I'm sorry, I've said it before and I'm going to say it again, you are an amazing plumber. We love watching you perform your knowledge and helping the community get peace of mind in their homes.
@DaveBooth-qs7sw Жыл бұрын
He’s not a plumber as such! He’s a pump installer & a pump serviceman! Plumbers know b all about pumps! Some think they do but it’s a totally diffent trade!
@DaveBooth-qs7sw Жыл бұрын
It’s so nice to see that you have such great pride in your workmanship! Which is lacking in today’s young people!
@Firedog-ny3cq2 жыл бұрын
When I saw that red clay come out of the waterline ditch, I knew you were in Virginia. We're in central Virginia and that red clay is everywhere; hiding just under the surface of the topsoil. I've been waiting a year for my well driller to show up; think I'll give you a call and see how far you are willing to travel to drill a well. I like your attention to detail and how clear you keep your commentary. Your step-by-step description of what you are doing and why is concise and to the point. You don't waste any time with unnecessary chatter and I find your presentation to be easy to listen to and filled with lots of information. Great job.
@markb.1259 Жыл бұрын
9:30- You're right. I'm thinking you should have scrubbed the wall clean before you drilled through!!! LOL
@flgardener11552 жыл бұрын
Don't comments by viewers help the algorithm? I'm definitely impressed by your videos.
@robertnelson47552 жыл бұрын
Look into 3" ID Black Heat Shrink Tube. You could heat shrink both ends as a final cover over all the caulking
@WrenchHead Жыл бұрын
Old comment/video....but don't forget to install the heat shrink prior to assembling the pipe 😂 ...d'oh 😂
@MassiveOverkill2 жыл бұрын
Get a piece of coated wire, bend it over at the outside end (maybe temporarily tape the J-hook in place) and pull on it while you install the inside rubber sleeve ;)
@zenithperigee74422 жыл бұрын
@H2o Mechanic, "Stop thinking what you're probably thinking."😆I was thinking, that is a great idea on using the fernco fittings and the vent collar to act as grommets and a method to help seal & hold the piping in place! It's nice tho that customers can see the care you put into your work by watching these videos! I like the fact that you explain things, offer tips, hey, stop thinking what you're probably thinking!🤣and you even have some appropriate music playing in the background softly so we can still hear you just fine. I think you should easily have a lot more subscribers, you provide good information, obviously know your craft, just overall good videos! I just wondered, with that still being an exterior wall, if code requires you to insulate that portion of the water line. I also don't like those plastic PEX fittings. Some locales here will only accept brass.
@bigal90782 жыл бұрын
Great job, I don't know why the contactor wouldn't install the PVC pipe when they poured the concrete? It would have made your job so much easier. They must have known that water needed to enter the the building. Love you're video, thanks for all you do. Would like to see a video on Jet pumps.
@parker1ray2 жыл бұрын
Pex was not highly used when I was a plumber. We used either PVC, CPVC, copper or galvanized pipe depending on the installation. Schedule 40 was mostly used for residential and schedule 80 for commercial.
@Dingbat2172 жыл бұрын
Good job man, well done! 😛 Now one thing I would do different is to add in a conduit for teh electrical cables all the way to the well head, that way you can simply pull out a faulty cable and snake in a new one if / when it needs replacing in the future without having to rip it all out of the ground again. Any reasons not to use conduit for the electric cables in the ground?
@petedymond Жыл бұрын
Because the wire will basically last forever. No movement. Unless its severed by digging. Running conduit is a waste of $$
@brentpaulus41952 жыл бұрын
Is there a reason why you don't run the same Black PVC Pipe that you use in the well casing?. Then drill your entrance hole for that, then use Bentenite to get your water tight seal? Also when drilling a hole through concrete. Only drill halfway through the exterior wall. Then finish the hole from the inside. That way you'll prevent that Big Blowout. Just wondering?
@MWestern-m4g Жыл бұрын
You are correct about plastic elbows. They suck.
