Double Ended Forward Converter Working with Wave-forms | 2 Transistor Forward converter

  Рет қаралды 8,834

Foolish Engineer

Foolish Engineer

Күн бұрын

Пікірлер: 35
@solapowsj25
@solapowsj25 3 жыл бұрын
Absolutely perfect presentation for industrial training. Thanks 🙏🙏🙏
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
Glad it was helpful!
@elmnaoirfer3751
@elmnaoirfer3751 2 жыл бұрын
When determining the appropriate current for welding, does the processor change the pulse width or frequency, based on the feedback?
@Dc_tech386
@Dc_tech386 Жыл бұрын
Ok thanks for information but I have one question does the 2 mosfets use one pwm pulse as in not a alternating switching just forward switching from one single pwm pluse from the gate drivers transformer
@mubashir588
@mubashir588 Жыл бұрын
Which software you use for showing the circuit, and the power flow in the circuit? Thanks
@elmnaoirfer3751
@elmnaoirfer3751 2 жыл бұрын
Is there a reverse polarity of the primary coil or not in this system(forward)??
@FoolishEngineer
@FoolishEngineer 2 жыл бұрын
There is no polarity to any coil. just the DIRECTION OF THE CURRENT
@elmnaoirfer3751
@elmnaoirfer3751 2 жыл бұрын
@@FoolishEngineer When determining the appropriate current for welding, does the processor change the pulse width or frequency, based on the feedback?
@andrealfiansah9432
@andrealfiansah9432 2 жыл бұрын
Sir. Is it necessary to add air gapped Transformer for this converter?
@FoolishEngineer
@FoolishEngineer 2 жыл бұрын
Yes
@aniketsawant8000
@aniketsawant8000 3 жыл бұрын
What are the other applications of this ckt other than just computer application??
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
You can use it in DC-DC converter of EVs
@pablorivero8311
@pablorivero8311 4 жыл бұрын
Muchas gracias, si bién conocía las topologías mas comunes esta forma me abrió unas cuantas dudas al encontrarla en máquinas de soldadura, no comprendo muy bien el ingles pero mas o menos entendí el concepto.
@FoolishEngineer
@FoolishEngineer 4 жыл бұрын
Realmente me alegra que te guste. Sigue viendo, compártelo con tus amigos y mantente al día
@mdadil9233
@mdadil9233 3 жыл бұрын
Can you tell me whats the behavior of the circuit under no load ?
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
If there is no load, still the converter will give constant output because of the feedback.
@mdadil9233
@mdadil9233 3 жыл бұрын
Will there be much power consumption !!! Or just minimal like in micro Amps.
@vtorsi610
@vtorsi610 3 жыл бұрын
@@mdadil9233 There is more to this circuit than shown in this video, but if switching of the MOSFETS actually STOPS, then the only power consumption will be that of the Feedback Logic. NO-LOAD Mode can be called sleep mode, micro-power stand-by mode or chirp mode. You need to specifically design the feedback circuit to properly handle No-Load Mode - ie soft-start.
@stark_energy
@stark_energy 2 жыл бұрын
This topology is using advantage of transformer (for step down/up that only works for AC) to be used in DC, amazing idea! This is an alternative for converting DC to DC voltage in high power requirement instead of using Buck/Boost converter.
@pradeepbhatade2129
@pradeepbhatade2129 2 жыл бұрын
How to calculate input output capacitor in forward topology and mosfet and diode also
@zikermu
@zikermu 3 жыл бұрын
Bravo for this excellent video. It is very educational and pleasant to follow. Happy New Year.
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
Thank you so much for watching!! Please don't forget to subscribe to our channel
@garinanggara8358
@garinanggara8358 3 жыл бұрын
Can we use full bridge rectifier ?
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
The Input is DC only, we don't need to use a full bridge rectifier
@garinanggara8358
@garinanggara8358 3 жыл бұрын
@@FoolishEngineer oh okay thank you. oh btw I, before you answering my question, i try full bridge rectfier, and some how the current at the primary rose so high, the power mosfet at the primary get super hot. could you explain why?
@mdadil9233
@mdadil9233 3 жыл бұрын
It may be because... the bridge act as a voltage multiplier. Thatswhy your voltage increased
@leo46728
@leo46728 3 жыл бұрын
Why the D3 and D4 will on? If on, the current will flow from gnd to Vin. I'm so confusing.
@vtorsi610
@vtorsi610 3 жыл бұрын
NOTE: that D3 and D4 a REVERSED Biased towards Vin. Only when the Mosfets feeding the Primary of transformer are turned off, does the voltage on the Primary become GREATER than Vin. Then, and only then, do diodes D3 & D4 become Forward Biased = ON. The Primary Winding is actually pushing amps back into the Power Supply capacitors! When the the fly-back / kick-back voltage across the Primary Winding drops below Vin, do the diodes ( D3 and D4 ) become REVERSED Biased (again) and turn OFF.
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
Thank you for helping me out!
@rafikulalam9574
@rafikulalam9574 3 жыл бұрын
Great discussion.
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
Thank you so much for watching!! Please don't forget to subscribe to our channel
@foxanderson967
@foxanderson967 3 жыл бұрын
best videos i've seen
@FoolishEngineer
@FoolishEngineer 3 жыл бұрын
Thank you, please subscribe to my channel for more such videos!
@김진형-d9x
@김진형-d9x 5 ай бұрын
Thanks bro 😊
@김진형-d9x
@김진형-d9x 5 ай бұрын
Your my master❤
How does a Zeta converter work? | Zeta Converter Working
10:01
Foolish Engineer
Рет қаралды 13 М.
🎈🎈🎈😲 #tiktok #shorts
0:28
Byungari 병아리언니
Рет қаралды 4,5 МЛН
#behindthescenes @CrissaJackson
0:11
Happy Kelli
Рет қаралды 27 МЛН
Switching inductive load §32.3
12:29
gasstationwithoutpumps
Рет қаралды 11 М.
How does a Cuk converter work? | Cuk Converter Working
11:11
Foolish Engineer
Рет қаралды 36 М.
Basic electronic components
5:00
VP 7 Technical
Рет қаралды 1,1 М.
How does a Half Bridge converter work? | Half Bridge Converter Working
11:46
How does a Full Bridge converter work? | Full Bridge Converter Working
11:13
Таким раствором работать одно удовольствие
1:00
Профессия созидатели
Рет қаралды 954 М.
КАК ЖИВЕТ КВАНТУМ? РУМ ТУР КВАНТУМА!!!
13:51