How to Wire a Solar Disconnect for a DIY Camper Electrical System

  Рет қаралды 171,322

EXPLORIST life Mobile Marine & Off-Grid Electrical

EXPLORIST life Mobile Marine & Off-Grid Electrical

3 жыл бұрын

In this blog post, I am going to teach you how to wire a solar array disconnect, why you need one, and which one to use when installing a solar array into your camper electrical system. THIS VIDEO HAS BEEN UPDATED HERE: • SOLAR ISOLATOR WIRING ...
A solar disconnect is not only convenient but is also a code requirement. By the end of this blog post, you will know what disconnect to use, why you need to use one, and how to size the disconnect.
Links mentioned in this video:
➤ Blog Post & Parts List: www.explorist.life/how-to-wir...
➤ How to Crimp Wire Ferrules: • How to Crimp Ferrules ...
➤ How/When to Fuse a Solar Array: • How to Fuse a Solar Pa...
➤Need additional & personalized help? Consider joining my private group: www.community.explorist.life
Here are some additional resources that you may find helpful with planning and installing your DIY Camper:
➤DIY Camper Solar Wiring Diagrams: www.explorist.life/solarwirin...
➤How to Perform a Power Audit: • How Much Solar Power D...
➤Basic Parts & Components of an Electrical System: • Basic Solar Parts Need...
➤How to Cut Wire: www.explorist.life/how-to-cut...
➤How to Strip Wire: • How to Strip Wire from...
➤How to Crimp Wire: • How To Crimp Wire Lugs...
➤How to Make MC4 Connectors: • How To Make MC4 Connec...
➤How to Wire Solar Panels in Series-Parallel: • How to Wire Solar Pane...
➤How to Crimp Wire Ferrules: • How to Crimp Ferrules ...
➤How to Wire an AC/DC Breaker/Fuse Box: www.explorist.life/how-to-wir...

Пікірлер: 423
@edwardconover4728
@edwardconover4728 2 жыл бұрын
Just came to your channel. This stuff is golden! What an education. I love that you are covering things is such a step by step manner and that you are giving the reasons for the safety regs. Thank you.
@stephenllewellyn4135
@stephenllewellyn4135 2 жыл бұрын
Seen quite a few of your video’s, and you put so much detail into a easy to understand presentation, and such a big help as I slowly build my camper electric’s,you do a awesome job thanks steve 👌
@FreeSpiritOz
@FreeSpiritOz Жыл бұрын
I have found your videos just in time. Im installing solar on my yacht, just as on your camper /RV. Your videos are very educational. I now can proceed with my installation. Dont worry I have an electrician friend helping me..
@OCNJKirk
@OCNJKirk 3 жыл бұрын
Wow! Glad I saw this. I am building to your diagram from before you added this to your designs. THANK YOU for your diligence with code requiements!!!!!!!!
@csteutterman
@csteutterman 3 жыл бұрын
Very timely! I actually just asked a question on one of your wiring diagram blog posts (although I couldn't get the question to actually post) a couple days ago wondering why the ampacity rating was so high on the breaker. Now I have my answer. Good stuff.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Haha, I saw that and didn't respond because I knew this video was coming out within a few days. Glad you found it! (I'll probably still answer, but with a link to this video when I sit down and answer blog post comments.)
@k33ganat0r9
@k33ganat0r9 3 жыл бұрын
Just started my journey on the campervan trail and I know nothing about electricity and wiring and all this and I apparently said something that surprised my grandpa that is an old naval electrical engineer so I must be learning something. Thanks for the great vids can't wait to learn more. Doing a box truck conversion on an old 1974 dodge 3/4 ton, my very first conversion project! So exciting
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@jamescabaniss5857
@jamescabaniss5857 Жыл бұрын
Excellent video. Things are covered that I have asked about and never really got good answers although most you think you know why (it is good to have someone backup your theories, lol). Some of my thoughts/questions that he answered: why you cannot use the 48 volt DC switches, why you cannot use an AC switch on DC, why you should use 2 wires instead of the usual 1 on a DC switch, etc.
@wendybyrne1301
@wendybyrne1301 3 жыл бұрын
Perfect timing! My dual pole disconnect arrived last week and I will be installing it this coming week... This helps a lot! Thank you!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@bveryafraidsc
@bveryafraidsc 5 ай бұрын
Did this get wired backwards on the MPPT side? I bought the same one from link and the symbol/diagram next to identifier show + and - reversing top to bottom.
@bhunter736
@bhunter736 Жыл бұрын
Thank you for pointing out and explaining the NEC code for this. I'm thinking my combiner box already meets this, but since those are outside I'm going to install a box similar to what you demonstrated with right next to my inverter for convenience. I'm also going to put a label regarding the NEC code on it as a reminder. Your videos are all so clear and purposeful, thank you.