@tompinnef6331 Жыл бұрын
I can tell you are in a 'warmer' part of the country. Here the min depth is 4 ft for trenches. Then we had a few -20F days / nights this year. (worst was a few years back at -28F with chills of -45F or so) Nice seeing how you put in systems there compared to ours around here. Take care , hope the crew / family and you are doing well.
@jimanderson4495 Жыл бұрын
What a Superior job. I think you should have your prospective customers look at these videos. Man….would I like to work for you!
@petersouioui8864 Жыл бұрын
You are very good with the pipe and the hole lmao
@elmersemmel35304 ай бұрын
im impressed with your neat work knoledge
@DaveBooth-qs7sw Жыл бұрын
My your very knowledgeable for such a young man! I’ve always been very interested in well drilling having had many wells & bores drilled for many of my customers! But none were drilled& cased with PVC pipe like you do in your country! Here in New Zealand without ground strata being mostly volcanic thick walled steep pipe is used because of likely cave ins! Beneath our ground surfaces are often a grey papa like substance that can be either soft or hard! Very hard like concrete! That can take someone with a heavy sharp spade to dig down 6 inches square hole & can take a human more than one hour to get six inches deep! Almost impossible to dig a-post hole in solid papa! So imagine trying to bore a well or bore going through this material! With that being said a bore hole being cased in PVC would collapse over time with current earth quakes that this country often has being on the ring of fire. That’s why most bores are cased with thick walled steel pipe! But I am truly impressed with your skills & thorough workmanship young man! Every time I watch one of your videos it always brings back fond memories watching my friend drilling holes & bores for my clients! Thank you so much!
@charlesweihe4346 Жыл бұрын
You are lucky we have to use pittless adaptors and at 7 to 7.5 feet good old Montana. I have been doing this for 30 years and I enjoy you programs.
@webbac84912 жыл бұрын
Here in the UK, our building and electrical regulations (codes) are so much stricter. Another professional job and great video!
@taylorsutherland6973 Жыл бұрын
What is different in the UK? How would this job be done there?
@Mr424242424242424242 Жыл бұрын
Dude, you're allowed to use ring mains in the UK. Your electrical codes are a straight up joke.
@paulcoulter71812 жыл бұрын
I’ve been using NP1 for years. It’s a awesome sealant.
@sissymurphy9620 Жыл бұрын
The real thing is he is a well guy who knows what he is doing and willing to share and help others . He has been the biggest source of info I have seen any where and the biggest help to me . I will be buying a new pressure tank regulator from him . I see his online store has them and BEST NEWS EVER THEY ARE AMERICAN MADE
@harescrambled2 жыл бұрын
Nice looking work. In Ohio, we also must have a sample port for raw water. Ours are either on the tank tee or in the piping ahead of any conditioning/treatment equipment, since we have pitless adapters everywhere. Thanks for sharing 👍
@petermccall93545 ай бұрын
Hi H20, just thought i let you know to smooth of any caulking compound just get soapy water instead of spit it won't harm the caulking, cheers Peter
@jacklabloom6352 жыл бұрын
Good job.
@USSBB622 жыл бұрын
Learning so much. Prepares me for my Well to 5K storage tank and back to Shop new installation on the Farm. Thanks so much.
@esmaponda Жыл бұрын
9:30 you are the one who was thinking that .... 😂😂
@Keith_Mikell Жыл бұрын
Much love phil. youre an amazing person.
@yellowlab5624 Жыл бұрын
Great work ethics 👍👍
@twin40dave Жыл бұрын
Nice job 👏, in the UK that concrete wall wouldn't make code underground, it would have to be tanked and lined ,
@taylorsutherland6973 Жыл бұрын
Same here in the northern US. They have such a mild climate in the south US their codes are much more less restricted.
@twin40dave Жыл бұрын
@Taylor Sutherland wow, but surely it most let damp through eventually but hey if it meets code who's to argue 😉
@craigbb91772 жыл бұрын
Another great video. I keep learning. and learning.
@straight_to_finish Жыл бұрын
I was just about the ask about the lack of pitiless adapters before you briefly talked about it. The test port can be extended up from the pitless adapter via a hydrant type valve that will drain the water into the ground when closed. With the freezing temperature disaster in Texas and crazy weather patterns, it might be time to reconsider.
