Extractive Distillation of Ethanol and Benzene using p-Xylene in DWSIM

  Рет қаралды 14,595

eduX

eduX

Күн бұрын

Пікірлер: 29
@majedaljaber134
@majedaljaber134 2 жыл бұрын
I appreciate your spent effort in making such fabulous videos! Keep on, please! Wish you all the best academically and professionally!
@eduXinsight
@eduXinsight 2 жыл бұрын
Thank you so much for the appreciation.
@jay39157
@jay39157 2 жыл бұрын
I am very much impressed by the way speedily you perform simulation.We are learning many things from you. Keep up good work continue Thanks
@nidhisharma6967
@nidhisharma6967 2 жыл бұрын
Thanks a lot for this video sir. Really very helpful. Want to learn more and more from here, keep up the good work. Thanks a lot again😇
@user-wk9sp7nk2j
@user-wk9sp7nk2j 10 ай бұрын
Thanks for your hard work! I have a problem. My list of CAPE-OPEN Unit Operation is empty. how to add? thank you in advance!
@thisisbismay5681
@thisisbismay5681 3 жыл бұрын
Very informative
@AroojFatima-zz2yr
@AroojFatima-zz2yr 3 жыл бұрын
You are genius 💪
@-_HansMartuaPardede
@-_HansMartuaPardede 2 жыл бұрын
Sir, I Drag Cape-Open Unit operation and I click OK but there is something happend, the flash unit of column distilation is nothing, so what is solution for this Problem?
@juancq8689
@juancq8689 3 жыл бұрын
I have a question: In the flash distillation unit, is correct that the ethanol is in the top of the column(consider that the boiling point of Benzene is 78 C and Ethanol is 80 C) ?
@eduXinsight
@eduXinsight 3 жыл бұрын
Hi Juan, Thanks for your interesting question. Yes, it is true in a binary mixture of ethanol and benzene that ethanol should be the bottom product. But the addition of p-xylene as a heavy entrainer to enhance the relative volatility of ethanol over benzene. Hence, ethanol is separated from the distillate of the first extractive distillation column while the bottom stream containing benzene and p-xylene is sent to an entrainer recovery column to obtain benzene from the top of the column. For details please read the following article: pubs.acs.org/doi/abs/10.1021/acs.iecr.9b03095 I hope your doubt is cleared.
@ImperatoreTeo
@ImperatoreTeo 2 жыл бұрын
I have some questions: 1) which are the difference between complex coloum and azeotropic distillation? min 11:00 2) why you set total liquid reboiler on the second coloum? It shouldn't partial liquid? 3) My ethanol stream has only 72% of ethanol while you have 96%?
@chisomchuba9672
@chisomchuba9672 3 жыл бұрын
I followed all your instructions except the specifications in each column, I specified top and bottom mole fraction instead but got an error.
@eduXinsight
@eduXinsight 3 жыл бұрын
Can you share with me the error details?
@srivathsa1848
@srivathsa1848 3 жыл бұрын
Can you please do a simulation video on pressure swing distillation.
@salisusani23
@salisusani23 Жыл бұрын
QUESTION! Hello Muhammad, Thank You for this educative videos. I TRIES THIS EXAMPLE BUT I KEEP GETTING NaN error in the Solvent Stream connected to the Mixer. Please help.
@affanbhaijaan65
@affanbhaijaan65 2 жыл бұрын
Sir what should we do if we don't have number of trays and reflux data given in the question
@eduXinsight
@eduXinsight 2 жыл бұрын
First do shortcut distillation to find out the approximate number of plates and reflux.
@asmaabdelhamied9012
@asmaabdelhamied9012 2 ай бұрын
How add cape-open to dwsim
@danielnm6767
@danielnm6767 2 жыл бұрын
Good day Sir, I've followed all the steps you did in the video, but when it comes to the ChemSep column, I am not able to see the thermodynamics window, and as a result, my simulation gives me an error. Do you know how can I be able to activate such window?
@eduXinsight
@eduXinsight 2 жыл бұрын
well, I am not sure about it. because I did this simulation in the previous version of DWSIM. I will suggest you upgrade to the latest version of DWSIM and then see whether it solve the problem or not?
@danielnm6767
@danielnm6767 2 жыл бұрын
Unfortunately I've updated the software since the 6.4 version and the problem remains the same. Thanks for the reply.
@albertoaguilar9773
@albertoaguilar9773 2 жыл бұрын
I'm having exactly the same issue, the thermodynamics window won't appear, only reactions.
@bharatiyainnovator3185
@bharatiyainnovator3185 2 ай бұрын
I also have the same issue
@bharatiyainnovator3185
@bharatiyainnovator3185 2 ай бұрын
​@@albertoaguilar9773hey did you get the solution to it ?
@danear2
@danear2 3 жыл бұрын
Hello my friend and thanks for the video How can I contact you..?
@abhinavgupta1136
@abhinavgupta1136 3 жыл бұрын
I can't get that research paper can you please send me the pdf file or link to download the paper.
@abhinavgupta1136
@abhinavgupta1136 3 жыл бұрын
Please reply I am working on this project. So I need that research paper.
@rider-bi7lv
@rider-bi7lv 3 жыл бұрын
How can i contact you i need help in a project
Reactive Distillation Column Simulation in DWSIM
36:11
eduX
Рет қаралды 10 М.
95% Hydrogen Peroxide - Vacuum Distillation!
7:49
The Canadian Chemist
Рет қаралды 16 М.
Фейковый воришка 😂
00:51
КАРЕНА МАКАРЕНА
Рет қаралды 6 МЛН
The FASTEST way to PASS SNACKS! #shorts #mingweirocks
00:36
mingweirocks
Рет қаралды 15 МЛН
The CUTEST flower girl on YouTube (2019-2024)
00:10
Hungry FAM
Рет қаралды 45 МЛН
How to create Petroleum Assay in DWSIM
11:27
eduX
Рет қаралды 4,6 М.
Top 10 Software Used by Chemical Engineers
9:25
Chemical Engineering Guy
Рет қаралды 38 М.
The Problem with Biofuels
15:01
Real Engineering
Рет қаралды 1,9 МЛН
Refinery Crude Oil Distillation Process Complete Full HD
17:04
ChemicalEngineering
Рет қаралды 1,2 МЛН
Introduction to DWSim Chemical Process Simulation Software
12:43
Engineer TeeTee - Chemical Engineer
Рет қаралды 8 М.
Фейковый воришка 😂
00:51
КАРЕНА МАКАРЕНА
Рет қаралды 6 МЛН