New Carrier RTU No Cooling

  Рет қаралды 10,795

Michigan Heating Guy

Michigan Heating Guy

2 жыл бұрын

www.amazon.com/shop/miheatingguy
Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
amzn.to/3pe2hYH
Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
amzn.to/3n5offb
Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
amzn.to/2JdAcku
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm
#MIHeatingGuy
#MichiganHeatingGuy

Пікірлер: 37
@kenbassett5942
@kenbassett5942 2 жыл бұрын
Compressors going backwards. Typical call when these units are installed the units in the winter and now they dont cool. The blower motor will always spin in the correct direction because it is on a drive. On the ecoblue the drive is built into the blower motor. Old school way is check blower rotation for proper phasing. You cannot do that anymore with any Carrier unit. You must phase them in by checking compressor operation to make sure your low side drops and high side goes up. The high voltage on that unit is done properly. The third leg does attach to the blue on that block. Another thing to check is a setting in the Belimo Zip control. Go to settings then scroll to high limit modification. Enter that parameter until you see temperature. That is the changeover temp between mechanical and free cooling. It defaults to 75 degrees. Change it to 55. Love your vids.
@thomasmillwood2610
@thomasmillwood2610 Жыл бұрын
Appreciate your insight coming from a very green HVAC tech!
@ATSNorthernMI
@ATSNorthernMI 2 жыл бұрын
You should test polarity by opening the indoor blower section and bumping the contactor to see if the motor is going in the right direction. Some meters have a phase testing function like the Fieldpiece SC-480.
@MiHeatingGuy
@MiHeatingGuy 2 жыл бұрын
Can't do that anymore All the new rooftops are on drives
@danobrien3109
@danobrien3109 2 жыл бұрын
Seen this a number of times over the years. Too bad that installers don’t know this about three phase power. Just switch any two wires and problem solved. Would save these type of service trips and maybe save some equipment components. 👍👍🇨🇦
@CharlesAnsman
@CharlesAnsman 2 жыл бұрын
Still need to check the blower rotation
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 2 жыл бұрын
@@CharlesAnsman you can't do that with the new units. The VFD corrects the power phasing for correct rotation. Same with the axion fan.
@rwood1995
@rwood1995 10 ай бұрын
@@AmericanFarmerHVAC2024 then he doesn’t have a rotation problem??
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 10 ай бұрын
@@rwood1995 no, what I meant is you can't just look at the blower rotation and assume the phases are correct because the vfd will always have it corrected for the blower. The only way to know is to test the compressors.
@williamserver4332
@williamserver4332 2 жыл бұрын
Will take a while for those suckers to cool down. Great video
@acrepairnearme
@acrepairnearme 2 жыл бұрын
Interesting case)). Yeah, maybe the polarity is wrong. Since they newer use it as A/C, only as gas heat the problem appears only now. I usually put a wet rug on the compressor head, disconnect the compressor and run the fan to save time on return. Please tell me more about that orange controller. (I'm residential HVAC tech from California)
@murkyturkey5238
@murkyturkey5238 2 жыл бұрын
Wet rag and run the fan to cool the compressor back down? Lol I always just wait like a dummy 🤦‍♂️
@watermanone7567
@watermanone7567 2 жыл бұрын
Belimo (if it is the same company) has made electronic/electric control motors for a very long time. Used to make good stuff. I don't know if they got bought out or not.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
That is a Belimo brand economizer controller. The easiest out there to set up. They are, in my opinion the top of the heap. Next would be the Honeywell Jade. The Belimo, you set your zip code and it configures the enthalpy sensor settings. You can navigate the settings super easily. You can test the system in cooling from the controller.
@deanmartin1966
@deanmartin1966 2 жыл бұрын