@hornetboy36942 жыл бұрын
Awesome video thank you
@joopterwijn Жыл бұрын
Do you provide a drawing of the layout external pipe and wires? For example in reference to the house corner…
@ThatGuyFromArizona2 жыл бұрын
You do very clean work.
@curtismuma19312 жыл бұрын
Nice work bud 👍
@EdChilds-nu6vf5 ай бұрын
You need to add the wall insulation back in the wall cavity
@jimgrimes8182 жыл бұрын
Pro Job
@ryankennedy94142 жыл бұрын
Doing this for a living and seeing how it gets done in other places is mind blowing. I cannot imagine ever using PVC underground. It must work but the idea of joints underground is crazy. We have 4' of frost here though, so the pipes have much more movement. We use 100lb poly with no joints save at the house and well. Also two wire pumps and non union tank, especially when using glued PVC in. Tank swaps must be fun.
@QuantumMind88 Жыл бұрын
How deep do you bury your poly pipe?
@MWestern-m4g Жыл бұрын
Exactly. No PVC, I ran 1500 ' of 1 1/2' HDPE Polyethylene Pipe. Wall thickness was .173. And it was/is Blue (even better). Flexible and rugged.
@crabmansteve6844 Жыл бұрын
Almost everyone here in the South used PVC underground. We don't have many more than 3-5 weeks spent below freezing during winter, and the days are spread out and not continuous. You should see Australian plumbing, a lot of it is left ABOVE grade, that blew my mind even being from the deep south. Lol
@MWestern-m4g Жыл бұрын
@@crabmansteve6844 Australia?? You ever watch them run service to a house in a Third World Country? One wire- they use dirt for the return path.Unbelievable. I live in the Midwest. A plumber (50+) told me never glue a fitting that's underground and if you use o-ring snap joints built concrete supports at each end to keep the pipes from spreading apart over time. Above ground is easier to repair when/not if it breaks.
@clicknstack1398 Жыл бұрын
Thank you.
@daviddavis7855 Жыл бұрын
Would it be a better installation if the pump wiring used a separate waterproof entrance to the house? This would assure a better seal around the pipe?
@swedenfrommycam Жыл бұрын
Beautiful 🏆
@rlb9121 Жыл бұрын
My favorite channel of all, your videos are the best. I'm a retired plumber, (38 yrs), down here in Texas, I also ran a water company, and plumbing/well supply store all in one. You're very good at your job, but I can also tell someone with plenty years on their belt taught you all the old tricks, like never laying a fitting down under stress, backfilling pipe in place before finishing the fittings, spitting on that NP1 to smooth it out. You said you would always go with a PVC male into a PEX female for crack resistance, I'm the opposite, I'll go with a sch. 40 female and male PEX fitting, some Rectorseal #5, and just don't torgue it down like a cap bolt.😁 I see it's mostly bladder tanks where you are, down here it's mostly galv. pressure tanks. I've done thousands of service calls on topside well work, , , air volume controls, check valves, Schrader valves, pressure switches, (ants in pressure switches). Here in Texas you're supposed to have a Pump Installers license to pull a pump, (any work in the hole), so we always contracted that. I think your viewers might be interested in learning how a pressure tank set-up is different from bladder tank set-up, anyway, I'll shut up, but again your channel is the best.
@dangda-ww7de Жыл бұрын
Laying a fitting down under stress will get you a service call a few year later, more work.
@69druth2 жыл бұрын
Curious why you use rigid pipe instead of poly tube for the whole system.
@tommyjohnson5845 Жыл бұрын
Man that looks like a pain in the ass to do all that and messy caulk..we use a bag of bentonite and make a dough ball and throw some more dry on it before backfilling. Never once had a leak. Looks to add about an hour to the job and I've not had any luck in the past with your way. If it works thats awesome man.
@petenikolic52442 жыл бұрын
If you want to be pedantic about holes in walls from out to in the in side should always be above outside helps prevent water running in .
