GENIE BOOM LIFT WILL NOT START NO CRANK - FIXED!

  Рет қаралды 37,166

DIY GEEK

DIY GEEK

Күн бұрын

I found the issue with my Genie Boom Lift S60. I believe this work with Genie Boom Lift S40, S45, S60, S65, S85 as well.
After hours of troubleshooting I found out the culprit was the circuit breaker from the base control panel. Watch the video how I used a voltage meter to find where the voltage stopped flowing and realized it was the circuit breaker that caused the boom lift not the start.
Please use my link below to buy Circuit Breaker to support my channel:
✅ ✅ 👉 amzn.to/39W96M0
Thank you for watching. Please LIKE and SUBSCRIBE!
#genieboomlift #boomlift #genienostart

Пікірлер: 18
@DIYGEEKTEXAS
@DIYGEEKTEXAS 2 жыл бұрын
Please use my link below to buy Circuit Breaker to support my channel: ✅ ✅ 👉 amzn.to/39W96M0 Thanks
@captainpowblox7172
@captainpowblox7172 2 жыл бұрын
Dude you are right, I have the same issue and it was the circuit breaker!!!
@paulwatson255
@paulwatson255 Жыл бұрын
I am in Jamaica I have a genie z80/60 I have a question for u it's a 08 lift hopefully u can help me
@silverbacksolutions7993
@silverbacksolutions7993 2 ай бұрын
This legit worked! Funny thing is isolated it to being related to that breaker to some degree prior but didn’t know next direction should take Thanks bud
@mazerunner1054
@mazerunner1054 11 ай бұрын
Had our S60 come back as it's not cranking. Didn't have to time to get under the panel, but will give this a look as I'm hoping it's not a fuel delivery issue. Appreciate the tip.
@DIYGEEKTEXAS
@DIYGEEKTEXAS 11 ай бұрын
Did it recently ran out of diesel? or is the diesel low? Unfortunately 9 out of 10 times with these diesel large equipment it is MOST LIKELY diesel fuel delivery issue. There is a priming pump you can push usually by the diesel filter. Try pushing that and crank it. If that makes a difference then you are confirmed it is a fuel delivery issue.
@vinnyplace1269
@vinnyplace1269 Жыл бұрын
This just happened to mine today. I had to have someone pass 2x12 from 3rd story window to genie lift. I will try this to trouble shoot in the morning. Thanks for the help!
@jerrymagdalas6146
@jerrymagdalas6146 6 ай бұрын
Thanks for this video it is verry use full or us.i have a question it is same problem with the S-65 GENIE BOOMLIFT because the motor is not cranking
@calixtovargas8828
@calixtovargas8828 3 ай бұрын
What nod stop engine the bottom stop Genie Z-60/34 please
@aftabahmedkhan7734
@aftabahmedkhan7734 4 күн бұрын
Showing 7617 alarm , reset it like calibration done for platform overload But stil not working
@blasterman3394
@blasterman3394 2 жыл бұрын
Brilliant thanks
@pzflo
@pzflo Жыл бұрын
My Genie will die after 1/2 hour of use and no power anywhere, maybe my circuit breaker is getting hot and loses power. Great idea check.
@JuanPerez-ei8ke
@JuanPerez-ei8ke 2 жыл бұрын
Hello friend, I have a problem with my boom lift because the alarm turns on when I want to drive it.
@syedwasiquehussain3195
@syedwasiquehussain3195 6 ай бұрын
Hi, I've tried to update the software on Genie S-85 XC year 2018 (Bootloader 1302967-1.7.1 and Firmware 1302966-1.9.5) via USB. The Bootloader successfully installed and during updating of Firmware DISCON, PCON main, PCON secondary and TCON secondary successfully update 100% but TCON main not updating and showing message "Sub-ECU not responding try to recovery. I've checked wiring and CAN resistance on J5 and J10 connectors, all good. The Genie have ALC-600 controllers. Can you please help me. Thanks in advance.
@aftabahmedkhan7734
@aftabahmedkhan7734 4 күн бұрын
Model z 45 xc
@paulwatson4650
@paulwatson4650 Жыл бұрын
hello paul have a question for you i have as65 # 15229 its a 2007 every function works from ground and platform only problem iam having is boom up very very slow from ground and platform very very slow i put my hydraulic pressure guage on it iam only getting little below 2000 psi when i try to boom up
@DIYGEEKTEXAS
@DIYGEEKTEXAS Жыл бұрын
You have a hydraulic issue not electronic. I would start by checking for leaks, hydraulic fluid level and hydraulic pump.
@paulwatson4650
@paulwatson4650 Жыл бұрын
@@DIYGEEKTEXAS i replace the valve and it works good kooool
Start-stall: Genie Boom Lift!
24:02
Pine Hollow Auto Diagnostics
Рет қаралды 89 М.
HOW TO OPERATE A GENIE / JLG BOOM LIFT - GEARHEADZ
6:15
GearHeadz Equipment Sales
Рет қаралды 346 М.
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 1 МЛН
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 199 МЛН
Real Or Cake For $10,000
00:37
MrBeast
Рет қаралды 60 МЛН
JLG Scissor Lift: No-crank from Platform
12:33
Pine Hollow Auto Diagnostics
Рет қаралды 23 М.
One-Way Genie (No Reverse Drive) - Part 1
19:22
Pine Hollow Auto Diagnostics
Рет қаралды 20 М.
Scissor lift will not drive !!
3:01
Manuel Diaz
Рет қаралды 36 М.
How to read Genie ALC500 fault codes
2:39
Genie Service
Рет қаралды 8 М.
Genie Telehandler NO Crank NO Start - 2 HOUR Drive for a 2 MINUTE Fix!
5:39
One-Way Genie - Part 2 (Repairs)
14:53
Pine Hollow Auto Diagnostics
Рет қаралды 37 М.
Boom Lift not driving Fast (issue)
3:19
Manuel Diaz
Рет қаралды 11 М.
Genie AWP-20S push around personnel lift operation demo
5:28
Alexander Equipment Rental, Inc.
Рет қаралды 62 М.
desbloqueo de manlift genie z-135
1:09
Sam Buendia
Рет қаралды 17 М.
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 1 МЛН