I finally got my EG4 9k DIY mini-split installed in my shed and it works fantastic. It's a nice wood framed shed with windows and insulation, etc. and the mini-split can get the temp down to the low 60's even in 90 degree weather. The efficiency of the 9k is almost unbelievable, and it's incredibly quiet.
@SignatureSolar4 ай бұрын
Thank you so much for your feedback!! Please let us know if you need any support!
@unholymans3 ай бұрын
I got the EG4 Hybrid Solar Mini-Split Kit Air Conditioner Heat Pump AC/DC| 24000 BTU It was a simple setup, also works well. When I installed my system, turned it on to check it and I had to look at the lights to make sure it was working (It was so quiet. ) within a few seconds it was ice cold coming out of the unit. Im very happy with my purchase! Install was simple. Hardest part was figuring out where to put my solar panels.
@SignatureSolar3 ай бұрын
Thank you so much for your feedback!
@RichardQuaid4 ай бұрын
I just installed one, works in concert with my central AC. It cut my electric bill by more than half in the past two hot months. Looking into getting more solar panels and adding batteries to power it and possibly a DC electric water heater 24/7.
@traciedowning85664 ай бұрын
You advertise that it's diy but if you dig... you also say the warranty is voided if a licensed tech doesn't do the install. Kind of tricky.
@tombrowncaАй бұрын
Seriously? That’s brutal.
@LarryKapp14 ай бұрын
I installed solar unit and it works good. I am wondering where the inside unit is sensing the room temperature because it always seems to cool the room much cooler than the unit temperature setting. Does it sense temperature from remote - or from a sensor on the wall hung inside fan unit ?
@mechillii4 ай бұрын
I am wondering this same thing. I installed a 24k last week and when you remove the piece that holds the wires in place on the inside, there's a free hanging wire with plastic on it. I assume this is the thermostat, but not sure. It doesn't look like it serves any other purpose. I have my unit set at 74F but it always says in the app it's 69-71F. It literally freezes the floor in front of the unit so it's like I'm in the Arctic when walking by lol. I'd raise the temp, but then the rest of the house would be too warm.
@LarryKapp14 ай бұрын
@@mechillii they say in the online manual to ignore that connector . Maybe they will answer our questions about this. Seems like something is wrong .
@SignatureSolar4 ай бұрын
The temperature of the air in the room is measured by a probe located on the head unit. This probe is situated on the right side of the unit, beneath the filter cover, and it captures the temperature of the incoming air.
@LarryKapp14 ай бұрын
@@SignatureSolar The app will show a room temperature much colder than the set temperature. This is confirmed by other thermometers in the room. So the unit should not continue to cool if the room temperature is much colder than the set temperature . I am talking about 4 to 5 degrees colder . So something does not seem right in it's controller when it keeps cooling despite room being below the controlled setpoint . This is noticed not just by me as other comment shows.
@coreygillum124 ай бұрын
I just installed the 12k mini in my off grid cabin. It is very easy, and I am impressed with the performance. The only thing I am wanting is a tutorial of the remote, and how to get the most out of its features.
@SignatureSolar4 ай бұрын
Thank you so much for your feedback! If you'd like to reach out to our tech team at 903-441-2090, we can walk you through any settings you need!
@unholymans3 ай бұрын
@@SignatureSolar The remote can be confusing, But more so the app and connecting the system to the Bluetooth devices or WiFi.... Just a thought... but Most phones have gone to 5G how are you supposed to connect to a 5g connection.
@tombrowncaАй бұрын
When are you coming out with a unit that connects to existing ducting?
@jamesabbott3052Ай бұрын
I really appreciate the in-depth video and comments. Will you be having any Christmas specials? Also, any recommendations on how to best drill through concrete block?
@antonioescutia57024 ай бұрын
What about solar panel amp rating is this a issue?
@SignatureSolar4 ай бұрын
As long as the Voltage is correct, and your wattage is good, amperage will be just fine. The Max VOC will be the most important spec to pay attention to.