@h2omechanic2 жыл бұрын
How does that exposed pipe not freeze? Also, 90% of people plant bushes around the house, I need to be deep enough to prevent anyone from hitting it accidentally.
@petenikolic52442 жыл бұрын
@@h2omechanic it can all still be underground but rill from the inside out on a slight down ward direction an inch or so is enough just to stop water creep
@IsaacTourscom2 жыл бұрын
Keep up the good work, love the hard work
@chrismylonas7642 жыл бұрын
Your electrical cable outside in the dirt,was that placed in conduit? .
@wills22622 жыл бұрын
it's likely UF-B
@bradthomaspix2 жыл бұрын
Just did whole house w/new tank and plumb. came out great. A week later my 15 year old pump died. lol. So wondering if I can increase hp 1/2 to 1hp @ 20gpm? You have the best video and the walk through on pump replace and install was the best . Thanks and I will $ you at first of the month. ty
@joshcamillehenricks8505 Жыл бұрын
What about backflow prevention? Does your area not require a duel check valve and vacuum breakers ?
@rcmechanialgroup2856 Жыл бұрын
Nice work. What size well tank did you install?
@robertschroeder1978 Жыл бұрын
Great video and I have enjoyed very much the wealth of information. I am confused on something though. If the well is 165 feet deep why was the pump lowered only to 60 feet? I'm sure there is a good reason just seems like a lot of depth not used though.
@h2omechanic Жыл бұрын
If the static water level is high end in the well, there's no need to set the pump deep. In this case, it keeps the pump inside the pvc casing and drastically reduces sediment issues
@junkmail1262 Жыл бұрын
That’s all great but the home owner paid to have the well drilled down 165’? I just got a quote to have a well drilled. Anything over 100’ is $40 a foot’. That’s another $2,600 in Ohio!
@arshooter12 жыл бұрын
Hello neighbor, I see you are in VA.
@madhatmassarani62 жыл бұрын
Well done, professional and ethical as no short cuts. How can I get hold of you as I need your service.
@Firedog-ny3cq2 жыл бұрын
His phone number is on the metal well tag that is attached to the well casing. It is shown on camera toward the end of the video; I'm calling him, too!
@hyper-12 жыл бұрын
Did u drill the well also?
@mikemmikem2758 Жыл бұрын
Always good to use a brass female....
@BIHaole Жыл бұрын
A issue I noticed was where the pipes were notched into the top plates. It appeared as though the notches weren’t deep enough and nail protection plates would not be able to be installed. I’ll assume that the pipes will be insulated. One suggestion I’d make is that you lay some metallic identification tape a foot above your pipe prior to burying it. You never know what future projects might involve excavation.
@h2omechanic Жыл бұрын
I couldn't cut the notches any deeper (in the basement I assume you mean) behind the notch/foam was the superior wall (cement) . Unfortunately little planning goes into design when it comes to the incoming water line. Must do the best you can & make the inspector happy.
@johncass24412 жыл бұрын
Did any of the removed Styrofoam get put back?
@AlbertCovelli2 жыл бұрын
Awesome
@tommyjohnson5845 Жыл бұрын
Just a quick other question while im here. Why on earth are you not burying poly pipe? Just curious thanks
@dmills13F Жыл бұрын
Plumbers use plastic pex fittings on well systems. We see a lot of dezincification in brass pex fittings on well water. It's probably happening to your well brass fittings too, but since they are larger than your average pex fitting it takes longer to show up.
@NeogenicOrg2 жыл бұрын
Dumb question how do you schedule 80 elbows? Glad you have his channel the recent freeze that hit Texas froze our wellhouse an house piping. Lots good pointers here I'm going to get to put a use probably this weekend thank you for your videos Man.
@h2omechanic2 жыл бұрын
They are special order item from my distributor. Not truly necessary, but added protection.
@jameslyons1661 Жыл бұрын
❤
@chrismiles13692 жыл бұрын
@25:20 would a hydrant work for a sample port if you had a pitless adaptor?
