Nice lookig board. Really like the tails clamp and looks like Lewden design things with functionality in mind.
@dominicdodd97593 жыл бұрын
With more and more manufacturers doing these all RCBO boards at a reasonable price I'm waiting keenly for the first plug in neutral bus bar. This would run along the top of the RCBOs, then a single 16mm wire into the neutral bar. The neutral ports are already offset forward to allow this, and it would do away with the neutral tails.
@efixx3 жыл бұрын
They already exist in the commercial world - and available for type A single phase boards. kzbin.info/www/bejne/m2aXppeVeK6pe7c - let’s hope they start appearing in the domestic world 😄
@AndyK.13 жыл бұрын
I was going to say the same. Would be great to have a neutral bar.
@dominicdodd97593 жыл бұрын
@@AndyK.1 Be great if they went the whole hog with ISOBAR and got rid of circuit wiring to protective device connections completely. You'd wire to main switch with tails, then to an 'ISOBAR' type bar with lever connectors for each circuits L, N and E. Then the devices would plug straight in.... Nice dream to have!
@dominicdodd97593 жыл бұрын
@@efixx Cheers Joe ... I had seen that, must be where I got the thought from ...
@AndyK.13 жыл бұрын
@@dominicdodd9759 See David savery ES video published today! He only gone and got one!
@alexcantley91373 жыл бұрын
Lewden make the cable clamp as STANDARD and put the price on the unit it means it's something we then cannot forget I like lewden good company 😀
@abdulseaforth69302 жыл бұрын
Hey Alex, just said the same thing.
@UKsystems4 ай бұрын
A cable camper standard may not be needed and adding it as an expense may not be worth it, especially if your Glanding in the tails it is a pointless thing
@SME_Ste3 жыл бұрын
The tail clamp gives trouble with the routing of the tails if you want to bring them directly up behind the main switch. The thought that they may have designed the new consumer unit with a little more depth in the enclosure and bring the DIN rail forward resulting in more space behind the DIN rail. Just need to find somewhere that's selling them now
@supersparks94663 жыл бұрын
Also when will we ever get a board that lines up the breakers and main switch without the lean to the right when tightening up.
@UKsystems4 ай бұрын
That would require a different mounting system, but I’ve done to the correct rating. It should not be too bad worst case put a clamp loosely across the breakers to hold them in place whilst tightening.
@MrToontownforever3 жыл бұрын
Glad they’ve moved the terminals as well, previously the live wire obstructed the screw for the neutral terminal (or the other way round, don’t quite remember). Shame I can’t find any stock locally
@efixx3 жыл бұрын
Good observation. Keep looking for stock, supply lines are a bit disrupted globally at the minute.
@majorpygge-phartt26433 жыл бұрын
Wiring has changed so much since I used to do it, I've not seen a torque specific screw driver before, I've used a torque wrench when rebuilding engines. Have you seen the CU's with dual busbars? They're well neat, no need for all those neutral leads to the RCBO's, great for TT supplies.
@efixx3 жыл бұрын
It's an ever developing industry that's for sure. Lots of interesting innovations going on.
@electrician2473 жыл бұрын
Lovely job Joe and well explained. Look a nice board.
@efixx3 жыл бұрын
Thanks Mark, that's really kind. Always a bit nerve wracking when you're putting your work up! 😊
@bhupspatel3568 Жыл бұрын
Would it be possible to know why these RCBO's do not come with an earth cable built into them?
@garethblake39413 жыл бұрын
Excellent video and commentary. l have always wonder how long it would be before double pole circuit breakers would become the norm in the UK. Keep up the good work and stay safe.
@efixx3 жыл бұрын
Thanks very much we like these a lot. 😊
@tommochelsea723 жыл бұрын
Lewden is my go to consumer unit as I only fit rcbo’s (Hagar is the best but I can’t justify the price). Nice to know they have a new model with dp rcbo’s. Hoping the price is as competitive as the old style I’ve used for years.
@efixx3 жыл бұрын
great feedback thanks
@lewden32753 жыл бұрын
Hello Tommochelsea72, We are glad to hear you are using our current range of Consumer Units and we are sure you will like the NEW PRO range!
@APHEXHEAD3 жыл бұрын
I had a comment from my inspector when I showed him a board that I had exposed the coloured insulation on the tails. He said it was bad practice, reducing the protection to single insulation. Thought it was interesting to see you do exactly as I had for years.
