Didn’t realize how much I just love watching someone passionate about a subject. Inspiring to levels absolutely unmeasurable.
@MikeHoltNEC8 ай бұрын
Aww thank you for noticing my passion.
@Dredpath1 Жыл бұрын
We need more people like Mike Holt in this world
@ideclarejoshua Жыл бұрын
In school getting my apprenticeship hours, learning this stuff now. Cool to see you are posting on KZbin, my second home. Thumbs up!
@MikeHoltNEC Жыл бұрын
Welcome to a great trade! God Bless, Mike
@matthewcarroll6640 Жыл бұрын
Mike definitely has a method of teaching that makes it easy to follow and understand, so definitely gotta give him props. Thank you for all your materials. Mike.
@MikeHoltNEC Жыл бұрын
Thank you!
@OnusofStrife8 ай бұрын
Enjoying your videos as a curious homeowner laymen. I recently went around my house and tested all my outside GFCIs. Some did not reset. Watching this made me realize the failure to reset means the receptacle needs to be replaced as the electronics have failed. That makes sense but was totally not obvious.
@MikeHoltNEC8 ай бұрын
Wow, scary. Glad my work helped you make your home safer.
@TRYtoHELPyou Жыл бұрын
test monthly, will do. Even though this is geared towards the students and professionals this is great information for the non-professional non-student (formal) trying to better themselves by gaining knowledge about the subject. Thanks all for doing what you do!
@MikeHoltNEC Жыл бұрын
Thank you.
@j81851 Жыл бұрын
Mike you look so good. Serving the Lord and others along with a good life has a very positive effect. Thank you for all your efforts. After 50 years in the trade you are the champion of electrical safety and a personal hero of mine. Long life good health and prosperity to you. Love to meet you one day and return a smile and a warm handshake! Be blessed my brother.
@MikeHoltNEC Жыл бұрын
How sweet is this message my Brother. Let's make it happen.
@shaneoakley87578 ай бұрын
I’m in an apprenticeship program with the state of NC to get a standard certification as a level 1 electrical inspector and let me just tell you. Mike Holt gets mentioned a lot! 😎 Love and appreciate these videos! I keep them playing as I travel all over the state
@MikeHoltNEC8 ай бұрын
Lol, give a shout out to them for me.
@shaneoakley87578 ай бұрын
@@MikeHoltNEC I sure will!!
@Ariccio12310 ай бұрын
I haven't even watched the whole video yet, I just want to evangelize about the wonders of audible alarm GFCIs - these should be the standard! It's a really user friendly option for everybody!
@Ariccio12311 күн бұрын
Watching this again, I'll add one more thing: there are now apparently also dead front audible alarm GFCIs. Personally, I'm planning on using them to add GFI protection to my lighting circuits, instead of with a GFCI breaker, since it gives me the option of something that will be obvious to even my parents and my sister if they're around and it trips 😂 Someone please let me know when they invent audible alarm breakers - wake me up in the middle of the night if it's when they come on the market
@highwaymen1237 Жыл бұрын
Great video. Watched you're downhill bike video, very impressive.
@MikeHoltNEC Жыл бұрын
Lol... thanks.
@genebowdish.mageniemagic Жыл бұрын
Great explanation of imbalance
@robertseverino8931 Жыл бұрын
Hi Mike! I appreciate you sharing all your knowledge with all of us which has always been of an immense value to me. I have a request for you that’s probably been done in the past, but I’m sure you could make it happen. If possible to transfer all your electrical books ober to Autible or any audio format. If you do have it in this format, please advise or send link. Thank you!
@MikeHoltNEC Жыл бұрын
Send me an email, Mike@MikeHolt.com, and let's discuss this further.
@MikeHoltNEC Жыл бұрын
All of our Products that include Video also include audio streaming.
@bohill1832 Жыл бұрын
According to the NEC, can GFCI outlets be installed in bathrooms 16” above finished floor.
@MikeHoltNEC Жыл бұрын
The required sink receptacle in bathrooms must be installed in accordance with 210.52(C), which would not permit it to be 16" above finished floor. However other receptacles in the bathroom or other rooms in residential or commercial occupancies can be installed at any height, even in the floor.
