Ford E-350 A/C Fix Vents Stuck in Defrost

  Рет қаралды 55,750

Daniel York

Daniel York

Күн бұрын

Пікірлер: 64
@acescalade4351
@acescalade4351 2 жыл бұрын
I just fixed one for this nursing home, and I just had a ton of elderly men and woman tell me thank you. I couldn’t take full credit so they asked me to pass along a “god bless and thank you”. 2019 btw
@johnhunt1390
@johnhunt1390 3 ай бұрын
This hack worked for me in 2010 RV E450 Ford. Used the existing connectors and bought nothing extra. Went through area near /behind the shroud and filed it smooth. Thank you bigley.
@FMXMike
@FMXMike 5 ай бұрын
This video saved an hvac tech with no a/c in his van for the last 2 months, thank you!
@kohltonblackwood1243
@kohltonblackwood1243 Жыл бұрын
Fixed my problem and saved me on a 700 mile trip. Thanks a bunch and smart thinking! also tape does work on that splice.
@numerounocleaning
@numerounocleaning Жыл бұрын
I just did exactly what you said and had it ready in about 30mins. So I just wanted to thank you sir your a lifesaver
@Jaredbar
@Jaredbar 2 жыл бұрын
I just fixed my e450 box truck watching this. I like free fixes!
@anthonyrivera7661
@anthonyrivera7661 3 ай бұрын
Thank u so much I did exactly what you did step-by-step. I was able to save the company hundreds of dollars thank you for the support and guidance AC and air is blowing out perfectly.
@thomaschinault7659
@thomaschinault7659 2 жыл бұрын
Been dealing with the same issue for 2 years . 5 min fix thank you. works great now
@jamese.williamsjr.8471
@jamese.williamsjr.8471 3 жыл бұрын
Hi Daniel, You are the Greatest !!!! It Works. I did exactly as you said and It worked. Thanks!!! All the way from Covington Georgia. I can feel the fresh A/C now......
@dandesouto6076
@dandesouto6076 3 жыл бұрын
Hi , I don’t understand were the red tubing come when hi was talking about near the engine, all so I have e 350 same problem
@patrickladue2762
@patrickladue2762 3 ай бұрын
You can separate the firewall engine side from the firewall passenger side at the valve, pull the valve through with a wire taped to it so you can feed it through again. Put a screw in the open hose end of the 3-way valve that is leaking to atmosphere, reinstall it and not have to cut the access hole. I just completed this action with your help.
@MrStreet69
@MrStreet69 Жыл бұрын
100% fully working method, his my new best friend, you don’t need to buy anything, my vents are working again..Amazing work clean looking job done :)
@bigbear2658
@bigbear2658 3 ай бұрын
😎This saved my life over here in FL, thank you thank you 😎
@ljulian80
@ljulian80 6 ай бұрын
Nice and to the point. Best part of it is it works, just did mine!!
@gabdgraieb
@gabdgraieb 2 жыл бұрын
That's nice 👌 I just fixed mine after suffering from the hot weather 😅
@craigcarrillo
@craigcarrillo Жыл бұрын
I have a 1998 Ford E-350 Club Wagon with V-8 gas engine. I developed the identical leak in at my vacuum reservoir or line. The vacuum reservoir and built in check valve is actually hidden under and attached my blower/coil unit which is totally inaccessible. It comes from the factory like that:( I removed my battery and battery tray and with a little pressure my existing check valve and lines pulled out from under the blower/evaporator unit. I disconnected the red line from the vacuum control valve leading to the old reservoir and installed my new factory Ford reservoir under my battery tray to the left of the windshield washer reservoir with a body clip. The vacuum port line comes out straight down from the top of the battery about 11 inches. I literally left everything else in place. I liked it so much better than the reroute here. I believe I may end up rerouting the new vacuum line on the passenger side when I have time and relocate my reservoir behind the dash like you did. I would recommend using automotive or high heat aluminum duct seal if you chose to reroute the line thru your insulation by the dog house. Even though the hole is small and duct taped it's still going into the passenger compartment. I didn't have anything to go by when I did this project. I followed kzbin.info/www/bejne/mpXGi6Grl699ncU
