Toyota forklift no start issue . Like,Comment,Subscribe!
Пікірлер: 269
@Cantante1963 Жыл бұрын
Last comment was 7 years ago. I work driving one of this things and I’m learning a lot from your videos. Thanks.
@OscarDavila-i6e6 ай бұрын
Toyotaforkliftnoaselera
@clayton91362 ай бұрын
Last comment was one year before yours, and every year before that one.
@texasfishingandfitness26212 жыл бұрын
Ran Into a problem like this today on an 7FGU35 and I got stuck on the diag but I remembered watching this video before and remembered something similar/doing the same thing, cranking but not turning over.. except mine was missing the spark.. awesome video bro nothing but straight facts and knowledge!!!! Keep up the videos bro u help more ppl then u know or think! All the way from San antonio TX
@dustywelker40543 жыл бұрын
Thank you. I recently got a job as a forklift/maintenance position after working on the production welding/fab floor for 6 yrs. I look forward to videos like this to help me in my new position
@adriancastaneda49718 жыл бұрын
I wanted to thank you for the time you spend making these videos. I'm new to this field and your videos have really help me out. Please keep up with the great work.
@lw2nas8 жыл бұрын
Excellent! Good logical and systematic approach on Troubleshoot the problem.
@forkliftgeek108 жыл бұрын
Thanks.
@leoveroude44928 жыл бұрын
Just watched your video and I have to say thank you for a video well done! I had a no start issue with my jurassic period Allis Chalmers. I had done a lot of what you showed already, but not the brake fluid into the carb trick, that is simple but effective. In the end what I did is clean the regulator and carb inside and out very well, propane lines too. Fired right up and got rid of my stress issues too! Thank YOU!!
@StanFlahautAFD8 жыл бұрын
It was brake cleaner not brake fluid.  You have to be sure it is the flammable type too. If you use the CFC kind it doesn't work. Use starter fluid and be sure to stay away from the throttle body when you start it in case of flames from a back fire.
@mrrangemaster5 жыл бұрын
Awesome, Thanks very much for putting this on here. It makes life so much easier when it is shown the way you have just done. What a true gentlemen
@jleron224 жыл бұрын
Great troubleshooting techniques performed here 👍👍
@twotone872002886 жыл бұрын
hey buddy, thank you for sharing. I actually was working on this same lpg regulator at work the other day. The issue I had with this particular one was with the diaphragm. apparently after awhile, the oil they put into the propane to give it its smell can clog up and keep the diaphragm from working properly.
@andyfreeman6608 жыл бұрын
I work for Toyota in the UK and you would be amazed the number of times we go to duel fuel trucks switched to Gas lol.
@carlosmafla91777 жыл бұрын
Andy Freeman Haha same happened to me like two weeks ago
@andyfreeman6608 жыл бұрын
the first thing to look at before you get any tools out on a duel fuel Toyota, is the truck switched to LPG if it's switched the GAS (petrol) it will crank but not start. you would be amazed how many people get cought out on this one ( myself included)
@AndrewSmith-pp6ir6 жыл бұрын
And the switch gets bumped half way between gas and lpg sometimes which gives no start either
@samuelw.3992 Жыл бұрын
No shit. That’s a good point
@cesarvelazquez32315 жыл бұрын
Thanks i just started working for a forklift company
@mikesecondo22544 жыл бұрын
Good luck!!
@MaintenanceMan004 жыл бұрын
Awesome vid. Just graduated college with a 2 year auto degree. Want to get into the forklift repair industry. Subscribed!
@deborahchesser73753 жыл бұрын
Polish up on your schematic and wiring diagrams, the electric trucks are what you want to tech on. It’s good to know recip’s but electric trucks are way more field serviceable and usually cleaner. Good luck
@MaintenanceMan003 жыл бұрын
@@deborahchesser7375 I work for a company that services Raymond trucks and schematics and electrical in this industry I'm slowly but surely learning. Thanks for the advice. Like this industry more than cars!
@jamesmyers70663 жыл бұрын
After 35 years in this field I can give a little advice to you new guys...don’t jump off the dock and always have a 6”adjustable wrench in your pocket!
