🌈❤🧡💛💚💙💜 I am one VERY satisfied customer of Signature Solar. I live off grid in a small house, and my first inverter was an 8K that gave me many issues. Signature Solar staff and tech support were amazing. Knowledgeable, patient and they helped me to troubleshoot the issues involved even though I started from knowing zero about Solar Electrical Systems. When it became clear the inverter was faulty, they stepped up and allowed me to replace it with the 6000XP inverter featured in this video. What an amazing and efficient inverter. I now have virtually all of the 110/220v power that I need to heat, cool and run all my electrical needs. Signature Solar was completely accountable for seeing that my issues were resolved and leaving me with a great inverter. Thank you Signature Solar for your great support, great company, and great customer service staff.
@SignatureSolar3 ай бұрын
Thank you so much for this feedback!! Please don't hesitate to reach out for any support in the future!
@rpsmith3 ай бұрын
Good timing! The delivery truck just dropped two of them off today! Thanks!
@SignatureSolar3 ай бұрын
Awesome! Please don't hesitate to reach out for any support!
@larrymeadows99913 ай бұрын
gonna build a new home soon, I will be calling when I start
@SignatureSolar3 ай бұрын
Looking forward to it!
@kojakdurham3 ай бұрын
Thank you so much for doing these types of videos! I find these incredibly helpful. I'm going to go with a Signature Solar kit when I am able!
@SignatureSolar3 ай бұрын
We look forward to taking care of you!
@user-nm3pp4vu7i3 ай бұрын
Another excellent training video. Keep them coming.
@SignatureSolar3 ай бұрын
Thanks, will do!
@user-nm3pp4vu7i3 ай бұрын
@@SignatureSolar Just a recommendation that would make the installation process a little simpler. If you could provide ferals for the fine stranded DC cables. I believe it would make a more secure connection for the lugs on the 18K.
@chuckb98673 ай бұрын
She looks like judy foster❤❤❤❤
@d.pollard59623 ай бұрын
Jody, but yes I agree. Kelly is awesome
@ConservativesAreDummies-gk1hl3 ай бұрын
Hahaha, I was just thinking that. Sounds like he to.
@Electronzap3 ай бұрын
Looks like a nice unit.
@URackADisciprine3 ай бұрын
It is NOT more cost effective than the Riuxu 48V 314Ah (16kWh) wall mount battery for $3K US. Not sure how long till they have their UL certs (they say soon), but when they do... Main things both batteries are missing is a good active balancer and class-T fuse.
@hicapengrs3 ай бұрын
I just saw a video of the RUIXU battery yesterday. Not sure if it is outdoor rated but even if it is not it will at least provide some extremely healthy competition to the indoor EG4. I see major price cuts in the near future.
@Showbizjoe13 ай бұрын
Can you mount this sideways if you don't have the height?
@SignatureSolar3 ай бұрын
We do not recommend this. The best orientation is either flat on its back or standing up to avoid any cell shifting or other issues.
@Scat.original15 күн бұрын
I think that price was a introduction price
@stevenfrazier89393 ай бұрын
Why wasn't the black negative power cable from the 6000xp attached to battery number two? it is important to load balance the charge and discharge of the batteries. with 600 amp bus bars that would be the correct connection.
@jsauerii3 ай бұрын
The bus bar in each individual battery while internal are separate and large enough that they are the same as if you ran both batteries to an external bus bar above them and then from that bus bar to the inverter.
@gmsgabaradama20093 ай бұрын
Correct if you can always run negative negative to one battery and positive to the other
@frankenstake9 күн бұрын
I appreciate the video and have a couple of questions. You advise turning the inverter breaker on then turning the inverter power on, and then turning the battery breaker and power on. Without the battery being turned on first, does it make sense to turn the inverter on? How would you know it's on since it wouldn't have power from battery yet? Does this assume power from grid? If the system is off-grid, should the battery be turned on before the inverter is powered up? I am paralleling three EG4 batteries to a Magnum inverter, which is not supported so I won't have communication between the inverter and batteries. I am trying to confirm the communication cable port locations for the three batteries. Is this correct? Master battery - Comm Port Second Battery - in from Master at Battery port, Out at Comm Port to Third Battery Third Battery - in at Battery Port.
