if I am on vacation in another state and operate a service valve, I am in violation of law even though I am OQ qualified with my company in my state. The only reason I commented was to bring awareness. I have been to emergency calls where the gas was turned off, then back on by someone who did not do it right and it caused the regulator to fail and cause a leak. It can be a dangerous situation, and if there was ever to be an incident, then I am sure whomever operated the valve illegally would be prosecuted.
@TomCee53
@TomCee53 Жыл бұрын
It’s great that you put in instructions for the water heater but you should’ve mentioned that not all water heaters are the same. Check the instructions for yours specifically and you may have to find them online or in a book.
@Gunman1628
@Gunman1628 Жыл бұрын
i ama pretty good Diy er. furnances seem to come in pretty standard sizes and if replacing one just find one that matches the old one in output and size. when it comes to prices, i have seen them all over the place. a $1k furnace is probably $5k installed by a company. when it comes to permits , if a home owner is apt to pull them, its not much difference than wiring your house. as long as an inspector comes out and signs off on it they should be good .
@KLBrown-pw7bs
@KLBrown-pw7bs 5 ай бұрын
Excellent furnace video!
@hamdig390
@hamdig390 Жыл бұрын
Thank you so much !!
@DirtySnowman439
@DirtySnowman439 Жыл бұрын
the only thing i did notice was at the 30min mark the junction box was not grounded IAW 250.148 - Continuity and Attachment of Equipment Grounding Conductors to Boxes. If circuit conductors are spliced within a box or terminated on equipment within or supported by a box, all equipment grounding conductor(s) associated with any of those circuit conductors shall be connected within the box or to the box with devices suitable for the use in accordance with 250.8 and 250.148(A) through (E)
@ronie1337
@ronie1337 Жыл бұрын
Great info thanks.
@blaccayman5233
@blaccayman5233 Жыл бұрын
your lucky in Utah to buy this equipment. here in SoCal, only licensed holders can buy them. and as of 2019 can install LoNox. they burn much higher and am told by techs, are more challenging to dial in. Also, the heat exhaust vent needs to be replaced to accommodate the new furnace. on a 2story house, that can add up. SoCal DIY's have been sidelined when wanting to practice what you perfectly preach. Keep up the good show. props to your camera man. BTW what food did you almost smell left in the evaporator. that was gross N funny.
@RandyMoe
@RandyMoe Жыл бұрын
Thank you!
@NovvaOfficial
@NovvaOfficial Жыл бұрын
When you turn the gas meter back on, it should be turned on in a slow and controlled manner so that you do not slam the diaphragm of the regulator.
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome. Thanks so much, I didn’t know this but I’ll make sure and do that on all future replacements! Cheers
@NovvaOfficial
@NovvaOfficial Жыл бұрын
@@diyhvacguy You’re very welcome! I work for a local gas company in the PNW, it’s not an uncommon occurrence for us to respond to a relieving regulator because the diaphragm blew. :) Stay safe, and thanks for the videos!
@kennethbubser9601
@kennethbubser9601 Жыл бұрын
Because in nj we have a master Hvac license. Also we have to warranty job. Workers comp, liability Insurence. Just because you can put heater in don’t mean you know what your doing. Did you run load calc to make sure your not over sizing equipment. Some jobs you got 6000 to 8000 dollars in equipment. Two stage, multi stage. Gas with heatpump.
@msbcas012
@msbcas012 Жыл бұрын
Nice Job. I recommend a combustion analysis before commissioning.
@kevincowan7131
@kevincowan7131 Жыл бұрын
Thanks Brother keep recording before you know it you will have 1 Million subscribers!!!!!!!!
@82ndRelic
@82ndRelic Жыл бұрын
Thanks!
@diyhvacguy
@diyhvacguy Жыл бұрын
Thank you so much! 🙏🏻
@preetsingh4139
@preetsingh4139 8 ай бұрын
Perfact Job Thanks for the video.
@stewartjohnston3975
@stewartjohnston3975 Жыл бұрын
Fantastic video!!!! Great job!
@bobmanp8653
@bobmanp8653 Жыл бұрын
I did mine it was super easy
@mark33545
@mark33545 7 ай бұрын
Would be awesome if you could do annual service video on that 80% Goodman since many of us have that then that weird mini high efficiency one you did. Especially since the gas line was portable on that one.
@rtel123
@rtel123 Жыл бұрын
So glad I suggested to the installer for my new furnace to put four concrete bricks underneath. A two inch flood in the past has often caused water damage in the furnace. Can be avoided by not putting the metal box directly on the floor.
@diyhvacguy
@diyhvacguy Жыл бұрын
This one had a slope to the drain, so I just had one of those rubber blocks on the front left corner. If it was totally flat I would have put 4 of them. Thanks for the comment! Cheers
@greenidguy9292
@greenidguy9292 Жыл бұрын
Your installation isn’t the same as others, so what works for you isn’t always necessary for others. You obviously don’t know that as you aren’t an installer.
@calbuilder7357
@calbuilder7357 Жыл бұрын
Thanks for a great video
@diyhvacguy
@diyhvacguy Жыл бұрын
You got it! Thanks for watching!
@seabass22
@seabass22 10 ай бұрын
I’m gonna have to swap mine at some point. We have propane furnace. It’s expensive to run. Gonna have to swap to electric at some point. Thanks for the videos.
@MK-wi1bj
@MK-wi1bj Жыл бұрын
Good job.
@xoLauren1985
@xoLauren1985 Жыл бұрын
Awesome video! Tons of useful info. Being a Journeyman Electrician myself, I would consider grounding the NM to MC metal junction box also. I know it’s grounded through the equipment itself (in this case the furnace) But if one ground location is good two in better. 😉
@diyhvacguy
@diyhvacguy Жыл бұрын
Awesome thanks for the input! Cheers
@xoLauren1985
@xoLauren1985 Жыл бұрын
@@Kevin-mp5of Very true. I was just speaking for this instance😉
@xoLauren1985
@xoLauren1985 Жыл бұрын
@@diyhvacguy NP! Great work and great videos.. Have a nice Christmas!
@Artem_Gratis
@Artem_Gratis Жыл бұрын
Crab sniffer! 😂😂😂 Awesome video and invaluable content thank you so much
@diyhvacguy
@diyhvacguy Жыл бұрын
🤣🤣🤣 thanks man
@ThuggBoi69
@ThuggBoi69 Жыл бұрын
Good job,😊
Save THOUSANDS Replacing Your Gas Furnace Yourself.
54:49
The DIY HVAC Guy
Рет қаралды 316 М.
How To Convert Your Air Conditioner To A Dual Fuel Heat Pump
47:19
The DIY HVAC Guy
Рет қаралды 55 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 13 МЛН
Получилось у Вики?😂 #хабибка
00:14
ХАБИБ
Рет қаралды 7 МЛН
80% vs 90%+ Condensing Furnace
17:56
Love2HVAC with Ty Branaman
Рет қаралды 97 М.
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 244 М.
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2 МЛН
Soldering An HVAC Line Set Using Staybrite 8.  STRONGER THAN BRAZING!
29:04
Yearly Furnace Cleaning And Maintenance Pro Tips
8:56
Everyday Home Repairs
Рет қаралды 946 М.
HVAC Contractors Practically Make Their Living On These
11:26
The DIY HVAC Guy
Рет қаралды 1,1 МЛН