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Glad it was helpful!
@iamcleverdic
@iamcleverdic 2 жыл бұрын
Thank you. Helped me understand the primary purpose of the circuit breaker: Switch off power from the panels.
@englishstone340
@englishstone340 10 ай бұрын
You explain things perfectly and your speed of talking/explaining is outstanding! I will owe you for a big thanks when I finish my solar project!
@EXPLORISTlife
@EXPLORISTlife 10 ай бұрын
Awesome! Glad it helped. Thanks for watching!
@rikmorel4870
@rikmorel4870 2 жыл бұрын
Awesome video. I'm building an RV and was just at the stage of adding the solar disconnect. Learned a LOT with this and saved me a lot of hassle down the road, and possibly a disaster as well as I was about to use one of the switches you advised to never use here.
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Glad it was helpful. Cheers!
@SVInsouciance
@SVInsouciance 3 ай бұрын
Thank you. Purchased a new SSC and 32A breaker for our boat and subsequently realized that the breaker wiring could be “omni directional”. Now I’m good to go. Nicely done video.
@SA-sb7rt
@SA-sb7rt 3 жыл бұрын
Thanks for being clear , because it’s confusing. Better to be simple in this subject 👍👍
@matthewewert8751
@matthewewert8751 2 жыл бұрын
Hello Nate, Thanks for making all of these videos! The information is extremely helpful! Just wondering if you were ever considered making some videos for a setup much less complicated and on a smaller scale. Like an over-landing vehicle (Jeep) with a dual battery setup under the hood and 200W solar just to power a small propane heater and fridge? Something small enough that wouldn't require an inverter maybe? Thanks again and love the videos!
@SocalMarineUSA
@SocalMarineUSA Жыл бұрын
legend bro - setting up solar at my shop cos I dont have a fixed building for city power - your vids are superbly helpful!
@MrA1582000
@MrA1582000 3 жыл бұрын
You are such an excellent teacher. So step by step logical instructions.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@EminenceFrontX5
@EminenceFrontX5 2 жыл бұрын
Thank goodness this channel exists! Thank you!!!!
@randombanana358
@randombanana358 3 жыл бұрын
awesome video. Extremely helpful! I have a 90v 40a array and this really help me
@mikeanderson6219
@mikeanderson6219 Жыл бұрын
Leaned a lot from all your videos. Thanks. One tip I learned though (looks like you may have also, but omitted it in the video), once you cut and have run the wires into the box, remove the breaker for easier access to install the wires in the breaker. Then, you can push the wires back out and reinstall the breaker. 👍
@garywoodworth2979
@garywoodworth2979 2 жыл бұрын
Great information. Very direct. Good job. Thank you.
@laylyly12
@laylyly12 2 жыл бұрын
Thank you , very good demonstration.
@carykern6079
@carykern6079 8 ай бұрын
Excellent, I almost purchased 30 amp breakers. Thanks!
@mallorymcguire833
@mallorymcguire833 2 жыл бұрын
I love your channel.Ican go back and watch these videos multiple times if I need to, along with all the other ones.
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@dwighthapeman6590
@dwighthapeman6590 3 жыл бұрын
Another awesome, clear, helpful and right on the money video. Thank you. YOU ARE THE MAN!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Glad it was helpful. Cheers!
@naughtysquirrelontheroad1542
@naughtysquirrelontheroad1542 3 жыл бұрын
Brilliant detail and really well explained! Thanks!!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@parmorama
@parmorama 2 жыл бұрын
Thanks Nate, your brilliant 👍
@amudlifecrisis
@amudlifecrisis 3 жыл бұрын
Nate, I've been watching your videos for a while now. Your video production and associated blogs are of the highest quality and so professional, very impressive. Thanks so much for all the information you share. You have a great teaching style that seems to come so naturally to you. I don't personally build van's or campers but have used your helpful tutorials to build a solar shed and an off grid system for my Ham radio shack/office. 73 de W1SMM
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Nice! Sounds like an awesome project! Thanks for watching!
@joshhaas2410
@joshhaas2410 3 жыл бұрын
This is a sweet video as always. Nice clean install too. For my trailer, however, my 2x panels in series will plug into an SAE input jack on the outside of the rig so assume I am ok just pulling the panel cable connection from there.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Maybe? Code doesn't say anything about that, but that would indeed disconnect both conductors at the same time.
