Generator and Automatic Transfer Switch Installation!

  Рет қаралды 60,714

Axiom Balkan Travel

Axiom Balkan Travel

4 жыл бұрын

in this video we installed 5 KW electric generator and Automatic Transfer Switch for entire house...
it is Powermate PMD 5000s AVR generator and dedicated ATS.
in this video i used background music : no contract - name of the child

Пікірлер: 75
@DartaineanBansavi
@DartaineanBansavi Ай бұрын
Hi thank you I really like your video,I'm also loving doing electrical work n I'm working as and TA for also 2 years now..
@powergemelectrical
@powergemelectrical Жыл бұрын
As a uk Electrician & seeing all the spiral twists in those wires when you put them in trunking its always advisable to pull the cable off the roll in the same way its been wrapped on & you’ll never get twists. I usually put the roll down in 1 corner of the room (round side down) & yank the end of the cable while walking to the other corner of the room & a smooth line of cable comes off the roll. Or even better with many cable rolls make a wooden stand to pull cable off. You’ll enjoy putting cables in the trunking next time. Try it once & you’ll remember this comment. Great video overall, liked.
@muhammadtahir3952
@muhammadtahir3952 8 ай бұрын
Well done 👍 good job sir your all practical work very well explained step by step
@utuberlars
@utuberlars 3 жыл бұрын
This is a great Video. In Germany its not legal to tell the People how it works!!! THANK YOU!!!
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Thanks! Glad that it helped little bit!
@plaffoner
@plaffoner Жыл бұрын
Very teachable video, congratulations.
@DartaineanBansavi
@DartaineanBansavi Ай бұрын
Hi thank you I really like your video,I'm also loving doing electrical work n I'm working as and TA for also 2 years now.. I'm also going to connect a some thing as you showed on the video and really need some more headvice from you,if you would love to help me out...?!
@AOK000
@AOK000 5 ай бұрын
the switch in video is a Millers Falls ATS switch
@tosynoliveswire1983
@tosynoliveswire1983 3 жыл бұрын
Actually I like ur work it's amazing
@bestricebrown-cp8fe
@bestricebrown-cp8fe Жыл бұрын
Very interesting... I am from Ghana and I need a training, how can I participate. Thank you
@mariusvalentin7109
@mariusvalentin7109 6 ай бұрын
Very Nice IT helped me alot where are You born because english is not your first language?
@stevepalmer3435
@stevepalmer3435 11 ай бұрын
Nice video, question, the main current from the grid go to the transfer box or to the main panel broad.
@kevin00861
@kevin00861 4 жыл бұрын
Thank you Sir for your video, it`s very explanatory ! Yet, I have one question please , You connected the city main wires ( Black once ) to the ATS via a switch But the power coming from the ATS to which Switch did you connect it ? Do we need another switch ?
@AxiomBalkan
@AxiomBalkan 4 жыл бұрын
Main power from the meter goes in to the ATS, and then from ATS back to main fuse board, now you can put between isolator switch just to be on the safe side!
@jaylendamari5451
@jaylendamari5451 3 жыл бұрын
you prolly dont care but if you are bored like me during the covid times you can stream pretty much all the latest series on InstaFlixxer. Have been streaming with my girlfriend lately xD
@jaydenthiago1101
@jaydenthiago1101 3 жыл бұрын
@Jaylen Damari Yea, I have been using Instaflixxer for months myself :)
@selemanibangala7455
@selemanibangala7455 Жыл бұрын
Thank you for the good video, but your music is too loud.
@ssennonojohnmary4406
@ssennonojohnmary4406 2 жыл бұрын
Thanx, but please show how you connect that signal cable to generator and in the change over system.
@joaozitomorais6672
@joaozitomorais6672 2 жыл бұрын
Very good your explanation, but what is very important for US to know is wiring diagram for Ats and AMF... please send me the wiring diagram for Ats and AMF
@ahmedwathab302
@ahmedwathab302 3 жыл бұрын
thank you for the video .but have one question ? the ATS has house net and generator may i know how did u connect it ?or if can contact u personality ? thank you
@Misty7309
@Misty7309 3 жыл бұрын
Thanks for this video. I love it. Can you please provide us with who the manufacturer is and the model # of the transfer box. Where to buy is also appreciate. Thanks
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Hi! Thanks for the coment, the only thing i know is that equipment is Powermate PMD 5000s, and it did came as a package, gen. Plus ATS, and customer bought it in Spain, sorry but thats all i know...
@alexgempfer937
