Not content with 400 resistors, Dave ups the ante with several thousand genuine OneHungLow resistors, a semi-automated test jig, and some anger and love for the Agilent U1272A multimeter.
Пікірлер: 201
@SidneyCritic8 жыл бұрын
I wish he went back and did the 400 Phillips with the Agilent so that we know if it was the meter. If you want I'll drive 45 min over there and do it because it's killing me.
@jpmorgan1878 жыл бұрын
SidneyCritic ComedyHound do it! I have to know
@SidneyCritic8 жыл бұрын
I went to a few shows and didn't see him, and he doesn't read these, so looks like we will never know.
@Tangobaldy10 жыл бұрын
Im the 29,065 viewer. Learning so much from the videos.
@pepe66667 жыл бұрын
another first prize video. i will never get sick of this show.
@MicroRCFiend9 жыл бұрын
Really enjoyed your approach to this Dave, the rigs to test electronics are a pure joy to watch develop. Please consider adding any more you do in the future. It's a shame the software let you down finishing the data production but this didn't take away from the wicked problem solving lessons.
@technodaz11 жыл бұрын
Shame I did not see this a year or 2 ago man just discovering your clips and there great. I work for Microsemi , could have had the lads test those on a machine in around 2 mins for 1,000 resistors :P
@iugiastgottrolato12 жыл бұрын
Yep. They are 50ppm resistors and if they are calibrated at 25°C the offset is explained!
@SomeMoreVideos246813 жыл бұрын
Hey Dave, I know you sorted it with the import options but for reference, you could use find+replace on your spreadsheet software to get rid of the letters. E.g. search for ' m' (without quotes) and replace with nothing. Great project BTW, and thanks for putting the effort in!
@Fir3Chi3f13 жыл бұрын
Love the FSM shirt and yet another great video. I'm still working through all your videos for my EE education
@AluVixapede8 жыл бұрын
I know this is an older video but I still love this kinda stuff :3
@EEVblog13 жыл бұрын
@SajjadBro Yes, it will log any parameter.
@JustinHallPlus9 жыл бұрын
Looks like you couldn't read your handwriting on that .9966. It was right the first time XD
@Dibblah190013 жыл бұрын
Wow. A test jig which doesn't involve hot melt glue? Well done!
@EEVblog13 жыл бұрын
@Wilfredkazoks Not possible. The mat is not conductive, only dissipative.
@petersage51576 жыл бұрын
The ending was hilarious. If only companies like Agilent (now Keysight - bloody HP keeps rebranding its subsidiaries, hoping consumers will forget the sins of their past) embraced open source at least for software, this bug would have been fixed within hours of Dave uploading the video. Of course, then they wouldn't be able to charge astronomical fees for software "upgrades"...
@AureliusR10 жыл бұрын
EEVblog You need to delete the OL as the first data entry, clearly. It's a bug in the Agilent software. I don't know how you didn't correlate that
@envisionelec12 жыл бұрын
What's with people complaining about your vocal inflections? I've met plenty of Aussies with that cheerful tone. I like it! :)
@08Ultrasonic9 жыл бұрын
23:22 Ops! Dave wrote the numbers down incorrectly.
@cmreel10 жыл бұрын
300° C ouch... Might have to take your town off my to visit list!
@EEVblog13 жыл бұрын
@sepertude Not really. Calibration is all about "confidence" in your readings, and it's possible to get good confidence in that without going to a cal lab. You can use precision resistors like that as a transfer standard.
@yabgu798 жыл бұрын
Last two minutes ruined all my impression on that bloody multimeter
@UpcycleElectronics7 жыл бұрын
^2nd^ Hate mail at Agilent
@thewii55212 жыл бұрын
You made that "OneHungLow" sticker, didn't you...
@jerryfox3731 Жыл бұрын
That was very impressive. I enjoy watching the whole video. You definitely get a thumbs up from me.
@Necrocidal3 жыл бұрын
32:00 There may also be multiple production lines giving different distributions and means, causing significant variation between different batches. Only thing you can trust is the datasheet (and not even that after seeing your dodgy digikey video!)
