There is a mistake in calculation, for the no of bar in footing. The no of spaces came to be 6.84 nos. The no of bars= 2*(6.84+1) = 15.7~16 Nos. So, 16*23= 368 nos.
@AmitPrakashces5 жыл бұрын
how are you taking single overlap. The wall is considered to constructed between pillar. There is no wall that starts at one pillar and does not end at another pillar.
@janlevinson1604 Жыл бұрын
in my opinion, 5-0.65*2 is not correct because 5 is clear distance, not center to center distance.
@kishlayjha1561 Жыл бұрын
Yes true
@De_cuttingedge3 жыл бұрын
16:40 when u take the total length as 60 do we need to excavate entire 60m.sir can ask u something ,if the long walls are taken as 20m then the short wall won't be 10 m each.the 1.3 width will cover on each sides from the long wall length,isn't .Someone plz clarify my doubt
@pranavtagore3 жыл бұрын
Yes, the inside span for the excavation will be reduced, but the excavation will also extend after the 20-metre span equals half of 1.3m from the centre, which will account for it.
@preeshanupadhyay1467 жыл бұрын
how is it that after the deduction at 16:40 l=3.7? can anyone clarify?
@aswinivv47414 жыл бұрын
Footing size taken is 900mm instead of 800mm. Taking 100mm for Pcc.
@ParthVaity-yi4wn4 ай бұрын
Can anyone pls tell me how the Number came to be 21 and 2 in Double and single overlay in the bw?
@qqwzxcv4 ай бұрын
Please tell if you got the answer
@goteakshay084 жыл бұрын
Nice sirrrr
@shaileshmayekar24956 жыл бұрын
Hello sir please suggest a good book to do quantity estimating based on construction blueprints
@lb19234 жыл бұрын
Yes sir please
@AkashDubey946 жыл бұрын
why P.C.C is required....sir asked the question,why we can't start brick after ground....please clarify ...
@dhruvzalawadia30996 жыл бұрын
1) pcc is use for leveling. 2) you can't use any construction material because when it comes in contact of ground there will be a chance of corrosion of steel.
@shimish5 жыл бұрын
Sir at 16:40, how deduction is 3.7 m????
@santoshg33905 жыл бұрын
To construct the footings we need to excavate on eithe side of the pillar center line... which keeps the pillar in center of the footing.. so.. at the gate way which is 5mtr in width.. the footings on it left and right side will extend up to 0.65Mts from its centre.. as the gate way has two footings on both sides.. total deduction will be..5-(2*0.65)=3.7.. I hope ur doubt is clarified
@arialcad4 жыл бұрын
5 m is the clear distance. iI is not center to center distance. Therefore 250 mm + 50 mm + 200 mm = 500 mm should be deducted from both ends. 250 mm is half of 500 mm and 500 mm is the difference between the dimension of footing 800 mm and the dimension of the column along the wall which is 300 mm. 50 mm is the extra width needed for the PCC bed and 200 mm is clearance for the working space. Thus in the calculation of deduction 5000 mm - 2 * 500 mm = 4000 mm (4 m) length should be used.
@preeshanupadhyay1467 жыл бұрын
how is the number of pillars 23 can someone clarify 17:42
@ankitchauhan32077 жыл бұрын
when the boundaries are closed (think of a circle) no of pillars/nodes = no of segments divided = 60/2.5=24 but when boundaries are open no of pillars = no of segments +1=(60-5)/2.5 +1=23 it is similar to the seating arrangement problem of circular table and row
@moriwahfelix73095 жыл бұрын
Pls sir how can I get the lecture 1-5 of the video to download
@ankitchauhan32077 жыл бұрын
structural steel =152.59 kg?
@ParthVaity-yi4wn5 ай бұрын
How? Mine came 153 kg. Here is what I did 1) total ht of ISA=0.55m 2) Total no of pillars= 23 3) Total wt of ISA=12.1 kg/m Therefore, total wt= 0.55x23x12.1 = 153.06kg
@fakhrysami3 жыл бұрын
Thanks clear
@karamveersinghtomar48745 жыл бұрын
How to calculate brickwork
@rameshatla86685 жыл бұрын
sir i want to more videos sir plz send
@Sprkoppal4 жыл бұрын
👍
@fakhrysami3 жыл бұрын
Thanks
@shaikirshad28725 жыл бұрын
remove subtitles pls because its not comfortable to understand ..