GAS FURNACE MOTOR DRAWING HIGH AMPS TROUBLE SHOOTING TO FIND ISSUE

  Рет қаралды 20,211

steven lavimoniere

steven lavimoniere

Күн бұрын

Пікірлер: 113
@tedparkman3111
@tedparkman3111 Жыл бұрын
For a plumber, your a danm good electrian Steve. Awesome job!
@bradleythomas5445
@bradleythomas5445 Жыл бұрын
That was a tough one. Great detective work, Steve.
@PSB-900
@PSB-900 Жыл бұрын
You're brilliant Steve! Great troubleshooting work.
@J-Colt
@J-Colt Жыл бұрын
Nice trouble shooting Steven! Thanks for posting!
@josephcade3541
@josephcade3541 Жыл бұрын
Steve you should ohm out the windings and ground on the motor. That would tell you straight away if the motor is bad. And if it's bad when you get a new motor you should ohm out the windings to be sure that the new motor is okay. And be sure to put the amp meter on it make sure the proper amperage
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
Excellent diagnosis Steve!
@JavierGalvan-s2f
@JavierGalvan-s2f Жыл бұрын
That looked complicated Steve, great job determining what wire to which, that's why I learn SO much from your video's! Enjoy the long weekend and don't forget the video's! 🎉😎💥💯☝️👍🫵
@josephcade3541
@josephcade3541 Жыл бұрын
Steve make sure you check the capacitor for good health. If a run capacitor fails, the motor can display a variety of problems including not starting, overheating, and vibrating
@FemboyEngineer
@FemboyEngineer Жыл бұрын
Lack of phase shift
@Todestelzer
@Todestelzer 3 ай бұрын
He checked it. It’s in the vid.
@Daleeather1975
@Daleeather1975 Жыл бұрын
Hello Steve Great job troubleshooting 🤩👍
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd Жыл бұрын
Well done Steve. Every now and then, you'll get that long one.
@WeatherNut27
@WeatherNut27 Жыл бұрын
Troubleshooting from hell. I watched every minute. Nice job explaining your thoughts and reasons for things.
@josephz9006
@josephz9006 8 ай бұрын
Wow this is a perfect example of why i do all my own Plumbing electrical and and anything in-between
@MikeMcCue849
@MikeMcCue849 Жыл бұрын
GREAT VIDEO STEVE, VERY INFORMATIVE
@trackman515
@trackman515 Жыл бұрын
In the old days I use to ohm the windings.
@PianoRevisited
@PianoRevisited Жыл бұрын
When Steve says "that's queer " - we got problems, Mama ! Between old Nervous Nellie and this Daycare - that's a full time job. 😅
@craigs3183
@craigs3183 Жыл бұрын
Cluster F pain in the A . Good call getting the electrician to check out the main wiring.
@zackmax7184
@zackmax7184 Жыл бұрын
36 Amps is a lot unless that is a Heavy Duty Light Switch. I think a normal light Switch is for about 15 or 20 amps.
@DEW409
@DEW409 Жыл бұрын
Looks like you are energizing two speeds at once, which will burn out the motor. The fan really is spdt, and should send power to either the bonnet fan control or directly the blower high terminal for ac. That way you can turn on fan from the thermostat when heat is on without destroying the motor. Of course what you did will work, since you are just using one speed.
@stevenlavimoniere
@stevenlavimoniere Жыл бұрын
problem is there is 2 seperate tsats for this unit .. that is going to be adressed next . it should have one . been wired like this for 30 years
@JamesAgans
@JamesAgans Ай бұрын
Wow, great tip, thank you!
@JamesAgans
@JamesAgans Ай бұрын
​​@@stevenlavimoniereHi Steve, I missed your banter with Miss Moly on this one. I recently lost my little girl Aussie- Doodle MaKenzie. I live alone like you and I miss her badly. Its amazing how much they mean to you, and how much you miss them when they are gone. 😢Thanks for all the education you provide.
@1022hard
@1022hard Жыл бұрын
Great job Always Steve!
@TomLawson05
@TomLawson05 Жыл бұрын
Steve that was a real head scratcher good job thanks for the video
@dannyg1809
@dannyg1809 Жыл бұрын
25 minutes in and I’m pulling my hair out 😂 I’d give it a good kick and hope for the best! Your amazing Steve!
@JamesAgans
@JamesAgans Ай бұрын
The blower DRIVE BELT on the FHA furnace my dad had installed in 1948 lasted 35 years until 1983. The motor nor anything else on that furnace ever did fail, but the furnace was replaced to provide central air conditioning in the 90's. The heat exchanger on that original furnace was cast iron. When I hear HVAC people calling 10 year old systems as needing replacement, it shows me how people in this country have been willing to accept cheap, not fit for purpose Chinese crap for way too long.
