EICR coding for Industrial installations with Neil Bridgeman and Paul Meenan

  Рет қаралды 3,978

SparkyNinja

SparkyNinja

Күн бұрын

Пікірлер: 11
@SparkyNinja
@SparkyNinja 4 жыл бұрын
You guys can catch Neil offering more great advise and talking off-grid here: kzbin.info/door/TVRqeTmcEdgzp2ZKMh-97A
@neilbridgeman7768
@neilbridgeman7768 4 жыл бұрын
Thank you for inviting me to take part. Very enjoyable and a great debate.
@JwiseTheRealist
@JwiseTheRealist 4 жыл бұрын
Interesting video ... Good to see others' perspective
@pauljones908
@pauljones908 4 жыл бұрын
So if TN-S systems are to be classed as PME due to the DNO converting them without knowing what happens to petrol forcourts that require to be a TN-S under the ATEX regulations?
@e5Group
@e5Group 4 жыл бұрын
Are they not TT for ATEX? Thought they were supposed to be. We will cover this next week.
@pauljones908
@pauljones908 4 жыл бұрын
No they can be TN-S as well but not PME incase of a loss of neutral which you wouldnt want on bonded fuel tanks as it will give it enough energy to cause ignition
@e5Group
@e5Group 4 жыл бұрын
Paul Jones I thought that was why TT. Remove spark potential. We will delve into it in future webinars but the ENA doc G12 is a good doc to start with.
@pauljones908
@pauljones908 4 жыл бұрын
@@e5Group thanks ill give it a read. Im just going off previous jobs ive had on petrol forcourts and they stated TN-S and TT were the only acceptable means of earthing. I currently work in the water industry now and we have our own 11KV-415V TX feeding our ATEX equipment and that is a TN-S arrangement (Although you could argue its a TN-C-S but not PME)
@e5Group
@e5Group 4 жыл бұрын
Paul Jones if you have your own Tx it is defined as TN-S pretty much only TN-S left now. It’s covered in various docs we have screenshots of sections on our Instagram page
@jackcole2347
@jackcole2347 3 жыл бұрын
Is it classed as Acess to live parts if everything in the junction box is IP2X but doesn’t have a lid? So the single cores with basic insulation can be touched?
@rattlehead85
@rattlehead85 4 жыл бұрын
Great content as always guys. We need you to keep doing this to kick the scheme providers and managers alike up the ass and wake them up!!
Electricity at Work Regulations - A SparkyNinja Webinar
2:50:58
SparkyNinja
Рет қаралды 7 М.
EICR Coding: A SparkyNinja Webinar
2:13:36
Team Electrical, e5 Group
Рет қаралды 8 М.
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
Diverted Neutral Current
1:14:19
SparkyNinja
Рет қаралды 6 М.
7 Reasons Why Your Home Might Fail an EICR Inspection!
1:05:42
Artisan Electrics
Рет қаралды 91 М.
SparkyNinja/e5 webinar - BS 7671 vs EaWR - Round 1
2:02:04
SparkyNinja
Рет қаралды 2,4 М.
Plane Breaks After Landing Too Hard
8:02
lucaas
Рет қаралды 139 М.
How NOT to Perform an EICR: Lessons from a Bad Inspection
14:43
Artisan Electrics
Рет қаралды 31 М.
Hidden danger in service cut-out fuses - Phenolic degradation
58:40
EICR failure site - righting the wrongs
24:48
David Savery Electrical Services
Рет қаралды 67 М.