@Joru66612 жыл бұрын
@Joru666 I'd figure the production process has given the nominal value as it turned out, of about .035-0.4% under nominal value. The gap from -0.1 and higher would be because they've been picked to fit 0.1% error range, that would actually make sence to me, correct me if I'm wrong.
@superdau13 жыл бұрын
Looks like i wont get to sleep tonight (it's 3:30 here in Europe now). First the guys from the geekgroup make a one hour video, now you over half an hour. But HAVE TO WATCH! ;)
@philbx113 жыл бұрын
To quote the comedy 'I.T Crowd'. "Have you tried turning it off and on again? " BTW, you know how some smartasses think they have better ways of doing things. Here's mine... Arduino (or whatever) connected to an RC servo with the servo arm shaped like a cam mounted above the pushbutton on the meter. An input wire is connected to a switch on the probe board and this is pressed as the pogo is pushed onto the resistor. Anyway, enough of the crap idea stuff. great patience and resourcefulness Dave!
@EEVblog13 жыл бұрын
@Superfungus0 No, its doesn't. The mat is dissipitive, not conductive. >>Gohms.
@AngDavies4 жыл бұрын
What was the ppm temp coefficient on those things? You seemed to be probing at 28 degrees or so. A 100ppm coefficient would give that change in average resistance if it was that negative in that portion of the range, which it could very well be due to tweaking to get the curve as flat as possible over the entire range
@lolman200811212 жыл бұрын
love the FSM t shirt, same views here. and once again a most interesting video.
@SeanBZA13 жыл бұрын
I would guess the manufacturer has not calibrated his plant recently, or is not worried as all are within a tolerance band. As all the resistors are from the same batch, and were made at the same time, more or less, as you can see from the data, which shows no clear trend related to sample number. They probably were aiming to be no more than half way to the limit, and were not going to change anything whilst it was running well.
@EEVblog13 жыл бұрын
@mortaldrumming Countless options. Ebay, Alibaba, or your local electronics store (like Jaycar or Altronics in Oz) who source from the cheapest place they can get it from in China.
@EEVblog13 жыл бұрын
@DanFrederiksen Yeah, countless ways to Macgyver a solution to fully automated it. Reliable probing is always a pain though. The devil is always in the detail.
@TekedixXx4 жыл бұрын
ONE HUNG LOW! I thought that was a joke! Christ. Fuckin classic.
@SeanBZA13 жыл бұрын
I once had to test 1k of caps, using a LCR meter. Took 2 days to do, though only about 5 were out of tolerance, failing for high ESR. Not bad for a batch of 40 year old CTS13 tantalum capacitors. I made the 5 failures into little rockets ( reverse voltage of 28V current limited to 10A whilst case lead clamped in vice, will blow the pellet out when the solder melts. If you do not clamp the case then the case disappears leaving the slug behind) and fired them in the office.
@zenomp513 жыл бұрын
@8:32 "Stevie Wonder could even probe this thing" hahaha!
@EEVblog13 жыл бұрын
@GGTrashes Just some skin taken off. Likely from weights at the gym or some such. Haven't had a wart since I was a kid.
@volodymyrzakolodyazhny3 жыл бұрын
Good job!
@flyguille9 жыл бұрын
so, Dave, you got a not calibrated equipment, the average offset means that it is an equipment fault.
@foobargorch9 жыл бұрын
flyguille 21:30
@unlost1179 жыл бұрын
+flyguille Perhaps. Dave used crocodile leads and not his test jig to test the calibration resistor at 21:30 even tho he used his test jig to null his meter for zero ohms at 22:39 Can someone tell me if this meter can be calibrated at say the 1kohm mark as well as the zero ohms mark ?
@marshaul8 жыл бұрын
Does it? It wouldn't be the first resistor batch to be biased below the nominal value.
@DJPhilTBCollins13 жыл бұрын
I find it somewhat comforting that OneHungLow is a brand. At least, I hope it is.
