Coach thanks for the free knowledge that makes our lives more valuable
@antoniocampuzano2546 Жыл бұрын
Thanks a bunch coach makes me more knowledgeable and confident when I’m out there in the field.
@ernestochavez1968 Жыл бұрын
Thank coach. Great info. Blessings from Avenal Ca.
@jimmylinear8426 Жыл бұрын
Great stuff coach ❤
@ronbonick4265 Жыл бұрын
Coach I wish you would put out more info on bonding water pipes and gas lines also here in TN - the state is asking/requiring a bonding jumper inside the panel from ground bar to ground bar is its a 4 wire and there are 2 ground bars ( like I put a bar on each side of the box ), Cost maybe $10 more but IMO it sure makes the job look better ( gooder)
@ElectricalCodeCoach Жыл бұрын
Are you using these ground bars as neutral bars as well? are you attaching the bars using one of the methods listed in 250.8?
@paulcoulston1987 Жыл бұрын
The confusion about panel height comes from old timer's like me. When I started in the late 1980's all service panels had a up/down configuration for the main breaker which was always on the top of the panel. So we always made sure that this breaker was not higher then 6 ft 6 then later 6 ft 7. Then in the early 2000's the horizontal main breaker panels came out so we had to rethink that. It took the old timers a while to GET IT. If you installed a panel with the main on the bottom like you said in the video top breaker knockout not higher than 6 ft 7
@damazon79 Жыл бұрын
Thank you for the knowledge!⚡️
@-757- Жыл бұрын
Thanks
@MattSteiner-if5md Жыл бұрын
Your content is great Thanks
@SquirrelsForAll Жыл бұрын
Great video, thanks. Question for you... Installing an outlet near a toilet for a bidet? What are your recommendations regarding the NEC's requirements on distance and placement. Thanks!
@jorgehuizarsr8519 Жыл бұрын
Thanks 🙏 coach From Southern California fountain valley California ✌️👌
@alldayjack4830 Жыл бұрын
With a meter/disconnect, is the inside panel treated as a service panel or a sub-panel?
@alvilla701 Жыл бұрын
Why THHW and XHWN are in the 75°C and 90°C column in Table 310.16?
@ElectricalCodeCoach Жыл бұрын
Great question! They are rated for both
@Electrician_kenz Жыл бұрын
Great detail, 👍
@kc1782110 ай бұрын
Very informative
@ElectricalCodeCoach10 ай бұрын
Glad it was helpful!
@ramonfigueroasalcedo4441 Жыл бұрын
greetings could you explain the question. For a feeder tap not exceeding 10 feet in length and field installation,the maximum overcurren device rating supplying a tap conductor with an ampacity of 40amps is-------? article240.21b(1) (4)
@zackmilligan1261 Жыл бұрын
Don't you love panel schedules that are labeled evens and the breaker numbers are laid out on odds