@alexgempfer937 11 ай бұрын
I got similar setup, however my ATS which is although look similar, supports 3 phase generator as well and therefore has 4 terminals on the grid/generator/out connections. Any idea which terminals should be used for 1-phase generator. Also, how did you grounded the generator and ats box?
@fideliskabwe5380
@fideliskabwe5380 2 ай бұрын
What could be the possible causes of the genset failing to autostart(not even cranking the engine).I recently installed a similar genset with exact ATS but can't start automatically, the failure indicator continues to blink.
@markrobinson3884
@markrobinson3884 4 жыл бұрын
Thanks good explanation where can I get this same ATS to buy?
@AxiomBalkan
@AxiomBalkan 4 жыл бұрын
Hi! Im not sure, customer supplied generator we just installed it... thanks for coment!
@utuberlars
@utuberlars 3 жыл бұрын
ademax-strom.de/index.php?route=product/search&search=ats
@AOK000
@AOK000 5 ай бұрын
its a millers falls ATS
@Purowalangkwenta
@Purowalangkwenta 3 жыл бұрын
Nice video sir. I have a quick question 1. If I have a 12KVA generator, how may amps do I need for the ATS? 2. If my utility box has a 250amp load. How many amps of ATS do I need? 3. Lastly, If the power goes out I will use about 7kva. So 12Kva is enough but do I still need a 250amp ATS since my Utility box is 250amp?
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Hi, thanks, if it is 3 phase gen, you need at least 25A per phase for ATS, that 250A looks a bit too much, specialy if it is for domestic use, so you need to size your ATS acording to your ussage... so if your place doesnt use more than 12KVA at any point, then you are ok with 4 times 25A...
@Purowalangkwenta
@Purowalangkwenta 3 жыл бұрын
@@AxiomBalkan Thanks for the swift reply. It would be for a single phase since it's a house only. So would you think a 100amp ATS is sufficient even though I have a 250amp breaker from the main utility line? thanks and keep safe
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
@@Purowalangkwenta definetly, more than enough, just tell me please what Voltage sistem are you on? 110 or 220V?
@Purowalangkwenta
@Purowalangkwenta 3 жыл бұрын
@@AxiomBalkan It is in 220v.
@bamboo911
@bamboo911 Жыл бұрын
What brand is ATS, 220v? Great video and impressive cable routing.
@AOK000
@AOK000 5 ай бұрын
millers falls ats switch
@giubboni374
@giubboni374 8 ай бұрын
I have a hyundai inverter generator mod.65158, and ATS hyundai mod.65140. I installed the cables from the meter, to the ATS control unit things net input, I installed it to the 16 ampere socket of the generator, in the generator input, I left it empty, ats output , when I turn off the power the generator starts, when the power comes back it can't stop, what could it be, thanks
@danieljohnson7909
@danieljohnson7909 3 жыл бұрын
Hi thanks. How do you adjust the speed to bring un the hertz on those diesel generators ?
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Hi! This generator has automatic throttle, so it keeps voltage and frequency constant no mather what the load is!
@danieljohnson7909
@danieljohnson7909 3 жыл бұрын
@@AxiomBalkan I have one but it's not staying at 60 hertz. It runs at 58 and only can bring it up by hand on the governor. The one I have will not go up from 58 to 60 unless I manually move the governor.
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
@@danieljohnson7909 try to measure frequency with some good instrument, dont rely on one on the generator, maybe is off... and if you are at 59 or 61 you should be ok...
@danjohnson7832
@danjohnson7832 3 жыл бұрын
@@AxiomBalkan I did all of that. It is an older model speed/governor where it is set with a bolt into the start position.
@gaizizy1894
@gaizizy1894 3 жыл бұрын
what if we have the government power running but we want to use our stand by generator for 3days only then later use the normal power supply from government? will have to turn off the transfer switch manually?
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Yes that is correct
@vasilismanolis2455
@vasilismanolis2455 3 жыл бұрын
When the generator works doesnt the volts you are generating go back the the city net? Did you installed somekind of relais to break the cirquit back to the city?
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
That is what ATS do, automatic transfer switch. There is two contactors inside wich when one is on another one is off so there is no chance for power to go back to main network...
@vasilismanolis2455
@vasilismanolis2455 3 жыл бұрын
