Fieldpiece SVG3 Micron Gauge

  Рет қаралды 80,269

Fieldpiece Instruments

Fieldpiece Instruments

11 жыл бұрын

Fieldpiece SVG3 Micron Gauge

Пікірлер: 48
@bsrodeo7s
@bsrodeo7s Жыл бұрын
Mine works perfectly! I always use Core Removal Tools and attach to Schroeder valve. Vacuum below 300 in 2 1/2 minutes. I love fieldpiece for HVAC!
@HousesandCars
@HousesandCars 6 жыл бұрын
After having trouble yesterday with a leak and a new SVG3, I decided to do some research. A lot of people are saying this gauge leaks on Amazon. I also swapped valves and hoses and came to the same conclusion after buying a new valve to isolate it and to be sure it has a leak.
@JerryLynch2
@JerryLynch2 3 жыл бұрын
Bought it last year. I have all the Field Piece equipment. I never thought for one min they would make something so worthless. I used it three times, total junk. It's in the bottom of one of my tool buckets. Why would you risk losing customers over 175.00?!
@MagnoTubertine
@MagnoTubertine 3 жыл бұрын
Got a link for the tools?
@purrungas2012
@purrungas2012 Жыл бұрын
Is it Bluetooth? For the app?
@riceball4u172
@riceball4u172 3 жыл бұрын
I have the same gauge, I test pulling vacuum between 2 new appaion core remover, the number keep going up. Try on different new core remover, same. Reading other comments, it seems like the micron gauge defective
@bsrodeo7s
@bsrodeo7s Жыл бұрын
Remember to clean your Micron gauge with 91% Rubbing Alcohol! Occasionally.
@christofergoncalez431
@christofergoncalez431 Жыл бұрын
uma bosta, dinheiro que joguei fora.
@obrienblagrove435
@obrienblagrove435 5 жыл бұрын
A very simple and easy to use instrument ,for the cost well done fieldpiece ,expecting next version to be even more accurate and easier
@clarkkent7257
@clarkkent7257 10 жыл бұрын
the best hing about the svg 3 is the monster sized digits and the leak rate indicator being on a display bottom by itself and no other numbers to distract you. got a BluVac too, and sometimes all the numbers can confuse a guy.
@leanorlando
@leanorlando 11 жыл бұрын
Nice!!! Can't wait to get mine.
@emsj86
@emsj86 11 жыл бұрын
Yeh I use two 1/2 hoses with 3:8 and 1/4 ports. Than a vacuum tee. Than two appion vac rated core removals with my micron guage attached to the suction CRT. Very fast and works great better to not use gauges at all. Guages just add time and possible leaks
@marvinhalvorsen2358
@marvinhalvorsen2358 7 жыл бұрын
Works very well for me
@peteaulit
@peteaulit 11 жыл бұрын
... continued part 3 - to answer someone's question about hoses, yes you can buy 1/2" hoses with 3/8 + 1/4" fittings. Amongst other brands, Appion happens to have a wonderful kit, the "megaflow kit", that works great. I priced out the individual parts and it's cheaper to buy the whole thing. I'm not working for them but just enjoy their stuff, like the TEZ 8 by the way, worth every penny ! ask away if you have more questions
@jayking3196
@jayking3196 8 жыл бұрын
I had this gauge. Used it three times micron reading all over the place had to use the guy I was working with his Bluvac all three times. Called fieldpiece not helpful at all. I now have a Bluvac and this gauge is absolutely worthless to me. The Bluvac LTE is about 20 bucks more and is a much better micron gauge.
@elmeradams8781
@elmeradams8781 6 жыл бұрын
I just bought one. It is super accurate. I don't yet know if it leaks internally, that's the rumor on amazon. I'll keep this updated.
@elmeradams8781
@elmeradams8781 6 жыл бұрын
Turns out it does leak internally. It's too bad it's very accurate and built quite sturdy. But had to return it since I need reliable diagnostics.
