General Maintenance for Generac Generator, Schedule A & B

  Рет қаралды 15,576

Jerry Jackson DIY

Jerry Jackson DIY

Жыл бұрын

Generators usually require maintenance. In today's video we do a Schedule A & B Generac maintenance: changed oil, put a new oil filer on, changed spark plugs, and air filter, in addition, we check the battery voltage to make sure the battery is healthy for the new year ahead. Be sure to check with your owner's manual on which produces to purchase. This is the kit we purchased for our generator.
Amazon:
Generac 0J93230SSM 20Kw-22Kw SM 999 Maintenance Kit
amzn.to/3mFsTWP
LEXIVON 5/8" Swivel Magnetic Spark Plug Socket, 3/8" Drive x 6" Total Length
amzn.to/41J8ezX
GEARWRENCH 3/8" Drive 84 Tooth Long Handle Teardrop Ratchet
amzn.to/3L8Fs5d
Klein Tools MM400 Multimeter
amzn.to/3GVp1aP
Host, Jerry Jackson
Camera and Editor, Tina Jackson
Music Funkorama by Kevin MacLeod
Link: incompetech.filmmusic.io/song...
License: creativecommons.org/licenses/b…
Be sure to like, subscribe and share.
And remember folks, “If you put your mind to it, you can do anything. See yah.”

Пікірлер: 18
@donaldwbarkey7458
@donaldwbarkey7458 Ай бұрын
Thanks for sharing! Looks easy when you are doing it!
@JerryJacksonDIY
@JerryJacksonDIY Ай бұрын
Thanks for the comment. Appreciate it. Thanks for watching.
@ArtistDavidU7ub3
@ArtistDavidU7ub3 4 ай бұрын
Nice video and instruction. Thanks.
@JerryJacksonDIY
@JerryJacksonDIY 4 ай бұрын
Glad it was helpful! Thanks for the comment.
@JerryJacksonDIY
@JerryJacksonDIY 4 ай бұрын
Hey David... thanks for the comment... Thanks for watching....
@A181218121812
@A181218121812 5 ай бұрын
Great video. Lots of helpful information. I think that you should also test the battery with the charger circuit turned off after you tested the battery with the charger circuit on (which proved that it is being charged properly). A battery analyzer would be the best for that. You don't want to find out the battery went bad when you need the generator during a power outage. I like the Midtronics PBT-200 battery tester or the Midtronics PBT-300 if you need to test higher amperage batteries.
@JerryJacksonDIY
@JerryJacksonDIY 5 ай бұрын
Great tip. Thanks for the comment.
@LivingTheDream21
@LivingTheDream21 Күн бұрын
What's the difference between Service A and B? Doing the spark plugs as well? Great video by the way!
@stevehorvat69
@stevehorvat69 5 ай бұрын
I have the 18kw version and just did my first oil change this weekend after 2 years. I’m at 25 hours of runtime with 8 outages over the last two years. Longest outage was 11 hours. Trying to figure out why your old oil looks so orange (almost rusty). My oil was just your typical dirty black. Thanks for the video.
@JerryJacksonDIY
@JerryJacksonDIY 5 ай бұрын
Hey Steve. Thanks for watching. I chalk it up to the type of oil I’m using and the environment that my generator lives in. I’m in a northern state and my generator is always in the shade. Looks the same rack year when I change it and have no issues with my generator. Thanks again.
@kwd57
@kwd57 Жыл бұрын
At 11 min. 41 sec. you said it takes 2 and 3/4 of a quart. I know you meant to say 1 3/4. Just thought you should know. Thanks for the video.
@JerryJacksonDIY
@JerryJacksonDIY Жыл бұрын
Yup, I meant to day 1 3/4 quart... Thanks for he comment and thanks for watching...
@hermanbruns7526
@hermanbruns7526 7 ай бұрын
I’ve got a new 24Kw Generac that has run for 5 minutes a week for 2 years….meaning I have less than 10 hours of total run time. Changed oil, filters, and plugs….all easy The question I have is why do a valve clearance check since it’s no where near the 25 hour recommendation Thoughts?
@JerryJacksonDIY
@JerryJacksonDIY 7 ай бұрын
Great question Herman... I feel that the owners manual assumes that there will be some outage time usage along with the normal weekly cycle time. But if you are comfortable and have kept track of the amount of run time you generator has then waiting till the 25 hour mark would make sense to me.
@Glockcoma1
@Glockcoma1 18 күн бұрын
I have the mobile app with battery voltage included. Any opinions on it's accuracy? I've had my 22 kw 2 years now with 8 hours of run time only in exercise mode. I can handle everything but valve adjustment. Thanks for the detailed video. The dealers want stupid money to do this stuff.
@JerryJacksonDIY
@JerryJacksonDIY 13 күн бұрын
I know right. It is crazy what they want to perform some of this stuff. I would say the app is fairly accurate. Thanks for watching.
@CPVet55
@CPVet55 6 ай бұрын
I have a 24kw Generac. One year old. It says schedule an every two years. We’re in Florida so maybe not as much use a you. Are you doing it yearly just as an extra precaution? Great video.
@JerryJacksonDIY
@JerryJacksonDIY 6 ай бұрын
Thanks for sharing. Yes. I do it yearly more for precaution and we experience more use. Thanks for the comment.
How to Clear a Red light on a Generac Generator - The Generator Guys
4:56
The Generator Guys
Рет қаралды 124 М.
Получилось у Вики?😂 #хабибка
00:14
ХАБИБ
Рет қаралды 6 МЛН
Homemade Professional Spy Trick To Unlock A Phone 🔍
00:55
Crafty Champions
Рет қаралды 59 МЛН
How To Perform Annual Schedule A Maintenance Generac 20kw Automatic Whole House Standby Generator
10:56
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 31 М.
Generac Maintenance
12:20
Jordan's Everyday DIY
Рет қаралды 80 М.
Generac Battery Service  Inspect Battery maintenance interval reached
17:06
15 Steps to Maintain Your Generac Guardian Generator
7:51
Pullin Electric
Рет қаралды 163 М.
Generac Annual Maintenance
14:01
Matthew Menke
Рет қаралды 18 М.
Whole-Home Generators: Peace of Mind or Financial Liability?
13:04
Electric Pro Academy
Рет қаралды 56 М.
Triphasic Infinite Energy Generator 10Kw 230V - Liberty Engine 1.1
17:33
The Liberty Engine Project
Рет қаралды 1,1 МЛН
Ты что-то понял?  #automobile #shorts #ваз
1:00
Мышка Мэвис
Рет қаралды 1,1 МЛН
ВОТ ОНА, ЛЮБОВЬ АВТОМОБИЛИСТОВ
0:39
Аквариум
Рет қаралды 182 М.