No video

EO5 Stack Flue Sensor on a Pentair Mastertemp Heater - How to fix it

  Рет қаралды 70,127

askthepoolguy

askthepoolguy

Күн бұрын

Pentair Pool Quick Link for Parts/Equipment: amzn.to/3q6MXmf Mastertemp Pool Heater Parts: amzn.to/391FMio
Heaters are really important in Michigan here Mark talks about Error Code EO5 and how to go about fixing this heater, or how to problem solve.
For all the pool knowledge you're looking for, check out Ask the Pool Guy HQ. Here, you'll find everything you need to know about swimming pools, all in one place. Ask the Pool Guy is passionate about sharing the vast knowledge he has acquired throughout his decades in the pool industry, and he wants to make sure everyone has an enjoyable pool experience. If you can't find the information you're looking for here, you can contact him or a capable member of his team!
Visit our Ask the Pool Guy Website: www.askthepoolg...
Legendary Escapes is the home of the hybrid swimming pool. Al, the designer and builder, and his team are passionate about creating unique, one-of-a-kind pools. They are constantly innovating and coming up with new ways to better serve their clients. No two Legendary Escapes pools are alike, and they are unlike any pool you'll find elsewhere. Our website showcases our projects, as well as providing helpful information if you're a current pool owner or considering building a custom swimming pool in Michigan or a looking for a custom pool build anywhere in the United States.
To learn more about the construction arm of Ask the Pool Guy, check out the Legendary Escapes website: www.LegendaryEs...
Ask the Pool Guy and Legendary Escapes are striving to share the knowledge! We don't think homeowners in SE Michigan should be the only people who have the opportunity to enjoy a beautiful, one-of-a-kind, hybrid swimming pool; so we're working with builders across the country to bring hybrid pools to you. We're happy to work with local builders, wherever "local" might be, to design and build beautiful custom hybrid swimming pools all over the country.

