Since their introduction in the 1970s, there is no question that ground-fault circuit interrupters (GFCI) have saved lives! Take the time to watch the video where Mike and the team explain the theory behind ground-fault circuit interrupters.
This video is extracted from Mike Holt's Understanding Electrical Theory Library, to learn more about this topic visit www.mikeholt.com/Theory. For additional information call 888.632.2633.
For decades, Mike Holt Enterprises has been the go-to resource for electrical training. Our mission is to empower electrical professionals like you to master the Code, excel in exams📝, and elevate your electrical knowledge..
👉 Explore Exam Preparation Tips and Training at www.MikeHolt.com/examprep
🚀 Find Electrical CEU courses at www.MikeHolt.com/CEU
⬆️ Level Up your school's electrical training program with Mike Holt Enterprises at www.MikeHolt.com/Instructors
Whether you're gearing up for an exam or looking to enhance your electrical knowledge, we've got you covered. We offer instructor and curriculum support, a variety of continuing education options, free videos, graphics, and a wealth of valuable resources. 📌
Stay Connected:
/ mikeholtenterprises
/ mikeholtenterprises
/ mike-holt-enterprises-inc
🔗 www.mikeholt.com
✅ Don't miss out on the latest updates and exclusive content. Subscribe to this channel now - Click here to subscribe: www.youtube.com/@MikeHoltNEC?...

Пікірлер: 44
@LLAMA-gym
@LLAMA-gym 3 ай бұрын
Didn’t realize how much I just love watching someone passionate about a subject. Inspiring to levels absolutely unmeasurable.
@MikeHoltNEC
@MikeHoltNEC 3 ай бұрын
Aww thank you for noticing my passion.
@davidredpath4781
@davidredpath4781 8 ай бұрын
We need more people like Mike Holt in this world
@Ariccio123
@Ariccio123 4 ай бұрын
I haven't even watched the whole video yet, I just want to evangelize about the wonders of audible alarm GFCIs - these should be the standard! It's a really user friendly option for everybody!
@ideclarejoshua
@ideclarejoshua 8 ай бұрын
In school getting my apprenticeship hours, learning this stuff now. Cool to see you are posting on KZbin, my second home. Thumbs up!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Welcome to a great trade! God Bless, Mike
@j81851
@j81851 8 ай бұрын
Mike you look so good. Serving the Lord and others along with a good life has a very positive effect. Thank you for all your efforts. After 50 years in the trade you are the champion of electrical safety and a personal hero of mine. Long life good health and prosperity to you. Love to meet you one day and return a smile and a warm handshake! Be blessed my brother.
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
How sweet is this message my Brother. Let's make it happen.
@OnusofStrife
@OnusofStrife 2 ай бұрын
Enjoying your videos as a curious homeowner laymen. I recently went around my house and tested all my outside GFCIs. Some did not reset. Watching this made me realize the failure to reset means the receptacle needs to be replaced as the electronics have failed. That makes sense but was totally not obvious.
@MikeHoltNEC
@MikeHoltNEC 2 ай бұрын
Wow, scary. Glad my work helped you make your home safer.
@matthewcarroll6640
@matthewcarroll6640 8 ай бұрын
Mike definitely has a method of teaching that makes it easy to follow and understand, so definitely gotta give him props. Thank you for all your materials. Mike.
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Thank you!
@shaneoakley8757
@shaneoakley8757 2 ай бұрын
I’m in an apprenticeship program with the state of NC to get a standard certification as a level 1 electrical inspector and let me just tell you. Mike Holt gets mentioned a lot! 😎 Love and appreciate these videos! I keep them playing as I travel all over the state
@MikeHoltNEC
@MikeHoltNEC 2 ай бұрын
Lol, give a shout out to them for me.
@shaneoakley8757
@shaneoakley8757 2 ай бұрын
@@MikeHoltNEC I sure will!!
@TRYtoHELPyou
@TRYtoHELPyou 8 ай бұрын
test monthly, will do. Even though this is geared towards the students and professionals this is great information for the non-professional non-student (formal) trying to better themselves by gaining knowledge about the subject. Thanks all for doing what you do!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Thank you.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 8 ай бұрын
Great explanation of imbalance
@highwaymen1237
@highwaymen1237 8 ай бұрын
Great video. Watched you're downhill bike video, very impressive.
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Lol... thanks.
@wuilliamscoa3467
@wuilliamscoa3467 Ай бұрын
Think about your answer!
@MikeHoltNEC
@MikeHoltNEC Ай бұрын
What?
@mikeadler434
@mikeadler434 8 ай бұрын
👍👍
@robertseverino8931
@robertseverino8931 8 ай бұрын
Hi Mike! I appreciate you sharing all your knowledge with all of us which has always been of an immense value to me. I have a request for you that’s probably been done in the past, but I’m sure you could make it happen. If possible to transfer all your electrical books ober to Autible or any audio format. If you do have it in this format, please advise or send link. Thank you!
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Send me an email, Mike@MikeHolt.com, and let's discuss this further.
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
All of our Products that include Video also include audio streaming.