@pedrorodriguez7601
@pedrorodriguez7601 3 жыл бұрын
Thanks for what you do👍
@larryschwartz9010
@larryschwartz9010 2 жыл бұрын
Hi Nate, very helpful video as usual. Most other video simply recommend one of the other breakers that you suggested not be used due to voltage issues which I appreciate. One question I had was where do you get that black backer board for install? I dont see it on your parts list. Thanks
@cowboyyoga
@cowboyyoga Жыл бұрын
Thanks Teacher!!!! All your videos are super helpful! I am learning slowly but surely! )))
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@Mgroce9635
@Mgroce9635 2 жыл бұрын
Very helpful, I installed this in my new system
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@dancronin6436
@dancronin6436 3 жыл бұрын
Very helpful! Thank you!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Hey Dan Cronin, No problem! Glad it helped! :)
@david.st1
@david.st1 2 жыл бұрын
Professional done videos. Good Job!
@TheCornucopiaProject-bd5jk
@TheCornucopiaProject-bd5jk 8 ай бұрын
I like that cable duct, very flexible for wire entry
@pcaffeldt
@pcaffeldt 3 жыл бұрын
Thanks so much for your solar videos
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Hey Paul Affeldt, No problem! Glad it helped! :)
@ARepublicIfYouCanKeepIt
@ARepublicIfYouCanKeepIt 3 жыл бұрын
LOL, that DC-DC charger just wasn't going to let you connect it instead of the MPPT charge controller! Love it. While the NEC doesn't _technically_ apply to off-grid RV installations, they are, nonetheless best practices. As such, I follow code as much as possible and practical. This is to say that not everyone does (follow code, that is). I just finished up redoing what what supposed to have been a completed off-grid solar system in a 1969 Airstream renovation. The original work was performed by an electrical engineer. When I got involved, there was one 100V/50A MPPT charge controller for the permanent roof-mount array *and* an auxiliary portable array! A 1-1+2-2 battery switch, rated for 32V max, was installed to connect/disconnect arrays. The 3S 100W panels produced ~65V nominal @ ~6A. This was all connected with 4AWG wire! What a mess. To correct this, I installed a second, smaller MPPT SCC for the portable PV array. I eliminated the battery selector switch, and installed a non-polarized, dual pole, DC breaker in an enclosure. I did the same between the roof-mount PV array and the first MPPT SCC. I also transitioned the wire down from 4AWG to 10AWG. Not only is the 10AWG more than adequate for the current, but the silicone insulation made cable management so much easier. A 30A shore power input was also previously installed...with zero protection between it and a MultiPlus worth well over $2K! I installed a non-polarized, dual pole, AC breaker on this line, as well, as one can never be certain what's coming off the post in many campgrounds. Unbeknownst to me, my client then took the trailer to the largest solar dealer in Atlanta. He paid them $500 to check my work. They assured him that everything was correct. However, they also told him that it was "overkill." What! All I can say is, "Buyer beware." Someone also told my client that the PV array must be grounded to the trailer chassis. Nothing could be further from correct. One should only ever consider grounding the frames of the PV array. Never the conductors! That's what the PV isolation breaker highlighted in this video is for! As always, Nate, great work!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Haha! Yeah... totally did the Orion DC DC on purpose. Okay, maybe not, rofl! I didn't notice until I was doing my final viewing after editing , exporting, and uploading but before the video went public. I'm surprised it took 2000+ views before somebody noticed; so, good job paying attention!
@ARepublicIfYouCanKeepIt
@ARepublicIfYouCanKeepIt 3 жыл бұрын
@@EXPLORISTlife Star pupils!
@alexmarchant1825
@alexmarchant1825 2 жыл бұрын
Brilliant explanation!
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Thank you!👍
@scotthermance2335
@scotthermance2335 Жыл бұрын
Thanks I like the code references. Cheers
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Thanks for watching :)
@pelecho
@pelecho 3 жыл бұрын
I have a 400w solar in series and a 40amp mppt. Do I have to used a dual breaker 50 amp or a 63amp ? Thanks and really good videos 👍
@snoutybear3849
@snoutybear3849 2 жыл бұрын
So if I wanted the breaker to act in the same way as a fuse would I choose a breaker slightly bigger than the short circuit amperage of my single panel. If that makes sense. Excellent video by the way.
@shafmahar4974
@shafmahar4974 3 жыл бұрын
You are the man
@Idahoprepper71
@Idahoprepper71 3 жыл бұрын
I understand you need the breaker for a home system that is connected to the grid, ( I have a grid tie system) but I have not heard of having to follow code on a camper or off grid cabin. I put one in on the system that I installed on my toy hauler, but it was just for my own safety so I can disconnect it when I want to work on it
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Ultimately, nobody is going to be checking our work on a camper. There are no inspectors for this. My goal is to teach the safest way I possibly can for this stuff and if people want to opt-out of particular things that they feel not important.. that's their prerogative.
