Electronic expansion valve

  Рет қаралды 12,041

What would Dennis do

What would Dennis do

Күн бұрын

Lets have a brief look at a more common type of electronic refrigerant flow control expansion device. The 4 phase linear pulse valve is very basic in its design but offers much needed flexibility and precise superheat control. This stepping motor type is now seen on both air conditioning and refrigeration systems. Many are apprehensive about working on or servicing them, the idea of this video is to show you how basic they are in principle

Пікірлер: 19
@haidymorine3024
@haidymorine3024 5 жыл бұрын
Thanks for sharing,pls keep them coming.
@fadikhaleel6941
@fadikhaleel6941 5 жыл бұрын
Good job ....waiting for another video
@kimcramer2845
@kimcramer2845 5 жыл бұрын
Nice work Dennis, very informative
@tommyq374
@tommyq374 Жыл бұрын
Im actually just here doing some research into making a portable driver tool for testing these, the eevmate is cool but dear and in usa where i am not so not sure if they ship to northern ireland, really having a nosy at your setup in the back lol
@LC-qi5ff
@LC-qi5ff Жыл бұрын
Please make a vid if you make any progress!
@tommyq374
@tommyq374 Жыл бұрын
@@LC-qi5ff ive made strong progress works on Toshiba and daikin eev coils so far, havent tested other brands just yet, but unsure what Im gonna do with it, might make some and sell them possibly
@LC-qi5ff
@LC-qi5ff Жыл бұрын
@@tommyq374 as long as its not for a ridiculous price like eevmate et al !
@tommyq374
@tommyq374 Жыл бұрын
@@LC-qi5ff definitely not as bad as $200 lol and like $40 for their cables no offense to them
@nisanthamuhandiramalage4872
@nisanthamuhandiramalage4872 3 жыл бұрын
Thanks
@greggie111
@greggie111 3 жыл бұрын
Great video. What sound do they make when you first switch on the air con and they initialise? I have a problem with a mini split air con freezing. Most likely low on refrigerant, but want to check the EEV before I call a licensed technician. My EEV makes clicking noises for 2-3 seconds when the unit is powered on. Is that expected?
@whatwoulddennisdo7243
@whatwoulddennisdo7243 3 жыл бұрын
Yes thats correct. You will hear a ticking sound durining initialisation from power up. The valves motorised head receives more closing pulses than usual to ensure it starts off in the zero step or closed position. The pcbs do not remember which step they were on during a power up
@azazizazi8861
@azazizazi8861 Жыл бұрын
yes
@utube321piotr
@utube321piotr 4 жыл бұрын
It's like fuel injection vs a carburator
@TheS4akella
@TheS4akella 4 жыл бұрын
Nice
@fridgydownunder6734
@fridgydownunder6734 3 жыл бұрын
EEV can do up to 500 steps
@whatwoulddennisdo7243
@whatwoulddennisdo7243 3 жыл бұрын
Danfoss and Carel work on 480 pulses in refrigeration to fully open , so 480 steps. Some aircons can be higher which increases the range of closer capacity control..
@mujeeb7100
@mujeeb7100 2 жыл бұрын
Fujikoko make goes upto 2500 steeps for daikin and Samsung. Below 1000 steps refrigerant is sufficient and above 1000 to 2000 refrigerant is inadequate. 2500 steps for recovery and vacuum mode.
@aminaziz944
@aminaziz944 3 жыл бұрын
Why you stop making new videos
@genevasimmonds8208
@genevasimmonds8208 4 жыл бұрын
Nice
Electronic Expansion Valve - How it works ETS 5M HVAC
13:41
The Engineering Mindset
Рет қаралды 362 М.
路飞被小孩吓到了#海贼王#路飞
00:41
路飞与唐舞桐
Рет қаралды 76 МЛН
Beautiful gymnastics 😍☺️
00:15
Lexa_Merin
Рет қаралды 12 МЛН
КАК ДУМАЕТЕ КТО ВЫЙГРАЕТ😂
00:29
МЯТНАЯ ФАНТА
Рет қаралды 8 МЛН
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 7 МЛН
Why a Hard Shut Off TXV Closes
5:57
HVAC School
Рет қаралды 17 М.
HOW TO TEST DAIKIN EEV COIL.
12:23
Mitch Attwood
Рет қаралды 13 М.
You're wasting money on heating! Use your A/C!
17:11
Tech Ingredients
Рет қаралды 392 М.
How EEV works - Electronic Expansion Valve working principle, HVAC Basics
8:33
The Engineering Mindset
Рет қаралды 400 М.
We exposed BEEF to the vacuum of space, then ate it!
49:28
Tech Ingredients
Рет қаралды 350 М.
Elektroniczny zawór rozprężny
1:09
GGG
Рет қаралды 2 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 48 М.
Troubleshooting Trane EEV and EVC Board
7:49
Zack Talks Shop | B-Side
Рет қаралды 82 М.
Defeating Microwave Weapons! - Part 1
29:28
Tech Ingredients
Рет қаралды 1,1 МЛН
路飞被小孩吓到了#海贼王#路飞
00:41
路飞与唐舞桐
Рет қаралды 76 МЛН