Good video, thanks for sharing.
@MasterLexusTech
@MasterLexusTech 2 жыл бұрын
Who else is surprised he didn’t check and condemn the heat exchanger?
@wonderhomie2011
@wonderhomie2011 2 жыл бұрын
Carrier is currently flip flopping from the honeywell jade control, back to the old honeywell control that sits on top of the economizer back to blemo 🤷‍♂️
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 2 жыл бұрын
Rushing units out the door.
@andrewedis9907
@andrewedis9907 2 жыл бұрын
Ouch poor compressors I hope they're OK
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
Love those Belimo Zip economizers. Easy to set up, troubleshoot and test operations......I'd also verify the XFMR is also tapped correctly. Those Carrier RTU'S are very easy to work on and troubleshoot. Not much to them. Those new Axial Vane fans are a trip ( Eco blue )
@c21meister
@c21meister 2 жыл бұрын
Those eco blue keep dying
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
@@c21meister haven't had that happen yet, but it wouldn't surprise me
@danieljones5135
@danieljones5135 2 жыл бұрын
Man, they are horrible to work on. Not tech friendly at all.
@throttlebottle5906
@throttlebottle5906 2 жыл бұрын
nice, they don't usually oil as good running backwards, the oil may all leave and not return and obviously no gas/liquid cooling. winter or not, always check them for rotation. ☠ or better yet, unhook the compressor contactors coils, so they wont even try to run. 😁
@markhoffmann5941
@markhoffmann5941 9 ай бұрын
condensate trap vent should be on the outlet side...
@douglascervantes773
@douglascervantes773 2 жыл бұрын
Hey I think the wiring is wrong did you figured it out or do you have a recently video
@Techhead777
@Techhead777 2 жыл бұрын
Whats the name of the phone case you use? I saw it in your previous rooftop video but I couldn't make out the letters on the case. If it's not an OtterBox, why did you go with that brand? Thanks.
@MiHeatingGuy
@MiHeatingGuy 2 жыл бұрын
Supcase
@Techhead777
@Techhead777 2 жыл бұрын
@@MiHeatingGuy Thanks!
@c21meister
@c21meister 2 жыл бұрын
I thought carriers had a controller that would change phase rotation for you? Or am I thinking of trane?
@MiHeatingGuy
@MiHeatingGuy 2 жыл бұрын
On indoor blower
@DW-bo3qw
@DW-bo3qw 2 жыл бұрын
The trane units have a phase monitor on them
@JCT442
@JCT442 2 жыл бұрын
Installers strike again... drats!
@murkyturkey5238
@murkyturkey5238 2 жыл бұрын
I haven’t seen that economizer controller
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
Those Belimo Zip economizers are the best out there and easiest to set up
@MariosACandRefrigeration
@MariosACandRefrigeration 2 жыл бұрын
brand new RTU with 100000 miles LOL.
@steveblake8766
@steveblake8766 2 жыл бұрын
62 Thumbs uP
Carrier rtu AC not cooling
18:08
Curious HVAC Guy
Рет қаралды 19 М.
Clown takes blame for missing candy 🍬🤣 #shorts
00:49
Yoeslan
Рет қаралды 15 МЛН
Does size matter? BEACH EDITION
00:32
Mini Katana
Рет қаралды 19 МЛН
Incredible magic 🤯✨
00:53
America's Got Talent
Рет қаралды 80 МЛН
100❤️
00:19
MY💝No War🤝
Рет қаралды 23 МЛН
Don't mistake it for a bad control board Carrier rooftop
5:18
Michigan Heating Guy
Рет қаралды 12 М.
Trane & Carrier Package Units Not Cooling
15:17
HVACR Survival
Рет қаралды 21 М.
Lennox RTU not cooling
10:51
Curious HVAC Guy
Рет қаралды 6 М.
Rooftop Unit Not Cooling-HVAC Service Call
11:04
HVAC Tech Tips
Рет қаралды 21 М.
RTU Operation & Sequence
6:07
Tec Tube
Рет қаралды 8 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 21 М.
CARRIER NO COOLING CALL
32:11
HVACR VIDEOS
Рет қаралды 526 М.
TROUBLESHOOTING, DIAGNOSTICS AND RESOLUTION OF A HVAC OR AC UNIT ON A SERVICE CALL
26:38
D2D NY Real World HVAC Simplified
Рет қаралды 63 М.
CARRIER AC WITH A BLOWN FUSE
23:31
HVACR VIDEOS
Рет қаралды 86 М.
York 25 Ton HVAC Rooftop Unit Replacement - How Pipe Doctor Gets It Done!
18:50
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 30 М.
Qual você NÃO comeria?
0:14
F L U S C O M A N I A
Рет қаралды 47 МЛН
Хитрая ТАТАРОЧКА!😜 inst: psawkin
1:00
Petr Savkin
Рет қаралды 2,2 МЛН