@MaintenanceMan003 жыл бұрын
@@jamesmyers7066 when it comes to "jumping off the dock" what are you referring to? Lol
@anthonykozar9172 Жыл бұрын
@@MaintenanceMan00 quite literally jumping off the dock to get down to your van!! haha
@hdkirby98233 жыл бұрын
Thank you so much for that video I had the same issue did the same thing you did and sure enough that is the problem
@JustMe-JustBecause5 жыл бұрын
Great Video! My problem was one of my morons had switched the "LP to GAS" switch. I spent a lot of time trying to troubleshoot it and when you mentioned it, BAM! fixed :)
@antoniogassmann75324 жыл бұрын
Hola amigo tenés un email, tallerautoelevadores@gmail.com Y si tenés WhatsApp Antonio Paraná Entre Ríos Argentina
@jaymatias66499 жыл бұрын
Unfortunately, price of solenoid was more than half the price of the regulator. So might as well replace the whole thing. But still up to the customer if he wants just the solenoid. In this case he opted for the regulator.
@travisjohnson27537 жыл бұрын
Thankyou! This will make me a hero at the shop!
@forkliftgeek107 жыл бұрын
+Travis Johnson when you're spraying brake cleaner into the intake always have a fire extinguisher on hand as it may backfire. Something that I should have said in the video. Thanks for watching and always be safe.
@gigglegasn207 жыл бұрын
That's a very common problem on Toyota forklifts, usually I would just put my hand on the solenoid and crank it and you will feel it if it works. If you're not getting power to that connector it's most like the relay located under the fuse box.
@GruntMoan-r7fАй бұрын
Good vid. I hope you purchased a " power probe " by now. I love that tool. a bit pricey, but a huge asset for diag. it also saves a lot of steps. - Anyway, thanks for the good vid buddy.
@bbdallas13 жыл бұрын
Great video. Thank you for sharing
@mikesecondo22544 жыл бұрын
Been a field service technician for 25 years..got 2 years left..then retirement...thank God...lift trucks are getting more complex!!!
@deborahchesser73753 жыл бұрын
I’m thinking about getting back into it, I was a Raymond tech so I’m used to reading schematics and diagrams. Not sure if the body can handle it though. Good luck on retirement brother, enjoy
@mikesecondo22543 жыл бұрын
@@deborahchesser7375 I am presently employed by a Raymond dealer as a field technician.
@THEDARK3BLUETEAMS2 жыл бұрын
Capture Troubleshoot
@richardnardella25538 ай бұрын
raymond in anchorage alaska sucks they are the worst come take the asshole who runs service out of here rob doesn’t know how to treat his customers or how to shut his mouth we won’t buy anymore raymond crap here
@marknicholson27189 ай бұрын
Did it not have gasoline in it? It's a dual fuel truck. I've Had wires break inside the insulation at terminals. Looked fine but conductor was broken.
@raulsd.i.y.videos55852 жыл бұрын
Awesome video. Good troubleshooting.
@StanFlahautAFD8 жыл бұрын
stay out of the line of fire when you start it after spraying starter in the intake. If it has jumped time a backfire will blow your doors off.
@samuelw.3992 Жыл бұрын
Definitely. I had it blow a huge fireball out once lol
@henrikjonsson43403 жыл бұрын
Thanks! Learning something new about gas-system :)
@chrisl1636 Жыл бұрын
This just come up on my for you page- it is easier to remove lp vapor hose from mixer and stick in a cup of water and crank engine, if water bubbles you have fuel as long as solenoid clicks
@antilortiz2302 Жыл бұрын
ok I see litle liquin from water came from radiator to conected to the regulator you think this is the problem and I have to refill radiator any 2 days thanks
@micheldupras78546 жыл бұрын
Hi Jay, what if the test light doesn't light up when you check the power going to the solenoid on that connector when cranking? Bad wiring?
@forkliftgeek106 жыл бұрын
Bad relay, wiring, fuse or rev switch on positive side. If this was a dual fuel check if the switch is flicked to gasoline.
@Juan-pt1lq5 жыл бұрын
Thx for the education.
@cbenpictures9 жыл бұрын
Love your process of elimination, you should consider teaching.
@forkliftgeek109 жыл бұрын
Thanks for the comment.