@Systemrat200813 жыл бұрын
Recently you where playing with precision decade boxes and now this there a reason other than just curiosity your doing all this work to establish the tolerance spread of resistors. Oh nice video too. :-)
@ElectronicsPubVideos12 жыл бұрын
OMG OneHungLow really exist! I was thinking its Dave's myth!
@jan.tichavsky13 жыл бұрын
@Wilfredkazoks The antistatic mat has some resistance on the bottom side, on the top side it's insulated so it doesn't mess with your electronics (imagine that you're servicing something plugged in mains).
@EEVblog13 жыл бұрын
@philbx1 You'd still be limited by the response time of the meter and the mechanical movements, so I doubt any such approach would improve the testing time much. Unless you had to measure 100K+ of these things, I think I currently have the optimum diminishing returns approach probably up to 10K-20K, as long as you don't mind doing the work that is!
@aptsys13 жыл бұрын
The 0.9966 was 0.9966 before, he must have written the 6 as a 0.
@Joru66612 жыл бұрын
From what I've been told by my teacher, If you have, say 5k resistor with 5% tolerance you may be pretty sure it is going to be quite off the nominal value. As he explained it is due to the fact that if the resistor is within lower error value, say 1% it is going to be sold in that range for higher price. That may also be true according to those 1% resistors you measured in the video.
@volodymyrzakolodyazhny3 жыл бұрын
This could be a fact for older times. But today it is much cheaper to make different lines for different tolerances.
@gilgameshismist13 жыл бұрын
@EEVblog I am in love with the meter, excellent choice! (BTW: you do have a good taste for t-shirts ;) )
@dooces112 жыл бұрын
why not just use 2 plastic gears on the bottom, 2 metal gears on the top attached to your probes to feed the resisters while testing?
@laernulienlaernulienlaernu89534 жыл бұрын
Never mind, you've figured it out. I can't believe you don't know how every one of your 136 different multimeters work!
@EEVblog13 жыл бұрын
@Superfungus0 It's not the bandoleer either.
@pyromen3213 жыл бұрын
In case anyone wants to do something like this, I have a bit of advice for an easy way to grab each resistor without any fancy equipment. Drill two holes in a small piece of wood, plastic, foam, anything or anything, then jam minigrabbers into the holes. Done. With just one hand, you depress both minigrabbers at the same time and grab each resistor immediately without any fuss.
@Th3Su813 жыл бұрын
I really like that multimeter. I think that I have found the next piece of gear I need to purchase. Unless, Dave, you would like to get me an early birthday gift. ;-)
@EEVblog13 жыл бұрын
@funkmastertraf No, thanks for asking. But so what if I was?
@VolksTrieb13 жыл бұрын
Nice one again dave ;)
@aknewhope9 жыл бұрын
The test jigs built using pogo pins to make connection to the pcb are also known as a "bed of nails" and can be quite complex. Worked on a system for testing electric car chargers which had high voltage AC/DC present. Must have been 200+ pins for a single board wired into a national instruments system.
@thewii55213 жыл бұрын
man, I was hoping you would throw the meter at something.
@Deckardsvr13 жыл бұрын
Even Stevie wonder could probe this thing ! brilliant :)
@delightful-ish3 жыл бұрын
The sharp serrated ones are sharp and serrated.
@allancollins591612 жыл бұрын
23:20 Dave didn't record the original reading correctly -- there's the human error he is trying to eliminate
@volodymyrzakolodyazhny5 жыл бұрын
He notised it - "Bloody humans" :)
@leisryan12 жыл бұрын
"Even Stevie Wonder can probe these things" epic dude!!!
@UTEPUTE12 жыл бұрын
haha even stevie wonder could probe that thing!
@CampKohler13 жыл бұрын
Suppose you fold the band back and forth to stack them up in the space, say, of 6 cm and then squash each end in a vice to which leads are attached. Then you measure all the resistors at one go to get the average. Wouldn't that tell you something without all the work?
