Recover gas reparing gas saveing and agsinusing recover cylinder uding
@Bass.Player5 ай бұрын
@@jollyscaria1922 WHAT?
@markfox7207 Жыл бұрын
You should recover to a cylinder not atmosphere
@ilkertokgoz2465 Жыл бұрын
Thanks for English. Good work.
@forevertechenglish Жыл бұрын
Welcome!!
@meassavuth46494 күн бұрын
Thanks for your video
@אילן-ק6ג Жыл бұрын
Thank you very much good information
@forevertechenglish Жыл бұрын
Glad it was helpful!
@mdrajibislam6786 Жыл бұрын
Why sometimes R410a refrigerant running pressure show about 190 psi.We run the unit in open space in our large space workshop? Can it be for incorrect capillary tube sizing?
@josepagan9236 Жыл бұрын
Interesting you need to take EPA Licence no recovery refrigerant and also doesn’t use micron gauge 500 micron good luck buddy.💪🏽
@WASIMEDOO9 ай бұрын
Very good job I have a similar problem on the suction side running high 360 psi for R410 and it not cooling can you give me some advice please
@forevertechenglish9 ай бұрын
Check if the compressor is okay, check the short circuit of the compressor through a multimeter. Do the needle of the gauge goes down when the compressor is started?
@forevertechenglish9 ай бұрын
Is the outdoor with capillary or expansion valve, check that as well??
@WASIMEDOO9 ай бұрын
If I close the txv right down how much turns on to open as normal
@forevertechenglish9 ай бұрын
I might think the TXV could have some problem, because I have fixed such a problem in a different air conditioner.
@forevertechenglish9 ай бұрын
or might be possible the coil is bad of the TXV?
@SolomonfsАй бұрын
If I'm using a clamp meter to check the amps, which wire should I check?
@forevertechenglishАй бұрын
You can check with live or neutral wire.
@jpenn727 Жыл бұрын
No EPA for them...
@forevertechenglish Жыл бұрын
For whom??? The EPA Is for all!!!
@salvatoregiovanni89676 ай бұрын
The EPA is only for the USA. EPA has no jurisdiction anywhere else!
@RobertTuck-vo8cw4 ай бұрын
@@forevertechenglish The EPA only applies in the US. Other countries have different agencies and laws. What country are you in?
@salvatoregiovanni89676 ай бұрын
EPA man sitting at home punching air watching this knowing it’s out of jurisdiction 😄
@lynncomstock12555 ай бұрын
3:03 Definitely NOT de minimus. Breaking the law and recording it is not smart. Of course, recovered contaminated refrigerant must be destroyed which is both inconvenient and costly.
@ald230 Жыл бұрын
Venting refrigerant into a rug. New EPA technique?
@harshalrahman994 Жыл бұрын
👍
@miangelo194610 ай бұрын
good recovery method ;(
@altafalam5746 Жыл бұрын
18JCC MODEL
@thebossnadjib6781 Жыл бұрын
Do you really have to vacuum pump the system?
@forevertechenglish Жыл бұрын
Yes it is important to vaccum the System. No air or moisture should be left inside it.
@gregrichard9192 Жыл бұрын
150 psi?
@forevertechenglish Жыл бұрын
yep
@MegaChris2997 ай бұрын
Recover 🤦♂️
@lynncomstock12555 ай бұрын
Don't do this at home.
@hisheighnessthesupremebeing2 ай бұрын
I bet this is from one of the poor countries that is screaming about climate change and how the western world has to pay reparation 😂
@forevertechenglish2 ай бұрын
Thank you for your comment. I understand the environmental concerns around refrigerants like R410A. I'll keep that in mind for future repairs and aim to follow best practices. The goal of the video was to help others with troubleshooting and repair techniques. I appreciate your feedback.
@washinton20083 ай бұрын
3rd world country nobody care guys this guy can mix 410 R 22 and 134a in the same compresor at once just to find out it won’t work properly it will dispose the Freon again and start the process again by the way the EPA man is recording that my final assumption 😂😂😂 good work though expect for the Freon leak out on “accident” 😂
@forevertechenglish3 ай бұрын
No I won't mix different refrigerants together, as I don't know what could happen doing it, it could be dangerous.