informative vid . the vapor movement will find it's way through the untaped gaps and rot the ply though surely
@drc69402 жыл бұрын
You really should have insulated the upstand because there was no reason not to. Now you have a warm area meeting a cold so you’re bound to have constant condensation during winter
@harvisingh6671 Жыл бұрын
No vapour barrier between deck and insulation ?
@JulesSenior10 ай бұрын
exactly what I thought... that will come back to haunt them (the home owner)
@onesmasodero34782 ай бұрын
Can the steel beams be replaced with timber for a single three bed room?
@dinendale6663 жыл бұрын
It looks like you haven’t tapped the joints on the insulation panels!
@user-ti9yn8wg6o8 күн бұрын
why not to use joist hangers, then you wouldn't need to level the existing joists as much nor chisel the notch?
@TheBgloria8 ай бұрын
What’s the slope drop per inch on each foot? I would like to do something similar. Nice vid. Thank you!
@ijjo-lr5yp6 ай бұрын
Hello, thanks for the knowledge shared....Are these roofing systems applicable in tropical countries?....dont see such here yet interested
@philjays13653 жыл бұрын
looks like you forgot to install a vapour control layer under the insulation on top of timber deck.... failed LABC regs. likely roof will decay
@northeastcorals2 жыл бұрын
I was wondering about that
@Sarin-Dan Жыл бұрын
Not just me that noticed that then.....
@garethheard1944 Жыл бұрын
Vapour control layer can be added inside, taped and sealed under joists.
@trevorjmayeku8312 жыл бұрын
Make a video that has the flat roof built from scratch
@zakwinning27173 жыл бұрын
Underlay had not been laid to the fall of the roof ?
@markpearcey-ph5nh Жыл бұрын
Someone's gonna break an ankle, what fucking mess.
@darrenpodger72943 ай бұрын
I will be doing something similar except my bram will have headplate attached and i will be having a 150mm insulation warm roof . Anyone reading this would it be a good i dea to have upright metal posts or lay the beam onto existing wall , thanks in advance .
@engr8102 жыл бұрын
Thanks for information
@ulaland2 жыл бұрын
Genuine questions: why is the upstand for the roof light not insulated ?
@CrazyDutch792 жыл бұрын
Because the owners wife always takes a shit against it .
@triumfdula8830 Жыл бұрын
What would be the max. span (wall to wall) for a 2 by 12 soft wood ceiling joists (12 being vertical), that would not bend under snow or it's own weight? i'm looking for a direct approximate answer, i just don't get the online tables ?
@padraigholohan4778 Жыл бұрын
lots and lots of mistakes and essential points left out in this build. I wouldn't be surprised if the ply moulds after 2 years.
@lassynyoni7667 Жыл бұрын
What size ibeam you can use on a 10m x 18mm flat roof residental garage?
@Av3staxx8 ай бұрын
Hi can you tell me please what thickness of plywood you use First if you tell me that I appreciate thank you
@milant7776 ай бұрын
18MM
@rileyscott58272 жыл бұрын
Could you show how it looks after it rains? I just had my flat roof redone and there are a bunch of pools of water and it looks like possibly air pockets....not sure. It's making me nervous.
@londonengland70962 жыл бұрын
Hey did you get problem sorted? I need to get my flat roof done and had 8 people around and getting nervous I may choose wrong person
@hongkong20172 жыл бұрын
You guys rock!! Fantastic work!!
@waynejaques650410 ай бұрын
Where's the vapour barrier ?
@mattdawkins6256 Жыл бұрын
The installation of the felt is totally wrong. You never cross bond layers, a venting partial bond layer should have been used as a base layer, the joints in the deck need to be taped, and the deck should have been primed.
@punxneverdead6662 жыл бұрын
Quite a few things wrong with this roof.
@asdaasda4967 Жыл бұрын
What size is that steel?
@watchtime90722 жыл бұрын
Would you mind telling me what size steal beam have you used ?
@padraigholohan4778 Жыл бұрын
looked like a 200
@jameseveritt21562 жыл бұрын
Good job though.
@lashonstevens13743 жыл бұрын
How thick is your plywood here?
@TheNorthernmunky2 жыл бұрын
18mm
@jameseveritt21562 жыл бұрын
Didn't see any pad stones
@JustJohnyDays Жыл бұрын
not the best noggins 9.14
@MrFlatroofer2 жыл бұрын
This is not a warm roof.
@TheNorthernmunky2 жыл бұрын
Why? Looks to be done correctly?!
@MrFlatroofer2 жыл бұрын
The decking should be under the insulation and the felt should be on top of the insulation.@@TheNorthernmunky
@TheNorthernmunky2 жыл бұрын
Wouldn’t both ways work well? Having the ply under the insulation may also cause cold bridging from the edge of the ply in to the void?! We usually put ply under and over and we insulate all the perimeter joists
@MrFlatroofer2 жыл бұрын
@@TheNorthernmunky I would think the felt should cover the edge of the ply. Where is the void?