@@AxiomBalkan when there is no use of the generator the whole household appliances go through the ATS? Ca nit handle such amperage?
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
@@vasilismanolis2455 yes thats correct! You have to size correctly ats to handle power! This one is 8KW...
@kayodewasiu7758
@kayodewasiu7758 Жыл бұрын
Good work please I want to learn this how can I pls reply
@dammy-okayofficialofficial2557
@dammy-okayofficialofficial2557 8 ай бұрын
Explain for us, is it relay which cause Generator to run automatically?
@gatz1014
@gatz1014 3 жыл бұрын
Good day sir!!! Do you have any idea where to connect the ats cable to yamada diesel generator 18kva, thanks
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Can you please send me some pictures and i will have a look in to it!
@gatz1014
@gatz1014 3 жыл бұрын
How can I paste the picture sir
@gatz1014
@gatz1014 3 жыл бұрын
What's your email account sir, thanks
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
aksiohm@yahoo.com
@nthabisengntsoane8877
@nthabisengntsoane8877 3 жыл бұрын
How do u connected the signal ats cable
@saintofgod6707
@saintofgod6707 3 жыл бұрын
Please sir greetings. Where do you connect the automatic start to the generator
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
This generator in the video comes with ATS and cable to connect them together, you see that white cable it has 5 pin contact on both ends and that how i connected them, so they can comunicate when to start and when to stop generator... every brand is diferent, so talk to your supplier about how to connect them together...
@RobertGenerators
@RobertGenerators Жыл бұрын
So, the unit is exhausting into the garage? Not good...
@AxiomBalkan
@AxiomBalkan Жыл бұрын
If you pay attention on video, around 6:30 i explain how exhaust is routed outside!….
@mancavechronicles2139
@mancavechronicles2139 9 ай бұрын
Where can I purchase that ATS box ?
@mwaledex
@mwaledex 2 жыл бұрын
Can the ats work in manual mode without a signal cable???
@AxiomBalkan
@AxiomBalkan 2 жыл бұрын
Yes it can, but then it’s not a ATS ( automatic transfer switch) 😉
@mwaledex
@mwaledex 2 жыл бұрын
@@AxiomBalkan great... I want to use it as a manual transfer switch unfortunately without the signal cable the contactors are not energizing or actuating....
@AxiomBalkan
@AxiomBalkan 2 жыл бұрын
@@mwaledex you have to install taster switches on and off, and connect them to the electromagnet of the contractor like that you will have manual control over transfer…
@mwaledex
@mwaledex 2 жыл бұрын
@@AxiomBalkan ok thanks a lot
@AxiomBalkan
@AxiomBalkan 2 жыл бұрын
@@mwaledex you are welcome
@davidnganga3243
@davidnganga3243 2 жыл бұрын
DOES THE ATS START A NON AUTOMATIC.
@AxiomBalkan
@AxiomBalkan 2 жыл бұрын
There is two modes, auto and manual
@goonsville340
@goonsville340 3 жыл бұрын
What about the exhaust that looks like enclosed area
@AxiomBalkan
@AxiomBalkan 3 жыл бұрын
Yes it is, but exaust is routed outside with ridgid copper pipe, 50mm (2")
@jasonschaeffer72
@jasonschaeffer72 25 күн бұрын
I'm thinking the garage is probably NOT the best place for the generator ☠️💀
@RobertGenerators
@RobertGenerators Жыл бұрын
Way undersized for anything other than a few circuits. No HVAC systems, maybe a window unit. No large appliances, electric range is out.
@AxiomBalkan
@AxiomBalkan Жыл бұрын
Again on the end of this video is explained the size of gen and what the customer will use it for! So thanks for the comments but next time watch the full video before comenting! 😉
@balkandiytutorials7659
@balkandiytutorials7659 Жыл бұрын
Pricaj srpski bree
Generator ATS (Automatic Transfer Switch)
11:25
Gavin’s Garage
Рет қаралды 16 М.
Westinghouse ST Automatic Generator Transfer Switch
5:38
Homestead Engineering
Рет қаралды 79 М.
Gym belt !! 😂😂  @kauermotta
00:10
Tibo InShape
Рет қаралды 18 МЛН
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 10 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 36 МЛН
Turning standard portable generator into an automatic generator
45:35
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 11 М.
Automatic generator changeover switch (with schematic).
27:06
bigclivedotcom
Рет қаралды 848 М.
HAD TO STOP THE APPRENTICE - FIRST BOARD SWAP
15:55
Bright Spark Electrical (midlands)
Рет қаралды 10 М.
How to Wire an Automatic Transfer Switch Panel @CNCElectric1988
9:26
Quick & Easy Generator Transfer Switch Install - Reliance ProTran 2
13:10
22KW GENERATOR INSTALL with 200 AMP ATS
24:39
James Foster LS3 TA
Рет қаралды 349 М.