@DormantIdeasNIQ4 ай бұрын
I just received my EG4 12K Solar Hybrid Heat Pump Split Unit. Your first sentence seems to close the deal, nothing more need be said. Yet you add the VOC needing the most attention? This opens a slew of questions for me. I am using the rated spec (W and V) to compute my numbers, theoretically the maximum that could occur on a perfect inclination/orientation/longitude/hot sun... that the panel will output? To place this in context: (if the answer to all 3 questions is yes, I am ok to take the chance without knowing the answers to all the questions below these 3) Say on an in series string of 2 (600W 48V) panels, plus 1 (400W 48V), I have 1600W total, and 144V total which gives me 11.11Amps. 1. I am not even sure if mixing panels with various Watts is ok, but the obvious math seems to work? 2. is that not adequate to run a AG4 12K solar hybrid A/C? RECOMMENDED SOLAR INPUT: 1000-1600W (90VDC-380VDC) 1600/90 - 18A??? - at 144V it would pull 1600W/144 = 11.11A ? may be less in eco mode? 3. and does it not satisfy charging a 3600Wh [75Ah] generator that accepts: 1600W, 11-150V, 15A on the solar input? So why use the (max) VOC? The VOC being the Voltage the panel puts out under no load? ...and is much lower than the rated Voltage. Why is the VOC the most important? In my scenario in -20F it would only pull less than 90V !? Below, I am including the solar panel specs, because I have no idea which parameter is which, as parameters are not named precisely consistently across venues, and individuals? The VOC is never mentioned as 'max' ??? ~ that tends to point to max Operating Voltage??? ...and as a noob, I would think that the Voltage that is maximum while in operation, is the one I would key on, since it is the lowest and a better choice to optimize the system... but would that be short/blind on tolerance, ranges, limits? So I don't even know how to ask proper questions. Ex: 400W rated panel 48V - (48V rated ?) Short Circuit Current: 13.79A SCC ? Open Circuit Voltage: 37.10V OCV (VOC) ? Efficiency: 23% Rated Power: 400W Maximum Operating Voltage: 31.00V - max ? lower than the rated, even lower than the VOC ??? - and why is the Operating V not 48V ? What is happening in a solar panel that causes the Voltage to not be a constant? - is it a matter of the ambient light strength that kicks in the cells to generate a Voltage dependent of that strength hence variable? ...and why it has more Voltage under no load vs under load? Maximum Operating Current: 12.90A - I guess if the charger is 15A, it fits?: - But EG4? (may draw up to18A ???) (Side note: What about the Vimp? Vmp? and all the other Voltage types mentioned?)
@CSJ-CSV4 ай бұрын
Why wouldn't the Condensate Drain line be attached to the LineSet side pre-shipping? and have the 2nd way plugged but there if needed?
@SignatureSolar4 ай бұрын
Hi! Would you mind clarifying what you mean?
@CSJ-CSV4 ай бұрын
@@SignatureSolar Why is the Condensate Drain Hose on the opposite side as the others that go thru the wall?
@SignatureSolar4 ай бұрын
Understood! This would be a question for the manufacturer. You can reach them at support@eg4electronics.com :)
@JeffinTD2 ай бұрын
I presume a rapid shutdown system is required if the PV array is on a building?
@tombrownca3 ай бұрын
at the 6 min mark you are giving #'s relative to each unit. I'll suggest you could overlay a table graphic displaying the info as you speak it. It would register in the brain stronger.
@iLikeMyChainsaw4 ай бұрын
Is a rapid shutdown system needed on the solar panels? Are there any you recommend that would work without a separate grid or off grid power solution, such as when the power is out? Is there a rapid shutdown system transmitter built into the unit?
@unholymans3 ай бұрын
Really That is a State issue, Most states Will force you to have a rss if you install your solar panels on the roof of your home.
@walkingconifer4 ай бұрын
Could you make one improvement to the solar mini split? Let the mini split send out extra power to charge a 96v battery system. The system will prioritize solar array input, but when solar input is not available, draw power from the 96v battery bank. No inverter is needed.
@SignatureSolar4 ай бұрын
Thank you for your feedback! We will forward your thoughts to the manufacturer!
@jackmontgomery31313 ай бұрын
Does the EG4 Mini Split sit level, are is it lower on on side? I used there bracket that has a level on it and backed it up with 2ft. level they both are dead on. But unit is a 1/4 in. lower on one side. is this for some sort of drain? I'm talking about the outside unit!
@cebuckh4 ай бұрын
Is it possible to run the hybrid units off of DC only? Edit: I should have said straight from a battery bank. lol
@hanklinch28334 ай бұрын
All day long with sun
@SignatureSolar4 ай бұрын
You cannot run the unit on just batteries.
@Sylvan_dB4 ай бұрын
I bet they would run from a battery if you had a battery with high enough voltage. They need from 90v to 380v D.C. That would be at least two 48v rack batteries in SERIES but I don't know of any 48v battery that can be used in SERIES because the MOSFETS in the normal BMS cannot handle that voltage. There are higher voltage D.C. systems available, but not typically to the consumer DIY market.
