The moment you walked back into the lift room and saw the motor turn over - That is ETO candy. The feeling of fixing the problem is why I love this profession. Nice fix!
@leckyjake3 жыл бұрын
Thank you. It is the satisfaction. I just can't explain that feeling. Safe sailing
@pedroveloso97073 жыл бұрын
kkkkk ohh yes, a few understand well that ..."yeeessss...." ..
@srivatsavmattaparthi49153 жыл бұрын
Well that is the reason im preparing to for ETO ❤️
@Heisy01982 жыл бұрын
As a Elevator Troubleshooting Technician, it's like a drug. You get addicted to it. It's weird because you start looking forward to breakdowns like these!
@jackburnell32093 жыл бұрын
It must be nice working in an environment where every device is labeled and has a manual.
@danielelise73483 жыл бұрын
I like your methodical approach to fault finding,I see a lot of guys just panic & say "lets try this,lets try that"just slow down & work through it.Another one in the bag,good job.
@dwaynes59832 жыл бұрын
I start at beginning. Sometimes missing one phase.
@dirkcanyow Жыл бұрын
Your ability to remain calm is impressive.
@ferdinandorigenes67902 ай бұрын
Kudos... Kelan ko lang napanood videos nito sa fb... Marami at buhay pa rin sa pagbibigay ng knowledge at inspiration... 👍👊Salute sir and to madam as your moral and happiness support... Fb followers here... Tnx...
@DEW4093 жыл бұрын
You always get to the problem logically. Great skills!
@leckyjake3 жыл бұрын
Thank you.
@alexanderkupke9203 жыл бұрын
I am working in IT, but for the logical approach of troubleshooting I am indeed considering recommending this to some colleagues who seem to completely miss any logical or structured approach to diagnosis and troubleshooting.
@christhackrsy3 жыл бұрын
Impressed by your logic and natural ability in your job, if you ever dock in the uk let us know in advance I’ll buy you a beer
@johncantrell6143 жыл бұрын
Yup, there are times that in troubleshooting, I also call it “chasing the rabbit”, that you have a hard time catching it. But after spending sometimes a long time trying and finally getting the problem, or “catching” the rabbit, that feeling you get afterwards is the reward for all the hard work spent tracking it down. Good video, thanks for sharing!🙂
@KutWrite3 жыл бұрын
I just had that feeling with my #1 computer at home. My external backup drive for odd months was intermittent - hardest problem to fix. Switched drives, then power supplies (which never break). Of course it worked as long as it sat idle. Mid-backup (2 hour job) it would fail, and... yes... it was the power supply (wall wart). I didn't have that voltage as a spare from my parts box. I had to order one, so I ordered two to have a spare. Four days later with a new PS, it worky-worky! Yay! I also get that feeling when solving software problems, which even occur on my Linux system... usually after a major update.
@bigmedge3 ай бұрын
Hi Jake, thank you for providing such a thorough & methodical tutorial !! 3 questions plz sir: 1. @ 4:40, for determining that all the CPs have supply voltages, did you check for voltage by placing the multimeter’s red lead on each CP’s power pin & black lead on a chassis ground ? 2. What was the thought process that led you to make the correct assumption that it’s relay MCA, rather than contactor MC, that’s the faulty component? 3. I understand why you checked for 24v be tween P24 & N24 on either end of that circuit; but from the wiring diagram, it looks like A220 & B220 are on different circuit legs, so why was there 220v between them?
@CoolinRaza11 күн бұрын
The Joy after completing the Job😎❤
@rockie62203 жыл бұрын
bro I respect you.so many problems you never seen before you can fix it
@leckyjake3 жыл бұрын
Thank you very much
@muradcahangirli81495 ай бұрын
Thank you so much for giving us some useful. You are a MAN !
@TheLusus3 жыл бұрын
Sticky relays are so common. 🤣 First thing to do is to tapp on it lighty with a screwdriver handle to unstick it. Or just manually bridge the terminals for elevator call to be able to hear if the relay clicks when it powers on. 🙂 Best wishes, a Swedish Marine electrician. 🤜💪
@dragonfireproductions7903 жыл бұрын
I'm an electrician but not a marine one. I use the F*ck stick(a screwdriver) and slap the relay. I call it the f*ck stick because you'll swear like hell on one if you get frustrated
@jamesmaida473 жыл бұрын
Very cool, videos like this are my favorite. You identify an issue, investigate possible causes, test following schematics and solve the problem. I just found your channel in the last week or so and I watch evey video of yours that pops up.
