Sir ask ko lang po in designing beam cinoconsider din po ba yung earthquake load galing sa base shear ?
@nioroskyengineeringonline89682 жыл бұрын
Yes if the structure is a multiple storey. We need to scale the amount shear force as a reaction compared to shear force received. We do response spectrum analysis. Cheers
@ender_paul Жыл бұрын
Master ask lang po if yung oag minus ng 0.85fc sa fs is required and for displaced concrete po ba yan?
@nioroskyengineeringonline8968 Жыл бұрын
Good day, i have an explanation regarding that. Please see this link: kzbin.info/www/bejne/hWi8qohqmbucfpo
@ender_paul Жыл бұрын
@@nioroskyengineeringonline8968 Noted po sir, is it practiced currently po sa Board problems/exams ? Or is it just an optional better approach po for designing?
@nioroskyengineeringonline8968 Жыл бұрын
@@ender_paul yes same approach on board exam.
@jamesmartinmoradilla65523 жыл бұрын
Hi po Sir. Bakit po iba yung approach ng pag identify if doubly yung beam. Last example is using rho max by the strain 0.004 (max strain for tension) and dito po is using fs=fy balance condition. salamat po
@nioroskyengineeringonline89683 жыл бұрын
Hi i think it was explained in the commentaries. Tensile strain of 0.004 is used since it was stated in the given under strength based condition where reinforcement are given. The use of fs=fy is the methodology of assumption to check where ductility is a constraint to identify whether under or over reinforced. This is done to both problems, kindly check ot again. The only difference is in the past the given os strength based condition for ductility while this problem is non-ductile. Please refer to this link of my video lecture for a more detailed explanation. It can be also found on my playlist. kzbin.info/www/bejne/hWi8qohqmbucfpo cheers