@Jim-ks1dt
@Jim-ks1dt 3 ай бұрын
Confirmed fix on 2013 E350 Box truck. That line runs to a vacuum reserve canister and its so buried in there not worth digging it out and replacing rotted rubber hoses. The vacuum reserve is there for high engine RPM conditions where vacuum is low and keeps the on the setting you have it on during that time.
@Jvcdt
@Jvcdt 3 жыл бұрын
Would I be pulling it off of the firewall and attaching it or off of the connector going up to the top of the motor and connecting it
@luisvazquez6607
@luisvazquez6607 2 жыл бұрын
Thanks a lot man life saving here in fl gets nasty this time of the year 🤘🏽🙏🏽💪🏽
@Potatorq
@Potatorq 5 ай бұрын
Super easy fix! Worked on my 2013 E350
@SafetyMentalst
@SafetyMentalst 5 ай бұрын
It worked Thank You Greatly !
@precisiont5188
@precisiont5188 2 жыл бұрын
Is this similar on my 2008 Ford E-250? Or does mine use a blend door actuator?
@Fr.....
@Fr..... Жыл бұрын
This video help me to make an excellent job, thank you
@Jvcdt
@Jvcdt 3 жыл бұрын
I need to do this so bad because I had the same problem but I still don’t understand what black tube or which part of the black tube you attach the red tube to
@shargrathdehexen3495
@shargrathdehexen3495 Жыл бұрын
Thank you very much for this helpful video!
@mattluongo7763
@mattluongo7763 2 жыл бұрын
Good shit bro. Worked like a charm on my 2012 e250
@aemunguia12
@aemunguia12 2 жыл бұрын
Could you not just slip it through the weather strip instead of drilling a hole? It worked for me though
@danielrufledt5246
@danielrufledt5246 Жыл бұрын
Worked for me also. THANKS!!!
@FelipeMartinin
@FelipeMartinin 7 ай бұрын
I did the bypass exactly like the video. But instead of solving the issue, it went from 0% airflow going to the vents to 5%. The major airflow still goes to defrost. Any suggestion?
@williamcarnline4406
@williamcarnline4406 4 ай бұрын
This worked perfectly,, thanks
@carlosmoreno2387
@carlosmoreno2387 5 ай бұрын
Thanks 🙏 man appreciate very much you’re awesome 👏
@kawirider38112
@kawirider38112 Жыл бұрын
Great video, quick easy fix
@max260max
@max260max Жыл бұрын
Thanks a lot 🙏🏻
@hectoroftroy4005
@hectoroftroy4005 2 жыл бұрын
Worked like a charm! Thx
@freddymejia1100
@freddymejia1100 2 жыл бұрын
Thank you, it worked out well.
@joeyg.2953
@joeyg.2953 3 жыл бұрын
You didn't need to buy a new reservoir and attach to the tubing?
@vicentegonzales3852
@vicentegonzales3852 3 жыл бұрын
Nope !!! I just did it n it work the way he did … that I did also drill hole
@TruckDriver326
@TruckDriver326 2 жыл бұрын
@@vicentegonzales3852 thank i had the same questions. I was thinking I need the reservoir.
@ivanreyes2403
@ivanreyes2403 3 жыл бұрын
Does the airflow, slow down when you accelerate?
@danielyork7916
@danielyork7916 Жыл бұрын
Yes it does especially when there’s strain on the engine. But comes right back
@etubrutus3501
@etubrutus3501 8 ай бұрын
Nice, well done.
@LatinGeorge
@LatinGeorge Жыл бұрын
Hoping this fixes my issue. Thanks!!
@LatinGeorge
@LatinGeorge Жыл бұрын
It worked!!!
@tjlee1595
@tjlee1595 2 жыл бұрын
Solved the issue, thanks
@paulrousseau8882
@paulrousseau8882 2 ай бұрын
This worked, awesome, many thanks. I used this other video to get a bit more details (kzbin.info/www/bejne/mpXGi6Grl699ncU) , but used this simplified fix. As you can see in other comments, the vacuum reservoir and check valve are optional - helpful to stabilize setting under high rpm but not really needed and I suspect the check valve may be the failure mechanism. I cut the sleeve, made a small hole in firewall just for red tubing, reinserted sleeve on other side (although probably not needed), and reused complete connector as is. Did not cut the red tube from connector, just twist with a plier.
