Edwards Coded Pull Station Review - In depth look

  Рет қаралды 1,689

Aaron Productions

Aaron Productions

Күн бұрын

Пікірлер: 27
@NyxKemo
@NyxKemo 3 жыл бұрын
If i ever get one of these pulls, i have some industrial grade fast relays that would work with these types of pulls
@HappyJigg
@HappyJigg Ай бұрын
I think it's normally closed for supervision reasons. If it was hooked up to a relay exactly as you did, the alarms would start ringing when a wire got disconnected. I think the other NC contact is for "non interference", where each pull is wired through both the alarm contact and NC contact in series, so if two go off at the same time they don't code over each other. I think the lever inside also has something to do with this. Maybe different models had an electromagnet to pause the station while others were going off, so each would do its full round of coding. I know many Gamewell Master Boxes have that feature, and there is at least one video showing it off on youtube. Great video!
@Thunderbolt1003
@Thunderbolt1003 5 жыл бұрын
That’s really cool, also didn’t it come with a glass rod?
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Thunderbolt 1003 yes, but like I said at 3:57 , I do not have it
@Thunderbolt1003
@Thunderbolt1003 5 жыл бұрын
Aaron Productions oh I must’ve missed that part
@relevanteaglealarms109
@relevanteaglealarms109 4 жыл бұрын
Use a Gentex Commander 1 for the glass missing.
@GamewellGuy95
@GamewellGuy95 5 ай бұрын
Does it need a relay to work?
@Roxxofoxxo
@Roxxofoxxo 5 жыл бұрын
I have one too I got my from a building that was going to be demolished it is in very good condition
@evanbart4109
@evanbart4109 5 жыл бұрын
Nice 😀👍👍 I see you trying to make a macro-cinematic sequence. Did you use a magnifier over your phone/camera?
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Evan Bart 410 it’s a macro lens
@evanbart4109
@evanbart4109 5 жыл бұрын
Aaron Productions are you using a macro lens, with a DSLR/SLR Camera?
@Aaronproductions
@Aaronproductions 5 жыл бұрын
Evan Bart 410 for that part yes
@alamorailfan
@alamorailfan 5 жыл бұрын
Hey, I saw a fire panel that had an active Supervisory: Phase Reverse on point 50. I believe it was a Rev 2 200UDLS. What does that mean?
@Aaronproductions
@Aaronproductions 5 жыл бұрын
SATX Railfanning Productions supervisory is something they set, if it was a system fault it would give a trouble, on point 50 they must be monitoring a phase reverse monitoring device, why they would need that and why the panels monitoring that, I don’t know.
@smallmariobros
@smallmariobros 5 жыл бұрын
cool!
@vintagefirealarmguy5285
@vintagefirealarmguy5285 5 жыл бұрын
Great video 😊👍👍
@nathancarpenter4929
@nathancarpenter4929 4 жыл бұрын
Where do you get your relays and how much are they?
@Aaronproductions
@Aaronproductions 4 жыл бұрын
Nathan Carpenter eBay, $15-30
@KanoaDeCastro
@KanoaDeCastro Жыл бұрын
I think Terminals 5 and 6 would be wired to the fire dept.
@jaredw83
@jaredw83 5 жыл бұрын
Cool video
@jozefcunningham1953
@jozefcunningham1953 5 жыл бұрын
U need screw driver
@Aaronproductions
@Aaronproductions 5 жыл бұрын
jozef cunningham I have many screw drivers...
@smallmariobros
@smallmariobros 5 жыл бұрын
cool!
EEVblog 1566 - Rigol DHO800 12 Bit Oscilloscope FULL REVIEW
1:00:46
Do you love Blackpink?🖤🩷
00:23
Karina
Рет қаралды 23 МЛН
Одну кружечку 😂❤️
00:12
Денис Кукояка
Рет қаралды 2,4 МЛН
5 Different BG-12 Series Pull Stations! (that I own)
9:59
Luca Castagno
Рет қаралды 11 М.
The fastest CPU in the world
25:53
Linus Tech Tips
Рет қаралды 1,3 МЛН
This tiny computer changes EVERYTHING
15:57
Jeff Geerling
Рет қаралды 712 М.
An 'Addressable' Fire Alarm! - Wheelock AMT Review
8:13
Aaron Productions
Рет қаралды 2,1 М.
Free Internet - Hacking Foreign Satellites
31:38
Peter Fairlie
Рет қаралды 782 М.
Horn strobe vs fire bell which is better and louder
18:33
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 16 М.
#112 LoRa / LoRaWAN De-Mystified / Tutorial
20:25
Andreas Spiess
Рет қаралды 1 МЛН
Edwards Coded Pull Stations | How do they Work?
6:15
S.E.R. Safety
Рет қаралды 92 М.
How Addressable Fire Alarm Systems Work
14:06
Aaron Productions
Рет қаралды 42 М.