Fire Alarm Generator Emergency Shutdown | Wiring and Installation Part 1

  Рет қаралды 7,252

NIC’S - SYSTEMS & ELECTRIC

NIC’S - SYSTEMS & ELECTRIC

Күн бұрын

Пікірлер: 90
@wibwabz
@wibwabz 2 ай бұрын
IDEA FOR GARAGE FIRE ALARM TESTING: maybe try the fog machine in the attic of the garage to see how long it takes for the fog to go down to a smoke detector. Also, if you're looking for an auto extinguishing solution for your generator building that's not sprinklers, you should look at the AFO Fire Ball things. When there is fire, they explode and launch powder everywhere, extinguishing a small fire.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
I'm thinking it probably wouldn't ever make it down to a smoke detector the front area might but I doubt the back area would as it is sealed off and I may look into that type of extinguisher
@kimcorradini
@kimcorradini 2 ай бұрын
Have a google for stat-x they do fire extinguishers
@kimcorradini
@kimcorradini 2 ай бұрын
@@nics-systems-electric stat-x is a good Fire extinguisher
@mirkovillanueva7101
@mirkovillanueva7101 2 ай бұрын
What about the September fire ALARM test
@mirkovillanueva7101
@mirkovillanueva7101 2 ай бұрын
@@nics-systems-electric❤❤❤❤❤❤❤❤❤😂❤❤❤❤❤❤❤❤❤❤❤❤❤
@MaxShaw-243
@MaxShaw-243 2 ай бұрын
You’re filming job is getting really good
@dashcamandy2242
@dashcamandy2242 2 ай бұрын
0:02 - Yes, Nic, we all know you have one of the coolest garages in North America, stop rubbing it in. 🤣 Seriously, though, your garage is a physical representation of your career progression. A hands-on résumé instead of a paper résumé. It's OK to flex a bit. 2:36 - I was going to suggest this very thing, but it seems you'd thought of it as well. 11:14 - LOL ...can't wait for Part 2!
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Physical resume, I like it!
@iiileoniii1572
@iiileoniii1572 2 ай бұрын
Very nice to see my feedback implemented this Quick :D Can´t wait to see this in action.
@noxious_nights
@noxious_nights 2 ай бұрын
As soon as I saw this video I was like, hey, didn't someone just comment about doing this?
@Sparky-joystick.1308
@Sparky-joystick.1308 2 ай бұрын
That's great idea the case of a fire generator shed shut down automatic that's pretty smart 👌
@hkprogram837
@hkprogram837 2 ай бұрын
really like this new "style" of videos !!
@TheFirePanel
@TheFirePanel 2 ай бұрын
Damn you got this one up pretty quick! Nice to see it coming together. Regarding that module, if it were me I'd just keep the Notifier one on there. As long as it works, it's great for a system in your home.. And not paying extra $60 for a module? Very worth it.
@Γιωργος-ι3ξ
@Γιωργος-ι3ξ 2 ай бұрын
Nice addition to the fire alarm system!
@kc0eks
@kc0eks 2 ай бұрын
Always love seeing your next project.
@Dilsonalarmsandelectric
@Dilsonalarmsandelectric 2 ай бұрын
Nic if you wanna make all your systems on your property notifier for the garage system I recommend the notifier nfw2-100 it’s basically the same thing as a fire light panel, but it notifier version. I think those panels look nicer, but nobody got time for that
@kc0eks
@kc0eks 2 ай бұрын
You should do some networking stuff, wireless p2p, cameras connected to relays and security system, etc etc. bet you could come up with some wild automations
@All_ConsumingBandu
@All_ConsumingBandu 2 ай бұрын
You're my favorite KZbinr! Keep up the great work 👍
@bread_cat__
@bread_cat__ 2 ай бұрын
Awesome job Nic!!
@MaxShaw-243
@MaxShaw-243 2 ай бұрын
For September testing you should do the pull station in the tower
@FireGuy1500
@FireGuy1500 2 ай бұрын
Maybe test the generator heat detector for a fire alarm test sometime, and is the tone on the garage fire alert alarm in the house ever going to be changed
@iashbanen
@iashbanen 2 ай бұрын
Nice very nice video!
@COSMIC_SECRET
@COSMIC_SECRET 2 ай бұрын
I suggest making the low/high temp monitor shut the generator down if it’s above a certain temperature like 93°C+ so the generator doesn’t overheat
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
It's not necessary really as it just to give me a heads up that the generator will exceed its maximum temperature soon because it will shut down by itself at high temperature. And 93 Celsius would be way too high that would be 199 Fahrenheit
@InstrumentFan2510