@jamesschell1526
@jamesschell1526 Жыл бұрын
I had a glove compartment so I had to relocate it a little bit different yes it works just fine
@DanielRomero-cn3yq
@DanielRomero-cn3yq 10 ай бұрын
Tengo ese problema ahorita mismo no cambia la dirección del viento simplemente conecto un vacío del motor a esa manguera negra que sale de la pared de fuego
@shielduniversity419
@shielduniversity419 2 жыл бұрын
Anyone know if these vans have cabinet air filter?
@HoboThatIsHigh
@HoboThatIsHigh 2 жыл бұрын
If you mean cabin air filter, my van doesn't have one.
@MrMpm3001
@MrMpm3001 9 ай бұрын
The reservoir is needed to store vacuum under WOT.
@ba1868
@ba1868 2 жыл бұрын
Ford engineers are stupid AF. This issue has been around for a decade and has not been corrected. Why the hell is the default position still the defroster?
@justincox7190
@justincox7190 2 жыл бұрын
So you can see out your windshield....it's a safety thing.
@arasb3258
@arasb3258 Жыл бұрын
would be nice if there was a manual way to move the flapper, WITHOUT using actuators or vacuum lines! Such BS design. Who needs this "automatic" BS? Just let me do it!
@carlositio4968
@carlositio4968 8 ай бұрын
Thanks a lot
@TruckDriver326
@TruckDriver326 2 жыл бұрын
I was thinking I need the reservoir.
@cddeandrade1274
@cddeandrade1274 Жыл бұрын
Thanks
@williamaltoon73
@williamaltoon73 3 ай бұрын
Less is more
@lynnh7694
@lynnh7694 Жыл бұрын
It must be a Ford problem, my van is doing the same thing.
@dimuzioservices6107
@dimuzioservices6107 5 ай бұрын
Not clear instructions
@shizzan12
@shizzan12 5 ай бұрын
I agree
@shielduniversity419
@shielduniversity419 2 жыл бұрын
Everyone is doing shitty bypsss on here whats the actual problem
@Mitzoplick
@Mitzoplick 2 жыл бұрын
The problem is either the vacuum reservoir or the vacuum check valve have failed. They are located INSIDE of the black housing with the AC condenser and the heater core. It is an extreme PIA to reach them, which is why most people bypass them. I would like to find a video of someone doing it all the "proper way" also however. I am most curious to find out if it is possible to do the job without draining the heater core or AC condenser.
@georgewing2818
@georgewing2818 2 жыл бұрын
This is the simplest method of all the ones in how to fix the AC on Ford Econoline that blows AC out the defrost. The best thing is no new parts or tubing or tank to purchase !!!
@southtexas7103
@southtexas7103 2 жыл бұрын
Didn’t explain 💩
Ford E250 air not coming out of front vents EASY FIX!!
6:57
Jeff Adams
Рет қаралды 99 М.
Ford E-350 AC stuck on DEFROST quick fix!
9:34
Daily inspirations and experiences.
Рет қаралды 440
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 18 МЛН
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 8 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 28 МЛН
Ford E-Series A/C Stuck Blowing From Defrost Most Likely Cause
6:12
Barbour's Auto Help
Рет қаралды 2,9 М.
How to Reset a Ford Blend Door Actuator
5:43
Vehicle Freak
Рет қаралды 251 М.
Ford AC Vents Stop Blowing During Acceleration.
4:43
The Limo Garage
Рет қаралды 51 М.
Ford Econoline AC Heat Defrost Acceleration Fix
10:14
New Jersey Outdoor Adventures
Рет қаралды 246 М.
E450/350 Vents stuck on Defrost. FIX
4:35
JN Lafferty
Рет қаралды 66 М.
No echa aire por las ventanillas delanteras del aire acondicionado de tu Ford Expedition ?
11:31
pablo aventuras moto blog Roussell
Рет қаралды 180 М.
Car Heater Not Blowing Warm Air | Quick Free Fix!
11:45
George Austers
Рет қаралды 1 МЛН
No Air Blowing From Your Ford Van Vents? Diagnose Blower Motors Ford E Series Vans!
6:55
1A Auto: Repair Tips & Secrets Only Mechanics Know
Рет қаралды 202 М.
Ford Van dash vent stuck on defrost
2:44
Marlboro Tire and Automotive
Рет қаралды 17 М.
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 18 МЛН