@Tom111060
@Tom111060 3 жыл бұрын
... great tips as always ... and in 0.75-speed an old german guy can follow along as well ... ;-)
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@dan32one44
@dan32one44 Жыл бұрын
Good stuff thanks 🙏
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Thanks! 🙂🙌
@thehotmonkies
@thehotmonkies 3 жыл бұрын
Outstanding.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Hey Haut Monkay, No problem! Glad it helped! :)
@alexalley7591
@alexalley7591 2 жыл бұрын
Hi Nate Loving your videos - thanks. I have a question about wiring the switch up. I saw a video saying that you have the have the pos and neg on certain sides otherwise the unit bursts in to flames when turned off? Obviously + to + and - to -, but does it matter which side of the unit is used? mine has a large N on one of the terminals on the right hand side so guess that would be the neg connection, but does it really matter if i run the positive down the right hand side of the switch or the left hand side of the switch?? Hope that makes sense? many thanks
@bestillandknowthatuaregod
@bestillandknowthatuaregod 2 жыл бұрын
GREAT INFO..... COULD YOU USE THE SAME BREAKER FOR disconnecting th batteries bank from midnite classic charge controller ?
@knowledgeshortvideos
@knowledgeshortvideos 2 жыл бұрын
Hi. According to your explanation: 63amps dc breaker >250v fits all solar systems between pv and solar inverter. What about the amp size of dc circuit breaker between the inverter and the batteries? And the ac circuit breaker between in and out ac current?
@jamescullis
@jamescullis 3 жыл бұрын
Hi Nate, will Anderson plugs comply with the standard?
@larssmith3915
@larssmith3915 3 жыл бұрын
Hi Nate. Thanks again for taking the time to put these together. We really appreciate it. Quick question, are you using the glands just because they came with the box? It doesn't seem like it needs to be waterproof 😊 and two cables in one gland wouldn't do that anyways, right? Are you worried about the edge of the entry hole abrading the cable? A simple grommet would work for that, no?
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
More for wire strain relief to help hold the wires in the breaker in the event it gets loose.
@larssmith3915
@larssmith3915 3 жыл бұрын
Gotcha. Thanks for the reply
@magnusengelmark
@magnusengelmark 3 жыл бұрын
Nate, great video. I have question I've been trying to figure out the answer for. I have 100 W panel installed on my campervan's roof and now I want a flexible addon system so I've bought a foldable 120 W panel that I'm pulling out every now and then to increase the solar power charging. I want it wired to the same Victron Smart Solar 75/15, all good there.. but! I want a flexible way of connecting and disconnecting the foldable panel. I'm thinking a socket and a plug but also a switch, either for both panels or only for the foldable one so I can flip the switch to disconnect, plug in the foldable panel, then flip the switch again to connect the panel to the Victron Smart Solar. Is that a viable and for the equipment safe way of handling my desired use case ? I realise now that you say that the voltage maximum is an issue for my idea.. If I use a disconnect maybe I'll mess it up by maybe flipping it on and off every day for a couple of times a day for a couple of weeks straight, they're not designed for that use as I've heard. Best regards Magnus from Sweden.
@jimkemp1816
@jimkemp1816 2 жыл бұрын
I built out my electrical system according to the custom design you created for me and it works fantastic. I'm finally adding a 120W suitcase solar panel and the plan doesn't show a DC disconnect switch. Do I need one if I only plan to occasionally connect the panel to the MPPT charge controller? The disconnect would be the MC4 connectors between panel and charger controller.
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
I'd say it's fine without for portable panels. You can 'turn the panels off' by flipping them over face-down and then when you disconnect both MC4 connectors; that is effectively disconnecting both the positive and negative conductors.
@mosesmotaung3884
@mosesmotaung3884 3 жыл бұрын
Hi Nate, your videos are super good. I am learning a every time I watch your videos. Keep up the good work
@gregridge9273
@gregridge9273 3 жыл бұрын
This video is a great piece of information! I'll use it in my system. BTW, what app or program do you use for those terrific (and clear) diagrams?
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Hey Greg! Glad it was helpful. I use Microsoft Visio for all of my diagrams.
@scottcarlson5424
@scottcarlson5424 2 жыл бұрын
I’ve ordered my disconnect and will be installing in the near future. Thanks so much for all your videos! I do have a question…when the disconnect is switched off, and the PV panels are active, ie generating voltage, is there any heat build-up to be concerned with?
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Nope. 👍
@georgekabele640
@georgekabele640 2 жыл бұрын
Hi, I will be installing 8 Hanes Q. duo L- G8.3, 425w solar panels and I am confused what kind of PV array disconnect with DCbreakers. Thanks for your help.