@cebuckh4 ай бұрын
@@Sylvan_dB yeah, I thought getting the correct voltage would be all that was needed. Thanks, I was not aware of the BMS limitations for running in series.
@elevatedsciencesllc80894 ай бұрын
@@SignatureSolar what so it can ONLY be powered by solar panels? So it only works when your array is producing enough to cover the entire load? ...dealbreaker...
@krumafreak4 ай бұрын
I want to put this on an interior 2x4 wall. Will the 3 1/2" cavity provide enough space to bend the copper lines down without kinking? Thank you.
@Sylvan_dB4 ай бұрын
It will be very tight, especially if your wall is already closed on the "outside". I also don't know how you would hang the unit with the lines trying to go down inside the wall. The "normal" install for these units is the lines go completely thru the wall which means you hang the interior unit with the lines poking straight to outside, and being outside gives you a lot of working room to carefully bend the lines down at that time.
@SignatureSolar4 ай бұрын
We have seen and ran the line sets in a standard 2x4 wall cavity, extreme caution has to be taken as to not kink the the line set.
@krumafreak4 ай бұрын
@@SignatureSolar Thank you for the response
@curtisramsey22194 ай бұрын
Your mini split use R410 and Mike said the FPA going to get rid of it. So what about the products you've sold? If they need refill? Or what is going to happen to your mini splits you have in stock?
@SignatureSolar4 ай бұрын
January 1, 2025: The EPA will set a 750 global warming potential (GWP) limit for air conditioning, which means R-410A (GWP of 2,088) will no longer be able to be used in new equipment. Self-contained HVAC systems using R-410A will also no longer be manufactured or imported after this date. However, there is a three-year sell-through period, so self-contained or packaged units can be sold, exported, and installed through January 1, 2028.
@TimMcMahon802 ай бұрын
I've got an AC/DC12C Mini-split running strictly off solar in Florida. The EG4 is probably better but mine works. The only thing that bothers me is that I am not using my solar on days when it is sunny but not hot enough to run the AC. On hot evenings I want to run it but the sun goes down so I have to use grid power. I have (5) 400-watt panels and was wondering if you had any suggestions on how to add a battery to the system. This would make a great video I think. Thanks!
@cryptickcryptick224125 күн бұрын
One method some did was to take a single circuit generator transfer switch and use that to switch it off the main circuit onto a Eco Flow solar power generator. The Eco Flow solar power generator was connected to (its own) solar panels, that power was saved in the battery. The solar power generator also has some advanced app based settings, for example, if the battery gets low, you can use AC passthrough. It is one interesting solution.
@ThunderChicken1Ай бұрын
Where is the video for hooking up a new system I have 1 12k and 3 indoor batteries bought from signature solar
@amythinks4 ай бұрын
I have a mobile application. Since I don't want to dedicate the few solar panels I have to just the air conditioner, I'm wondering if there is a way to wire it up to receive DC power from a source that isn't a solar panel...
@SignatureSolar4 ай бұрын
Just PV, you'd otherwise have to use an inverter and then it'd be AC.
@BROmanderAndChief4 ай бұрын
How long is the drain line from the blower unit? And how long is the power cord from the blower unit? Are they the same length as the 16ft pre-charged lines?
@mechillii4 ай бұрын
Yes it's either the same or very close. I installed a 24k last week and had to cut the drain line shorter. Initially, the water backed up because the drain line was dragging the ground and not letting water flow out properly.
@SignatureSolar4 ай бұрын
Drainpipe 5 ft. length x .59 in. diameter (1.5m x 15mm)
@mateopena92624 ай бұрын
fundamental question for me because my mounting template for placing my bracket is a level, I measured the bracket again and the bracket is not level is there a reason for that? #There is a loose connector gray cable and white connector where that connector connects thank
@SignatureSolar4 ай бұрын
Hi! We'd like to ensure we have all the details of your questions to answer accurately. If you'd like to reach out to us directly at engagament@signaturesolar.com with a photo of both issues mentioned and we will get those answers for you!
@mateopena92624 ай бұрын
@@SignatureSolar I installed it yesterday and had a small problem because the mold was not the same as for a 9k one and I bought the 12k one. Now it works perfectly without much noise. and I put his circuit with his service breaker 20 A
@ibenglish3 ай бұрын
Are the prices on these mini splits and EG4 inverters going to be affected by the tariffs? Or are we mainly looking at solar panels?
