@BixbyConsequence4 жыл бұрын
Well I hope there's a way for you to make it more durable. Ours just crapped the bed at 5 years. Compared to 35 years on the previous unit that was still running.
@alexfagard36183 жыл бұрын
@Thomas Rock it has capacitors on the control board inside the bottom housing of the motor. aka another thing that can go wrong and isn't easy to replace like an external capacitor.
@alexfagard36183 жыл бұрын
@Thomas Rock i find it funny that the motor i have has all this fancy control circuitry and is basically turned on and off by a relay (no variable speed control board in the outdoor unit) - so it probably could be replaced with an old-style motor that doesn't have this without any issues so long as a capacitor is added
@ranatoliy3 жыл бұрын
Where can I buy online the ECM 142 DX05 control box? Is ECM142R compatiable wit old motor? The same question: where to buy it? Thanks in advance for the answer.
@tonylohe2 жыл бұрын
Did you get the ecm.? I'm looking for the same model
@usahoangsatruongsa4 жыл бұрын
Excellent instructional video and still you did not specify what kind of communication control voltage goes in the motor,is it AC or DC voltage? Thanks
@KirkA09063 жыл бұрын
Signal wires are White and Yellow, Blue is common. Control voltage is 24vac.. See this documentation. www.regalbeloit.com/-/media/Project/RGLB/RegalBeloit/Files/Genteq-Technical-Files/Application-Notes/Product-Information/gettingstarted142R_6_8_09_V1.pdf?la=en&hash=E9F13B6F1B469DD2A508C6351FB2E7C5
@bentleyjarrard8853 жыл бұрын
@@KirkA0906 Well according to the documentation you referenced above, low voltage control to the ECM motor comes directly from the thermostat and is in fact 24VAC (not dc) which is what the step down transformer located in the air handler/furnace outputs.
@KirkA09063 жыл бұрын
@@bentleyjarrard885 Sorry. My bad.
@bentleyjarrard8853 жыл бұрын
@@KirkA0906 No problem, I'll let you know when I become perfect. Probably not any time soon. Forgot to thank you for the documentation link above. I read through it, very helpful as I have a 2 stage Goodman condenser that is now 10 years old.
@khaledalnahary Жыл бұрын
I wish you to kindly send the scheme to roll this type of your company's esteemed engines and how to connect between group files for takeoff files and operating files, with many thanks and appreciation
@hangngoaigiare2 жыл бұрын
where is the VS motor?
@CarolHenderson-xz2iw11 ай бұрын
Two of these have died in my Rheem A/C over the past 6 years. He mentions surge protection, but as an electrical engineer I have studied the circuit diagram, there is a thermistor, for inrush current control, but NO surge protection.
@jameschen19133 ай бұрын
Mine same, 4.5 years two of them died, this is piece of junk motor
@fixer6873 жыл бұрын
I have two 142R's with bad bearings. When mounted shaft down they take in water through the casing bolts and the bottom bearing is consumed in water. I seal the top bolts with seam sealer at install. Best to inspect your unit before its too late. This is not a good outdoor motor design.
@Darkblend2 ай бұрын
These will need replaced every 18 to 24 months. I'm on my 3rd. Male sure you install a high pressure switch.
@PavelBarkar3 жыл бұрын
my 142R died in 4 years, ridiculous
@zhiyuanchen88572 жыл бұрын
Mine lasted only 3 years
@babyboyge11 ай бұрын
One year and nine months- not even pass the second summer!
@usahoangsatruongsa8 ай бұрын
It seemed someone named them Money sucking POS !
@stanleyvyvlecka31254 жыл бұрын
No good
@tommytran297510 ай бұрын
these are junk!!! i bought a brand new rheem unit.. replaced it 2.5 years ago and 2.5 years later today i just literally had to replace it again!
@jameschen19133 ай бұрын
Mine same, this shitting quality shouldn’t be in the market, is there somewhere for consumers to get reimbursed by the manufacturer? We should file lawsuits against them
@zapsurf1343Ай бұрын
3 year old Rheem unit fan motor died. Complete garbage.