Great video Andy. My steam unit is making a knocking sound and has excessive water flow from the steam outlet, particularly at startup. Would you have any idea what could cause this?
@slonato20042 жыл бұрын
Hay sir, a would like advise. My steam generator works for about 10- 15 min. then whole things turns off. Main fuse on generator cuts of power. After that it is turning off every min or two. Is it overhated or something else? Thank you for your answer.
@nasirnadeem967911 ай бұрын
My streamer just one contactor on and off frequently but two other contactor not working he is on when i power on and after 2 sec it's cut off
@coolzone97136 жыл бұрын
Hello Mr. Andy, I have a problem in Tylo steamer . It works & generate steam but only for short time & then stop for while & again it works for 1 minute & this process comes again & again. so please let me know in which part exactly the problem is...
@aslamvahora26383 жыл бұрын
Thanks Andy, Do I need to change only the metal tip sensor or the whole cable as this will make a very complicated matter! Can I have the part number if poss pls?
@GoldenCoast3 жыл бұрын
It comes as one part so you will have to change it all. Contact your local Tylo dealer for details.
@jojoprieto7400 Жыл бұрын
Hi Mr Andy my tylo steam generator circuit card led green light not blinking
@GoldenCoast Жыл бұрын
Hello. This could be a number of things, as this looks like there is no power to the card. You will need a qualified engineer to; Check the mains supply. Check the red button cut out is ok (pressed in) Check the main switch is not burnt out. Trace the power to the card by working backwards from it. Please be aware that this MUST only be carried out by a qualified electrician or Tylo engineer. All the best, Andy
@tariqueanwer57232 жыл бұрын
How can we remove element?
@Pushilo4 жыл бұрын
Hello. I have Tylo Pure 8 and sauna does not get hot enough. How i can disable overheating protection?
@GoldenCoast4 жыл бұрын
I would strongly advise you DO NOT disable the overheat protection but contact your local Tylo supplier and discuss the problem with them
@aslamvahora26383 жыл бұрын
Hi Andy, My H1 control panels is showing high temperature wen not in use, so because of that the steam does not get on? Pls help
@GoldenCoast3 жыл бұрын
Hi Aslam, the most likely cause of this is the temperature sensor has failed and will need changing. Hope it all works out for you. All the best, Andy
@krimoL2S4 жыл бұрын
Hello Andy are still here. I havé mistake With my tylo steamer. Please help me
@GoldenCoast4 жыл бұрын
Hi. Could you let me know what your problem is?
@krimoL2S4 жыл бұрын
Thé tylo doesnt product steam. Water Goes outside
@nmx42263 жыл бұрын
Sir water solindte value continue water supply what I doo
@chaudharyghulamdastgir32846 жыл бұрын
Sir some time oc show on controller??
@GoldenCoast6 жыл бұрын
Hi there. To be able to answer that question, I'd need to know what controller you are using. Andy.