@h2omechanic2 жыл бұрын
Yes
@willaimphilippe1524 Жыл бұрын
Or ceiling around walls dry bentonite cover bag or more nothing will get through then submit the inside powder of that note
@njplumbing8 ай бұрын
I'm buying property with a well that hasn't been used in 20+ years. I saw the pit, it has a few feet of water and a floating pressure tank in it. I'm guessing the well was drilled 50+ years ago. Do you think the well casing is still good? Do you think there is a rating plate someplace with the well data on it? The property is next to farmers fields. Whats the best tests to do to the water. Oh, it's in Pennsylvania. Love your videos and that your so anal, the steps you take to get the job done is the same way I work.
@jayhartigan9469 ай бұрын
Why didn’t you hold the interior entrance ell closer to the inside so the drywall would fit over the studs, top and bottom. It looks like your pipe is going to interfere with the drywall installation.
@johncuervo30192 жыл бұрын
It is awesome that you own a excavator but a trencher is ten times faster. Do yall own both? I only skipped through video so I apologize if I'm asking something you've already answered. Also what do you cut the casing with? It's a really clean, smooth cut
@Hi.Im.Chucky2 жыл бұрын
Where in VA are you at? I'm here in N. VA and my well pumps discolored water after it rains. Gotta wait a couple of days for it to go back to normal.
@h2omechanic2 жыл бұрын
Watch my Muddy water videos on installing well liners. Your casing pipe is leaking in the rain water.
@lornefishbc4 ай бұрын
Why didn't you install the pipe inside the wall more? Looks like it is on the outside...
@madmatt20244 ай бұрын
The only thing I don't understand is why you switched back to PVC for connecting to the pressure tank. I would have ran PEX directly to the pressure tank. It would have had one less union and matched the plumbing that was already in the utility room.
@russellstclair95262 жыл бұрын
i can not find the part to fix my well any where its called at the well control please help me find one
@h2omechanic2 жыл бұрын
I'll need more specifics. Hwdracing@gmail.com
@danielhepp5412 жыл бұрын
What about frost depth? or is freezing not a problem at that site? one place my landlord had a minimal trench depth and just got some heat tape sort of a lame job.
@h2omechanic2 жыл бұрын
It's about 8" here. Not bad. Our pipe depth is required 18". We normally put it 24" deep.
@perrymelton1586 Жыл бұрын
Where in Virginia do you live at
@Maxsell96 Жыл бұрын
метр дома под землей?
@embreeja Жыл бұрын
This is months after you posted this but....... It looks like you put solid PVC directly from the buried lines to the wellhead. No clamps, no flex. So how would you ever pull the pump? (cut the PVC?). I hope I missed something.....
@rodgraff17822 жыл бұрын
Don’t you have to pour a concrete collar around that well casing? That’s a clean looking job.
@tomferrin11482 жыл бұрын
I'm curious about the flexible electrical conduit you used at the pressure tank. It looks like Ultratite Flexible PVC Conduit, but what fittings did you use on the ends? Did you just use cement where the flex conduit enters the solid PVC riser conduit? And what fitting is on the pressure switch end? I really like the approach you used where the water pipe and pump cable penetrates the foundation! Great waterproofing. Even though it's not that far below ground level, water often flows between the outer foundation wall and the nearby earth and could easily lead to leaks into the basement. Your technique really looks like it would stop that. Very nice!!!
@danielkelley74222 жыл бұрын
Do you guys normally not install a check valve in the incoming line to the pressure tank?
@h2omechanic2 жыл бұрын
No. Never. It prevents pressure from pushing against the pumps check valve. If it was one near the tank & the pumps check didn't seal 100% then you'd get air in the water line's.
@billstreeter4716 Жыл бұрын
Link seal!
@unclebill5170 Жыл бұрын
I would be worried about them doing hard wood and putting a nail in the pip where it elbowed above the ceiling
@rayclark89202 жыл бұрын
Why didn’t you go through the seal instead of on the outside of the wall? It appears in the video. It’s going to be Very difficult to finish.
@kllisk2 жыл бұрын
Where do the elecrons get introduced to make this work ?