@joshteague89042 жыл бұрын
Did you replace the regulator or just the selenoid only? I thought just the selenoid was suspect?
@johnblack46368 жыл бұрын
Good job bro and thanks for the video;-)
@andyfreeman6608 жыл бұрын
depending on the Gas regulator type the slow run solinoid is powered from a sensor in the distributor. if you have high gas flow to the carb ( mixer) the engine will crank but not start and the main valve seal inside the regulator.
@forkliftgeek108 жыл бұрын
+Andy Freeman the type of regulator would depend on the model of the forklift. the regulator you are referring to would be more likely in an 8 series. As far as high gas flow, yes it would produce the same symptom but exhaust would smell of unburned propane and adding external fuel source would not get the engine to start.
@jacqueshenribien-aime33847 жыл бұрын
I wonder if way back I had opportunity to benefit all these training I would be an excellent Mechanic today I have to Paid to fix my vehicle for any little problem.
@theoffice18423 жыл бұрын
I sprayed starter fluid and our FL started right up. It when I checked the fuel supply the gas didn’t come out as hard as yours did. It did a little more but I had to keep opening it. Any advice?
@lukasszalbot16368 ай бұрын
I have the same problem.
@lukasszalbot16368 ай бұрын
Or similar at least
@JW-qd4ig Жыл бұрын
Hey forklift geek, Thank you for the fun interesting videos. I appreciate solid diagnostic work. And the explanation is spot on. I have a toyota 7fgcu15 with a no start, I diagnosed it to a (what I thought was a faulty shutoff solenoid) but rather a no power to the shut off solenoid issue. Do you know what else is on that circuit? It powers the solenoid through the ignition switch, but without a schematic I do not know where the solenoid connecting wires come from. Thank you
@forkliftgeek10 Жыл бұрын
kzbin.info/www/bejne/mITZgKNjr7efg7M This one is a 7 series, but not all 7 series are wired this way. Some of them, the lock off is powered by a rev switch and the input is from the distributor.
@JW-qd4ig Жыл бұрын
@forkliftgeek10 I just watched that linked video. I will definitely look into that. I bypassed the main solenoid (in the regulator) to feed it voltage so it would open. Then that is when I discovered it would run, but this video could definitely be the final culprit or at least similar to the problem that I am having. Thank you again for the explanation.
@peterlauzon49052 жыл бұрын
nice encoder bearing we saw at 11.24 !!!
@solofoto5768 жыл бұрын
Really enjoyed your video thanks.
@forkliftgeek108 жыл бұрын
+Cal Air thanks
@tinogarcia728 жыл бұрын
I did check the 2 wires and they are good
@amzilyoussef80802 ай бұрын
Hello، my forklift don't start and hydraulic system not work also i Do not have current to my starter relay and when i took wire direct from positive battery to positive relay it's start but hydraulic system don't work. Can you help me please
@WarrenStarCat4 жыл бұрын
This is good info, but we are dealing with a newer generation Regulator with dual solenoid lockouts. Getting an intemittent, NO START after the rig sits for a while. Same as yours it will try to run with starting fluid. Also breaking the flare connection coming out of the big lockout solenoid path, bleeding off some pressure and re-tightening may allow it to start. The Attending Forklift is also Puzzled by this one. S/N is 41051 Model 8FGU25. Any suggestions are helpful. Star
@forkliftgeek104 жыл бұрын
Sometimes the main solenoid (big one in the middle) gets stuck or the solenoid is already weak. When it is not starting try tapping on the solenoid and see if it starts.
@WarrenStarCat4 жыл бұрын
@@forkliftgeek10 Thanks for the info. 10-4
@WarrenStarCat4 жыл бұрын
OK Excellent. Tap on the secondary lockout on the REG when cranking and it start right up after prolonged NO START. Good Technique. Thanks. New Reg should solve this one.
@mattsan702 жыл бұрын
I'm confused - you didn't show that the solenoid was getting a good ground to operate it - just +12v on both sides of the coil. to me that suggests a relay up stream is faulty more than anything on the regulator
@forkliftgeek102 жыл бұрын
Yes I did. At 4:58 in the video, my test light is clamped to the battery positive so when it is lit from the connector it means I have a good negative. Transferring my t pin to the other side of the connector and have the test light lit verifies that my coil is not open.
