Fan Coil Unit (FCU) Fundamentals and BMS sequence of Operation

  Рет қаралды 34,646

Engineering & Automation

Engineering & Automation

3 жыл бұрын

Fan Coil unit is a common equipment found in all residential and commercial buildings. And also forms an important part in cooling applications. In this video you will learn about the basics of FCU with its components and working principle along with the BMS sequence of Operation
For learning about the Building Management System or the Building automation system please follow the below link:
• BMS Building Managemen...
Building Management System Basics and History with Features
For learning about the Air Handling Unit (AHU) Fundamentals with Cooling Principle and its components please follow the below link:
• Air Handling Unit (AHU...
Air Handling Unit (AHU) Fundamentals with Cooling Principle and its components
For learning about the BMS Monitoring & Control of AHU Components and Sensors please follow the below link:
• BMS Monitoring & Contr...
BMS Monitoring & Control of AHU Components and Sensors
• Understanding the conc...
Understanding the concept of Control System - Basics, Open & Closed Loop, Feedback Control System.
• BACnet - Introduction ...
BACnet - Introduction to BACnet with Details of BACnet Communication Protocols, Objects & Services

Пікірлер: 38
@ashranulum1898
@ashranulum1898 11 ай бұрын
Dear Sir You taught about FCU in an outstanding way. Thank you so much for making the video.
@engineeringautomation
@engineeringautomation 11 ай бұрын
hi,, thanks a lot for your feedback. appreciate it. Kindly share and subscribe.
@sayyadafrid5101
@sayyadafrid5101 3 жыл бұрын
Thanks for posting. ♥️
@sayyadafrid5101
@sayyadafrid5101 3 жыл бұрын
The way you explain is extraordinary. And loved to watch your vedios. Please do keep posting vedios on building management system. Your vedios are best source for us to learn. Thanks for sharing your knowledge with us♥️
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Sayyad, thanks a lot for always supporting me.😊
@sankaras8311
@sankaras8311 Жыл бұрын
excellent video for simple and quick understanding, great job...
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi Sankar.. thanks a lot for your feedback.. please share and subscribe
@yathishkumar7391
@yathishkumar7391 3 жыл бұрын
👍👍
@sulakshanaravishan2892
@sulakshanaravishan2892 3 жыл бұрын
Thanks
@xavierthankaraj1381
@xavierthankaraj1381 2 жыл бұрын
Excellent Explanation thanks lot sir .
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Xavier.. thanks for your feedback. Please subscribe and support
@marinpiskov9038
@marinpiskov9038 Жыл бұрын
It's fantastic.
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi marin.. thanks a lot for your feedback. Please share and subscribe
@akhilsm6840
@akhilsm6840 3 жыл бұрын
Hiii Sir , super video series, completed all the video series so far u posted in the channel keep it up and expecting more. I have a query regarding this video, could you tell me when AHU is already supply fresh air and takes back the dirty air why fan coil unit is given. I hope the AHU supply air would be properly cooled, then why one more cooling unit is required.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Akhil, thanks a lot for your feedback and support. Please share and subscribe. In case of an AHU serving many areas and rooms, it is not possible to achieve certain temperature for a particular room. For example if there is an electrical room which require certain temperature with the AHU supply, it is not feasible to achieve proper cooling considering the heat dissipation from the electrical panels. Providing FCU helps to achieve proper cooling in that particular room. Also it is cost efficient as you dont have to do bigger ducting all over the building and that will increase the AHU load & size. Hope this helps.
@akhilsm6840
@akhilsm6840 3 жыл бұрын
@@engineeringautomation Well explained, thanks a lot. I request you to continue the series
@syedzameer2103
@syedzameer2103 11 ай бұрын
Pliz put video related bms is useful
@engineeringautomation
@engineeringautomation 8 ай бұрын
Hi… thanks a lot for your feedback.. please share and subscribe..
@syedmohiuddinsohail6460
@syedmohiuddinsohail6460 Жыл бұрын
Can you make a video on ERU, chilled water system & hot water system
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi Sohail.. Sure will do. Please share and subscribe to the channel.
@sumanthmkundar6101
@sumanthmkundar6101 3 жыл бұрын
Sir please upload fcu breakdown videos