@InstrumentFan2510 2 ай бұрын
What back box do you use for Pull stations and horn strobes?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Pull stations go on single device boxes and most notification devices can go on device box or 4 in.² or octagon.
@InstrumentFan2510
@InstrumentFan2510 2 ай бұрын
@@nics-systems-electric I meant, what model is the back box you use for Pull stations and notification appliances?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@InstrumentFan2510 there's probably 30 different boxes depending on what your doing
@InstrumentFan2510
@InstrumentFan2510 2 ай бұрын
@@nics-systems-electric If it were a Simplex T-bar, what model back box is recommended?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@InstrumentFan2510 single device box
@robertbeyers1308
@robertbeyers1308 2 ай бұрын
Nic great idea. On setting the fire alarm to turn off the generator. But I do have a on your particular setup. I do you know you have said that you do not have natural gas. But this question I think this is a valid question for those who have natural gas setup. Is it possible to put a electronic shut-off valve on a natural gas line for the system to close the gas valve when it is not running. And to open when the generator is running? And I mean with the auto controller.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Yes it has auxiliary relays that can be programmed
@keithpierce8458
@keithpierce8458 2 ай бұрын
Nice addition
@Camporito25
@Camporito25 2 ай бұрын
Hi! Tomorrow, I'm starting high school. I'm excited and nervous.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
I wouldn't worry. I started during Covid with everything being crazy and different and I still made it somehow lol
@adventuresquadofficial
@adventuresquadofficial 2 ай бұрын
Good vid when are you going to test it
@AYDEN_OFROBLOX
@AYDEN_OFROBLOX 2 ай бұрын
how long did it take in total from start to end?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
A couple hours
@AYDEN_OFROBLOX
@AYDEN_OFROBLOX 2 ай бұрын
@@nics-systems-electric when do you think the next part will be out?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@AYDEN_OFROBLOX Wednesday
@pilotboy
@pilotboy 2 ай бұрын
your camera was out of focus for a lot of the video, maybe try use a smaller aperture size! other than that, great video keep up the good work
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
When you say a lot of the video how much do you mean? I know there was a specific section where the auto focus was tracking me as I didn't lock it off to manual focus?
@pilotboy
@pilotboy 2 ай бұрын
@@nics-systems-electric when you were doing the boxes and it was focused on your head
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@pilotboy yup that's what I was talking about I didn't switch to manual focus.
@pilotboy
@pilotboy 2 ай бұрын
@@nics-systems-electric oh ok alg
@Aliwff
@Aliwff 7 күн бұрын
Amazing
@UKsystems
@UKsystems 2 ай бұрын
Great video
@JakeOfficial2002
@JakeOfficial2002 2 ай бұрын
Nice video
@KhucbaosonKhucbaoson
@KhucbaosonKhucbaoson 2 ай бұрын
Nice video 🎉
@The_FireAlarmGuy
@The_FireAlarmGuy 2 ай бұрын
Wow that nice Nic 😊
@Dilsonalarmsandelectric
@Dilsonalarmsandelectric 2 ай бұрын
Nick, you should put a outdoor advance outside the front door of your house if the house catches on fire and call 911 to report the fire the fire department can see the flashing strobe as they arrive
@DozIT
@DozIT 2 ай бұрын
I don’t think auto-dialers to 911 are legal anymore, or if they are it’s not best practice. Which is where the whole 24/7 monitoring services came from. He does have SMS notifiers which are the next best thing (aka self-monitor)
@Dilsonalarmsandelectric
@Dilsonalarmsandelectric 2 ай бұрын
@@DozIT I don’t mean the system is monitored. I mean, he calls 911.
@DozIT
@DozIT 2 ай бұрын
@@Dilsonalarmsandelectric ahh okay! That’s how commercial fire systems in my area work (strobe to notify dept which building - and to help find the CACF room)
@ebelray6890
@ebelray6890 2 ай бұрын
Is this the first time the generator is out of its home since you bought it?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
No every time I service it I take it out
@RossTheGenMan
@RossTheGenMan 2 ай бұрын