Пікірлер: 27
@DordiHOTS
@DordiHOTS 6 жыл бұрын
Thank you so much. I was getting E05 shortly after the heater started heating (approx. 30 seconds). After I replaced the stack flue sensor, the issue went away. A couple of things to note to fix E05: a) the main circuit board located under the control board membrane should be cleaned, you can unscrew the 4 screws of the board and clean it. You have to disconnect the membrane connector on the left by pulling it CAREFULLY. b) the air blower needs to be cleaned thoroughly, there is an inlet and it should be cleaned of leaves and debris. c) the entire heater should be cleaned from debris and leaves. Especially on open contacts above the igniter near the gas which could cause a short circuit and an electrical explosion with gasoline. This is the most important thing to clean. d) the stack flue sensor should be replaced by a Pentair factory part (Pentair 77707-0010 Thermal Regulator). Make sure you buy a factory OEM part otherwise the connectors might not fit. Poolandspasupply has the OEM part. e) the Pentair 77707-0010 Thermal Regulator should also be checked as this can be related to E05 or E06, it is located outside the enclosure between the water inlet and outlet. You can use a flathead screwdriver to release the spring loaded regulator and investigate it for corrosion. f) all of the electrical connections should be checked for corrosion, and short circuits between contacts. Spiderwebs, dirt, leaves or debris can cause electrical hazards which is why a thorough cleaning and vacuuming is necessary. How to check if the Pentair Stack Flue Sensor 42002-0024S is bad: 1) Using a multimeter, set the device to resistance testing mode (The icon looks like a horseshoe). 2) Put each multimeter prong on the stack flue sensor terminals. If the resistance measures 0 it is bad, replace the stack flue sensor. 3.5 ohm or higher means the sensor is working.
@jonhays8124
@jonhays8124 5 жыл бұрын
Great video! This saved me at least a hundred dollars by not having to call someone out, THANKS! It would have been great to get an angle on the video looking into the heater to see the sensor, but it was still easy enough to find. I bought my sensor on amazon for 22 dollars and the replacement took about 10 minutes. Thank you very much
@Askthepoolguy
@Askthepoolguy 5 жыл бұрын
Great- glad it helped!
@kreader50
@kreader50 5 жыл бұрын
Awesome video I checked my Flue sensor after seeing your video. I checked the wires and they were okay. I pulled on the wires where they connect and pushed them back into the socket and it started working. My heater sits out in the weather and we had some serious rain the other day. I am wondering if some water got in to where the wires connect. Thanks for sharing
@pfactor5201
@pfactor5201 4 жыл бұрын
Thank you for a very informative video. Short and sweet, cut to the chase.... Thank you
@Askthepoolguy
@Askthepoolguy 4 жыл бұрын
You are welcome!
@tradermactrade7242
@tradermactrade7242 7 жыл бұрын
Hey Like your video's. My panel stopped working years ago but now my HEATER stopped firing and have no codes to read. so I replaced the STACK FLUE SENSOR the IGNITER AND NOW the IGNITION MODULE and still no firing of heater? NONE of the parts were bad so I'm baffled. NO ignition now and it ran perfect for 10 years. Any ideas?? I've hared about a ignition lockout but no idea where to find it.
@carlosfarias4008
@carlosfarias4008 5 жыл бұрын
Amigo tengo un problema con el pentair 250 error r13 me podría a a yudar
@richardmeszaros3421
@richardmeszaros3421 6 жыл бұрын
OK, I had code eo5, replaced stack flue sensor, and still have code eo5, board read out flashes 40 80....now what can I check?
@Askthepoolguy
@Askthepoolguy 5 жыл бұрын
If you don't have a pool guy available to ask- Pentair has several codes on their website to track through - and their customer support line is also handy...we will try to address this question in an upcoming video for future viewers as well!
@enriquedosterjr.3367
@enriquedosterjr.3367 5 жыл бұрын
Richard, I had the same problem. Were you able to fix it?
@psantini5963
@psantini5963 4 жыл бұрын
You can check sfs , with a meter . Reading should be around 3.5 mega ohms . If it reads good you have a bad control board . Remove the board and follow traces for the 2 white wires . The 4 th pin on my board to a spot on the board was open . Soldered a wire jumper in place of the open trace . Back in business . Saved 500 bucks vs pool repair tech
@ciceromuniz6020
@ciceromuniz6020 6 жыл бұрын
good evening! I'm Brazilian I have mastertemp to LPG gas. which is consuming a lot of gas. Can you help me?
@Askthepoolguy
@Askthepoolguy 5 жыл бұрын
Hello - if you are using a lot of gas you may want to try a solar cover, either a physical cover or the liquid solar blanket to prevent evaporation of your water when it warms up. Also - check your system to make sure you don't have a gas leak - and make sure your gas line is sized appropriately to your heater size. A mis match between the gas line input and the amount of gas the heater needs can cause an issue.
@OliverLeveritt
@OliverLeveritt 6 жыл бұрын
I was getting the E05 code, so I Googled it and came here. I went back out to the heater unit and wondered if the big ass grass (that stuff that grows 6 feet tall) was causing a problem. It was spread out to within about 6" of the exhaust. I got my trusty Ryobi One+ hedge trimmer and cut that stuff back about two feet. Problem solved.
@Askthepoolguy
@Askthepoolguy 5 жыл бұрын
Landscaping that grows up around the heater is a very common issue, and often overlooked by homeowners...glad you caught it!
@gmonyy1
@gmonyy1 7 жыл бұрын
So I replaced the sensor and it didn't solve the issue. What else could it be? The circuit board, maybe?
@DordiHOTS
@DordiHOTS 6 жыл бұрын
Check the fuel supply, thermal regulator, resistance of the stack flue sensor (should be 3.5 ohm or higher), obstructions in the exhaust flue or air blower, or shorts from cobwebs on the circuit board.
@wsohl
@wsohl 7 жыл бұрын
Probably should show video of where the sensor is.
@Askthepoolguy
@Askthepoolguy 7 жыл бұрын
Great idea - watch for this in a future video!
@douglasfritz7944
@douglasfritz7944 5 жыл бұрын
My heater will heat for about 10 minutes then shut off for a bit then back on and off. Any suggestions?
@douglasfritz7944
@douglasfritz7944 5 жыл бұрын
No error codes, or flashing lights under the control panel. Did notice wires going into heating chamber had insulation missing
@pvt-pilot
@pvt-pilot 5 жыл бұрын
If you have no error codes and no diagnostic lights illuminated on the back side of your contol board, then it sounds like a bad thermal regulator. I would suggest removing it and testing it and replacing it if necessary. Watch my video here if you need help with that: kzbin.info/www/bejne/aXa1nnh-nZ19Z9U The purpose of the thermal regulator is to open up at temps exceeding 120° which will let cold water into the output side of your heater manifold in order to dilute the superheated water heading to your spa. This is a justified safety designed to prevent scalding a user sitting by a jet and also prevent melting a hole in your underground plastic PVC plumbing heading to the pool from the heater. The contol board can detect this unsafe scenario due to the presence of the HLS (High Limit Switch) which is located on the bottom left side of your manifold (output side) Hope this helps.
@chengkhang2804
@chengkhang2804 4 жыл бұрын
whats the error code?
@tradermactrade7242
@tradermactrade7242 7 жыл бұрын
should have mentioned it's a mastertemp400
@torymblue2000
@torymblue2000 7 жыл бұрын
Actually this doesn't show much at all :) How to test, check resistance on the sensor (yours is obviously bad, but bet most don't have their wires torn off). What is a good resistance when brand new, maybe what the resistance is when it's at temp..
@DordiHOTS
@DordiHOTS 6 жыл бұрын
3.5 ohm is the proper resistance for the stack flue sensor on the Pentair MasterTemp models. Anything higher is also OK. When the sensor is bad, it will likely read 0L for the resistance.
How to Repair Pentair Master Temp Error E05 or E06
8:44
Craig Wooster
Рет қаралды 84 М.
How to fix a MasterTemp Pool Heater Stack Flue Sensor (SFS) Error
6:11
❌Разве такое возможно? #story
01:00
Кэри Найс
Рет қаралды 3,6 МЛН
ISSEI & yellow girl 💛
00:33
ISSEI / いっせい
Рет қаралды 25 МЛН
나랑 아빠가 아이스크림 먹을 때
00:15
진영민yeongmin
Рет қаралды 2,2 МЛН
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 3,6 МЛН
Pool/Spa Heater Repair- Error Code 05
5:09
Fix It With Jake
Рет қаралды 24 М.
Ask the Pool Guy: 10 Steps to Descaling A Pentair Pool Heater
2:45
askthepoolguy
Рет қаралды 32 М.
Pentair Mastertemp 250 heater not turning on?
3:44
askthepoolguy
Рет қаралды 11 М.
Fixing AGS error on a Pentair MasterTemp 400 Heater
1:35
Oceanside Pools
Рет қаралды 3,8 М.
MiniMax NT Pool Heater Error Code E05
11:26
Tom Jones
Рет қаралды 10 М.
Troubleshooting Pentair Mastertemp heaters
6:05
Zwickieland
Рет қаралды 60 М.
Pentair MasterTemp 400
10:18
Vegas Warrior
Рет қаралды 1,1 М.
❌Разве такое возможно? #story
01:00
Кэри Найс
Рет қаралды 3,6 МЛН