@frankchandler8005
@frankchandler8005 Жыл бұрын
I SEE MISS MOLLY AT THE HELM IN THE TRUCK. STEVE DO YOU BUY YOUR PARTS IN BULK ON LINE OR DO YOU GO TO THE SUPPLY HOUSE.
@kevindean2016
@kevindean2016 Жыл бұрын
The black is common the red is normally open and brown is normally closed so when the relay is energized you will get power to the red wire
@eddymumford4086
@eddymumford4086 10 ай бұрын
getter done 👍👍
@deanguando1335
@deanguando1335 Жыл бұрын
The wiring is really jammed into that small box.
@MrMultitool
@MrMultitool Жыл бұрын
Great job
@electrickal1
@electrickal1 Жыл бұрын
That had the potential to cause a house fire!! An RCD or (GFI in north America) would have prevented a lot of those issues including allowing you to jumper the neutral to ground. I'm an electrical tech in a UK hospital and bypassing safety switches is a serious no no, they are there for good reason and should never be removed, bypassed or cheated. Death, fire or injury caused by those actions can be traced back and litigation taken against the person who modified the machine from it's design criteria, absolving the manufacturer of all blame. Be careful what you are doing.
@DwayneBaker-r2z
@DwayneBaker-r2z Жыл бұрын
Steve,there is a squirrel in the cage MAMA
@tim5158
@tim5158 Жыл бұрын
One to many hands working on that equipment , hopefully you got it.
@fanofoldfans9238
@fanofoldfans9238 Жыл бұрын
Steve, That was a great troubleshooting skills. 35 amps! Almost as if the motor was getting 240VAC instead of 120? That time/ temp limit switch is fried allowing power to the low speed and high speed windings... Great job
@electrickal1
@electrickal1 Жыл бұрын
Ohms law stipulates that voltage and current are inversely proportional to each other, so doubling the voltage would halve the current.
@fanofoldfans9238
@fanofoldfans9238 Жыл бұрын
Doubling the voltage would double the current! And because it's an inductive load it would more than double. @@electrickal1
@electrickal1
@electrickal1 Жыл бұрын
Apologies, you are correct. V=I times R and the power would quadruple because it's P=I squared R.@@fanofoldfans9238
@JamesAgans
@JamesAgans 2 ай бұрын
I really feel for you service guys with all the Chinesium parts coming onto the country.
@vic5979
@vic5979 Жыл бұрын
Now that’s what I call rocket science!!
@KW86.
@KW86. 6 ай бұрын
Awesome video. How many of us repair guys has balls to call electrician, we want to tare house down some of us
@TheAnalystradioprogram
@TheAnalystradioprogram Жыл бұрын
Steve why don’t you have some kind of rig where it’s a plug with the other end spliced and you just hook up to the motor with the 120 direct to see if it spins? Then you don’t have to remove it to test.
@kentbassler5037
@kentbassler5037 Жыл бұрын
Steve I didn't see you connect the motor shaft to the blower wheel ?
@stevenlavimoniere
@stevenlavimoniere Жыл бұрын
i did just trying to keep the video as short as possable
@stevebrickley3295
@stevebrickley3295 Жыл бұрын
“I should have one of them in the truck.”
@picklerix6162
@picklerix6162 Жыл бұрын
Steve has a parts store on wheels. I never carried as many capacitors as he does and he carries some of the most obscure toilet parts that I have never heard of before.
@dexenationgracey1979
@dexenationgracey1979 Жыл бұрын
​@picklerix6162 You could make up a part that doesn't exist, and Steve somehow has it in the truck.
@sherwinalvarez7365
@sherwinalvarez7365 Жыл бұрын
​@dexenationgracey1979 😂Thats a fact.
@papaleos9360
@papaleos9360 9 ай бұрын
Imagine the hundreds of hours of drive time he has avoided over the years by having so many parts on the truck.
@rodneyskinner7741
@rodneyskinner7741 Жыл бұрын
Hello Steve!
@Mark.R_
@Mark.R_ Жыл бұрын
Signwriting on the new truck.
@BobSmith-mj7ik
@BobSmith-mj7ik Жыл бұрын
Good diagnostic skills. Anyone else would have just thrown a motor in it and walked away.
@richardsciranko3004
@richardsciranko3004 Жыл бұрын
Well didn't he do that with the first motor?
@SeersantLoom
@SeersantLoom Жыл бұрын
Good idea to check current draw after motor replacement. I've seen at least couple of HVAC channel guys doing it regularly, just for assessing system health. They double check all the voltages and amps on all phases, compressors, fans, measure voltage differences on relays etc.
@adamdavies163
@adamdavies163 Жыл бұрын
Job satisfaction eh Steve? Always great to fix an awkward one.