@scubastevesdestiny5 жыл бұрын
Hey there. I have a tusk forklift. It is made by Komatsu. I just purchased it this morning and drove it on the trailer as well as off the trailer. While backing it off the trailer it hit the ground pretty hard and I drove it into the shop. I shut it off and it never started back up after that. The guy mentioned he cleaned the regulator to get the machine back running again. I have to assume that somehow the regulator is failing. It seems to be forcing a enormous amount of propane into the system when I turn the key key on. It acts like it wants to start but it just won't do it. Do I need to replace the entire regulator? It's blowing the excess propane out of a small vacuum size line off the side of the regulator that goes to the intake tube.
@forkliftgeek105 жыл бұрын
You could try the rebuild kit
@jesuszaragoza65548 ай бұрын
I have a 7 series with an issue that when I’m on the throttle it work but then let off the throttle it shuts off. I have spark , and propane . I do have the regulator it is full of tar . Any ideas before I replace the regulator
@forkliftgeek108 ай бұрын
Throttle plate might be gummed up
@douglasparkin1026 Жыл бұрын
Did you install a whole new regulator or just the solenoid
@jgmanza9 жыл бұрын
Thanks!!!
@antilortiz2302 Жыл бұрын
thanks for video I have question mi forklift regulator is frozen every 15 minutes and the forklift shut down after desfrozen forklift run again justo do this just when is cold once when the forklift warm up running good all day now I can running only 15 minutes thanks
@forkliftgeek10 Жыл бұрын
Check your coolant level in the radiator
@antilortiz2302 Жыл бұрын
ok I see litle liquin from water came from radiator to conected to the regulator you think this is the problem and I have to refill radiator any 2 days thanks
@Sam-lk6eo2 жыл бұрын
Hi, Buddy at the end you said you changed the regulator not the solenoid, I thought you determined the fault as being the solenoid, Or is it that in order to change the solenoid you have to do it with a new regulator and solenoid attached ?
@forkliftgeek102 жыл бұрын
Customer opted to change the regulator
@777hdt3 жыл бұрын
Solenoid will not power up on test truck until engine rotates
@fernandog.aguirre27914 жыл бұрын
Great. Thank you!
@NikoJones94 Жыл бұрын
Cool video!
@559TheAndrew2 жыл бұрын
Hey if the truck didn’t start with brake clean, what would be you next step?
@rodneyleboeuf164 Жыл бұрын
If it didn’t start with break cleaner then that would suggest a ‘no spark’ problem. Such as spark plug problem, ignition problem, coil problem.
@budiyantobong9152 жыл бұрын
Hi, how much does solenoid costs in average range?
@andycarpenter55614 жыл бұрын
@forkliftgeek I'm having a minor issue with my Mitsubishi propane forklift. Seems lately I have to stomp the gas pedal to the floor to get it to start. Could that also be the solenoid or should i look at injectors?
@forkliftgeek104 жыл бұрын
Your mitsubishi would have a different fuel system than a toyota.
@FleetTech973 жыл бұрын
Hey man I have a Toyota. I sprayed starter fluid inside and it just cranks and tries to start but never catches. It’s got spark but it looks a little weak. Could it be the distributor cap? It’s got new plugs in it. What should I look fir on the cap ?
@forkliftgeek103 жыл бұрын
Worn contacts in the cap. The cap is not the only part that produce a weak spark though. The rotor, ignition coil, ignition module, and cables are all suspect.
@221180ful4 жыл бұрын
Excelente amigo
@claythomas90509 жыл бұрын
I personally like to convert over to the Impco fuel system if the customer wants to replace the Aisan system from the factory. They run better with less problems and are cheaper to replace in the future.
@broncoblue835 жыл бұрын
Impco system will violate emissions if the forklift has an O2 sensor and will trip a check engine light. Works for a ma and pa shop but its a nogo for companies that comply with federal law lol
@rudypacheco2279 жыл бұрын
I have a cat gc18 no start, LPG i have changed the vaporizer and the lockoff, I also changed the oil pressure switch and I have 9 volts to the lockoff and no start, if I jump over voltage directly to lockoff the forklift starts and runs a few times, I also had battery checked by Napa and swapped starter with new and no fix, any ideas?