@eyadalsaadi3 жыл бұрын
Hello Mr. Leckyjake, First of all my name is Eyad, am working as electrical engr. (earlier as marine side and recently on electro mechanic Contractor). really appreciated your effort for proficiently on troubleshooting as well as your videoed explanation. i have some clarifications and very important to understand and need your reply once you are free for that. i will start with your video on Reverse Power Trip on Genset#4 and your act by replacing VCB#3 instead VCB#4 and vise versa after RUN genset#4 (with health VCB#3) founded same problem (reverse power trip VCB) occurred again so your solving problem by opening VCB#4 (ITS NOT UNDERSTOOD FOR ME) as I assumed if still revers power activate even with other VCB SURELY its NOT DUE TO VCB AT ALL , AND COULD BE FROM GENSET SIDE. sorry for long message but really i would like to know the correct . ALL RESPECTFUL FOR YOU AND YOUR FAMILY.
@kem-zq8si11 ай бұрын
That relay was reading good, howcome you didn't assume the contactor was bad? maybe some of you other guys can respond, i am curious.
@alexpornes71822 жыл бұрын
Hahhaa happy reaction sir. Napa yes!!! Hahhaa. Kakaba lang ang board or PCB
@leckyjake2 жыл бұрын
elevator is like part of the necessities onboard. if you can't fix it, all eyes are on you.
@alexpornes71822 жыл бұрын
True deck and engine are always eeying on lecky. That's the challenge for a lecky.
@jiouse58812 жыл бұрын
Very clear and informative. We have installed one local brand elevator in our building. It got damaged by lightning strike and that company is dead now. I am sure that something is wrong in the control board but the wiring are too messy; no label, no colour code or numbering. Beside that no document or service manual. Now I don't know where to start.
@hclee99902 жыл бұрын
낙뢰로 인한 고장은 보호회로가 약한 인버터 고장 일 수 있습니다. 인버터 전압 출력부터 확인해 주세요
@mohamedroomy19853 жыл бұрын
Bro really you are doing a great demonstration, real troubleshooting. Sure it will serve many of us. Priceless effort
@al13153 жыл бұрын
11:33 that feeling when you solve the problem ☺️ thanks for another learning
@leckyjake3 жыл бұрын
Hahaha it is like solving the puzzle and gives you all the satisfactions once solved it. Thank you for watching
@cliff34353 жыл бұрын
its the most fullfilling feeling for a technician good work
@arvinkarldagot4100 Жыл бұрын
that moment when you see the motor running! thanks for this learning! :)
@geselbahatan98192 жыл бұрын
more power to you Leck for sharing knowledge for free.
@leckyjake2 жыл бұрын
Thank you for the support
@briwire138 Жыл бұрын
I shared that moment when the motor ran. Great job.
@leckyjake Жыл бұрын
thank you
@akshayrathore56733 жыл бұрын
jack i have a doubt, at 7:24 when u r checking relay MCA , if the relay is working properly and we measure voltage across P24 and N24 shouldn't the voltage reading be zero ? what i mean is since we are getting 24Vdc(26 in ur case) doesn't that indicate the that circuit is open somewhere ?
@michaelardai97033 жыл бұрын
P24/N24 power the relay coil. The contacts are on the 220v side and pull in the MC contactor
@leckyjake3 жыл бұрын
Thanks
@unobono2 жыл бұрын
@@michaelardai9703still cannot understand. Shouldn't it be zero between p24 and n24 because the relay is activated?
@unobono2 жыл бұрын
@@leckyjake still cannot understand. Shouldn't it be zero between p24 and n24 because the relay is activated?
@RakeshChaubey-s3s Жыл бұрын
You are legend thanks lucky sir ,I learned lot of thing's from you
@johnvergillopez69543 жыл бұрын
Best feeling is to fix this kind of problem. kudos sir!
@marianobulaong58543 жыл бұрын
Super hard working in trouble shooting . Keep safe always Jake . Im also electrician/Refrigeration and Reefer van technician
@princeoffame1002 жыл бұрын
What kinda controller you are working on you have it very Good to have a book explaining everything to you ....
@henz24halfliyf463 жыл бұрын
That "yes" word.. Hehe thank u for the upload Sir. Looking forward for more videos. Safe sailing Sir,!