@kevindean2016
@kevindean2016 Жыл бұрын
Check the voltage with it running..................that will tell the story'
@Joseph-jx8bl
@Joseph-jx8bl Жыл бұрын
I think a couple of my wires fried watching this post…….so it was basically getting double the juice and it cooked the motor etc?
@iamnoone.
@iamnoone. Жыл бұрын
Howdy Steve and Molly
@robertwojtowicz933
@robertwojtowicz933 Жыл бұрын
Good video, Steve 👍
@kaib1125
@kaib1125 Жыл бұрын
this thing just missed you it wanted your attention again :D
@ntsecrets
@ntsecrets Жыл бұрын
Wow I wonder if all the issues in the past were due to that cycle switch?
@jblyon2
@jblyon2 Жыл бұрын
It's possible. I seem to remember at least another video where someone had a furnace that was repeatedly acting up and a very similar looking cycle switch was the issue.
@memyselfandifarmer
@memyselfandifarmer Жыл бұрын
Two power points going to the motor.
@Altmechanic
@Altmechanic Жыл бұрын
The electrical always get most of the guys. Steve knows his shit, not easy mama.
@tonym6920
@tonym6920 Жыл бұрын
Hey Steve and Miss Molly! Workin’ again y’all. 👍👍. Miss Molly keeping an eye on Steve while working, lol
@bruce8572
@bruce8572 Жыл бұрын
I've seen that happen when it tries to run with 2 of the speeds are wired together..
@porky7753
@porky7753 Жыл бұрын
Steven, it's Labor Day weekend. Pick up a T-bone steak for Luna. lol
@alnonymous9361
@alnonymous9361 Жыл бұрын
Energizing multiple speed taps will burn out a motor quick fast in a hurry. The fan cycle switch with limit is only supposed to energize the motor through the normally closed contact on the relay which will disconnect when cooling is calling, therefore it would be impossible to energize multiple speed taps at the same time unless it was miswired. NO! Don’t use ground as a neutral! Don’t trust fieldpiece. Do not bypass safeties, do not bypass door switch, that’s shake hands with danger. Usually you don’t want heating fan speed & cooling fan speed to be the same speed. Too low fan speed in cooling may freeze the evaporator, too high may not dehumidify enough causing mold & mildew. Too low fan speed in heating will overheat, too high in heating will cause condensation in the primary heat exchanger & quickly rust the heat exchanger making carbon monoxide potentially harming occupants.
@JamesAgans
@JamesAgans Ай бұрын
Very GOOD information, thank you! 😊
@josephcade3541
@josephcade3541 Жыл бұрын
That capacitor keeps the motor healthy otherwise it overheats and so does the wires
@billderby1527
@billderby1527 Жыл бұрын
Hard to tell because of your tape and camera didn't show clearly but I suspect you have wired up black from the motor to the 120v hot. This black wire from the motor is high speed. You then wired up the red wire from the motor to 120v from relay. This red wire is a lower speed. Attempting to run both high and low speed at same time is not good. The motor is off on internal overload. if you ever feel a motor and it's hot, cool it off before condemning . What we do know for sure is it is not the power switch as you have 120v to furnace. You always have to have panel on when checking amp draws otherwise the lack of static causes motor to draw over amps. Try just wiring up only white and black wire from motor of course the cap needs to be wired to. Then put on door and check amps.
@priyajakatdar3759
@priyajakatdar3759 2 ай бұрын
Why replace the relay, bypass the door switch & try to fix a working connector without checking basic wiring? Perhaps I didn't get the point of the video.
@gordonpotts753
@gordonpotts753 Жыл бұрын
Molly in the background. Lol.
@Bob.W.
@Bob.W. Жыл бұрын
Hello all.
@zunar_j5_933
@zunar_j5_933 Жыл бұрын
What a cluster F. Well done tho!
@bashirmohamed7982
@bashirmohamed7982 11 ай бұрын
I would have tried switching the red to different color going to motor, see if it runs
@donhorn548
@donhorn548 Жыл бұрын
Good trouble shooting.
@zackmax7184
@zackmax7184 Жыл бұрын
Might have had a Fluffy Chewing on the wires.
@deanerbes5725
@deanerbes5725 9 ай бұрын
That's the problem with using 2 speeds and those old limits.
@jeffreywhitlatch1409
@jeffreywhitlatch1409 Жыл бұрын
A day in the life and the f'd up stuff you run into out there. It sucks frying a motor because of a bad fan control that probably fried the motor before it. Straight cool t-stat with heat and omit fan control. If enough wires and a 24volt gas valve, heat anticipator in it. Good YOB.
@williegillie5712
@williegillie5712 Жыл бұрын
Should of ran lol. Good sense of humor. But hey I knew you’d find the faulty furnace fan.