@solden496 жыл бұрын
So I have a propane floor buffer that is doing the exact same thing. It was running perfect until I dis connected the hose from the vaporizer to the carb and turned the propane valve on. I put the hose back on and now and it still will not start. I have bought a new vaporizer and solenoid and it will not start. Any ideas if that made sense?
@forkliftgeek106 жыл бұрын
+Solomon Smith when an engine does not start it can only be missing a few things, spark, fuel, air, timing and compression. I'd start with spark and fuel. Check if the solenoid is getting power.
@thatcoolguy1317 жыл бұрын
I have this model lift won't start not get power from the fuse box to starter I'm thinking the neutral safety is bad as i have checked fuses and put in new relay but can't find neutral switch. Starts and runs fine jumping to starter.
@forkliftgeek107 жыл бұрын
+thatcoolguy131 neutral switch is part of the directional lever assembly.
@sc0tte1-4167 жыл бұрын
Why replace the whole regulator if it was just the solenoid?
@forkliftgeek107 жыл бұрын
+sc0tte1 solenoid cost more than half of price of regulator. Customer opted for new one.
@joepacheco40385 жыл бұрын
Regulator diaphragm fill with oil most likely double labor replace assembly warranty is a wonderful thing
@cajememillan5800 Жыл бұрын
Can I test that plunger out side with a powerprobe?
@forkliftgeek10 Жыл бұрын
You can.
@shenchen48103 жыл бұрын
What's the reason that gas accelerator doesn't react
@carlitosreyes67034 жыл бұрын
Thank u buddy you video is nice
@garycastle14777 жыл бұрын
Great Job, I have one 5fgcu20, gets spark with key start, has good compression, cap, wires double checked, will only stumble on start, fuel is controlled by vacuum only on this one, big clue is it wont run with starting fluid in air intake. does this sould like distributor or exciter/coil, I got this job to help these guys out and got it started by jumping the relay the guy before me cut the neutral saftey switch out of the harness, so i was lost with wires dangling and off the start relay, figured most of it out without schematic, got it to start with jumper to relay, started everytime one pop, so i fixed the hydralic cylinder for side shift, installed new key switch, repaired altenator lower mount bolt broken in cover, hood hinges repaired, rewired as best i could they way it was running and now it won't start only stumbling with fuel open, Any Idea?
@forkliftgeek107 жыл бұрын
+Gary Castle pull out the hose from the regulator to the mixer. When cranking the engine there should be no gas coming out, if there is then it's flooding the engine. You could also check the butterfly on the governor, I've seen it before that when the engine vacuum increases it pulls it shut due to a broken spring. Ignition wise I usually use an ignition tester and set it to 30kv. If it's not able to jump that gap then I'd check for high resistance in the secondary circuit.
@garycastle14777 жыл бұрын
thanks for reply, good thing to look at, I checked the two units out the bottom unit looked new and shinny, had small amount of black dust inside that side, the upper had some waxy stuff but not clogging anything and the vacuum seemed to activate the switch to open valve to let LPg thru. The broken spring you mention is that in the upper or lower unit of this regulator mixer ? I have gotten spark from plug but its a very small bluish white spark that is not that strong cause the shock wasn't that bad! The plug wire 4 is bad and is getting replaced asap, but others were ok and stronger. Would that spring stop it from running on starter fluid? This is why I think its ign. THANKS FOR REPLYING. Really Appreciate it. Gary
@forkliftgeek107 жыл бұрын
Top unit u are referring to is the lock off and the bottom unit is the regulator. The mixer is on top of the intake manifold. On the mixer side (carburator) there is another butterfly which is spring loaded. Shoot me your email so I can send some diagrams.
@jturkish7 жыл бұрын
Gary Castle noon
@andyfreeman6608 жыл бұрын
nice presentation
@forkliftgeek108 жыл бұрын
+Andy Freeman tnx.
@barrygirky81947 жыл бұрын
I have a hyster 80 that wont start. I know am not getting spark. replaced the coil, distributor cap and rotor, and the boss man had me change the starter??? but I cant get spark from the coil. can you help me?
@forkliftgeek107 жыл бұрын
+Barry Girky does it have a gm engine with the bypass system?
