No video

GFCI, Special Purpose Type 26.3

  Рет қаралды 6,482

MikeHoltNEC

MikeHoltNEC

Күн бұрын

Class “A” GFCI devices have been around for so long that we’ve all become pretty familiar with them, but have you ever heard of an “SPGFCI” (special purpose ground-fault circuit interrupter)?
Learn what you need to know by watching the video in which Mike and the team discuss this new special-purpose ground-fault protection device.
This video is extracted from Mike Holt's Understanding Electrical Theory Library www.mikeholt.c.... For additional information call 888.632.2633.
For decades, Mike Holt Enterprises has been the go-to resource for electrical training. Our mission is to empower electrical professionals like you to master the Code, excel in exams📝, and elevate your electrical knowledge..
👉 Explore Exam Preparation Tips and Training at www.MikeHolt.c...
🚀 Find Electrical CEU courses at www.MikeHolt.c...
⬆️ Level Up your school's electrical training program with Mike Holt Enterprises at www.MikeHolt.c...
Whether you're gearing up for an exam or looking to enhance your electrical knowledge, we've got you covered. We offer instructor and curriculum support, a variety of continuing education options, free videos, graphics, and a wealth of valuable resources.
📌 Stay Connected:
/ mikeholtenterprises
/ mikeholtenterprises
/ mike-holt-enterprises-inc
🔗 www.mikeholt.com
✅ Don't miss out on the latest updates and exclusive content. Subscribe to this channel now - Click here to subscribe: www.youtube.co....

Пікірлер: 17
@jaybee1570
@jaybee1570 11 күн бұрын
Pursuant to Brian’s comments and Mikes response at 3:55 the pigtail or plug on neutral is for the power supply to the gfci or afci breakers which powers the microcontroller (computer) analyzing fault conditions on the circuit. But I don’t quite understand how the 240V GFCI breaker works. A 120 volt GFCI breaker or receptacle compares the current on the ungrounded and grounded conductor and trips over the design threshold. So what does the 240v breaker do compare the current on each ungrounded conductor?
@24electricservice
@24electricservice 8 ай бұрын
Very good information!
@genebowdish.mageniemagic
@genebowdish.mageniemagic 5 ай бұрын
What is the allowable current with objectionable current on the grounding system ?
@aaronwidder4458
@aaronwidder4458 8 ай бұрын
Mike, is there any chance you can do a whole video, or something to that effect on just neutrals? Sizing neutrals, linear & Non-linear loads Etc....This would be greatly appreciated, and I would definitely add it to my collection of many of your other books. Thanks Mike!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
This is covered in my Exam Prep book. Sorry that's the best I can do.
@ChrisHVAC
@ChrisHVAC 8 ай бұрын
Good Stuff Mike!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Thanks
@kevinkuang9429
@kevinkuang9429 8 ай бұрын
For a 2 pole breakers with a pigtail, does the GFCI work if pigtail is not connected? Why or why not? The return current can flow on one of the two poles. Thanks.
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
A two-pole GFCI breaker needs a neutral for the internal circuitry.
@kevinkuang9429
@kevinkuang9429 8 ай бұрын
@@MikeHoltNEC But there's no neutral going out to the equipment right? Jus two hot wires. Thanks!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
If the load doesn't need a neutral, then no load neutral required, but a 'line' neutral is required
@kevinkuang9429
@kevinkuang9429 8 ай бұрын
@@MikeHoltNEC Thank you. Keep up the good educational content!
@coldfinger459sub0
@coldfinger459sub0 8 ай бұрын
Since houses are going to be going all electric. I could imagine several 240 circuits requiring a few of these in a medium to large size red residence. Are we looking at an extra cost of an extra thousand to $2000 for a handful of these? .
@mrlescure
@mrlescure 8 ай бұрын
Those circuits are still 120 to ground. It's not line-to-line voltage.
@thebuildingcodeforum
@thebuildingcodeforum 8 ай бұрын
These do not apply to 240vac systems, just line to ground voltage of 150vac or more.
@coldfinger459sub0
@coldfinger459sub0 8 ай бұрын
@@thebuildingcodeforum I have to relist to the video on the wording. I know currently it’s only line to line ground 150 voltage. But in the future and coming up, I thought they were talking about to do the same thing as Europe and Canada does ground fault on 240 V like they do in other countries it’s been mandated and implemented into codes around the world . except the United States were a little lacking behind the times
Ground-Fault Protection of Equipment
4:58
MikeHoltNEC
Рет қаралды 3,7 М.
Ground-Fault Circuit Interrupters (GFCIs)
23:41
MikeHoltNEC
Рет қаралды 10 М.
КАКУЮ ДВЕРЬ ВЫБРАТЬ? 😂 #Shorts
00:45
НУБАСТЕР
Рет қаралды 3,3 МЛН
7 Days Stranded In A Cave
17:59
MrBeast
Рет қаралды 87 МЛН
AFCIs, Clearing Series and Parallel Arcing Fault
17:47
MikeHoltNEC
Рет қаралды 6 М.
Industry Voltages
18:44
MikeHoltNEC
Рет қаралды 8 М.
Dangers of Multiwire Circuits 28.6
11:40
MikeHoltNEC
Рет қаралды 7 М.
Refrigerant Overcharge Troubleshooting and Prevention
21:47
HVAC School
Рет қаралды 178 М.
Health Care Wiring Methods, NEC 2020 - [517.13], (17min:50sec)
17:50
How Surge Protective Devices Function
10:41
MikeHoltNEC
Рет қаралды 9 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 227 М.