@leckyjake3 жыл бұрын
Thank you
@25denzil3 жыл бұрын
Awesome job. You are really the man of the hour 🙌🏻
@leckyjake3 жыл бұрын
Thank you for the support
@luhlafa2 жыл бұрын
Very good man. You are the best! I am a electrician trainee in a maersk vessel in Brazil . But the company called Aliança ( from a group of maersk). I am a problem f22 in a similar elevator.
@keything84872 жыл бұрын
we usually tap on relays to see if they engage.......good video
@jesonabejuela37372 жыл бұрын
Slamat po sir Sa video, marami akong natutunan.
@ivanfmartinezm Жыл бұрын
I didn't understand how you found the problem???? Electrician never guess only check the voltaje secuence in the contact mca because there are several contact relays for safety or interlock until be activate the main contactor MC, in spite of the coil from the relay you changed was working properly maybe or i suppose the contact was broken so that the circuit was open or interrupted in that point. The only way to be sure why the main relay was not activating is checking in the electric diagram all the contact one by one in the ladder diagram begin for the main voltage making sure there are voltage present from the one contact till the last, each one involve in the start secuence of the main contactor MC which is responsible to run the Electrical Motor. Good Job!!!! Amazing i'd like to see in next video a out the frecuency driver from motor or if maybe in that case don't use any only main contactor, because i worked in one elevator with two speed motor directly start.
@taras.protsenko3 жыл бұрын
You are very simply bring information. Thanks
@leckyjake3 жыл бұрын
Love to spread the love
@vishalkumarmaurya39583 жыл бұрын
I am always waiting for your video sir Thanku soo much 💓💖
@leckyjake3 жыл бұрын
Thank you. Very much appreciated
@charachara15033 жыл бұрын
Great man. .thanks. For helping others. Ur. Hero
@leckyjake3 жыл бұрын
Thank you for your wonderful comment
@eyadalsaadi3 жыл бұрын
thanks for your kind attention really appreciated and please go ahead (full ahead not to ASTERN) and good luck for everything and last i excuse for other remarks could i highlighted ? thanks for everything and good luck
@andrewtaylor96153 жыл бұрын
I had my money on the door obstruction sensors! Nice work.
@elevationtechvlog34742 жыл бұрын
Hi.... i apprecaite...you are my idol in trouble shooting of elevator...and you are using schematic diagram...
@johnvergillopez69543 жыл бұрын
Good job sir finding the trouble and rectify it. More power!
@brainstorm773 жыл бұрын
This was a great shared experiences ,if you are able to make more videos from this content I would be verry thankful and not only me I think! Keep develop you account.
@leckyjake3 жыл бұрын
Thank you for your support
@michellewu0019642 жыл бұрын
Your video is really good, thank you for your help, it's really helpful, thank you again
@renelemueli.ochenta88373 жыл бұрын
Ayuz. Tnks boss big help talaga yan.
@cck14963 жыл бұрын
Good video. At 11:53, what are those plugged in items on Magnetic contactors? Thanks.
@alexanderkupke9203 жыл бұрын
I am not entirely sure about those specific ones, but I think those might be monitoring switches to actually check the physical position of the contactor being opened or closed. I have seen similar things for either monitoring and alarm systems, or just if you wanted to logically couple a contactor state with a low voltage (e.g. 24 V) control circuit without adding a relay in parallel.
@cck14963 жыл бұрын
@@alexanderkupke920 Thanks for your kind reply.
@Viper6077063 жыл бұрын
I'm confused. When you showed the n24 and m24, it displayed nearly 26v, but you stated it had 24v, isnt electrical equipment sensitive to overvoltage?
@vikaskarthik95593 жыл бұрын
Sir, can you do a video on maintenance of high voltage alternator? And also its meggaring procedure
@leckyjake3 жыл бұрын
Will put that on the list. Thank you for the support
@meradsaad70162 жыл бұрын
Hi, thak you for this vedio, please could you explain just for the x40 and x41 I can't see theme on the wirring diagram. Thanks a lots
@umifaizah16553 жыл бұрын
Manuak booknya sangat lengkap .... Banyak kapal tidak ada manual book atau manual book tidak lengkap
@augosttweelve5370 Жыл бұрын
what a great talent u hv.
@tjairicciardi97473 жыл бұрын
great video, especially the good low volume of music in background.
@leckyjake3 жыл бұрын
Thanks
@gulfelectricaltrainingcent1993 жыл бұрын
Very good experience and knowledge sir ! Which country are you working
@frankcloskey77892 жыл бұрын
Excellent Trouble Shooting.6/20/22yr
@JC-me6nj2 жыл бұрын
Leckyjake lang sakalam. Lupet mo idol. Sana maging kasing galing din kita, I'm soon to join onboard na rin as assistant electrician. 🙏😇
@leckyjake2 жыл бұрын
good luck sa biyabe mo lods and journey mo. Dapat sa susunod ETO ka na
@jorgeargerich1091Ай бұрын
Very good my friend !!!