@leocurious99199 жыл бұрын
Aurelius R said it already: You need to delete the OL as the first data entry, clearly. It's a bug in the Agilent software. I don't know how you didn't correlate that
@lematindesmagiciens87645 жыл бұрын
I am late to this party, but I would tend to agree: it was most probably a garbage character right at the start of the data file.
@EEVblog13 жыл бұрын
@Films4You The last one had OL first, and it loaded fine.
@EEVblog13 жыл бұрын
@DanFrederiksen Sure, but how many hours would you spend building and tweaking a fully automated jig vs the time saved vs the current 1.5sec / resistor?
@EEVblog13 жыл бұрын
@superdau It'll still be there tomorrow!
@fir3w4lk3r13 жыл бұрын
I think there is a GPIB to usb adapter.
@SuperAhmed133712 жыл бұрын
Four rubberized wheels at each side, driven by stepper motor, these v-shaped springs (you know, the ones with a small "coil" in the middle) to press against the resistor as probes... µC with IR diode to control stepping... !? :)
@godfreypoon51488 жыл бұрын
Six Sigma?? Isn't that where you make 6 samples of a product, put them into 6 Mitsubishi Sigmas, attempt to deliver them to a customer, and if the customer receives a product then you know the product is lucky? Especially so if the product is not ruined by oil smoke.
@BruceNitroxpro6 жыл бұрын
OMG... so bad that the joke is good.
@EEVblog13 жыл бұрын
@Systemrat2008 No reason, just curiosity!
@squeakyfromme6913 жыл бұрын
baha! knew that was gonna happen. 1000 measurements and i... can't... get... the... data!
@ElektronikUygulamalar13 жыл бұрын
this is a brilliant video!! i love it. that is a great job and i guess you are having really fun. thats great too :)
@timbdotus11 жыл бұрын
It wouldn't matter if the meter had a 50% offset as long as he tests all the resistors with the same meter. He's showing all the resistors compared to each other with a 0.3% resistor as the baseline (which read as 0.9998).
@TomLeg4 жыл бұрын
I was thinking of having an inverted V, so that however far bent the leads are, the V would capture them. You could have that serrated test pin in the middle. I would have routed or chiselled a piece of wood so the thick part of the resistor has some space, and you could test right close to it. Guess there are a lot of ways to test ...
@SirEngelmann9 жыл бұрын
am i wrong if i spot an "oscillation" in the resistor value graph?
@Satchmoeddie12 жыл бұрын
Brain fart! I love digital cameras. If you pull a stupid and forget to mark something and you can go back and see what you need to know. What is the MSRP on this meter. I like it a lot. Agilent is like Fluke for being expensive for anything that has lots of bells and whistles.
@CassegrainSweden12 жыл бұрын
If you want to interface an old GPIB-able instrument, take a look at the Prologix GPIB to Ethernet interface, it has a telnet like interface etc. that makes interfacing easy.
@esavarem12 жыл бұрын
There are also usb -> hpib/gpib converters. I have worked with one made by Agilent (Propably not cheap though)
@laernulienlaernulienlaernu89534 жыл бұрын
It should trigger and store every time the reading changes, surely?
@MickOhrberg12 жыл бұрын
@EEVblog Love you shirt - all hail the Flying Spaghetti Monster!
@pret8313 жыл бұрын
"Even Stevie Wonder could probe this thing" LOL :D Epic
@volodymyrzakolodyazhny3 жыл бұрын
Can somebody help me to reveal it a bit more? I understand the joke, but why Stevie Wonder?
@rpkamins Жыл бұрын
@@volodymyrzakolodyazhny He was blind.
@volodymyrzakolodyazhny Жыл бұрын
@@rpkamins Oh, thank you!
@lebeyes13 жыл бұрын
Dave might have to redo the 1000 measurements because I did not see him using the right tongue angle, or using his tongue at all! Or does tongue angle not matter when measuring, only when trimming?