@josephbradshaw5353
@josephbradshaw5353 Жыл бұрын
Most techs nowadays can’t do what you just did
@overwatch2671
@overwatch2671 Жыл бұрын
Its a pile of rudd, steve
@zackmax7184
@zackmax7184 Жыл бұрын
Sounds like a Leaka Momma.
@zackmax7184
@zackmax7184 Жыл бұрын
Get Your Tablet out and Sell Them a New System. Lol
@FemboyEngineer
@FemboyEngineer Жыл бұрын
3:56 horrific wiring
@cndream1
@cndream1 Жыл бұрын
Does the primary problem start with there being 2 thermostats . Too much monkey motion and gizmos to make it all work ??????? Why would you even have 2 thermostats any way ?????
@vic5979
@vic5979 Жыл бұрын
Brain surgery at its best! You rock!!
@KeepingitAnalog
@KeepingitAnalog Жыл бұрын
Great video Steve! That machine is defiantly a little queer.
@craigharding475
@craigharding475 Жыл бұрын
I wonder who monkeyed with that unit?
@J-Colt
@J-Colt Жыл бұрын
Screw it, I'm first not edited either mama!
@tedbell4416
@tedbell4416 Жыл бұрын
Nope beat you by ten minutes
@Deion245
@Deion245 Жыл бұрын
@@tedbell4416 cap
@tedbell4416
@tedbell4416 Жыл бұрын
​@@Deion245zap
@dannyharron1318
@dannyharron1318 Жыл бұрын
motor running on 2 speeds
@mikehouser5430
@mikehouser5430 Жыл бұрын
Warranty?
@markpowell1031
@markpowell1031 Жыл бұрын
First comment yippee
@eddymumford4086
@eddymumford4086 10 ай бұрын
what a mess
@dannyg1809
@dannyg1809 Жыл бұрын
So I say this with the utmost sarcasm, I thought you were a licensed plumber not a licensed electrician 😅 So your telling me, one teacher could walk by and turn on AC unit, another teacher could get cold and walk by and turn on heat? Unbelievable 😅
@gregdemars2751
@gregdemars2751 Жыл бұрын
Hello You need 240 voltage run the replacement the motor good luck Bee safe
@tedbell4416
@tedbell4416 Жыл бұрын
240 241 whatever it takes
@stevenlavimoniere
@stevenlavimoniere Жыл бұрын
its a 110 motor,,, most gas furnaces have 110 motors
@dong4617
@dong4617 Жыл бұрын
I don't think a 240 motor would work without L1 and L2.
@gregdemars2751
@gregdemars2751 Жыл бұрын
@stevenlavimoniere Steve Sorry for my confusion you're Wright 110volt
@Deion245
@Deion245 Жыл бұрын
First
@tedbell4416
@tedbell4416 Жыл бұрын
Nope
@Deion245
@Deion245 Жыл бұрын
@@tedbell4416 yup
@J-Colt
@J-Colt Жыл бұрын
@@Deion245 Tedbell4416 got ya by 20 easy
@tedbell4416
@tedbell4416 Жыл бұрын
​@@J-Coltgot ya by 40 keep practicing though
@J-Colt
@J-Colt Жыл бұрын
@@tedbell4416 You da man Ted!
@frankrizzo3915
@frankrizzo3915 Жыл бұрын
Hello Steve!
CERTRAL AC NOT WORKING IN COMMERCIAL BUILDING HAD TO BAIL OUT ELECTRION AGAIN
49:04
GAS FURNACE WILL NOT RUN OTHER GUY GAVE UP
40:07
steven lavimoniere
Рет қаралды 149 М.
1, 2, 3, 4, 5, 6, 7, 8, 9 🙈⚽️
00:46
Celine Dept
Рет қаралды 111 МЛН
When Cucumbers Meet PVC Pipe The Results Are Wild! 🤭
00:44
Crafty Buddy
Рет қаралды 57 МЛН
A.C. HACK JOB ' NEW SYSTEM ' NEVER COOLED MANY ISSUES FIXED
41:03
steven lavimoniere
Рет қаралды 83 М.
MYSTERY NOISE FROM HOT WATER SYSTEM
50:34
steven lavimoniere
Рет қаралды 105 М.
GAS FURNACE HAS NOT RUN IN A MONTH
37:32
steven lavimoniere
Рет қаралды 53 М.
GAS FURNACE WITH ISSUES REPAIRED
44:30
steven lavimoniere
Рет қаралды 20 М.
OLD GAS FURNACE NOT HEATING HOUSE A FEW ISSUES FOUND AND FIXED
41:15
steven lavimoniere
Рет қаралды 61 М.
Old TRANE Gas Furnace repair
36:31
Anti DIY HVAC
Рет қаралды 22 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 43 М.
AC FAN RUNNING WEARD AND NOT COOLING
35:46
steven lavimoniere
Рет қаралды 23 М.