@100tinsoldiers3 жыл бұрын
That's crazy I always strip the insulation tails back, my NICEIC inspector has never said anything. It's in an enclosure why would it reduce protection any more than all the other cables that are stripped back inside the enclosure, don't understand their thinking.
@AndyK.13 жыл бұрын
Bad inspector
@andrewcadby3 жыл бұрын
It seems a petty observation for your inspector to make, when you consider that the busbar often has no insulation at all.
@efixx3 жыл бұрын
Yeah, that's how I've always done it. I guess the thinking on their part is that you should only take the lid off if the main switch is off so everything else is dead but the tails will remain live and so the extra layer of PVC will help. However the grey outer is technically a sheath not insulation so it's a bit of a void argument really. I think the takeaway from this is that if that's the level of stuff he's pulling you up on you must be doing a pretty solid job. 😊
@rayc15032 жыл бұрын
I've had a similar thing in the past. I couldn't understand no other inspector mentioned it to me prior to that. These guys know their stuff inside out. I tend to use the coloured tails now.
@ovieoyegwa615311 ай бұрын
Why is the SPD sitting at the end of the circuit?
@MARTINA-gc3tq3 жыл бұрын
two damaged rcbo already and two spare ways...... was a lovely chance to split the rings into radials....
@JBE3 жыл бұрын
Stunning board swap Joe 👌. 1.2 NM feels no way tight enough 😬 but if we follow the manufacturer to the letter then that's what we'll do!
@efixx3 жыл бұрын
Wow, thanks James, that means a lot coming from you! It does seem a bit low but gotta trust what they say, maybe it's because the outgoing terminals are a bit smaller than an MCB?
@AlpineTheHusky2 жыл бұрын
I never listen to the tightnes on Breakers and such since sometimes it feels WAY too little
@chandrapatel89363 жыл бұрын
How do you know it is a pozi number 2? Is there a way to check?
@richardjones31122 ай бұрын
Lovely job,nice spacious board👍.
@andysims49063 жыл бұрын
Nice informative video. One thing I find with conventional tails after tightening I always give the tails a twist once or twice as they normally work loose and then re tighten. Maybe you don’t get that problem with those more flexible ones?
@tombickerton41143 жыл бұрын
Lewden are great . My local supplier struggled with stock lately and I reckon it’s because they have changed their design lol . Still a good idea 👍🏻
@efixx3 жыл бұрын
Keep trying Tom, I'm sure they'll be back up to speed, there's issues with supply chains all over the place at the moment. 👍
@lewden32753 жыл бұрын
Hello Tom, Thanks for the feedback! We are always working proactively to keep improving our products.
@quint83083 жыл бұрын
@@lewden3275 bit if constructive criticism... I fit these as my go to boards now and have for a few years. However... the tails clamps tend to get in the way if the first rcbo and push it sideways a few mm as can be seen in this video. The spd's sit at a very slightly different angle on the din rail too almost tilting slightly upwards. And finally are there any plans to drop the control gear direct branding from the ones purchased through denmans, with stock currently up and down I'm having to use 2 wholesalers, if it was all the same it would be nice.
@Z-add3 жыл бұрын
In my country we usually have a situation where one phase is dead or is at low voltage. In that case we use a manual phase selector to switch the entire load to the good working phase. With these consumer units i don't see how you would add a manual phase selector. Any advice?
@JohnDundee-el2ro4 ай бұрын
Is all A type RCBO'S double pole and if not what are you better to use and does the built in MCB trip both live and neutral or just the live Thanks
@ianbd87043 жыл бұрын
Another great video! Thanks for sharing.
@efixx3 жыл бұрын
Thanks 👍🏻
@pluckerpick Жыл бұрын
Very good, what is the purpose/ benefit of the surge protector ?
@efixx Жыл бұрын
It's to protect your electrical equipment from transient surges caused by lightning strokes and switching of heavy loads. 👍
@abdulseaforth69302 жыл бұрын
Lewden, make the meter tail clamp part and parcel of the consumer unit- charge the extra if need be. No- just charge the extra.
@supersparks94663 жыл бұрын
When will manufacturers start making tail terminals 2 screws deep, never like the single clamp for potential 100amps
@dvrn863 жыл бұрын
that tails clamp is a great extra feature!