@adysandeddie
@adysandeddie 3 жыл бұрын
As always great video! a quick question - ive been wiring the breakers you just showed NOT to wire , as thats the one youve been wiring before in the past. ( 50amp marine grade breaker. ) Is this a fire hazard in all my previously installed vans ?
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
I mean, I can't say that it will for sure start a fire, but pushing more voltage than rated is indeed a hazard. To what degree, I don't have a metric for.
@charlesriggs6406
@charlesriggs6406 2 жыл бұрын
EXCELLENT!!!!
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Thanks! 👍👍
@thomasbuechner9053
@thomasbuechner9053 3 жыл бұрын
Really great video. I would like to know what the Backer Board is that was used to screwing everything down to. I have looked at backer board for tiling but it is pretty brittle. I could use a piece of plywood but would like to find something a bit smoother. A sheet of ABS plastic would be nice but pretty expensive.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
What did I use? or what should YOU use? lol For the sake of this video... that is the bottom (rubber) side of a $5 floor mat/rug that is screwed to a piece of plywood; which I would NOT recommend for a permanent install. BUT... in my next full install, I'll be using plywood with coin grip flooring covering the surfaces with the components screwed to that.
@BenjaminMedlock
@BenjaminMedlock 3 жыл бұрын
Quick question. Would this solar disconnect work with 5.4 amp setup? I am starting off small, but I want to do things right. I have 100 watts of solar and one battery.
@markmackillop8742
@markmackillop8742 10 ай бұрын
I purchased two of these breakers from your link a while back. My plan was to use the second one in the same enclosure as a shut off for my Orion dc to dc charger. I was hoping that the 63 amp rating would offer redundant over current protection for my 6 awg cable coming from the van bus bar under the drivers seat. Is this an ok application for the breaker?
@markmackillop8742
@markmackillop8742 Жыл бұрын
I purchased this breaker box and 63 amp breaker from the product list on from your video. I see that the box fits two breakers. Is there a reason that I should not use a second identical breaker for the shut off and protection for my Orion dc to dc charger? 8 Awg for panel 6 Awg for Orion are the cable sizes I’m using. Thank you for all you do
@scottleggejr
@scottleggejr 3 жыл бұрын
My problem is my heat gun needs a hell of a big solar array to run 😂 Great channel and video!
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
lol, true. I usually use a heat gun when I'm testing a system and purposefully trying to drain the batteries a bit. I think I'm going to get one of the Dewalt cordless heat guns soon for general usage: amzn.to/3faSaBl
@dennisspino2607
@dennisspino2607 2 жыл бұрын
I have a combiner box outside by the panels in a weather proof box with 3 - 15amp breakers will this be ok and not have to be in the house.
@LA-Creative
@LA-Creative Жыл бұрын
Hi, this is such a great video! I’m wanting to make a quick PV disconnect inline switch for a tiny, camping DIY solar generator / power box using a 12v Renogy 10A solar controller, connect to a 12 watt .5A solar panel and a 7Ah NPP SLA battery. It’s purpose it so power small devices for a tent. There are situations where it would be helpful to shut down the solar panel current coming to the controller while working on the battery or removing the battery. The controller instructions however say not unplug the panel before the battery so I’m guessing a regular inline SAE switch cable is not advised? If so, do you have any smaller current 12v switches you can recommend? Are any of the ones you pointed to in this video (that do not work for larger, gov regulated systems) good for my set up? Thanks so much!
@SamCarleton
@SamCarleton 11 ай бұрын
I have one question…. I have my tiny little teardrop camper wired up exactly the way you described! I’m about to rewire things, make a cleaner, tighter install. I’ve seen others install the solar disconnect without putting it into the waterproof box that you used. In my install I really don’t have very much space. Can I get away without using the water proof box?
@nielpapenfus4321
@nielpapenfus4321 2 жыл бұрын
One question, you said it is a regulation to have a solar breaker, so why does Jayco and multiple more caravan builders don’t install it? All that it is on the incoming positive wire is a 30a fuse.
@dagwood1327
@dagwood1327 3 жыл бұрын
Very helpful. Now you know.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Awesome! Glad it helped. Thanks for watching!
@dagwood1327
@dagwood1327 3 жыл бұрын
@@EXPLORISTlife I’m planning on / hope to do an off grid whole house and shop in the next couple of years. I really like the setups you do. Victron and battle born.
@dagwood1327
@dagwood1327 3 жыл бұрын
I have done several of my own house and shop wiring. I want to do solar while the government still allows it.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Sounds like a cool project! 👍👍
@engineeringVirtue
@engineeringVirtue 3 жыл бұрын
Is there a breaker panel that takes and sends out three pairs of md4 connectors for multiple panel groups connecting to the new Victron smart solar 150/85 or bigger controllers...I'd rather use dedicated cables for each group and not seeing why I don't stick with the BogueRV prepared cables... new to all things solar though.
