Fan Coil Unit (FCU) Fundamentals and BMS sequence of Operation

  Рет қаралды 39,183

Engineering & Automation

Engineering & Automation

Күн бұрын

Пікірлер: 38
@ashranulum1898
@ashranulum1898 Жыл бұрын
Dear Sir You taught about FCU in an outstanding way. Thank you so much for making the video.
@engineeringautomation
@engineeringautomation Жыл бұрын
hi,, thanks a lot for your feedback. appreciate it. Kindly share and subscribe.
@sayyadafrid5101
@sayyadafrid5101 3 жыл бұрын
The way you explain is extraordinary. And loved to watch your vedios. Please do keep posting vedios on building management system. Your vedios are best source for us to learn. Thanks for sharing your knowledge with us♥️
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Sayyad, thanks a lot for always supporting me.😊
@sankaras8311
@sankaras8311 Жыл бұрын
excellent video for simple and quick understanding, great job...
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi Sankar.. thanks a lot for your feedback.. please share and subscribe
@sayyadafrid5101
@sayyadafrid5101 3 жыл бұрын
Thanks for posting. ♥️
@xavierthankaraj1381
@xavierthankaraj1381 3 жыл бұрын
Excellent Explanation thanks lot sir .
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Xavier.. thanks for your feedback. Please subscribe and support
@marinpiskov9038
@marinpiskov9038 Жыл бұрын
It's fantastic.
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi marin.. thanks a lot for your feedback. Please share and subscribe
@akhilsm6840
@akhilsm6840 3 жыл бұрын
Hiii Sir , super video series, completed all the video series so far u posted in the channel keep it up and expecting more. I have a query regarding this video, could you tell me when AHU is already supply fresh air and takes back the dirty air why fan coil unit is given. I hope the AHU supply air would be properly cooled, then why one more cooling unit is required.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Akhil, thanks a lot for your feedback and support. Please share and subscribe. In case of an AHU serving many areas and rooms, it is not possible to achieve certain temperature for a particular room. For example if there is an electrical room which require certain temperature with the AHU supply, it is not feasible to achieve proper cooling considering the heat dissipation from the electrical panels. Providing FCU helps to achieve proper cooling in that particular room. Also it is cost efficient as you dont have to do bigger ducting all over the building and that will increase the AHU load & size. Hope this helps.
@akhilsm6840
@akhilsm6840 3 жыл бұрын
@@engineeringautomation Well explained, thanks a lot. I request you to continue the series
@sulakshanaravishan2892
@sulakshanaravishan2892 3 жыл бұрын
Thanks
@vishalkashyap3193
@vishalkashyap3193 Жыл бұрын
Sir hall k hisaab se kaise pata chalega ki kitne paani thanda karna h for AHU
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi vishal.. please see my AHU sequence of operation video.. its clearly explained there. Thanks
@syedmohiuddinsohail6460
@syedmohiuddinsohail6460 2 жыл бұрын
Can you make a video on ERU, chilled water system & hot water system
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Sohail.. Sure will do. Please share and subscribe to the channel.
@derrickdcruz5212
@derrickdcruz5212 3 жыл бұрын
Hi Sir , may i know the main difference between a FCU System and VAV System.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Derrick.. FCU is like a cooling unit which will have cooling coil to cool the air. But VAV as thr name says its a variable air volume unit. It only varies the volume of air and does not cool the air. It take air from the AHU and regulates the airflow to provide cooling to the room. But FCU, take air from the room and cool it before sending to the space. Hope this clarifies your query. Let me know if you need any other information. Please support by sharing and subscribing. Thank you
@derrickdcruz5212
@derrickdcruz5212 3 жыл бұрын