@andyshepherd21533 жыл бұрын
Nice video, thanks for posting. Not trying to be pedantic but are these RCBOs really double pole, do they offer overload protection on the neutral too? or are they single pole switched neutral like most other's. I know you can get double pole RCBOs but they are generally used in Europe.
@efixx3 жыл бұрын
Not pedantic at all that's a really good question, I'll try and look into it and let you know.
@lewden32753 жыл бұрын
Hello Andy! Our NEW RCBOs are Double Pole Switching but only has overload protection on the line pole. If you need any further information, don't hesitate to contact us!
@gritpipethin6 ай бұрын
Current only flows if a circuit is complete ~ break the circuit once and current will cease to flow. The isolation achieved by double pole disconnection protects (grounded) you from a higher potential on either of the supply-side conductors. There is no need to break the circuit twice in the RCBO.
@ThePlantsman2 жыл бұрын
Good video and thanks for posting. I wondered if I might ask, as it is a metal CU does the case need or perhaps benefit from an earth ? I see watching other vids that some manufacturers have allowed for this with a flying earth to a fixed attachment of the case...
@heladas903 жыл бұрын
Fuse box by CP do a double pole miniature type A RCBO for £18. Build quality is superb get a better product for cheaper than Hager.
@JohnDundee-el2ro10 ай бұрын
The price of course between Hager,Fuse box and Lewden with the seven rcbo's also you pick the Rcbo's not what they give you
@alexstone6913 жыл бұрын
Is there a reason they all have a wire builtin for neutral in? Why not use a terminal like for everything else?
@efixx3 жыл бұрын
Most manufacturers do it this way currently, a few are starting to produce boards with neutral busbars like the line ones, mainly a cost issue I guess.
@iL_Sol3 жыл бұрын
Intresting, But sorry, why powerline terminal (L) not isolated? And why not used one terminal for for N... very strange constraction. Tipe A is +
@boblewis55583 жыл бұрын
Why are manufacturers STILL only making such small boards as standard? Typical 3 bed semi with garage and utility room: 3 x lighting up, down, garage/outside 3 x rings - up, down, utility/kitchen 1 x dedicated fridge/freezer circuit on RCBO minimum to avoid false tripping elsewhere shutting off all power whilst on holiday! 1 x dedicated boiler feed 1 x cooker high power feed 1 x garage/shed power 1 x EV output 1 x solar PV connection Plus space for surge protector (WHY?? NEVER had any problem with surges and the last thing I want is total power off if there is one) Plus space for isolator (WHY?? should be an external isolator, post meter, pre CU - plus Henley block for separate feed/s to external shed/garage)!! Plus space for AFI Totally insufficient space in standard CU for all that with AT LEAST 2 blank positions spare for further /later requirements. WHAT? A whole NEW CU AGAIN!! JEEZUZ! What do you guys think customers have in their gardens ... Money trees? The actual cost of the metal box is a tiny proportion of the overall cost so fit one with space to expand. Better yet, let's junk CU's altogether and start fitting industrial style steel cabs 450mm x 550mm x 150mm with space for plenty of additional monitoring kit and home automation instead of all this ad hoc external (not so smart) technology on separate screens with zero connectivity to a computer. If anyone says something completely dumb arsed like "don't bother with ring mains , single spurs will do!" I swear I'll blow my lid! Just one 20A spur with multiple dual 13A sockets is incapable of supplying BOTH sockets with their rated feed. In a kitchen WITHOUT a ring: Kettle - 3kW Microwave - 1kW Dishwasher -1kW Toaster - 800W Fridge/Freezer (not on dedicated circuit) Cooker hood/extractor - 450W That's already over 6kW - 2 fully (over) loaded spurs without adding in other stuff also likely to be used at the same time. The only differences being: 2.5mm2 T&E cable ring main with ONE single run return to complete the ring and with headroom of 6 amps on the breaker and 50% headroom on the cable capacity Compared to: 2 x 4.0mm2 spurs to split sockets - how are you going to split them? How are you going to ensure that three heavy loads CANNOT all be connected to one spur thereby overloading it? Answer: YOU CAN'T! Hence the use of a ring for the kitchen and a ring for the utility room and play safe, for the increased cost of a few metres of 2.5mm, instead of a full run of 4mm for Upstairs power. The latter is ALWAYS more expensive!