@jaan73794 жыл бұрын
Please I don't know if you will be seeing this, I am working on a cat forklift and every time I use something combustible it start up and continue working even after I finish operating But coming the next day same story been confused for a while
@jaan73794 жыл бұрын
The forklift uses gas only
@forkliftgeek104 жыл бұрын
A no start, would always fall into 5 possible causes. Fuel, air, compression, spark and timing. In your case it would more likely be fuel related. I would start with figuring out what and how fuel is provided during cranking.
@australiaaustralia64125 жыл бұрын
Great job responsibilities are there
@sikopapouomalo96624 жыл бұрын
He don't know how to work on propane forklifts
@jasonvargas46115 жыл бұрын
I have a early 90's Clark lp forklift it wont start without a shot of starting fluid. Any ideas? Thanks
@forkliftgeek105 жыл бұрын
Well, if it keeps running after that a vacuum leak would be a good place to start. Assuming that the fuel system is vacuum operated. Poor Ignition may also be a cause.
@jasonvargas46115 жыл бұрын
@@forkliftgeek10 thanks for your reply, will check into that. Some days it fires up just fine with no help🤷♂️
@forkliftgeek109 жыл бұрын
Why only 9v? I'm assuming you have a fully charged battery. That's a big voltage drop. I'd start there.
@MAKSIVICHANE2138 жыл бұрын
ForkliftGeek workn on 8fgcu32. alternator not charging. checked 3 wires on alternator. yellow gets 12v. white with blue wire 12v but red wire nothn. fuses is good. where do red wire go?
@forkliftgeek108 жыл бұрын
+Mak Sivichane 10A IG fuse same fuse for the charge indicator light
@checkenginelover6 жыл бұрын
Great vid.
@NurAhmad-h8sАй бұрын
I Just washing my forklift and it cant running right now, anyone hve solution for me?
@tangkokaun43834 жыл бұрын
Sir my is toyota diesel engine 6 sparks also cannot start how to do
@boater354 жыл бұрын
I’m desperate for help. I recently purchase a Toyota 42-4FGC25 lpg forklift. I purchased it at an auction and it ran perfectly fine. I transported it my shop and I can’t get it to start. It has spark. The forklift was at sea level and I’m now at 4700’ elevation. I’m assuming I have a fuel mixture problem. I tried messing with the screw on the top of the regulator and I can get it to where it almost starts but can’t get continuous combustion. I’m unfamiliar with lpg fuel systems. Any help would be greatly appreciated. I purchased a new battery so it should have plenty of voltage. Thank you.
@forkliftgeek104 жыл бұрын
How far does the spark jump? Lpg is a gas and requires higher kv to ignite. Is the lpg lock off vacuum operated or solenoid controlled?
@boater354 жыл бұрын
It’s vacuum operated. Tester shows spark but I doubt the spark is the problem. It ran fine at sea level and when I brought it to the shop later the same day @ 4700’ elevation I can’t get it to start.Is there a way to send you video?
@forkliftgeek104 жыл бұрын
Ok, if its fuel try spraying carb cleaner or brake cleaner into the intake, see if it starts. There could also be too much fuel flooding the engine.
@boater354 жыл бұрын
I got it running. It was a fuel problem. Had not leaned out the regulator enough. Thank you very much for replying. It’s extremely appreciated.
@tinogarcia728 жыл бұрын
ok that's what it said she on the wiring diagram and didn't know where the engine rev sw was located so I need to replace the distributor or can I just replace the engine rev sw is there any picture of it thank you
@forkliftgeek108 жыл бұрын
+agustin tirado I would suggest checking the integrity of the wiring first.
@tinogarcia728 жыл бұрын
i did check everything and still wont start
@forkliftgeek108 жыл бұрын
+agustin tirado are you sure fuel is what you are missing?
@tinogarcia728 жыл бұрын
any other idea
@kenzieneal84763 жыл бұрын
Excellent
@tinogarcia728 жыл бұрын
i have this problem engine starts and then dies check the regulator valve relay and is not working theres no ground to the relay to activated the relay and the solenoid on the regulator where this ground supply from
@forkliftgeek108 жыл бұрын
+agustin tirado if you're talking about the lock off solenoid then ground could either be provided by the ecm or constantly from the chassis.