@SignatureSolar3 ай бұрын
It's just the panels for now
@ibenglish3 ай бұрын
@@SignatureSolar great news thanks 👍🏻
@RonaldAlvarez-or6gz4 ай бұрын
Can I run the lines from inside unit out the side and up into attic ? My wall is concrete but in attic I can run out roof sides which is wood.
@SignatureSolar4 ай бұрын
You should avoid running the lines upward, as the drainage needs to flow downward to exit properly.
@LordAncien2 ай бұрын
do you send the solar one to Puerto Rico?
@SignatureSolar2 ай бұрын
We ship overseas using freight forwarders!
@curtisramsey22194 ай бұрын
Do you sell 2,and 3 zone mini splits?
@SignatureSolar4 ай бұрын
We do not sell these at this time.
@curtisramsey22194 ай бұрын
@@SignatureSolarWell you be selling them in the future?
@glennsmith6380Ай бұрын
Do you sell cassette ceiling units with more than one head for large rooms instead of one wall unit?
@keithkelly3574 ай бұрын
Hi Kelly my name is Keith I have a eg4 mini split I installed it and turn everything on but my solar is not working am I doing something wrong
@SignatureSolar3 ай бұрын
Hi! There could be a few reasons but if you'd like to call into our tech support line at 903-441-2090, we can look into your issue and get you taken care of!
@ronhilton22554 ай бұрын
"Extreme" efficiency? How efficient are they when it comes to Heating?
@RichardQuaid4 ай бұрын
It's the same process as cooling but reversed. It should be just as efficient.
@yv75844 ай бұрын
Why do you install the drain line opposite to the line sets? All the KZbinrs move it to the same side of where the lien set is coming out.
@SignatureSolar4 ай бұрын
That is how it is packaged for shipping for protection.
@sjagain18 күн бұрын
All I want to know is how I run the hybrid solar system from a solar generator when the sun goes down. No Grid power available.
@SignatureSolar9 күн бұрын
You will just plug it into the Gen port and adjust the priority settings :)
@josephnelson28932 ай бұрын
People want different styles-ceiling cassettes for multiple zones, hidden consoles, floor or ceiling mounted consoles, and HIGHER BTU solar systems
@benc19274 ай бұрын
I enjoy our 24k Solar Hybrid Mini-Split but have noticed issues with the solar properly activating during the day. Sometimes it works and sometimes it doesn't. I have to disconnect and reconnect the solar to the unit in order to "reset" it so it will actually accept solar input. Not sure what the issues is and talking with Signature Solar has not resulted in any solution.
@pbayers4 ай бұрын
I have had similar issues as yours and unfortunately not had much better luck. Resetting the unit seems to be the best thing. I believe the MPPT unit inside the unit needs quite a bit of sun to get going.. like its charging up a capacitor and it can only do that while the unit is running on AC power. It seems if you leave the unit plugged in/ leave the breaker on for it after it has been running that it won't have that problem.. Just my 2 cents from messing with mine. They could definitely be improved, but even with the problems they have they are definitely still worth it for their cost savings.. That is if they will hold up for several years.
@lesjones44324 ай бұрын
Same issue here. Some days, it's great like yesterday where I started getting some solar fairly early in the morning (between 7:00 and 8:00). But other full-sun days I won't have any solar at all at 10:00 and I have to turn the solar disconnect off and back on to get the solar to engage.
@LarryKapp14 ай бұрын
When I was running it on just solar pv I noticed it wouldn't always start up even when it had a lot of light on the pv . I would turn it off and back on and then it would go on solar. But since then I have connected the AC to it and it works better on switching between the two - seems like it needs the AC to keep it's controller active and then can determine to start taking in solar or split the solar and AC .
@LouisFoote2 ай бұрын
@@LarryKapp1believe it will attempt to reconnect several times under low power situations. If unable it will turn off and quit trying hence the need to reset. I believe I saw this information in the manual but don’t remember for sure.
@norfloslotcar24 күн бұрын
Im soooo disappointed I bought this unit from you which is supposed to be able to run directly off solar panels but the model that I have does not have the PV connections nor PV easy disconnects. when purchasing it was not clear that there are differnt models for AC only or hybrid....its too big to ship back !
@SignatureSolar16 күн бұрын
Hi! We're so sorry you're having trouble. If you'd like to reach out to us directly at 903-441-2090, we will do our best to assist. We can provide labels and direction to ensure your return goes smoothly.