@briananddianehardy8598
@briananddianehardy8598 3 ай бұрын
Hi Nate, this is a great video like so many of yours. We live in Australia and I have a question, our caravan has a 1000 watts of solar on the roof and is connected to a Victron 250/70 mmpt solar controller. Our system hasn’t been installed with a solar disconnect, what size would you suggest. Regards Brian
@scottpiper4228
@scottpiper4228 3 ай бұрын
Question. Can I use 10 awg PV wire for other power uses inside the RV, as I've a lot of it left over. Thanks for any help.
@tariqusman2250
@tariqusman2250 3 жыл бұрын
Our inverter has 2 mppt input each can take 11A . but our PV Panel produces 17.33A. Can we use Y connector to divide current and input 8.665A per mppt input?
@chasing_tail_rv
@chasing_tail_rv 2 жыл бұрын
Do you have a video where you do this with multiple charge controllers? NOT the video of wiring multiple charge controllers to the Victron Lynx Distributer, but to this point. Or do you just use 2 entry glands and 2 of these disconnects?
@skippylearn
@skippylearn 2 жыл бұрын
Thanks for this. I was able to do this following your link for parts and watching your video. And I have to say it works!!! But I have a question!? This disconnects power from the solar array. So that you can work safely on your unit. But isn't there still power of the battery?? Thats a safety concern as well?? I dont know anything abt electric still learning tks. I guess when you shut of power, w the disconnect it should be followed with disconnecting the battery as well.? For total safety
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
All of my systems at www.explorist.life/solarwiringdiagrams do indeed have a switch at the battery that would need to be turned off before anything else.
@williebechmeister3190
@williebechmeister3190 2 жыл бұрын
I have a solar generator in my house that will be hooked to three 400 watt solar panels wired in series. Together the three panels will generate 150 volts DC at 9 amps. It looks like the breakers you are using will work with this setup. Are there any similar breakers that can be used outside. I would prefer to mount the breakers at the panels on my solar ground mount rather than inside the house.
@stevedecoded1
@stevedecoded1 2 жыл бұрын
Very informative video, grateful your channel exists. Conscious of the space for electrics in my van (but of course safety comes first) - if I take two of those 48V max square breakers (one for the pos wire and one for the neg wire coming from one 24V PV) and position them side by side, would this have the same effect as a dim rail breaker and box? Thanks
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
Nope. The positive and negative conductors need to be able to disconnect simultaneously.
@stevedecoded1
@stevedecoded1 2 жыл бұрын
Ah I just noticed that although there are two pairs of wires to be fed into the breaker there is only one switch to flip that turns both off. Very helpful, thank you
@dans1516
@dans1516 2 жыл бұрын
Great vid as usual. and I already bought the box and breaker, but...should you, or can you also have an inline fuse/breaker on a single 400 watt solar panel?
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
You need a disconnect, but no fuse. More info: kzbin.info/www/bejne/qWKzZGSerdF3aas
@jeffboyd241
@jeffboyd241 2 жыл бұрын
Hi Nate, i ordered the breaker you recommended in your link, but the wireing diagram on the front of it says black red on top and red black on the bottom, in the video you wired the breaker black red on top and black red on the bottom..can you please tell me the correct wiring for the breaker you recommended in your link
@sandramac3
@sandramac3 11 ай бұрын
Hi there. I wired this same breaker between my panels and controller. Are they ever defective? I now show volts coming in but no amps. All readings were good before I added the same breaker. Yes panel wires come in the top, and bottom wires go to controller….same polarity.
@srupp9271
@srupp9271 2 жыл бұрын
Excellent ! One thing I don't understand and I know there is always a reason for why things are made the way they are. Why do the incoming wires positive and negative need to be disconnected simultaneously ?
@EXPLORISTlife
@EXPLORISTlife 2 жыл бұрын
In short: if the positive and negative wires upstream of the switch rub together and create a direct short, the negative wire could be carrying voltage even if the positive wire was disconnected. I'll let you google the long answer. It's in some white papers out there somewhere but I'll let you chase that rabbit on your own.
@MillyRose539
@MillyRose539 2 жыл бұрын
Does the disconnect in a combiner box pretty much do the same thing?
@5chips
@5chips 3 жыл бұрын
Hi Nate, I am a new subscriber and have been watching many of your videos. I am inquiring if I could use 2 of the resettable fuse inline circuit breakers as a disconnect, one on the positive and the other on the negative, if my two 160 watt panels are connected in parallel with an open circuit voltage of 22.9V and a Optimum operating voltage of 20.2V? Thank you.
