Faulty what condenser fan motor or relay???

  Рет қаралды 3,931

Michigan Heating Guy

Michigan Heating Guy

4 жыл бұрын

Is it a bad condenser fan motor or a bad relay. We are going find out www.amazon.com/shop/miheatingguy
Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
amzn.to/3pe2hYH
Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
amzn.to/3n5offb
Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
amzn.to/2JdAcku
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm
#MIHeatingGuy

Пікірлер: 18
@brandoncoffee8044
@brandoncoffee8044 3 жыл бұрын
Just a thought... could you just block off the top of the non working condenser fan motor? At least with one working it could still pull air through the condenser and not through the opening of the bad motor. Just to get them some cooling until the motor is replaced. As long as you head pressure didn’t get to high of course. Keep the videos coming. Glad to see your back!!
@ThermalDynamicSevices
@ThermalDynamicSevices 4 жыл бұрын
I take the black wire and put it on the load side of the contactor if I question a relay or fan lol
@donnierobertson3088
@donnierobertson3088 4 жыл бұрын
Nice job and video
@notanewbie1718
@notanewbie1718 4 жыл бұрын
You go to a lot of trouble carrying that camera around to your jobs. It is appreciated.
@andygalindo8978
@andygalindo8978 4 жыл бұрын
Bad condenser motors hold a charge with the capacitor. Since fan blade don’t turn it won’t let some charge escape. I may be wrong.
@RyanAnderson-jj7xj
@RyanAnderson-jj7xj 14 сағат бұрын
Switch fan leads, quick and easy, If it still doesn't run. Done and gone.
@RJMaker
@RJMaker 4 жыл бұрын
I bet you got capacitor bit. :-) I have learned the hard way to shunt any caps with a working voltage 460v and above.
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
yep, just takes a bad motor winding open or loose wire and contactor to open/chatter at just the right portion of AC sine wave to leave a cap charged to line voltage or higher from motor running/back emf on relay/disconnect open, then you grab and ZAP. Also it will be "DC" high voltage charge with enough current to kill you instantly, so BEWARE a meter on AC won't read anything or just momentarily blink a number, many techs do not know that making it more dangerous to themselves :)
@bigclivedotcom
@bigclivedotcom 4 жыл бұрын
I never trust the discharge resistors in capacitors (if they even have them). They often fail over time. The meter wouldn't have shown much if it was set to AC as the residual charge is DC.
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
the start capacitors usually have an external bleeder resistors, the run capacitors do not and that's a run capacitor :)
@raymondleighton9059
@raymondleighton9059 2 жыл бұрын
instablaster...
@mechanic8031
@mechanic8031 4 жыл бұрын
I like your content, good luck dear friend.
@rayesboy3
@rayesboy3 4 жыл бұрын
As Steve Lav world say, “She ain’t no Taj Mahal”
@johncarcamo6772
@johncarcamo6772 4 жыл бұрын
you know Steve has an APP its called Steve Lav Soundboard
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
I can only guess one winding of bad cond. fan motor open, and it charged the cap when powered up or when contactor chattered at unhooking jumpers. though it was unclear what you was touching when zapped. it could simply be stray/inductive voltage from wires in close proximity, say between thermostat and line wiring causing very low current yet high voltage. on 120vac stuff it;s not uncommon to see as high as 90vac, it could be higher on other voltages and will certainly tingle/wake you up brushed against the back of a hand/finger or other body part. flat grabbing the leads would make it go to near 0 and not feel anything
@jerryr6713
@jerryr6713 4 жыл бұрын
amp clamp suspect fan motor wire to see if power present.
@hvac97849
@hvac97849 4 жыл бұрын
I would guess that the fan never turned off due to the stuck relay, hence premature failure. Nitrile gloves would be in your best interest, just sayin
@amadeusrocks4967
@amadeusrocks4967 4 жыл бұрын
the cap most likely
ТАМАЕВ УНИЧТОЖИЛ CLS ВЕНГАЛБИ! Конфликт с Ахмедом?!
25:37
Happy 4th of July 😂
00:12
Alyssa's Ways
Рет қаралды 63 МЛН
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 59 МЛН
HVAC Motor Basics for Beginners
16:09
Taddy Digest
Рет қаралды 19 М.
New Carrier RTU No Cooling
8:52
Michigan Heating Guy
Рет қаралды 10 М.
TROUBLESHOOTING, DIAGNOSTICS AND RESOLUTION OF A HVAC OR AC UNIT ON A SERVICE CALL
26:38
D2D NY Real World HVAC Simplified
Рет қаралды 63 М.
Is the relay REALLY bad? | Understanding HVAC Electrical Concepts
24:59
Trane RTU With Faulty Blower Relay!  Almost misdiagnosed! #hvac #airconditioner
17:52
Old York Condenser Fan Motor & Capacitor Replacement
26:15
The HVAC Hacker
Рет қаралды 25 М.
AC Not Working?! Blower Motor RELAY not Working
10:23
Sam
Рет қаралды 112 М.
How To Troubleshoot A Bad Control Board! Fan Wont Come On
7:43
The DIY HVAC Guy
Рет қаралды 50 М.
HVAC CONTACTOR Operation, Types, Ratings, Problems, Testing!
16:06
AC Service Tech LLC
Рет қаралды 75 М.
He wasn’t ready … birthday celebrations continue!
0:17
The CrunchBros
Рет қаралды 21 МЛН
What did I eat? 🤪😂 LeoNata Best #shorts
0:19
LeoNata Best
Рет қаралды 9 МЛН