@maxwelmurtala40443 жыл бұрын
This is very interesting
@hawgbilly_07born_assassin887 жыл бұрын
very helps man
@tinogarcia728 жыл бұрын
yes the lock out solenoid relay that supplys power to the lock solenoit theres no grount to the relay to ctivate the lock out solenid i replace the ecm and still the same problem
@forkliftgeek108 жыл бұрын
+agustin tirado is this a toyota?
@frankstromboili54828 жыл бұрын
I have a 7FGCU20 that won't start when hot unless you relieve fuel pressure from line. any ideas?
@forkliftgeek108 жыл бұрын
+Frank Stromboili when it's not starting pull the hose form the regulator going to the mixer. If you feel any pressure when cranking the engine then your regulator is faulty.
@billjarred75315 жыл бұрын
I'm a Toyota tech. Its most likely the regulator. They seem to have a service life of about 7 years in my experience. Once they need adjustment its soon time for replacement on the 7-series trucks in my experience.
@ellie95717 жыл бұрын
hi i have a problem with tcm 3.0 ton diesel forklift.(i think 1992).key ignition turns on but no start.It starts if i use screwdriver on starter first time.What is wrong?Starter is fine.had it checked.
@forkliftgeek107 жыл бұрын
+crazy pineapple where did you use the screwdriver on?
@forkliftgeek107 жыл бұрын
+crazy pineapple im guessing you jumped the battery connection on the starter to the starter solenoid with a screwdriver. If this is the case then everything from the key switch, relay, and wiring upto the starter are suspect. Corrosion in the connectors is also a possibility.
@honi98 жыл бұрын
wondering if you can help? I have a forklift which is a Henley husky 12 which has a ford 4cyl 2711e convert with a beam 120a propane system. The problem I have is that the forklift runs fine when shescold and just been fired up, though when she gets hot after say 10mins she begins to struggle to rev properly like she is struggling to get fuel. you can put full throttle and she just sits all lumpy at idle revs struggling to do anything. then out of the blue she will pull through and rev normal for a few secs and then die off again. if I let her cool down for 15mins she will fire up again as normal until she gets warm and then do the same thing again. bare in mind shes an old girl so the engine runs a little hot anyway so im wondering if its too much heat causing this as the regulator we have the beam 120a is so hot that you can barely touch it... Im wondering what you can advise?
@forkliftgeek108 жыл бұрын
+honi9 when it's acting up you could try what I did here and spray some carb cleaner or brake clean into the intake and see it runs any better, if it does then you are probably right that it's lacking fuel. Be careful though in using an external fuel source as it might backfire and if you sprayed too much into the intake it might catch fire.
@forkliftgeek108 жыл бұрын
+honi9 does the regulator have a primer button? Sorry not familiar with beam regulators.
@honi98 жыл бұрын
ForkliftGeek why is it only doing this when the thing warms up after 10mins running though. plus why is the regulator/mixer (beam120a) so bloody hot to touch?surely the coolant feed into themixer shouldn't heat it that much? could that be the problem? is it getting so hot the diaphragm is going all to shit with the heat. then when its cool the diaphragm is fine again? this is about the level of my grasp on the situation...
@forkliftgeek108 жыл бұрын
+honi9 what does your temperature gauge indicate when it starts acting up?
@honi98 жыл бұрын
i will check next time ok
@jesiedoromal90475 жыл бұрын
Good day Sir, about the positive side of that solenoid,,why is it blinking when cranking, is it the engine timing? What if theres nothing on positive side,what some alternative ways to test or check? Salamat po:
@forkliftgeek105 жыл бұрын
The blinking is the voltage fluctuation from the battery. Whenever a load is applied to the battery(in this case the starter) the voltage drops. If there is no positive supply you could do a bypass test and provide your own 12v supply.
@jesiedoromal90475 жыл бұрын
@@forkliftgeek10 havent encounter this problem,mostly here poh issue sa LPG regulator but some wiring issue not yet ,soon if this problem exists i know what to do, still developing some diagnostic techniques , cge sir salamat sa info God Bless
@adamadam-mq6im6 жыл бұрын
hi any idea where to buy toyota forklift diagnostic software ?