@SignatureSolar8 күн бұрын
The reason you turn the inverter battery breaker on first is to limit inrush current for the battery's built in Pre-charge resistor; not doing this will often create a short at the inverter's battery input from high inrush. No need to run any communication cables at all, even between batteries, if they aren't going to communicate with the inverter.
@frankenstake8 күн бұрын
@@SignatureSolar Thanks much, that makes perfect sense! I was wondering why batteries in parallel would need to have communication since the parallel arrangement in itself should keep them balanced. Now, if I could just get the batteries to arrive, I'd be in business! Thanks again!
@marcellowithtwolsАй бұрын
Hi Kelly, would it make sense to connect the inverter battery leads to both batteries instead to just 1 battery? (so that all batteries are the same distance to the inverter). Example: Connect inverter negative lead to battery 1, and positive lead to battery 2, then parallel the batteries with the paralleling cable as per usual?
@SignatureSolar29 күн бұрын
Hi! -With 2 batteries - you can parallel them to each other and then run the cables from the master battery (the PowerPro has a 600A internal busbar that will allow this to happen successfully. Server racks or more than 3 PowerPros with a singular inverter, we recommend using an external busbar.
@richardservatius54053 ай бұрын
I already have 5 rack mount 5kwh batteries hooked up to a EG4 6500 hybrid inverter/charger. I want to eventually buy another eg4 6500 for 240vac for charging an EV. I presume that I should just hook up a wallmount 14.5kwh battery to the second eg4 6500, not parallel all the batteries?
@SignatureSolar3 ай бұрын
If you add a second 6500 in parallel, they absolutely have to share the same battery bank
@user-jw3bi7hf1y3 ай бұрын
I bought the 18k and two indoor wall mount batteries package. Still in the box. Because it came as a package, does it come ready to parallel the two batteries?
@SignatureSolar3 ай бұрын
Yes!
@marcellowithtwols3 ай бұрын
Ok so I have two of these now. Which part number do I need to correctly terminate the included wire so I can connect the two together? Thx!
@SignatureSolar3 ай бұрын
You shouldn't have to terminate anything. The communication cables between the batteries will be a straight through CAT5/6 cable, and it will run between Bat/Com ports on each battery
@marcellowithtwols3 ай бұрын
@@SignatureSolar Sorry I meant BATTERY cable. they come with a Degson connector on one end, unterminated on the other end. Each battery came with 2 of these thick cables, and I don't want to buy another set "paralleling kit". So I'm using some basic awg0 splicers until the new degson ends show up. Thx
@linkinanytime3 ай бұрын
Hello- do the 2 batteries need to have the same SOC before we parallel connect them?
@SignatureSolar3 ай бұрын
It is always best to have your batteries as close in SOC as possible
@justanotherdillhole7824Ай бұрын
hi can you address this tid bit im concerned because i purchase an eg 4 6000xp and the the 280 ah bat.then came across this -"6000xp is not UL9540 certified.
@SignatureSolarАй бұрын
Inverters are UL1741. UL9540 is listed as an ESS system kit.
@jellybeanjellybean-tn2lm2 ай бұрын
Approximately how long does it last?
@SignatureSolar2 ай бұрын
It is rated for at least 8000 Cycles at 80% D.O.D!
@angloblaxon3 ай бұрын
So i can hook this up to a growatt gridtie min model?
@SignatureSolar3 ай бұрын
No, the Growatt grid ties we sell need like 500V batteries, Growatt ARO batteries.
@penrodautorepair31703 ай бұрын
Will this battery work with a rich solar Nova 6000 W inverter
@SignatureSolar3 ай бұрын
If there is a lead acid option that can be run in user defined, you can input charging parameters