Electrician: "Whoever did this job, did it wrong" | Industrial Unit Electrics

  Рет қаралды 9,792

Eastway Electrical

Eastway Electrical

Күн бұрын

To hire Eastway Electrical for work in your property please visit our website:
www.eastwayele...
Social Media links:
Linkedin: / delroyjames
Instagram: / eastwayelectrical
TikTok: / eastwayelectrical
To help me create content more consistently, upgrade equipment you can support via PayPal:
paypal.me/delr...
Timestamps:

Пікірлер: 29
@blackdotkiller1
@blackdotkiller1 5 ай бұрын
You answered your own question, don't glue in case of alterations 👍
@oliverdaley934
@oliverdaley934 5 ай бұрын
after years of having know it all sparks work on our projects, its very nice to see someone competantly tackle a variety of work with care and consideration.
@clairefitness2140
@clairefitness2140 2 ай бұрын
I used to call it a coupler but it's a bush adaptor. I don't glue tube as you can alter it easily then. I hate when I have to change something and it's been glued. Love your videos by the way.❤
@davidainsworth
@davidainsworth 5 ай бұрын
The conduit ends are called adapters (male and female). It’s regulation now to use metal saddles on plastic conduit.
@josephking6515
@josephking6515 5 ай бұрын
You do nice work Delroy and very good explanations/directions to your apprentice, well I hope he's your apprentice because he has a good teacher to start him on his profession.
@001Neal100
@001Neal100 5 ай бұрын
That workshop looks like it's a trip hazard nightmare trying to move your ladder around that place with all those shelves and boxes everywhere!
@ifiwasanelectrician2802
@ifiwasanelectrician2802 5 ай бұрын
Think the smaller knockout is for a strain relief if you're planning to use low voltage dimming. At least in Canada anyways.
@chrisardern4594
@chrisardern4594 5 ай бұрын
The plastic conduit and fitting will have a high melting point thus meating the non collapse regs and also non toxic when heated. As for having the switch cable running from the first light throught to the second light this would be acceptable unless the lights were switched independently.
@ashleyrussell4288
@ashleyrussell4288 5 ай бұрын
Which is going into a plastic red rawl plug... 😂 Don't see what's the point in putting metal ones up
@DaveJaJemTV
@DaveJaJemTV 5 ай бұрын
I have this debate all the time with sparks about key switches. From my understanding the key switch is there to simulate a power failure so it should kill the circuit completely not just the emergency feed
@edh4808
@edh4808 5 ай бұрын
But then you're causing a hazard to anyone in the facility?
@dazdaz105
@dazdaz105 5 ай бұрын
I wouldn’t bother glueing conduit. On another note surely plastic conduit fastened to the ceiling is no use in a fire. Isn’t that why we now use steel cable ties ? That conduit is over a fire exit. The electrical rule book is forever being tested 👍 As an ex facilities/maintenance engineer I’ve seen all sorts of stuff, I’ve seen stuff done wrong that has actually been safer than things done right !!!
@ashleybignell2366
@ashleybignell2366 5 ай бұрын
i thought he said he used white metal saddles on the ceiling as suggested by his wholesaler. He would normally use white plastic. Metal saddles would be fine to hang the cables if the plastic conduit were to melt in the event of a fire.
@m00dyCharts
@m00dyCharts 4 ай бұрын
bush coupler. Bush one end, coupler the other, clever huh!
@Mattja1
@Mattja1 5 ай бұрын
I'd not glue plastic conduit that's inside a building, no need and makes it harder to make alterations. Running black plastic conduit outside I use solvent cement to both glue and seal it against water ingress (drain hole at each box etc it connects to).
@lucastaylor23
@lucastaylor23 5 ай бұрын
Why you fitted all the arrows on that emg bulkhead?
@inspireG380
@inspireG380 5 ай бұрын
Makes sense to glue conduit outside to help make it water tight. But really can't see any benefit from doing it inside ?
@madogapllywelyn2254
@madogapllywelyn2254 5 ай бұрын
Yes I agree only glue if outside is a must as the conduit these days seems not to fit tight Had a job recently where the newly installed outside lights around a communal building was tripping and most of the lights where full of water as they took the conduit in top and didn't glue it
@inspireG380
@inspireG380 5 ай бұрын
@Walktheline1991 if it's fitted properly, shouldn't be an issue, really. Am I 'half sharp'? No one likes a keyboard warrior. Pipe down
@aaronshort577
@aaronshort577 5 ай бұрын
Your socket & bush is called female or male adapter
@trevorsmith5946
@trevorsmith5946 5 ай бұрын
I always called them couplers
@s.kxx1956
@s.kxx1956 5 ай бұрын
Seriously why glue it ? It’s not a plumbing pipe with potential to leak under any form of back pressure. Just makes things harder like here when you need to alter it. Using pipe adhesive achieves nothing, if your worried about it all coming off then that wiring system is the wrong type for its purpose
@ukmal67r81
@ukmal67r81 5 ай бұрын
I stopped gluing conduit as when it heats up it needs room to expand otherwise you get the snake effect on the wall.
@dd7774
@dd7774 5 ай бұрын
👍🏼
@craigrobertsonmsc.6260
@craigrobertsonmsc.6260 5 ай бұрын
Cooshtie.
@tonywatson1412
@tonywatson1412 5 ай бұрын
Whats with all sparkies and gloves these days.... don't wanna get your little hands dirty hmm 😞
@edh4808
@edh4808 5 ай бұрын
Get less of a belt
@Zak-ku7sq
@Zak-ku7sq 5 ай бұрын
Yes and it's safer also
Electrics in an outdoor kitchen extension
22:41
Eastway Electrical
Рет қаралды 8 М.
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 45 МЛН
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН
How do Cats Eat Watermelon? 🍉
00:21
One More
Рет қаралды 14 МЛН
My Daughter's Dumplings Are Filled With Coins #funny #cute #comedy
00:18
Funny daughter's daily life
Рет қаралды 28 МЛН
Skill Builder Devastated by Tool Theft | What Went Wrong?
8:40
Skill Builder
Рет қаралды 50 М.
"THIS is stopping me from doing my job"
10:10
Eastway Electrical
Рет қаралды 10 М.
Single To Double Socket Change | Delroy The Spark Full Process
26:34
Eastway Electrical
Рет қаралды 20 М.
Intermittent Tripping: These Faults Are The Hardest To Finds
12:49
Eastway Electrical
Рет қаралды 20 М.
New Build Without Enough Sockets
11:32
Eastway Electrical
Рет қаралды 12 М.
Electrician on a job with a confused customer...
15:41
Eastway Electrical
Рет қаралды 13 М.
Unhappy Customer?
11:18
Eastway Electrical
Рет қаралды 44 М.
EXPOSING SHOCKING ELECTRICAL WORK... EV INSTALLS AT THEIR WORST!!
10:13
SOTA Electrical
Рет қаралды 75 М.
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 45 МЛН