@peteaulit
@peteaulit 11 жыл бұрын
... continued - I happen to buy a l lot of those new toys, sorry tools, and test them. So far I have a preference for the Bluvac but this one works fine too. I would've hoped that instead of a brass tee fitting they would've included a brass extension because there is rarely enough space by the access valves, especially when using core tools, to attach the gauge directly to it, like he's doing it in the demo. ...to part 3 i guess
@artbykeenan
@artbykeenan 4 жыл бұрын
Where can i get those small swivel valve on the vacuum
@mygripe
@mygripe 10 жыл бұрын
when can we get a video on the SC77 meter?
@EddieLeverich
@EddieLeverich 11 жыл бұрын
nice micron gauge and at a nice price!! Question, do you make a 1/2" hose with 3/8 and 1/4 fittings?
@ahmedbelarouf5496
@ahmedbelarouf5496 10 жыл бұрын
Cant find your products in the uk
@clarkkent7257
@clarkkent7257 10 жыл бұрын
how the heck r you supposed to hear the vacuum alarm over that noisy tez 8?????
@awsom70
@awsom70 11 жыл бұрын
Awesome gauge! Had one for about 6 weeks. Its reliable and tech friendly! Testo 552 sucks. I had nothing but problems with my testo loosing calibration. I love my fieldpiece so far! Good jon fieldpiece!!!
@peteaulit
@peteaulit 11 жыл бұрын
so yes, you want to have vacuum rated hoses and core tools because everything leaks, just at a different rate. yes, you want to be as close as possible to the system to read a vacuum, hence the gauge attached to the core tool on the valves. If not, you'll be reading a vacuum at the gauges or the pump. yes, try to eliminate as many mechanical connections as you can between the system and the pump. No gauges are necessary while pulling a vacuum if you respect simple procedures.
@pablogaviria9265
@pablogaviria9265 Жыл бұрын
It would have been best to Mount the Vacuum Gauge DIRECTLY to the Blue Valve on the Recovery Bottle. That way the Vacuum gauge is FARTHEST AWAY from the Pump ! In order to get the MOST ACCURATE Reading.
@clarkkent7257
@clarkkent7257 10 жыл бұрын
testo had a quiet recall on the 552. i had mine replaced and it's worth every penny. what did you do about ur 552?
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 6 жыл бұрын
clark kent What's the recall issues?
@CletoCelto
@CletoCelto 3 жыл бұрын
Cost price in india?
@johnaccer4855
@johnaccer4855 11 жыл бұрын
ey...bought one 'bout amonth ago and used it several times. Its ok but it aint no testo 552. 552
@emsj86
@emsj86 11 жыл бұрын
Just ordered one today bc my supco acts up all the time
@davidsmallwood6949
@davidsmallwood6949 9 жыл бұрын
if you pull the schrader to pull a vacuum faster, what happens when you put the schrader back in? you have start all over again
@khoatran9560
@khoatran9560 5 жыл бұрын
Thats the whole point of the schrader removal tool/valve. It has a valve to close off the system once the schrader is removed, and put the schrader back in without letting air back in.
@gtownhvac1640
@gtownhvac1640 5 жыл бұрын
What about with the fieldpiece vacuum????????
@nasserkizito3852
@nasserkizito3852 4 жыл бұрын
How much
@emsj86
@emsj86 11 жыл бұрын
Bc it rises up doesn't that mean you have a leak small but a leak or it that normal for it to rise up to say 800 or even 1000 over an hour
@khoatran9560
@khoatran9560 5 жыл бұрын