@efixx3 жыл бұрын
Wow, what a passionate comment, thanks, there's quite a bit to unpack here but just to address the headlines. This size consumer unit filled the need for the three bed detached house that it went into leaving a couple of spare ways, of course there'll also be lots of installations that don't have as many ways. Surge protection won't disconnect the power it just absorbs the surge helping to protect the installation and equipment. You raise some interesting points on rings vs radials. I always take a case by case approach to this. I rewired my previous house with 16A radials and no problems on loading, I'll keep the ring for my kitchen when I refurbish it but recently put an A2 radial in my garage, it's about getting the right circuit in the right place I guess. 👍
@johnwaby43213 жыл бұрын
Thats looks a very smart consumer unit ... don't think you can go wrong with lewden .all depends on who stocks it 👍👍👍.
@efixx3 жыл бұрын
We love Lewden.
@bourneelectricalable3 жыл бұрын
Knipex ergo strip for meter tails. Will stop you in your tracks when stripping larger round conductors
@efixx3 жыл бұрын
I've got one of those, didn't think to use it for tails, I'll definitely try it next time. 👍
@bourneelectricalable3 жыл бұрын
@@efixx like a brand new set of crops it takes some getting used to to make sure you don't damage cores but once you get it you will find you only want to use it and nothing else
@efixx3 жыл бұрын
Nice, can't wait to give it a go!
@Clip7heApex2 жыл бұрын
Surge protector leads look tidy but being at that end of the board extends the length significantly. JW's video on the subject shows that the length should be as short as possible for it to be effective.
@rowles13 Жыл бұрын
Location of spd lewdon and verso at end of circuit ?
@johnburns4017 Жыл бұрын
They need to have a DP version of the RCBO and AFDD with a combined L & N bus bars as they have on the Continent. They call them combs. This means only one common bus bar in the case, the earth. So much easier and neater, and faster to fit.
@asp2173 жыл бұрын
You still have the ball ache of the neutral fly leads, why not make it with 2 busbars like SBS Tradesales?
@efixx3 жыл бұрын
That is an interesting product, it'll be interesting to see if the industry starts heading down that road a bit more.
@juliomaranhao3 жыл бұрын
Why do you need a sectioning device (MCB) before the surge protector?
@efixx3 жыл бұрын
They are spare ways for more circuits in the future.
@CP-du3ci3 жыл бұрын
Firstly I am not an electrician, but I do know enough not to tackle a CU change and your videos on whether my CU needs changing proved very informative. I have my CU booked for change in just a couple of week as the property I live in is now 30 years old and to be honest doesn't seem to have been wired to any specific standard to start with, although I cannot say that it is unsafe albeit unsatisfactory with todays regs. I see the main difference between the RCBO and normal RCD/MCB CU is the price. I have been quoted £600 for the CU change along with the additional works to make the installation satisfactory. I was also quoted for a CU using RCBOs and AFDDs that was £1600 more at £2200 (all prices are plus VAT). I realise that RCBOs are not yet compulsory, presumably that will be in the next edition of the regs, but I would have gone for the RCBOs had they been cheaper. I would stand maybe double the cost over RCD/MCBs but nearly 3 times just busts the budget big time at a total extra cost including VAT and the testing already completed of over £2000. I don't think that until these devices are cheaper or compulsory that many home owners would voluntarily elect to have RCBOs installed. I'll give credit to the firm that test mine installation and will doing the work changing the CU, they did not pressure me either way. As I said I know enough, and have an internet connection to find out more from your excellent channel to enable me to make an informed decision, but that may not be the case for everyone.
@efixx3 жыл бұрын
The full RCBO option you've been quoted seems a bit on the steep side. It does however depend upon the number of circuits in your home. However more circuits on a dual RCD + MCB board starts to run in to problems as you approach the limits of allowable normal leakage current which can cause nuisance tripping.
@CP-du3ci3 жыл бұрын
@@efixx Just 10 circuits in total and all but 3 are 20amp or below because of the way the house was wired in the first place. If there is any nuisance tripping the electrician will be making the 60 mile return trip to sort it
@callumBee3 жыл бұрын
@@CP-du3ci I got a 9 circuit Fusebox CU installed with RCBOs and SPD and test for £480! Whoever quoted you is looking to take you for a ride! Although AFDD are far far more expensive than just a simple RCBO so that might be why the cost is so high!