@harpreetkaur5947
@harpreetkaur5947 8 ай бұрын
Hello Mike, I have been watching and learning through your vedios for few years now. If possible can you please make a vedio on NEC Article 501. I know you made a vedio few years ago on Hazardous Area Classification. But if you would make a detailed vedio on wiring methods, Conduits, Fittings, Conduit Seals, Enclosures, Termination boxes inside Class 1 Div 1, Class 1 Div 2 areas. What are design considerations at the boundaries of each area. I work in Waste Water Industry, if you could explain using examples from lift station etc that would be great. There are multiple people around me that can use your guidance for a better understanding of Article 501. Also this will touch some topics of NFPA 820. Thanks.
@davem5392
@davem5392 8 ай бұрын
I would really appreciate with all the commercial restaurant requirements if you could go over function of 3 phase breakers. I think most do not understand this
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
? A three-phase breaker functions just like a two-pole or single-pole breaker...
@bohill1832
@bohill1832 7 ай бұрын
According to the NEC, can GFCI outlets be installed in bathrooms 16” above finished floor.
@MikeHoltNEC
@MikeHoltNEC 7 ай бұрын
The required sink receptacle in bathrooms must be installed in accordance with 210.52(C), which would not permit it to be 16" above finished floor. However other receptacles in the bathroom or other rooms in residential or commercial occupancies can be installed at any height, even in the floor.
@zebiosogliani7132
@zebiosogliani7132 6 ай бұрын
Why not use GFCI break type in the electrical panel instead of the outlet type?
@MikeHoltNEC
@MikeHoltNEC 6 ай бұрын
GFCI is set to trip between 4 - 6 mA, if you used it for the entire house, expect that you'll be losing power often.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 8 ай бұрын
I came up with an idea, imagine a non-contact voltage tester or detector, that is a watch type that you wear on your wrist, when you touch it hot wire, watch detects voltage, transmits signal to cell phone, cell phone transmits signal to disconnect with receiver and disconnects circuit, and or entire sub panel or panel, what do you think about my idea ? Oh, maybe false tripping ? Insulated coil Ring on index finger that detects current through finger, then to watch, cell phone, and trip circuit, sub panel or panel or disconnect with receiver
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Sounds like it's complicated that this watch would know what breaker to turn off. Let me know if you ever get such a device made.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 8 ай бұрын
@@MikeHoltNEC I’m working on it now, not as easy as I thought to detect voltage, current, I am learning about op-amps, I imagine when I figure this part out, the rest will be easy, I am thinking
@billycroan2336
@billycroan2336 8 ай бұрын
I think it would be great if you could measure and alarm for ground fault current at the main breaker. Put both service conductors and neutral through a CT, that would confirm there's no leakage to the ground through duct work, piping, telephone, cable, or whatnot. I don't want the whole house switching off like it would in Europe with an rcd. But I would like to know what's the normal level, and be notified it it increases
@MikeHoltNEC
@MikeHoltNEC 8 ай бұрын
Would be nice.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 8 ай бұрын
@@MikeHoltNEC I just posted one of my circuits I was talking about, could be smaller, could be wireless, I have many more ideas on this topic, Gene Bowdish
@wuilliamscoa3467
@wuilliamscoa3467 Ай бұрын
Máster you should translate your books to spanish you going to make a lot of Money!
@MikeHoltNEC
@MikeHoltNEC Ай бұрын
My products are based on the National Electrical Code for those living in the US. I feel that to provide a safe installation, the electrical professional needs to speak and read English. So there is no plan to translate any of our products into Spanish. Note: Money doesn't drive me; just electrical safety.
@wuilliamscoa3467
@wuilliamscoa3467 Ай бұрын
@@MikeHoltNEC👍🏼
@wuilliamscoa3467
@wuilliamscoa3467 Ай бұрын
The nec is translated to spanish, to humble my friend!
@MikeHoltNEC
@MikeHoltNEC Ай бұрын
@@wuilliamscoa3467 What does this have to do with your original question and my original response.
GFCI, Special Purpose Type 26.3
13:07
MikeHoltNEC
Рет қаралды 6 М.
Neutral-to-Earth Voltage (NEV), NEC 2020, (44min:40sec)
44:40
MikeHoltNEC
Рет қаралды 216 М.
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 27 МЛН
Was ist im Eis versteckt? 🧊 Coole Winter-Gadgets von Amazon
00:37
SMOL German
Рет қаралды 39 МЛН
AFCIs, Clearing Series and Parallel Arcing Fault
17:47
MikeHoltNEC
Рет қаралды 6 М.
Coordination, Overcurrent Protective Devices
14:23
MikeHoltNEC
Рет қаралды 8 М.
Difference Between System grounding and Equipment grounding
8:02
Does Current Flow Through The Neutral Wire?
7:41
eFIXX
Рет қаралды 325 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
Branch Circuit, Multiwire, NEC 2020 - [210.4], (19min:38sec)
19:38
MikeHoltNEC
Рет қаралды 234 М.
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 84 М.
Grounding, System and Equipment [250.4, 2020 NEC]
33:35
MikeHoltNEC
Рет қаралды 101 М.
How Surge Protective Devices Function
10:41
MikeHoltNEC
Рет қаралды 8 М.