@osmankaya96643 жыл бұрын
Thank you for detailed information Sır!
@leckyjake3 жыл бұрын
Thank you for supporting the channel
@Hxa231jh3 жыл бұрын
Galing tlaga ni Sec.😁
@mohammedabdulrahman2390 Жыл бұрын
Great troubleshooting and fixing Many thx
@leeaudio0273 жыл бұрын
LOVe your videos and your knowledge, thanks for sharing!!!
@leckyjake3 жыл бұрын
Thank you for the support
@mohammedarifuddin32552 жыл бұрын
You have Great skills!
@-outsiders-69753 жыл бұрын
You always get to the every problems logically... 😍
@Marri-Tech3 жыл бұрын
I find relays being a common issue in industrial applications. Solid state relays seem to be allot more reliable
@whatevernamegoeshere36443 жыл бұрын
Sadly they also offer less isolation as they are not galvanically isolated when off so the number of possible applications are tighter
@alexanderkupke9203 жыл бұрын
@@whatevernamegoeshere3644 I assume with relays being mechanical devices and especially in marine or industrial environments that may have to deal with vibration dirt and corrosion (at sea everything will start corroding) you are right. Also relays able to switch a certain amount of current are readily available these days. For anything drawing higher currents a contactor would be used anyways. But I also can imagine that with "older" equipment switching everything over makes economically no sense.
@whatevernamegoeshere36443 жыл бұрын
@@alexanderkupke920 Corrosion and vibration might not be a factor at all. It really depends on the relay. There are ones that are completely molded into a solid brick of plastic. Another thing is that you would really not replace those relays with solid state relays. It's 24V DC, so a simple BJT would make a whole lot more sense
@akashshekhar286016 күн бұрын
Keeeeeepppppppp makingggggggg thesssseee type of videos
@ayeminpaing52032 жыл бұрын
Really thank you for your sharing videos.
@MdAtikMahbub2 жыл бұрын
The succeed moment is wonderful
@farhaanshaikh98503 жыл бұрын
Kudos frm one lecky to another good job bro😉
@leckyjake3 жыл бұрын
Safe sailing
@g.gzephyr8302 Жыл бұрын
Thank you so much sir i have learned so much ❤
@maverickboss20103 жыл бұрын
Lecky sir, salute to you for your magnificent job. I just request you to put some videos of boiler troubleshooting, coz I had problems in calibrating sipart as aux boiler was not firing and giving air servo error although dp transmitter was giving 4-20mA signal. Another common problem is boiler water level control is not operating in auto as feed water valve is defective, despite water controller giving 4-20mA signal,pilot burner toowas not firing due to defective cable. Plz suggest some easy ways of troubleshooting like this, thank u
@reemwill87632 ай бұрын
If that relay said it was on and had the proper voltage what made u change it and why was it the problem if it was working properly?
@aubreysimungala9671 Жыл бұрын
Interesting. And what about when the the elevator is going up and down without anyone to press the button
@andyatmosphere Жыл бұрын
How was the indicator light on MCA still on but not engaging the relay.?
@dwaynes59832 жыл бұрын
Great troubleshooting.
@dfox87133 жыл бұрын
Very smart Elec..
@leckyjake3 жыл бұрын
Thank you so much
@Mainly_Electrical3 жыл бұрын
Great knowledge!! More videos please , there really interesting
@DhammaSharingChannel242 жыл бұрын
main issues may be come from door operator or sensor, but sometimes single system reset can solve the issue like this in lifts
@kushalvolvoiker23843 жыл бұрын
Nice troubleshooting
@abenakupastilan68453 жыл бұрын
Galing talaga.
@leckyjake3 жыл бұрын
Salamat
@adityaputra67472 жыл бұрын
Im so happy too.. that u close the job
@anurathenuwara892 жыл бұрын
wonderful explanation thanks gy
@gokulkr64933 жыл бұрын
Love from India 🇮🇳❤️
@stephenellis91493 жыл бұрын
Great work as always. Fantastic trouble shooting. Keep up the great work and entertaining videos.