@AndyK.13 жыл бұрын
It’s the AFDDs that are driving the price. Ask for quote for RCBO only.
@TheFool2cool3 жыл бұрын
@@CP-du3ci I think you'll regret not getting RCBOs, the price shouldnt be that much higher and the benefits are numerous. No more one faulty circuit plunging you into darkness.
@bonaminhrasmey42 Жыл бұрын
What to do if you want to add a small consumer unit to your garage. 😊
@computeraddic6753 жыл бұрын
Looks lot more like we have in the Netherlands!But that cover...Will it stand open or will it be banging on your head??
@acelectricalsecurity3 жыл бұрын
I think all these boards have become like mobile phones they all look the same. I don't know if this is the case on this board, but I used one of their boards a few months ago and needed a type C for a mist system, I got a type C from the wholesalers, then found out it wouldn't fit, when i contacted lewden, they said the board was not designed to take a type C breaker, crazy.
@lewden32753 жыл бұрын
Hello Anthony, would it be possible for you to drop us a DM on one of our social media's? as we would like to find out more about this!
@acelectricalsecurity3 жыл бұрын
@@lewden3275 hi, I am one of the minority that doesn't use social media, but I had one of your boards, needed a type C, CEF gave me a type C, but it turned out it was for a three phase board, when I took it back, they contacted lewden, who said the single phase boards are not compatible for type C breakers.
@lewden32753 жыл бұрын
@@acelectricalsecurity Hello Anthony, we are sorry you was misinformed on our product offering. We offer Type C in both MCBs & RCBOs in both 6kA & 10kA, these are displayed in our literature & also on our website www.lewden.com
@acelectricalsecurity3 жыл бұрын
@@lewden3275 ok, thanks for that, I thought it strange, but I didn't check it myself, just went with what I was told by CEF and they were passing on what they were told.
@KTWElectrical3 жыл бұрын
Good video, but for me the main switch and RCBO's don't look level
@Dog-whisperer74943 жыл бұрын
Nice job well done Joe I like the look of that CU but the RCBOs are a bit on the slant , overall fantastic video mate 👍👍👍❤️
@pawelpodpora14163 жыл бұрын
Installed 2 of them last time, half of RCBOs fail RCD test.
@asp2173 жыл бұрын
Are you testing them correctly?
@lewden32753 жыл бұрын
Hello Budyn 87, would it be possible for you to drop us a DM on one of our social media's , as we would like to investigate this?
@S-Theo2 жыл бұрын
Do all the RCBOs need to be double pole ? eg Car Charger needs DB but lighting circuit doesn't . Anyone ?
@glenwoofit3 жыл бұрын
I would never install them to start with and you tightened up all the RCBO's and the main switch pissed...
@oldbutstillcurious36153 жыл бұрын
Unfortunate because the shoulder of the clamp for the tails was engineered too far to the right - no facility to move the clamp to the left. The fixing at the bottom of the switch was determined by the pegs on the busbar; so the result had to be a crooked main switch.
@robinpenny31933 жыл бұрын
Still a bit unsure about those square holes, you didn't actually demonstrate using them. I accidentally bought a Hager board with square knockouts & ended up having to buy some very expensive plastic conversion plates to turn them into round ones.
@william.winter Жыл бұрын
True double pole?
@farmersteve1293 жыл бұрын
And it's another wonky line of Lewden breakers! 🤣🤣
@farmersteve1293 жыл бұрын
@@efixx 🤣🤣 tbh I've seen a lot of skewed Lewden breakers along with Proteus & even later MK boards were prone!
@HeathenGeek3 жыл бұрын
hmm, yeh. would be nice if manufacturers made these with indents so each module could snap into the next one like (or almost like) lego
@JasperJanssen2 жыл бұрын
If you’re going to be doing rcbo-only units, the layout with those neutral wires coming off them into neutral busbars becomes *particularly* senseless. Wouldn’t it be allowed in Britain to have the type of layout more common over here, where input L and N are both on the input side? Usually accomplished with either dual input busbars or even click-in panels.