@harpreetkaur5947 Жыл бұрын
Hello Mike, I have been watching and learning through your vedios for few years now. If possible can you please make a vedio on NEC Article 501. I know you made a vedio few years ago on Hazardous Area Classification. But if you would make a detailed vedio on wiring methods, Conduits, Fittings, Conduit Seals, Enclosures, Termination boxes inside Class 1 Div 1, Class 1 Div 2 areas. What are design considerations at the boundaries of each area. I work in Waste Water Industry, if you could explain using examples from lift station etc that would be great. There are multiple people around me that can use your guidance for a better understanding of Article 501. Also this will touch some topics of NFPA 820. Thanks.
@mikeadler434 Жыл бұрын
👍👍
@davem5392 Жыл бұрын
I would really appreciate with all the commercial restaurant requirements if you could go over function of 3 phase breakers. I think most do not understand this
@MikeHoltNEC Жыл бұрын
? A three-phase breaker functions just like a two-pole or single-pole breaker...
@wuilliamscoa34676 ай бұрын
Think about your answer!
@MikeHoltNEC6 ай бұрын
What?
@zebiosogliani7132 Жыл бұрын
Why not use GFCI break type in the electrical panel instead of the outlet type?
@MikeHoltNEC Жыл бұрын
GFCI is set to trip between 4 - 6 mA, if you used it for the entire house, expect that you'll be losing power often.
@jolyonwelsh98344 ай бұрын
The newer GFCI receptacles now knock themselves out of operation when the protection is lost for whatever reason.
@MikeHoltNEC4 ай бұрын
No, there are multiple options. One option is a sound, a light, or deenergize.
@jolyonwelsh98344 ай бұрын
@@MikeHoltNEC the ones I have seen simply deenergize.
@MikeHoltNEC4 ай бұрын
You must be using Leviton. P&S states "automatic self-test every 3 seconds. If the device ever fails, the indicator light flashes to signal it should be replaced." Now you learned something new.
@jolyonwelsh98344 ай бұрын
@@MikeHoltNEC I use P&S as well. I've never known that they sound an alarm.
@MikeHoltNEC3 ай бұрын
I'm sure it's in their instructions.
@genebowdish.mageniemagic Жыл бұрын
I came up with an idea, imagine a non-contact voltage tester or detector, that is a watch type that you wear on your wrist, when you touch it hot wire, watch detects voltage, transmits signal to cell phone, cell phone transmits signal to disconnect with receiver and disconnects circuit, and or entire sub panel or panel, what do you think about my idea ? Oh, maybe false tripping ? Insulated coil Ring on index finger that detects current through finger, then to watch, cell phone, and trip circuit, sub panel or panel or disconnect with receiver
@MikeHoltNEC Жыл бұрын
Sounds like it's complicated that this watch would know what breaker to turn off. Let me know if you ever get such a device made.
@genebowdish.mageniemagic Жыл бұрын
@@MikeHoltNEC I’m working on it now, not as easy as I thought to detect voltage, current, I am learning about op-amps, I imagine when I figure this part out, the rest will be easy, I am thinking
@MikeHoltNEC Жыл бұрын
Would be nice.
@genebowdish.mageniemagic Жыл бұрын
@@MikeHoltNEC I just posted one of my circuits I was talking about, could be smaller, could be wireless, I have many more ideas on this topic, Gene Bowdish
@Time-Trvlr2 ай бұрын
GFCI, as even with Circuit Breakers; there are Chinese counterfeits carrying printing of CE or other certifications that are not true UL products. Know your distributor rather than seeking more profits and buying cheep products that could potentially harm or kill someone.
@wuilliamscoa34677 ай бұрын
Máster you should translate your books to spanish you going to make a lot of Money!
@MikeHoltNEC7 ай бұрын
My products are based on the National Electrical Code for those living in the US. I feel that to provide a safe installation, the electrical professional needs to speak and read English. So there is no plan to translate any of our products into Spanish. Note: Money doesn't drive me; just electrical safety.
@wuilliamscoa34677 ай бұрын
@@MikeHoltNEC👍🏼
@wuilliamscoa34677 ай бұрын
The nec is translated to spanish, to humble my friend!
@MikeHoltNEC6 ай бұрын
@@wuilliamscoa3467 What does this have to do with your original question and my original response.