GivEnergy AIO combined with an Electric Boiler from Tepeo Electric boiler....

  Рет қаралды 1,760

Mark The Sparky Allison

Mark The Sparky Allison

Күн бұрын

Пікірлер: 23
@neilbissett1240
@neilbissett1240 3 ай бұрын
Fantastic as ever 🤔😎
@BlackCountryLad
@BlackCountryLad 3 ай бұрын
Interesting installation Mark, hoping to bump into you tomorrow.
@liberatodelgreco4430
@liberatodelgreco4430 3 ай бұрын
Very interesting, I do believe there is funding for electric boilers. I did the training years ago on the Tepeo boiler, good alternative if you can’t or don’t want a heat pump. Basically a heat sink very reliable no moving parts and silent.
@daviddawson9099
@daviddawson9099 3 ай бұрын
Looks interesting be good to have some guide to cost of equipment and installation.
@electrician247
@electrician247 3 ай бұрын
way to varied from installation to installation.
@keith8443
@keith8443 3 ай бұрын
If you have an AIO & gateway fitted but not solar or other means of generation fitted, can you export any surplus from the battery to the grid when demand on the grid is high?
@electrician247
@electrician247 3 ай бұрын
yes absolutely
@keith8443
@keith8443 3 ай бұрын
Octopus energy say they need an mcs certificate number but givenery say the AIO is not generating power so does not have an mcs certificate? Where do you go from here?
@electrician247
@electrician247 3 ай бұрын
@@keith8443 speak to your installer it should have a G99 or potentially G98 if you got the 3.68kW AIO. Either way both can and should be notified to MCS. We do that on all solar and/or battery systems. Who installed yours?
@keith8443
@keith8443 3 ай бұрын
@@electrician247 SYNERGY RENEWABLES fitted the system
@keith8443
@keith8443 2 ай бұрын
@@electrician247 Finally got my MCS certificate, just waiting now for Octopus to sort things out. thanks for your help
@Themiddleagedman53
@Themiddleagedman53 2 ай бұрын
Please could you help? Should the gateway on the GivEnergy All in one , EPS be switched on, in the gateway portal? Thanks
@electrician247
@electrician247 2 ай бұрын
Depends if your installer set your system up for island mode.
@Themiddleagedman53
@Themiddleagedman53 2 ай бұрын
@@electrician247 Thank you for responding. My Installer is very experienced like yourself, love the content by the way, excellent. But he/we are having issues with my SMA inverter shutting down with the PE fault encountered on other inverters. Getting help from either company is like pulling teeth, so he is trying to find out the issue. I have watched many of your videos and you seem a genuine person and a good spark. I have seen you comment on the earth fault on other videos. Cheers
@electrician247
@electrician247 2 ай бұрын
@Themiddleagedman53 yes that's an issue to resolve in your SMA inverter. If it's an older varient you will probably be out of luck. Also ensure your installer asked GE to activate the neutral earth bond as that can only be done by them. Installers have no access to it. Sometimes it's due to that. EPS should not be enabled without an earth electrode on the system. your installer will be able to advise on the EPS. It depends how they have configured the setup
@Themiddleagedman53
@Themiddleagedman53 2 ай бұрын
@@electrician247 Thanks I will ask him. No it’s a brand new Sunny boy 4.0 which is picking up everything and sending loads of error codes about everything, when we go into back up mode.He is talking to Give and SMA about things. Thank you very much for trying to help, it is very much appreciated.
@electrician247
@electrician247 2 ай бұрын
@Themiddleagedman53 will be the n-e bond i bet.
@ryanpestell
@ryanpestell 3 ай бұрын
what brand / size is the SWA? looks pretty flexible
@electrician247
@electrician247 3 ай бұрын
The main swa is 25mm 5 core. The smaller cables are H07 not SWA. 6mm
@ryanpestell529
@ryanpestell529 3 ай бұрын
Hi mark, sorry yes the 5 core swa, what manufacturer? It looks pretty flexible for a 5 core 25mm. Great video
@electrician247
@electrician247 3 ай бұрын
@@ryanpestell529 tbh I can't remember but suspect it will be either donny or Cleveland
@M0PAX
@M0PAX 3 ай бұрын
the only thing i dont like with all inverter equipment is all the stuffing glands it makes the install look cheap. Why cant there be a box to cover.
@electrician247
@electrician247 3 ай бұрын
I prefer it tbh. Keeps the engineering on show. To much of wanting to put all the cool stuff in cupboards. Although my plan to put one in the front room didnt pass the wife test sadly.
TWISTED: The dramatic history of twisted-pair Ethernet
28:30
The Serial Port
Рет қаралды 384 М.
Smart Meter Disaster! ⚡️
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 709 М.
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Ultimate Heat Pump Installation. Rip It Out & Start Again!
31:15
Skill Builder
Рет қаралды 131 М.
Giv Energy All in One Battery: Worth the hype?
15:24
Heatable
Рет қаралды 5 М.
Parallel Givenergy All In One
13:37
Evo Renewables
Рет қаралды 1,7 М.
SAVE Thousands - Build your own home solar battery backup!
21:17
Projects With Everyday Dave
Рет қаралды 761 М.
The Perfect Boiler Replacement? Tepeo's Zero Emission Boiler
15:11
Everything Electric Show
Рет қаралды 265 М.
Nearly KILLED by a CRAZY fault! What on earth is going on? 💀
27:12
Artisan Electrics
Рет қаралды 797 М.
Best Solar Setup EVER !!! SigEnergy and Solaredge Combine
22:59
Mark The Sparky Allison
Рет қаралды 2,2 М.
SHOCKED This Heating System NEVER WORKED! Matt's Problem
46:28
plumberparts
Рет қаралды 426 М.
WARNING !!! Solar panels can give you a serious electric shock
29:34
Mark The Sparky Allison
Рет қаралды 9 М.
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН