OL is actualy open loop, thanks for the advice, i should be more well equiped for tommorow now
@aaronag78764 жыл бұрын
Great and very helpful. Based on the info in this video I have saved nearly £40 on parts and up to £100 engineer time. My oven was tripping the very sensitive consumer board and after testing the earth connection, I found my element was faulty and Ive ordered a new elemental unit. Thanks
@daveplumber68865 жыл бұрын
Informative video although annoying meter screen glare as commented. Slight ohms law error. Higher resistance on last element will result in lower current and hence LOWER power. i.e. Less wattage as you then stated. Agree with other comments on using insulation tester, but multimeter will often give a good first indication of an earth fault if you don't have an insulation tester. I didn't know what OL meant either but I know now thanks to a couple of useful comments!
@gingerpimpNo14 жыл бұрын
FYI: O.L means open loop, not over load
@mikejames6632 жыл бұрын
Excellent info mate, thank you, have you got to disconnect the existing element to test it.
@mokimoki39964 жыл бұрын
Good explanation on the element and earth tripping the RCD / ELCB
@Simon-ow4pg9 жыл бұрын
Very clear and to the point. Thank you very helpful. Quick question, what model of Fluke multimeter was that and would you recommend it?
@rocketman2464 жыл бұрын
Would an element where there’s no OL between the terminal and earth trip the RCD?
@sajidkhanmahmood3 жыл бұрын
after removing my cooker element i dropped the spade connector wires down the back so had to remove the back of oven to retrieve them but now i dont know which way round they go. my cooker is a zanussi and the element ony has 2 terminals and i thing the main screwing in bracket acts as teh earth. can the spade terninals be put on either way round please.
@mickcredland27317 жыл бұрын
I'd strongly suggest using an insulation tester. Measuring the resistance between live/neutral and earth using a multimeter will not give an accurate test result. If you stressed that element with an insulation resistance test at 500 volts you'd find that the reading you saw at 18Mohm probably drop below the 2 Mohm minimum required for safety.
@ricardinobp6 жыл бұрын
OL = Open Line Nice video with lots of examples.
@Russell-rc6qq2 жыл бұрын
Some say OL = open loop or open label. So is it "open line", "open loop", "open label", or "overload"?
@jeoffer10 жыл бұрын
Very good and helpful. One criticism is the multimeter screen is unreadable due to the glare from the lights.
@hawasamo70743 жыл бұрын
thought OL meant open line. Not over load
@avpinstarter3 жыл бұрын
if you dont have a auto ranging multi meter what range of ohms should you use Thanks
@hiramkhackenback3 жыл бұрын
Mega ohms scale
@petedrums4 жыл бұрын
Thank you for this, Very helpful. Just saved me a few quid!
@vinnychoff5 жыл бұрын
Good video which covers many points. thanks
@RcNerd7 жыл бұрын
I've replaced my fan. no heat. so replaced my element replaced still no heat or light. so I'm thinking thermostat on the dial.
@markhorgan36157 жыл бұрын
Good clear explanation thanks.
@tomcassidy68855 жыл бұрын
i hear you call ol over load if your going to teach any thing its called open line on a multi meter
@Russell-rc6qq2 жыл бұрын
Kindly note that your use of "your" should be "you're" as in "you are".