@paulungrey68262 жыл бұрын
I do believe they make special termination fittings for passing through concrete. Much cleaner. But you do what works. That pcv to pex transition scares me. I would of run uponor pex all the way to the well head. It's illegal to use pvc for water distribution in a home in Michigan. If it passes inspection, go for it.
@mforrest852 жыл бұрын
How did you know what I was thinking?
@LADYMONA Жыл бұрын
Superior work on superior wall.
@JoePublic717 Жыл бұрын
I can't believe the builder didn't waterproof the foundation.
@parker1ray2 жыл бұрын
I used to install and service huge systems in factories, hospitals, institutional installations, and Government facilities like Oak Ridge Tennessee, Rockwell International, General Mills, and University of Tennessee. The biggest water softeners that I maintained were 40' trailers of which there were four running 24/7 at Alcoa Aluminum in Alcoa, Tennessee. I also installed and maintained thousand of residential systems. I was bitten working in a crawl space and spent ten days in ICU and lost my job because the company said they could not hold my job for the two months that I was bed ridden and recuperating. One week before i was bitten I received a employee of the year award! Tennessee is a right to work state and this means that The employer has a right to work you to death. Should have been a professional welfare recipient LOL!
@Hear-MeoutTwo22 жыл бұрын
Workman compensation???
@SovaKlr2 жыл бұрын
I friggin knew that was Justin...
@DaveBooth-qs7sw4 ай бұрын
I’m impressed with your workmanship but I’m wondering why you always seem to use 90 degree PVC elbows, why not 45 degree elbows as there is less friction loss using 45’s than 90 elbows besides water flows easier through a 45 elbow than it does a 90 degree elbow! Plus there is a lot less stress on the pipe work under ground!
@timkirkpatrick91552 жыл бұрын
While I follow your logic in the wire placement. right angle bends in wire are discouraged. A gentle curve avoids thermal stressing and fatigue.
@Vaticider69 Жыл бұрын
Most homeowners don't care if you go the extra mile until things fail..... then their all about the details....
@buggyduggy24312 жыл бұрын
I lived where they said it never freezes here, Then it froze and pipes broke everywhere. Cost people a lot of money and aggravation. Some people didn't get water for 3 days. Medioker work at best.
@andrew-cm3zn2 ай бұрын
We never come outside the inside wall as this will not pass the inspection
@russellstclair95262 жыл бұрын
you come here and take avideo of my old 60 yr old stuff pump
@russellstclair95262 жыл бұрын
thank you
@vegasfordguy Жыл бұрын
I'm surprised that you can use PVC inside the home. PVC is illegal to use around here on the interior of the home since it releases harmful chemicals in a fire. Why do you use PVC at the well? It can't resist freezing and cracks extremely easy. Pex is much more resilient. I'm not saying you're doing anything wrong, just can't believe it's allowed in your area.
@sissymurphy9620 Жыл бұрын
OK bought my pressure tank switch and would love that you would carry the pressure gage .and also a 40 gallon pressure tank .I had to buy one of those terrible square D garbage ones that never last because my pressure switch when taking it off was all clogged up with stuff from my well , cleaned it but it did not work so was forced to buy the square D one that I hate, but bought yours because I know this one will not last a year , they never do NEVER DO They corrode away . I got your 40/60 switch which is what I had
@h2omechanic Жыл бұрын
Thank you! I'll have your order sent out this morning
@thetruth8958 Жыл бұрын
please follow the code.
@dallas695 ай бұрын
No To many failure points Putting in windows doors and even on roof vents do not use that glue or clamps and and and Fix Just do the wall punch hole\\ Put in expaning foam on the pipe and the hole Let the foam expand and cure done May be just maybe coat the out side with a sealer but that is no nessary due to the un drilled wall is not sealed/ Over kill and way way to many failure points. and Glue failue is the worst point of all that work.
@dominicchaize1112 Жыл бұрын
Electric wire goes in its own separate pipe, not straight in the ground. How in hell is anybody going to change it in case of problems. Very poor work.
@tommyjohnson5845 Жыл бұрын
Umm you don't change the wire by putting it through the same hole.. you just pop another hole if the wire goes bad shallower..