@markhardacre13 жыл бұрын
Hey my pardon but those RCBO look on a slant / is the din rail bent…
@ramzg54023 жыл бұрын
Tremendous success well done
@efixx3 жыл бұрын
Thank you! 😊
@tonyp28783 жыл бұрын
Here is challenge for you guys. Megger MFT cant do RCD 5x test on auto on Hager RCCB. I spoke with Megger, spoke with Hager. They dont know. Hager said you gotta do RCD test at the board with all the MCBs off, but it doesnt trip the RCD. What are you saying?
@asp2173 жыл бұрын
Double-pole protection is really only required on IT/TT earthing systems
@efixx3 жыл бұрын
True but it can make testing easier. 😊
@eddiepearson94233 жыл бұрын
Are these for sale yet anywhere ?
@efixx3 жыл бұрын
Just launched last week - haven’t seen any online yet.
@dominicdodd97593 жыл бұрын
I looked too, but couldn't find anything. The promo videos often get pushed out months before stock gets to distributors. The single pole RCBO goes for abour £11+VAT, which is similar to the 'tall' Fusebox RCBO - so the mini 2 pole version may be pitched at same price as the one from Fusebox, around £18+VAT. I've only been installing Fusebox for last 6 months, but will definitely give Lewden a go if it's competitive.
@lewden32753 жыл бұрын
Hello Eddie! These will be available from July!
@vicenterivera56933 жыл бұрын
Good job!
@efixx3 жыл бұрын
Why thank you!
@avreclaim64692 жыл бұрын
All those rectangular knockout are not ideal... Why don't all new board come with NO knockouts so you can cut what you need where you need it? Even a part-P sparks carries a full range of cutters, so designing your entry around pre-burst holes (often at APPAULING inconvenient spacing) is just SO 1990s, we have Starret TCT cutters, just use them! Also it is requirement to offset the RCBOs @ 15 degrees from vertical or a contractor preference? I think I'll leave Lewden (which they do well!) to make Ceeforms and use brand name consumer units, this is nearly as bad as a Hagar!
@mprelectrical Жыл бұрын
All RCBOs should have to be DP.
@mdabul71302 жыл бұрын
Ok boss niche . May practical electrical Warkar
@sjholmesbrown3 жыл бұрын
I can't believe you're still being given uninsulated busbar for your consumer units. For the sake of 50p worth of plastic after mandating more expensive metal boards for a mostly overstated fire risk. EDIT: Reached the point with the terminal shield, but point stands. You can't forget a cover that's integral to the busbar.
@efixx3 жыл бұрын
It was just a light hearted comment fella, I've never left a job without one on.
@sjholmesbrown3 жыл бұрын
@@efixx Not questioning your professionalism, I'm having a go at the manufacturers. An Australian supplier who tried to foist that off on we electricians would be pilloried, so it's up to the British professionals to tell your suppliers that naked copper is just so 1980s.
@jamesmoon56323 жыл бұрын
Wont use Lewden anymore after failing type A RCBO’s and there awful customer service. Stick to hager now less problems
@lewden32753 жыл бұрын
Hello James, Could you drop us a DM on one of our social media's as we would like to find out more about this?
@UKsystems4 ай бұрын
They are not any better a few times they have said that are failing device is not their problem anymore to various people and it’s well-known
@tc69073 жыл бұрын
I still think Lewden is one of the worse consumer unit/rcbo brands out there! Hager al the wayb
@efixx3 жыл бұрын
Have Hager launched any new innovations lately - they don’t have single module DP RCBOs.
@tc69073 жыл бұрын
Just personal preference I guess, the few times I have used Lewden if find the quality is no where near Hager! I did use fusebox the other day and I was pleasantly surprised.... maybe I should Lewden another bash 😅
@Angel_of_the_Blade3 жыл бұрын
if you'd build such a consumer unit in germany you'd lose your job! there are different standards for this kind of work...
@johnhoward21043 жыл бұрын
Always an enjoyable watch, but installing type A RCD's/RCBO's does not mean that's a problem solved. We need to be wary of certain kitchen equipment and LED lighting requiring a type F RCD (see e.g. professional-electrician.com/18th-edition/doepke-consumer-units/).
@efixx3 жыл бұрын
probably cheaper to change the appliances ! - www.cef.co.uk/catalogue/categories/rcds-rcds-2-pole-type-f