@leckyjake3 жыл бұрын
Thank you very much
@jonmaclennan62383 жыл бұрын
Great fault finding 👌
@leckyjake3 жыл бұрын
Thanks
@eyadalsaadi3 жыл бұрын
Am sure maybe its my misunderstands after interchange the VCB#3 on Genset #4 problem was cleared (NO REVERSE POWER TRIP ON VCB) , Cause of that logic action to open VCB#4 to find out the defective parts. Continues for my first comment on REVERSE POWER AT GENSET#4
@leckyjake3 жыл бұрын
That is correct. Hello Eyad, First of all thank you for watching my videos and really appreciate the time. After interchanging, no more nuisance reverse power trip happen and the Generator can be put on loas using the other VCB hence there is no problem on the curcuit side of the Generator that is why I focused in opening the VCB only.
@gabrielcarlo91963 жыл бұрын
Good job
@leckyjake3 жыл бұрын
Thanks
@corneliusmaring5452 жыл бұрын
Great video!
@seth29asigadi253 жыл бұрын
Sir may video kana po ba kung paanu ka nag simula sa pagiging E.T.O? REE/RME po ako sir balak ko po din mag barko baka may advice ka po hehe. Salamat sir. Keep safe!
@waynep3433 жыл бұрын
i wonder why the Elevator company did not include a relay test circuit board... to plug relays in.. and test their operation.. did you examine the contacts thru the clear plastic.
@leckyjake3 жыл бұрын
I did not check anymore the contacts as the coil is activated but still not activating the MC so I go straight in changing it to make the troubleshooting faster
@waynep3433 жыл бұрын
@@leckyjake i can understand that.. but i used to use relays like those. in a project.. i set up a rotary switch with piezo buzzer.. so i could close the relay by pushing a button.. with the other hand i rotate thru the contacts and i could hear changes in tone indicating the relay contacts were getting corroded so i could change it out before it totally failed. took me seconds per relay.. kept my project working with only a 10 or 15 minutes of scheduled down time a month to go thru the relay tests.. i did have banana jacks so i could take the piezo out of the circuit and hook in my ohm meter. its just sharing.. i worked on a friends 104' wooden power boat for 22 years.. my cousins are fishermen in the pacific northwest .. i went on their fishing boat while it was in harbor one day.. these guy go out in the gulf of alaska .. the poor workman ship and planning of their electric and hydraulic systems scared me . your going to take this out in 50 foot seas at -50F i went straight to their grand father and had him get involved in getting some of it corrected..
@gglovato3 жыл бұрын
wow i was not expecting so many control boards for a single lift(one electronic, 2 relay boards), ¿why so complicated?, plus all ancient DIP packages, looks like a 1990's controller, is the ship that old?
@engr.hasanmahmud Жыл бұрын
Hi @leckyjake, i faced same problems ... really it was very satisfying and relief moment. :D
@parammariner9 ай бұрын
Good video ....Thanks From C/E Maersk Cape Town
@kelmana99573 жыл бұрын
Good day sir, we have the same type of elevator, can you share your insight regarding f54 alarm? From my troubleshooting, my locking magnet (retiring cam) is not being energized. The power for LM relay should come from the SIO board. But some conditions I think is not satisfied. Hope you can somehow help me. Thanks and continue to inspire our fellow ETO/Elect.
@aswinp43533 жыл бұрын
Great job sir 🤩
@leckyjake3 жыл бұрын
Thank you
@arturorujano1693 жыл бұрын
hello leckyjake greetings Do you know any online site that you can recommend me to do the ME-C course?
@abdelrahman.hzidan21022 жыл бұрын
Thanks friend 🥰
@makinistangmandaragattv55603 жыл бұрын
Very informative sir..pa shout-out po
@liwinthomas41073 жыл бұрын
The moment sir✌
@leckyjake3 жыл бұрын
Thanks
@stevenmelgoza35803 жыл бұрын
How long have you been a electrician for?
@reymadz38743 жыл бұрын
Good day sir, how to identify visually if the MC is not working?
@leckyjake3 жыл бұрын
Hi Rey, I pressed any call button from the outside and once x40 and x41 activated, MCA and X29 the MC should also be activated. You will notice that visually once the coil is energized
@reymadz38743 жыл бұрын
@@leckyjake thank you sir Jake 🙏
@PracticalMECEngineStudy2 жыл бұрын
Similar Elevator onboard. After switching off and switching on Power, elevator is working fine. But after around a minute, when we call the elevator, the cage door closes only half and then opens. This keeps happening all the time. Then if we switch off the power and switch on, everything becomes normal. But after about a minute, same trouble again. Pls advise