Great video. Just wondering if the generator is shut off but not by the module... if the module will try to restart it.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
No it will send an error email that the generator has shut down
@eDoc2020
@eDoc2020 Ай бұрын
Even if the module tries to restart it won't be able to. As long as the alarm relay is closed the ignition will be killed. It would just crank but not fire.
@kimcorradini
@kimcorradini 2 ай бұрын
I think you should add a CO2 detector to the generator building
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
I don't really see the purpose it's not a occupied space
@Dani8lYT
@Dani8lYT 2 ай бұрын
Disable autofocus on your new camcorder? It only blurs out the background.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
That's normal and desired for blurred background with wider aperture
@Dani8lYT
@Dani8lYT 2 ай бұрын
@@nics-systems-electric It’s troubling to me; but it shouldn’t be doing that for when you’re present in the foreground. Seems strange to have it change automatically.
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@Dani8lYT that's how it's supposed to be
@Dani8lYT
@Dani8lYT 2 ай бұрын
@@nics-systems-electric Is it fixable?
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
@@Dani8lYT I'm not sure what you mean there's nothing wrong
@cjelevators223
@cjelevators223 2 ай бұрын
Yessss
@benrodriguez4905
@benrodriguez4905 2 ай бұрын
Hi nic how is it going
@kevinbradt835
@kevinbradt835 2 ай бұрын
Would it be better to remove all wires from terminal 3 on the control box and connect terminal 3 of to control box to com on the fire alarm relay and the. Connect the wire that returns to the control box enclosure to the normally closed terminal on the alarm relay and then the other end to the generator and add a negative wire to the normaly open of the alarm relay to turn off the generator and to prevent the generator controller from trying to start the generator again
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Not sure why that would be necessary sounds more complex
@hotbytesB
@hotbytesB 2 ай бұрын
Where is Wednesday video at?
@mircomamsecosirensnalarms
@mircomamsecosirensnalarms 2 ай бұрын
how about you make he generator also shut off when the hi temp alarm sounds
@nics-systems-electric
@nics-systems-electric 2 ай бұрын
Not necessary the generator will do that by itself the high temp supervisor is just meant to give me a warning that the generator is getting near its automatic shut off temperature
@AidenTheBestAiden
@AidenTheBestAiden 2 ай бұрын
@christinecampbell9348
@christinecampbell9348 2 ай бұрын
For your noterfire fire alarm system in your house. In your furness room, don't you need a carbon monoxide alarm?
@TheMcGeeTwins
@TheMcGeeTwins 2 ай бұрын
It’s a electric furnace so he doesn’t need it
@Harper_DobniYT
@Harper_DobniYT 2 ай бұрын
He doesn’t have one
@christinecampbell9348
@christinecampbell9348 2 ай бұрын
​@@TheMcGeeTwins thanks for the knowledge
@chrisgamecave
@chrisgamecave 2 ай бұрын
Quick correction, its Notifier. Not noterfire
@Nicmrict879
@Nicmrict879 2 ай бұрын
fire controll pannel is 5 year old
@gamerboy12970
@gamerboy12970 2 ай бұрын
Nice video
Fire Alarm Automatic Damper Closing In Generator Building
24:35
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 6 М.
This dad wins Halloween! 🎃💀
01:00
Justin Flom
Рет қаралды 64 МЛН
Human vs Jet Engine
00:19
MrBeast
Рет қаралды 190 МЛН
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 130 МЛН
Fire Alarm And Emergency Systems September Testing | Pre-Alarm in action! (nighttime)
32:23
90% Don't Know About This Fatal Generator Connection
11:17
HAXMAN
Рет қаралды 830 М.
My house system overview
12:49
Doc Zwy
Рет қаралды 3,7 М.
Installing A Red Fire Alarm Strobe Light On My Generator Building.
15:20
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 17 М.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Рет қаралды 584 М.
8 Wire Stripper Features Everyone Should Know
13:55
LRN2DIY
Рет қаралды 1,9 МЛН
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Backyard Maine
Рет қаралды 845 М.
Setting Off Fire Alarm System HVAC Duct Detector With Smoke Machine Into Air Duct!
12:13
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 20 М.
This dad wins Halloween! 🎃💀
01:00
Justin Flom
Рет қаралды 64 МЛН