The reason that a micron is rising back up is because of remaining moistures. When you’re pulling a deep vacuum, the moisture inside the system freezes, and that couldnt be vacuum since its stuck frozen inside the system. You’re supposed to do triple evac with nitrogen. Thats what i do on my jobs, takes 30 minutes longer, but i can get a much more steady micron reading than without triple evac. What i do is let it vac to 500 microns, close off 3/8 vacuum side and open the charging hose with a little bit of nitrogen in it. Then close it off and let the nitrogen sit for about 10 minutes. Then open the 3/8 vacuum side. Rinse and repeat 3 times. I have the fieldpiece 4-port manifold with micron gauge. I pull down to anywhere from 300 to 100 microns, and would only go back up by 10-20 microns. Sometimes id get lazy and dont do triple evac, i could see microns go back up by 100-150 microns, still held around 500-600 microns.
@a02endless15
@a02endless15 4 жыл бұрын
I ended up putting a magnet on mine .
@nasserkizito3852
@nasserkizito3852 4 жыл бұрын
How much for checking leakage
@nasserkizito3852
@nasserkizito3852 4 жыл бұрын
Cell WhatsApp number+256700977226
@AngelofZul
@AngelofZul 8 жыл бұрын
Worst Vacuum gauge on the Market period!I have owned 2 of these. And the same problem occurs. The name should be Fieldpiece of Sh%@! Or re name this product "OL Gauge"Because that's all this thing ever reads. "OL"
@collind17
@collind17 6 жыл бұрын
@TheHandofGod I had one for 1 month before it stoped reading acutely and cost me a couple of go backs! I went and got the BluVac pro and haven’t looked back. Fieldpiece equipment is trash!
@vitaliyraletniy5743
@vitaliyraletniy5743 6 жыл бұрын
Fieldpiece, please pull your brains together and make us a right micron gauge. U can do better than this. And by all means don't do it with Bluetooth, we need not 15ft distance range bit 500ft. So i can monitor it sitting in my car.
@peteaulit
@peteaulit 11 жыл бұрын
several things I'd like to comment on here. - please go to Jim Bergam from Trutech Tools explanation about the Bluvac gauge to get better and more accurate technical explanations about the whole process and tools; this guy seems nice but not vey accurate in his explnations. - DO NOT tighten the fittings like a brute, just like he's doing, you will weaken and ultimately destroy the gaskets and create leaks. I have to cut the comment here....
@4bearsi678
@4bearsi678 4 жыл бұрын
These are JUNK and their warranty/CS is HORRIBLE! I’ve had THREE and they’ve all leaked. Got a CPS and it works great
@ramirobanda93
@ramirobanda93 5 жыл бұрын
Piece of crap, had 3 bad gages in one week. My appion gauge was holding 300 microns , and this crap went to atmosphere pressure
This One CONFUSED Me…
15:25
Quality HVACR
Рет қаралды 48 М.
Leak Repair, and First Use of Fieldpiece MG44 Micron Gauge
17:44
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 160 МЛН
Heartwarming Unity at School Event #shorts
00:19
Fabiosa Stories
Рет қаралды 17 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:26
CRAZY GREAPA
Рет қаралды 3,5 МЛН
Fieldpiece Pro Tip | Pulling a Vacuum Easier, Faster, and Better
6:12
Fieldpiece Instruments
Рет қаралды 4,2 М.
Cleaning micron guage sensor
4:04
Kenneth Casebier
Рет қаралды 6 М.
How to Clean a Micron Gauge
4:17
HVAC School
Рет қаралды 29 М.
Testing the Fieldpiece VP67 Vacuum Pump
6:43
Apartment Maintenance Pro
Рет қаралды 4,7 М.
Best Practices Vacuum With Jim Bergmann Full Version
26:01
Fieldpiece Instruments
Рет қаралды 35 М.
MG44 Wireless Vacuum Gauge: Three ways of vacuum| Fieldpiece Europe
1:46
Fieldpiece Instruments Europe
Рет қаралды 4,1 М.
Digital HVAC Gauges or Wireless Probes | Which should YOU buy??
17:00
Can You Trust Your Micron Gauge?
6:00
HVAC Shop Talk
Рет қаралды 7 М.
Three ways to use the Wireless Vacuum Gauge MG44
7:02
Fieldpiece Instruments
Рет қаралды 32 М.
How Many Balloons Does It Take To Fly?
00:18
MrBeast