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
I recommend using the breaker that I showed in this video.
@billshepard5917
@billshepard5917 3 ай бұрын
I'm about to add solar disconnect breakers to my travel trailer, I have roof mounted panels as well as a thru wall plug for portable. I know I will add the disconnect between panels and controller for the roof mounted, but I also want to add one for the portable circuit. My portable has the controller attached to the array. Do I need to move that controller to between the battery and the disconnect or is it OK to leave the controller where it is (panel>controller>thru wall plug>disconnect>battery) I was thinking in this configuration the thru wall plug become an alternate 12V source with the disconnect to turn it off.
@ZerHour
@ZerHour 2 жыл бұрын
Have you seen the double pole DC breakers were the wire polarity at the top is opposite at the bottom of the breaker they have + & - marked on each end and are aligned opposite ?
@noxikid
@noxikid Жыл бұрын
be carefull with them, they can catch fire when trips off even under normal current if they were wired with wrong polarity
@benhalliburton5304
@benhalliburton5304 Жыл бұрын
Excellent info you have provided! Would it be possible to combine the breaker shutoff feature and also be able to satisfy the fuse requirements on that side of the controller? Say one needed a 30amp fuse on the positive side between the controller and panels, couldn't the shutoff breaker be rated at 30amp, allowing the breaker to do a dual duty? An older video but perhaps someone out there has a thought on this...thx
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Nope. The fusing would need to be on the 'panel' side of the combiner.
@BobHancy
@BobHancy 3 жыл бұрын
Would I ever need to disconnect my solar panels from the controller in case of an emergency? If so, how would I do that? Use a battery disconnect switch? Or...maybe I wouldn't ever have to worry about that?
@doyodanne
@doyodanne Жыл бұрын
Awsome video as usual! Is it really a good idea to put two cables through a wire glands?
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
If you don't need the gland to be waterproof an are just using them for strain relief, it's totally fine.
@baqarrizvi8740
@baqarrizvi8740 7 ай бұрын
Dear, my pv array current is 415 volt , is there any available breaker or protection that can trip in case of short circuit or over current or amp
@kenname-private5355
@kenname-private5355 3 жыл бұрын
Nate: Thank You for excellent videos and information. I'm just starting to install solar on our travel trailer. Can you provide information on the H-5 disconnect box you used? Is it available on Amazon?
@EXPLORISTlife
@EXPLORISTlife 3 жыл бұрын
Glad it helped! Info on the breaker box can be found in the parts list from the blog post: www.explorist.life/how-to-wire-a-solar-disconnect-for-a-diy-camper-electrical-system/
@themeditationsociety5334
@themeditationsociety5334 2 жыл бұрын
Thanks for all the great info, what should we do in the case of a small cabin installation, do we still need the breaker? What does it mean solidly grounded?
@chesterbreder5368
@chesterbreder5368 10 ай бұрын
How does the NEC effect vehicle systems? Except maybe good practices.
@Dave_Simmons
@Dave_Simmons Жыл бұрын
Just a little FYI, the DIN rail circuit breaker box you link to is currently unavailable. However, other sellers are selling the same box. Your videos are a great help to me. I'm working on putting together a 24V system, I don't know what the final size will be yet. I'm buying a few parts for it each month, as my finances are rather limited.
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
I've switched my recommendation away from this breaker and box largely because nobody on Amazon could keep them in stock. We now stock an actual DC isolation switch in our store. Check the pinned comment.
@Dave_Simmons
@Dave_Simmons Жыл бұрын
@@EXPLORISTlife Thanks, I'll do that.
@WilfredoHernandez-lz9pk
@WilfredoHernandez-lz9pk Жыл бұрын
Hey how are you doing? First of all, I like to see how you explain all your videos . I'm starting been interesting in solar panel systems & I built one in my house as a fun time. Now, I bought a solar controller similar to a Panda one or something like that; & I have noticed that wattages/amps are fluctuating too much. My system is built with: 4 panels of 100ah 12v in series/parallel making 24v system, solar controller 60amps, inverter 3500w, now I'm using 4awg wires for batteries, 10awg solar controller/panels, 8awg controller/batteries, also, & maybe this is the reason of fluctuating 4 car batteries. Could you give some tips about why wattages/amps are fluctuating too much.? thanks in advance.