@UpcycleElectronics7 жыл бұрын
26:58 ...or you can use the find and replace feature. Highlight the data set: Find and Replace: Search= "[space]m": Replace= [blank]. There are other ways as well such as using a function to remove a certain number of text positions from a column. Changing the data to a number format is easy as well. You can correct the format manually, or copy another cell that has the correct format, then use "Paste Special," and only paste the cell format. You can also drag the corrected cell and "Paste Special" the format down the whole column ;)
@BruceNitroxpro6 жыл бұрын
Upcycle Electronics, He probably uses Windows... can't get common things like that on Windows! (just kidding!)
@kodrawer13 жыл бұрын
Maybe you need to upgrade the meter firmware. A reviewer on Amazon said "The meters were released with substantial bugs. V2.0 firmware was released this month and corrected them. Until 11/11, Agilent will provide a free serial cable to those who ask so new firmware can be uploaded. The process of updating the firmware is straightforward and reliable. "
@we-are-electric14454 жыл бұрын
One hung low printed on that label - I don't believe it !!
@robertendl92057 жыл бұрын
A very useful trick is to plot the data on “normal” paper. You can get log-normal or linear-normal. I don’t think Excel can do that. Don’t know about Open office. This shows true Gaussian samples as a straight line. If the line shows two or more slopes then the sample population is probably made up of more than one group mixed together (made on different days maybe). If the curve as “Z” shape (three slopes) then the population probably started out Gaussian but the manufacturer could not make all parts within tolerance and had to cull the outliers.
@Meryna12810 жыл бұрын
I know this is kinda late and may have already been resolved but likely if you were using the COM port over the USB you need to reboot the computer if you disconnected it without using some sort of remove-safely program.
@evanpapp9310 жыл бұрын
I like your shirt Dave
@silverstream31413 жыл бұрын
I was expecting the redux to be 49 minutes longer...
@GGTrashes13 жыл бұрын
At 6:33 I couldn't help but notice two little blisters on your middle finger. (Damn hi-res camera...) Out of curiosity, do you know what they are? Warts?
@tohopes9 жыл бұрын
25:03 So you're the one who delayed the Platinum Chip's delivery!
@tooby9876510 жыл бұрын
Lesson: Try getting the data out when you've done a dozen test samples....nor after 10000000
@jonathanseyfert82567 жыл бұрын
tooby98765 except you know, he got the first set of 1000 points off the meter with no issues. But you probably skipped to the end and missed the fact he did the two sets of 1000 resistors separately...
@AntiProtonBoy13 жыл бұрын
Dear Agilent, Help a bro out in need. Send Dave a software patch. Regards, Anti-Proton Boy.
@mechadrake13 жыл бұрын
oh ragequit Dave :D sour about that fail software.
@razean2213 жыл бұрын
had to laugh at the end :D
@readyrepairs9 жыл бұрын
couldnt you have just drug a rig with a connector on each side down the line of resistors and recorded the entire output and then looked at the peaks as the resistance and the valleys as the non- contact ? and then measured the peaks?
@gregfeneis6097 жыл бұрын
At 4:10, You need a axial component verifier. Universal auto insertion machines used to have them back in the day.
@BruceNitroxpro6 жыл бұрын
Greg Feneis, Our firm, Quan Tech Laboratories, made test equipment for the industry that did that and MUCH, much more back in the early 60's. Now its over fifty years later and you can't buy that off the shelf? Waaaaah!
@ronaldlijs13 жыл бұрын
Hi Dave, Just one thing, the variation might be due to the temperature (and humidity!!) of your workshop, 30ºC is pretty darn hot, what's the humidity like?
@EnergeticAdvantage12 жыл бұрын
Shame it can't accept an external trigger switch, so you could wire it to a foot switch, which would probably be the fastest way.
@brandonfesser189311 жыл бұрын
Statisticians demand more statistics. Who could have predicted that?
@rich10514147 жыл бұрын
Instead of tension terminals, couldn't you use leaf sprung omron switches, which would also trigger the capture? I have a good idea in my head how to do it, but it would be tricky and time consuming to get it all aligned properly, but you could make it so the hump going over the resistor wire triggers the switches, which are hooked in series acting as an and gate, which will trigger the data logger.