Hi Sir, thanks for the reply. That means can I say the VAV System is a stand alone system in which chilled water supply from the chillers is not required, whereas the FCU cool the air from the cooling coil which is connected to the CHW pipes from the chillers.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Yes.. u could say that. But VAV’s require AHU which cools the air since it only varies the air flow.
@derrickdcruz5212
@derrickdcruz5212 3 жыл бұрын
Hi sir thanks for the reply. I am new to facilities management. I am keen to know how are motorized valves for the AHU works together with the DDC .
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Derrick.. please watch my other videos which will help u to understand BMS. Flor valves control please see my video “kzbin.info/www/bejne/kKnQp6mQqt-rnqM”
@syedzameer2103
@syedzameer2103 Жыл бұрын
Pliz put video related bms is useful
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi… thanks a lot for your feedback.. please share and subscribe..
@joelgeorge8700
@joelgeorge8700 3 жыл бұрын
Hello sir please make a video on function block diagram.
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi joel, thanks for your feedback. Will definitely include it in future videos. Please subscribe and click the notification bell.
@sumanthmkundar6101
@sumanthmkundar6101 3 жыл бұрын
Sir please upload fcu breakdown videos
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Sumath, please let me know what exactly you are looking for. Accordingly i can include it in my upcoming videos. Please support us by sharing and subscribing to our channel. Thank you
@vinod8894
@vinod8894 2 жыл бұрын
Please make chiller sequence video
@engineeringautomation
@engineeringautomation 2 жыл бұрын
Hi Vino.. sure will do.. please subscribe to the channel.
@yathishkumar7391
@yathishkumar7391 3 жыл бұрын
👍👍
@will_hunt
@will_hunt Жыл бұрын
You said the valve opens and closes if room cooling is needed or not. So the valve is 100% open if cooling is needed and instantly 100% closed if it’s not. It’s never 50% open etc? Also, you said the fan keeps going 10 mins after it hits the set point. Do the valves shut off the second it hits the set point? If so, wouldn’t the fans just be blowing the same untreated air right back into the room? Why wait 10 mins to shut off the fans if they’re doing nothing in theory?
@engineeringautomation
@engineeringautomation Жыл бұрын
Hi will.. if the valves are modulating type, then the amount of valve opening is decided by the PID controller.. see my video on PID controller.. the fan just recirculates the cold air in the space when the valve is closer. There are some cases the fan can be shut off completely. It depends on the region of use and power saving configurations. Hope this helps
@abdulasheeb5264
@abdulasheeb5264 3 жыл бұрын
Bro upload more videos plz
@engineeringautomation
@engineeringautomation 3 жыл бұрын
Hi Abdul.. i am working on next video.. got held up in a project commissioning and handover.. please click the bell icon for notification. Thank u
Fan Coil Unit  - FCU HVAC
13:19
The Engineering Mindset
Рет қаралды 741 М.
OCCUPIED #shortssprintbrasil
0:37
Natan por Aí
Рет қаралды 131 МЛН
БАБУШКА ШАРИТ #shorts
0:16
Паша Осадчий
Рет қаралды 4,1 МЛН
ВЛОГ ДИАНА В ТУРЦИИ
1:31:22
Lady Diana VLOG
Рет қаралды 1,2 МЛН
-5+3은 뭔가요? 📚 #shorts
0:19
5 분 Tricks
Рет қаралды 13 МЛН
BMS Monitoring & Control of AHU Components and Sensors
7:35
Engineering & Automation
Рет қаралды 95 М.
Variable Air Volume (VAV) Unit's Fundamentals and BMS sequence of Operation
10:03
Engineering & Automation
Рет қаралды 22 М.
How Fan Coils Work in HVAC Systems
7:24
MEP Academy
Рет қаралды 45 М.
Product New Fancoil Duct AHR Expo 17  NA ver
3:26
Samsung Latin / Aire Acondicionado
Рет қаралды 66 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 680 М.
HVAC service call: Fan coil unit (FCU) No heat
9:00
Jumper man Tech
Рет қаралды 33 М.
OCCUPIED #shortssprintbrasil
0:37
Natan por Aí
Рет қаралды 131 МЛН