Napit BS7671 Premature Collapsing of Surface Wiring Systems Regulation to be Applied Retrospectively

  Рет қаралды 3,191

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер: 30
@darryllonghurst4366
@darryllonghurst4366 5 жыл бұрын
As a professional firefighter for 6 years and an electrician I have first hand knowledge of how important this is. I have always used metal fixing in my installs for years for this reason. I would like to add one of the worst is flexible ducting not being supported and collapses like a massive slinky toy, leading to one of the worst entanglements. Good video 👍🏻
@davidwedge1931
@davidwedge1931 5 жыл бұрын
Another very informative video. 👍
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Thanks Gaz and Joe 👍
@drcelectricalservices1026
@drcelectricalservices1026 5 жыл бұрын
good vid thanks, i got the codebreaker book and find it very helpful
@davidclark3603
@davidclark3603 5 жыл бұрын
Well, that’s a bit of a game changer?! Thanks for the info guys!
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Hi David.... a video from the NICEIC coming soooooooon 👍.
@adrianajdelectricals2290
@adrianajdelectricals2290 5 жыл бұрын
Hi guys , thanks for that. This ought to be made clear in the regs don’t you think, since as you say it is such a game changer? The audio at about 4 mins goes off and you can’t hear anything when you are looking round the training boards. Cheers. Adrian
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Adrian the silence is due to a copyright music strike 🤦‍♂️. Couldn’t do anything about it once it went live hence the silence to override my mistake. Thanks for commenting and watching Gaz 👍
@ashleyscott6837
@ashleyscott6837 5 жыл бұрын
What's the other retrospective reg then?
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Hi. Sadly I cannot remember we shoot the video 4 months ago... contact Napit on all the usual social media outlets for the answer.... all the best Gaz
@MrKn1ghts
@MrKn1ghts 5 жыл бұрын
Plastic DB under a timber staircase in a domestic dwelling?
@ashleyscott6837
@ashleyscott6837 5 жыл бұрын
Ccu shouldn't be catching fire after a eicr, well I'd hope not 🤣🤣🤣
@MrSJT
@MrSJT 4 жыл бұрын
Presence of RCD, if it wasn't a requirement at the time say 14th edition and it's sockets on the ground floor then it would be retrospective. If it's in a loft feeding a TV booster then it's potentially a C3. Just like premature collapse would be a C3 unless it could cause entanglement to the fire fighter or escapee which will be C2. The regs are not retrospective, except for the ones that perhaps came out because for example some people have been killed because of it, then when that reg gets applied to an EICR you will likely either call it a C2, or a risk assessment to see if it will be a C3 or C2 such as absence of RCD and absence of appropriate fixings to prevent premature collapse.
@megazeus7972
@megazeus7972 5 жыл бұрын
Richard looks like a hostage being interrogated!
@GSHElectrical
@GSHElectrical 5 жыл бұрын
He was 😁
@doctorelectric470
@doctorelectric470 5 жыл бұрын
great video guys, is there any way you could speak to your Tresham science department & do a test of various metal clips etc? Especially the Stainless steel u nails & stainless steel banding that's available? Cheers
@MrSJT
@MrSJT 4 жыл бұрын
Best Practice Guide 4 (issue 5) is an industry standard and one of the organisations involved who created it is NAPIT... On page 15 it says C3, but would be a C2 if for example an escape route (excluding individual dwellings). So are they saying one thing on video and publishing another on paper??? It could be dangerous to a fire fighter in a single dwelling too!!!
@gd-bq7em
@gd-bq7em 5 жыл бұрын
Do new consumer unit lids have to open upwards or is it ok for them to open downwards thanks
@DC-dp3hk
@DC-dp3hk 3 жыл бұрын
So what is the other retrospective regulation?
@johngrannan
@johngrannan 5 жыл бұрын
Is there any quantitive data you can publish on firefighters being injured/killed by non-supported wiring prematurely collapsing?
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Hi. Sparkyninja has a video (or part video) showing the 8 firefighters that became entangled and died whilst try to save others. Thanks for commenting and watching Gaz.
@johngrannan
@johngrannan 5 жыл бұрын
GSH Electrical TVM
@joey06051988
@joey06051988 5 жыл бұрын
do we need to use metal wall plug as well or a normal plastic one would do?
@UplandsJack
@UplandsJack 5 жыл бұрын
Think if I recall correctly, they are advising NOT to use conventional plastic wall plugs, but rather wall dog screws (like tap con screws) now instead
@UplandsJack
@UplandsJack 5 жыл бұрын
DEWALT Wall Dog Fixings 32mm Screw Pan Head Pozi DFM425005P Chrome - Other brands may be available!
@GSHElectrical
@GSHElectrical 5 жыл бұрын
kzbin.info/aero/PL2Ea5r9gxUUcwnDJOEE_xUoKQAicHlinU The playlist above should help. Thanks Gaz 👍
@michaelagnew7825
@michaelagnew7825 Жыл бұрын
That sofa is a little small
@GSHElectrical
@GSHElectrical Жыл бұрын
Sure was 😂
@johndufton9686
@johndufton9686 5 жыл бұрын
Napit registered sparks near me ignores a lot of the regs. They need to check their guts a bit more closely.
@DC-dp3hk
@DC-dp3hk 3 жыл бұрын
So what is the other retrospective regulation?
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
Что-что Мурсдей говорит? 💭 #симбочка #симба #мурсдей
00:19
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
Collapsed Cables Cost Lives!
14:59
eFIXX
Рет қаралды 13 М.
I'VE BEEN AUDITED! AND I REALLY DISAGREE! - Electrician Life
24:38
Artisan Electrics
Рет қаралды 335 М.
Radial Socket Circuit - Polarity and Continuity Tests
6:47
GSH Electrical
Рет қаралды 4,2 М.
Deepseek R1 Explained by a Retired Microsoft Engineer
10:07
Dave's Garage
Рет қаралды 2,1 МЛН
TI-3000 Panaplex Calculator From 1973
17:51
Fran Blanche
Рет қаралды 3,2 М.
DPC of BS 7671:2018+A3:2024 - NAPIT Explains
12:57
OfficialNAPIT
Рет қаралды 854
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН