Wiring Diagram Lighting Circuit 2 Plate Method Taking the Feed to the Switch 2 Way and Intermediate

  Рет қаралды 56,078

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер: 44
@effervescence5664
@effervescence5664 3 жыл бұрын
I do love watching these, not that I ever do the 2 plate like that. Currently I join the live in the first 2 way switch to the brown carried all the way to the last 2 way, then the feed to the light fittings comes out the common with L1/L2 always as black/grey sleeved. This allows me to carry the 3 core and cpc all the way through the switches without ever having to cut and join the brown conductor. It's always useful and refreshing to be reminded there are other ways of wiring when the need arises though. Great detail and technical know how as always.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks for the detailed and positive comment 👍🦾
@lsnogaming2893
@lsnogaming2893 3 жыл бұрын
Thanks for creating these series of video on wiring diagrams they are very helpful in filling the gaps in my college course 🌟🌟🌟🌟🌟
@no_short_circuit
@no_short_circuit 3 жыл бұрын
Thanks for the video. Always well explained in great detail making it easy to understand.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 👍
@dfjsorbys
@dfjsorbys Жыл бұрын
That is exactly how yo do it! Colours all correct 😂👍🏻 that's how I do it
@eotlati1763
@eotlati1763 3 жыл бұрын
I like your teaching skill. Great job.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks for watching and the nice message 👍🏻
@leebond1837
@leebond1837 3 жыл бұрын
Could you do a video explaining how you would wire 2 way lighting circuits using 2 gang switches (i.e. left switches operates one 2 way circuit, right switches operates another)
@normanhartill1424
@normanhartill1424 Жыл бұрын
We used to call the interconnections "strappers" - have I got old? Also I remember once doing an HMO which had several landings where we shorted out L1 and L2 via a one way switch so the cleaner could temporarily override all switches to "on".
@All-time-learning
@All-time-learning 2 жыл бұрын
Best video explanation ever, you have been very helpful!! I won a bet thanks.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching and the great comment 👍🏻 Gaz
@willbeevor4555
@willbeevor4555 Жыл бұрын
Great vid… At 6 mins 40 sec, can the cable going to the light come from any of the switches? Or only allowed to come from the switch where the feed is entering?
@terencewright2223
@terencewright2223 3 жыл бұрын
Great stuff,thank you very much.
@Dog-whisperer7494
@Dog-whisperer7494 3 жыл бұрын
Very well explained, All though take if the feed to the switch is a throwback to the 50s I prefer to use a junction box and two way switch cable three core twin and earth . But I see the benefits of the two plate method. Fantastic video as always from GSH
@steverobinson8170
@steverobinson8170 3 жыл бұрын
The general consensus in training now is to teach the apprentices to avoid junction boxes if you can because further down the line in testing its not always a component you can either find or visually check .
@JasperJanssen
@JasperJanssen 2 жыл бұрын
@@steverobinson8170 life would be a lot easier if the only junction boxes allowed were wall boxes with a blanking plate, instead of just things stuffed in rando ceiling cavities.
@steverobinson8170
@steverobinson8170 2 жыл бұрын
@@JasperJanssen Problem is domestically customers wouldnt accept that , i wouldnt commercially not such an issue
@JasperJanssen
@JasperJanssen 2 жыл бұрын
@@steverobinson8170 I mean, given that they’re in ceilings or high up against the wall, and blanking plates aren’t necessarily particularly ugly… why not?
@steverobinson8170
@steverobinson8170 2 жыл бұрын
@@JasperJanssen Because blanking plates are ugly , it also allows access to the general public who quite frankly wouldnt have a clue all of a sudden they would be spuring off the wiring adding sockets all to totally unsuitable situations , one i came across a few years back used spur puled of the back of a double socket that had already had spurs wired into it , spurs had spurs attached all in 1.5mm because they couldnt get the bigger wires in , that in itself was bad enough , but they had another bundle cut into that in total 8 cables bodged in the back plus another 4 outside the box in a strip and earth used as common , they wondered why they could smell heat and the breaker kept popping , the less obvious cable junctions are the better . Infact the supply at this shop was so dangerous i pulled the main fuse which disconnected the 3 bedsits above !!! after calling the local supplier
@Dmitrytln
@Dmitrytln 25 күн бұрын
Very unusual. I put hot wire from consumer unit to common terminal in first switch and hot wire from lamp to common terminal in last switch - only grey and black wires used between switches.
@CommonInvesting
@CommonInvesting 3 жыл бұрын
I assume that 2 way (without the intermediate) would work the same, just without the intermediate switch, thanks
@johnbower
@johnbower 2 жыл бұрын
David Brown, Yes you are correct, the intermediate switch gives you the option of switching on or off at three different positions.
@paulneary703
@paulneary703 3 жыл бұрын
so if you had a loop in loop out at the first switch going to all other switches on that floor would all permanent lives be in L1, or wago and then link from wago to L1?
@tonyp2878
@tonyp2878 3 жыл бұрын
How about if you take your feed and switch line to the intermediate switch?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Like this? Wiring Diagram Taking the Feed Through the Switches - AM2, AM2S & AM2E Lighting Circuit Explained kzbin.info/www/bejne/mXqzi5uonqmEqJo
@ramzg5402
@ramzg5402 3 жыл бұрын
Yes of course a lot of help.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 👍
@stuffoflardohfortheloveof
@stuffoflardohfortheloveof 3 жыл бұрын
Brill! 👍
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 👍
@mixer7586
@mixer7586 3 жыл бұрын
Thank you 👍🏼
@henryhudson1984
@henryhudson1984 3 жыл бұрын
Thanks for this. Very easy to follow. Quick question for you. Does it matter which 2 way switch you take the switched line out to the lamp from? I'm assuming not, but just want to confirm.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
U need the neutral from the switch as Henry 👍
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Wiring Diagram Taking the Feed Through the Switches - AM2, AM2S & AM2E Lighting Circuit Explained kzbin.info/www/bejne/mXqzi5uonqmEqJo A different way 👆🏻
@henryhudson1984
@henryhudson1984 3 жыл бұрын
@@GSHElectrical this is the method I was looking for. Thanks for the link. This makes perfect sense. By carrying the supply through each of the 3 switches, I guess it is possible to use the last 2 way switch as the 'link' to send a supply over to another room then? Instead of taking the feed back out of the 1st 2 way switch that the supply came into.
@henryhudson1984
@henryhudson1984 3 жыл бұрын
@GSH Electrical Actually, I have worked it out. This is not possible. The live feed does not make its way to the last 2 way box.
Turn Off the Vacum And Sit Back and Laugh 🤣
00:34
SKITSFUL
Рет қаралды 6 МЛН
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 16 МЛН
The Dangers of Shared Neutrals: How To Avoid Being Shocked
8:45
Electrician U
Рет қаралды 255 М.
Master Wiring: Three-Way Light Switch Made Easy
18:33
ToolBox Talk For Electricians
Рет қаралды 154 М.
Lighting Circuits Part 2 - Wiring Multiple Switches, 2 way and Intermediates
31:06
Two Way Switching Explained - How to wire 2 way light switch
7:05
The Engineering Mindset
Рет қаралды 8 МЛН
Turn Off the Vacum And Sit Back and Laugh 🤣
00:34
SKITSFUL
Рет қаралды 6 МЛН