@forkliftgeek106 жыл бұрын
Intella sells the 8 series analyzer
@chax20042 жыл бұрын
You mean that Snap on doesnt make a $175.00 solenoid tapping tool and you had to use a wrench. 😄😄
@robe50009 жыл бұрын
Had to install a completely new reg for a bad solenoid!? Dam
@johnlangdon57848 жыл бұрын
+Robert Perry Ah ha! Thank you! I was getting confused by the term regulator when it was the lockoff that was the problem. *click* The lockoff is in the regulator on this machine.
@tinogarcia728 жыл бұрын
Yes what happens is that engine starts then dies right of way won't stay running the rally that activate the fuel cut off valve won't stay on if I by pass it it will run bud on lean mode
@forkliftgeek108 жыл бұрын
+agustin tirado what do you mean when you said lean mode?
@tinogarcia728 жыл бұрын
can you pm me at tinotirado@yahoo.com
@Jokestbh7 ай бұрын
he made things so confusing lol simpley you have 2 wire one constant feed other wire feed. put tst light to mainly allways the stripped wire and crank to see if you have hower when cranking. other wire should show live all the time. also buy a power proe so much easyer........
@delbyshernandez.insurance8 жыл бұрын
Hello Sir I have a problem with toyota 8FGU25. The engine fail and the aceleration is up nd down every time, I can see two error code E-03-1 and E-01-3, Please help me to solve this problem.
@forkliftgeek108 жыл бұрын
E03-1 is an intake pipe pressure sensor open. Check your connections on the map sensor. E01-3 is a rich condition. Go with the E03-1 first. Check also for a vacuum leak.
@kb1sxv5 ай бұрын
The engine has to rotate fort the solniod to pull in
@tobybrewer24395 жыл бұрын
Got a s50ft no fuel new regulator getting fuel to the solenoid but not past would that be the problem
@forkliftgeek105 жыл бұрын
Make sure the solenoid is getting power and ground
@tobybrewer24395 жыл бұрын
You the man broken ground wire thanx so much
@SergioCruz-ji3jy8 жыл бұрын
I'm having the same problem but with a Nissan it cranks but won't start any ideas what it could be?
@forkliftgeek108 жыл бұрын
If it cranks with normal speed then one or more of the following would be missing. Spark, fuel, compression, air (being sucked in). If all of these are present then it would be timing( ignition or cam/crank).
@MrSfbsnyder6 жыл бұрын
if you have spark and no error codes, lp regulator is over pressurizing
@ayerimosfox5 жыл бұрын
Will this solution also work for a conversion kit for automobile use?
@forkliftgeek105 жыл бұрын
As far as testing if you are having a fuel problem, yes.
@danieloriaku66244 жыл бұрын
I suppose so, since it's all based on the same principle.
@albertososa57913 жыл бұрын
What about when you have changed the entire regulator but the forklift wont start
@forkliftgeek103 жыл бұрын
Cranking no starts would have 5 possible causes fuel, air, compression, timing and spark. If it was fuel related, it either is lacking in fuel ir in excess. The regulator is only one part if the system. The mixer is also a possible cause and injectors(if it is equipped).
@albertososa57913 жыл бұрын
@@forkliftgeek10 ok but we spray starter fluid on the air filter are and it starts no problem but when we turn it of and try to start it up again it won't we have to spray it again to start it
@forkliftgeek103 жыл бұрын
Then I would suspect a vacuum leak. Other possibility would be a broken hose from the regulator to mixer or mixer to lock off.
@efraindlcerda28605 жыл бұрын
Where can i go to school to learn forklift repair?
@forkliftgeek105 жыл бұрын
If you are in Canada, you need to be employed as an apprentice first before being accepted into school. Don't know about other countries though.
@busfairnitrometh6 жыл бұрын
Im working on a 8series Toyota forklift with a code e 09-1 and will not start. Any ideas
@forkliftgeek106 жыл бұрын
+busfairnitrometh 09-1 is ignition signal abnormality. No spark?
@joepacheco40385 жыл бұрын
Broken wire tach sensor
@1176hambone2 жыл бұрын
All of that just to find out that the whole damn regulator needs replacing? No shit.