Does the tank refill after draining, or stays empty until turned on again to be used again?
@keechvlogs9002 ай бұрын
Hello Andy, recently Imported a Steam Generator Tylo Brand to India forget to get the display, again ordered but its reaching late, is there a way ON the machine without the display ( Like can we switch on the machine manually)
@mwengeimutinda11814 жыл бұрын
my steam generator is coming on sometimes it completely fails to come on. now its not coming on and its producing clicking sound at one of the relays. what could be the problem
@GoldenCoast4 жыл бұрын
Hi, it's quite likely there is a problem with the incoming voltage but I would advise you get a professional electrician to check this for you.
@PropaPalko4 жыл бұрын
Hi Andy, are you able to check if our steam generator is Genuine Tylo? Its supposedly a 12kw Tylo generator but Im not certain it is as its panels look different from yours in this video. Can we send you images to help confirm?
@GoldenCoast4 жыл бұрын
Hi Paul, there have been some changes to the Tylo generators over the years but if you want to send some pic over to andrew.james@goldenc.com I will be happy to take a look for you. Andy
@PropaPalko4 жыл бұрын
@@GoldenCoast thanks Andy will do so today
@johnalexander19374 жыл бұрын
How do I descale the generator
@GoldenCoast3 жыл бұрын
Hi John I've not made a video on this as its covered in the manual you would have received when your Tylo heater was installed. You can also find information on the process on the on descaler packaging. All the best, Andy
@saunasbuildersb295 жыл бұрын
Anyone can help me.. how to make the connection for control panel if we use two steamer for one control system... I don't remember how to connect and how it operated by that combination..
@sergio862078 жыл бұрын
hello! my Tylo Steam Generator don´t pass 27ºc is 9kw. what i can do? thanks
@GoldenCoast7 жыл бұрын
Best to get your local electrician round to check all of the elements are working ok
@asifknan10004 жыл бұрын
VA STEAM GENERATOR PROBLEM IS solenoid valve on not happening please the quotation on answer
@GoldenCoast4 жыл бұрын
Hi, If you have continuous flow of water through steam generator, follow points below. It could be that the solenoid valve is stuck open with dirt. Clean filter if fitted and clean valve. Check if voltage switches on/off to the solenoid. This is 230 volts. Or it could be that the PCB temp limit sensor has failed. The way to prove this is to unplug the little 2 black wired white connector from the PCB Then power up unit and check if water has stopped. I hope this helps
@gunasegar22747 жыл бұрын
tylo steam thermo activator 12mm 230vac
@molalegnbedada55143 жыл бұрын
My steam take along to give steam
@Carlos-b4p4k8 ай бұрын
Has anyone ever told you, you remind them of Sir Michael Caine?
@shabishan81958 жыл бұрын
zamin Ali
@rameshkc42952 жыл бұрын
Hi Andy, My steam generator is same like your video, I have some.problems , I will send you some videos with details in your Gmail.. will you help me to solve plz 🙏 Thankyou
@GoldenCoast2 жыл бұрын
Hi Ramesh, you can email at swimmer@goldenc.com please put 'KZbin question' as the subject line. Thanks