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Hey, Wilfredo Hernandez! I appreciate you taking the time to ask your question, but unfortunately, I don't have enough info about your specific question to provide an accurate answer, but here is a playlist that, if you watch all of the videos start-to-finish (and take notes 😉), you'll have a REALLY good idea of how to design a solar array which may help with your troubleshooting: kzbin.info/www/bejne/gJzFpGtqqKd7qck
@JamesPartlow-lx6wx
@JamesPartlow-lx6wx Жыл бұрын
Nate Jim Partlow here. I purchased the DC solar disconnect switch for my solar install . I also see that you have used a solar disconnect breaker and din rail. Which is best or are both needed? In all your wiring diagrams you use one or the other, is it just a change in product and serves the same purpose. Thanks
@LarryRichelli
@LarryRichelli 5 ай бұрын
I need a solar panel A/B switch. In other to send solar to two different inverters/chargers. Any ideas.
@neilrankin9945
@neilrankin9945 2 ай бұрын
Thanks for the video! I’m wondering, hypothetically if a charge controller with an on/off switch would accomplish the same objective as a breaker?thank you
@EXPLORISTlife
@EXPLORISTlife 2 ай бұрын
I don’t really like dealing in hypotheticals. I’m more of an action-based-solutions kind of guy.
@JD-ft2lr
@JD-ft2lr 2 жыл бұрын
From the video (I only watched once) it seems the breaker is just a two pole switch in all practical purposes. Why not just use a two pole Anderson type plug?
@murziktuzik9571
@murziktuzik9571 5 ай бұрын
Nate, I didn't find that the disconnector is UL listed. My permit says that all equipment must be UL listed. I cannot find a mini disconnector that UL listed. Question - can I use the Anderson connector that rated higher than my PV system and UL listed?
@dominic-ryan
@dominic-ryan Жыл бұрын
Makes perfect sense, thanks! Question about the reset breakers you show at 5:37 though, the middle breaker shown is (I believe) an audio line breaker? I've been told these are totally unsuitable for use as a breaker for any constant DC power load. Is this correct? If so, what makes them unsuitable?
@EXPLORISTlife
@EXPLORISTlife Жыл бұрын
Yeah, I don't recommend those in any electrical system because there isn't a reputable manufacturer that makes that type of breaker (maybe there is a good reason for that?). Blue Sea, Cooper, Eaton, Bussman, Littelfuse are a few of the overcurrent protection manufacturers I'm looking at when purchasing and recommending overcurrent protection.
@dominic-ryan
@dominic-ryan Жыл бұрын
Thanks @@EXPLORISTlife , that was close as I was about to put a bunch of these breakers (bimetallic I think they are called?) in my van. Concerning as I deliberately sought them out as they are the type used by the auto electrician who originally put my inverter in. Anyway, think I'll perhaps look at just an ANL fuse for the battery and either the Bussman or Blue Sea 187 series breaker for my inverter and perhaps just a basic blade fuse box for everything else (nothing above 40A).
How to Wire a Solar Charge Controller in a DIY Camper Electrical System
10:07
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 250 М.
DIY CAMPER ELECTRICAL MISTAKES (and how to avoid them)
15:40
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 119 М.
Как быстро замутить ЭлектроСамокат
00:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 14 МЛН
Пробую самое сладкое вещество во Вселенной
00:41
Кушать Хочу
Рет қаралды 4,4 МЛН
ИРИНА КАЙРАТОВНА - АЙДАХАР (БЕКА) [MV]
02:51
ГОСТ ENTERTAINMENT
Рет қаралды 1,9 МЛН
Купили айфон для собачки #shorts #iribaby
00:31
How to Wire Different Sizes of Camper Solar Panels Together - Effects of Mismatched Solar Panels
12:19
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 347 М.
Perhaps the weakest link in the US electrical system
25:48
Technology Connections
Рет қаралды 3,8 МЛН
Storing Solar Power on my ROOF!!!
17:08
Quint BUILDs
Рет қаралды 4,5 МЛН
How to Fuse a Solar Panel Array for a DIY Camper Electrical System
7:24
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 191 М.
DC Isolator - Wiring a Solar PV Disconnect Switch
13:18
Signature Solar
Рет қаралды 7 М.
DIFFERENT TYPES OF DC FUSES (for a DIY Camper Electrical system)
10:03
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 30 М.
What Is A Black Start Of The Power Grid?
17:06
Practical Engineering
Рет қаралды 2,1 МЛН
RV Solar 101 : Everything a Beginner Needs to Know !
22:41
DIY Outdoor Life
Рет қаралды 303 М.
How To Build A Solar Setup: COMPLETE Step-by-Step, DIY Guide (12V, 2000W)
31:59
DIY Sprinter Camper Van Electrical Install - Full Tutorial
1:13:01
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 1,2 МЛН
Привезли САМУЮ ГРЯЗНУЮ BMW НА МОЙКУ #shorts
0:23
РЕЖУ ВСЕ
Рет қаралды 1,6 МЛН
CHOOSE CAR FOR MOM🥰#best #subscribe #viral #like #foryou
0:17