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Sumath, please let me know what exactly you are looking for. Accordingly i can include it in my upcoming videos. Please support us by sharing and subscribing to our channel. Thank you
@joelgeorge8700
@joelgeorge8700 3 жыл бұрын
Hello sir please make a video on function block diagram.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi joel, thanks for your feedback. Will definitely include it in future videos. Please subscribe and click the notification bell.
@vinod8894
@vinod8894 Жыл бұрын
Please make chiller sequence video
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi Vino.. sure will do.. please subscribe to the channel.
@abdulasheeb5264
@abdulasheeb5264 2 жыл бұрын
Bro upload more videos plz
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Abdul.. i am working on next video.. got held up in a project commissioning and handover.. please click the bell icon for notification. Thank u
@vishalkashyap3193
@vishalkashyap3193 Жыл бұрын
Sir hall k hisaab se kaise pata chalega ki kitne paani thanda karna h for AHU
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi vishal.. please see my AHU sequence of operation video.. its clearly explained there. Thanks
@derrickdcruz5212
@derrickdcruz5212 2 жыл бұрын
Hi Sir , may i know the main difference between a FCU System and VAV System.
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Derrick.. FCU is like a cooling unit which will have cooling coil to cool the air. But VAV as thr name says its a variable air volume unit. It only varies the volume of air and does not cool the air. It take air from the AHU and regulates the airflow to provide cooling to the room. But FCU, take air from the room and cool it before sending to the space. Hope this clarifies your query. Let me know if you need any other information. Please support by sharing and subscribing. Thank you
@derrickdcruz5212
@derrickdcruz5212 2 жыл бұрын
Hi Sir, thanks for the reply. That means can I say the VAV System is a stand alone system in which chilled water supply from the chillers is not required, whereas the FCU cool the air from the cooling coil which is connected to the CHW pipes from the chillers.
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Yes.. u could say that. But VAV’s require AHU which cools the air since it only varies the air flow.
@derrickdcruz5212
@derrickdcruz5212 2 жыл бұрын
Hi sir thanks for the reply. I am new to facilities management. I am keen to know how are motorized valves for the AHU works together with the DDC .
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Derrick.. please watch my other videos which will help u to understand BMS. Flor valves control please see my video “kzbin.info/www/bejne/kKnQp6mQqt-rnqM”
@will_hunt
@will_hunt 9 ай бұрын
You said the valve opens and closes if room cooling is needed or not. So the valve is 100% open if cooling is needed and instantly 100% closed if it’s not. It’s never 50% open etc? Also, you said the fan keeps going 10 mins after it hits the set point. Do the valves shut off the second it hits the set point? If so, wouldn’t the fans just be blowing the same untreated air right back into the room? Why wait 10 mins to shut off the fans if they’re doing nothing in theory?
@engineeringautomation
@engineeringautomation 8 ай бұрын
Hi will.. if the valves are modulating type, then the amount of valve opening is decided by the PID controller.. see my video on PID controller.. the fan just recirculates the cold air in the space when the valve is closer. There are some cases the fan can be shut off completely. It depends on the region of use and power saving configurations. Hope this helps
Variable Air Volume (VAV) Unit's Fundamentals and BMS sequence of Operation
10:03
Engineering & Automation
Рет қаралды 16 М.
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 40 МЛН
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 125 МЛН
How Fan Coils Work in HVAC Systems
7:24
MEP Academy
Рет қаралды 35 М.
HVAC service call: Fan coil unit (FCU) No heat
9:00
Jumper man Tech
Рет қаралды 32 М.
Air Handling Unit (AHU) Fundamentals with Cooling Principle and its components
4:46
Engineering & Automation
Рет қаралды 187 М.
Basics of HVAC Controls - Components
18:21
Slipstream
Рет қаралды 28 М.
HVAC Systems : Understanding Components and Functionality | Mr. Smart Explains!
5:51
Working principle of Fan Coil Unit | HVAC 07
5:14
AMJ Engineering
Рет қаралды 164 М.
Tag him😳💕 #miniphone #iphone #samsung #smartphone #fy
0:11
Pockify™
Рет қаралды 4,2 МЛН
8 Товаров с Алиэкспресс, о которых ты мог и не знать!
49:47
РасПаковка ДваПаковка
Рет қаралды 177 М.
My iPhone 15 pro max 😱🫣😂
0:21
Nadir Show
Рет қаралды 1,7 МЛН
Это iPhone 16
0:52
Wylsacom
Рет қаралды 412 М.