Just a tip. Turn off the recirculation system on your a/c when charging, allowing only outside air to flow through the evaporator, which will give you the true pressure readings on your manifold gauges.
@marlu6373
@marlu6373 3 ай бұрын
good tip man
@johnflanagan6729
@johnflanagan6729 2 ай бұрын
Never heard this one before. Makes sense great to know
@megaman4201
@megaman4201 Ай бұрын
And give you the correct temp reading, you're cooling the outside air temp not the inside cooler air.
@slipstreamvids7422
@slipstreamvids7422 Ай бұрын
Since the compressor speed varies with vehicle speed unlike home hvac, it’s reasonable to assume the pressures increase while driving. This makes it kind of Kentucky windage to get the proper AVERAGE amount of refrigerant in the system for all ambient temps and speeds, without over or underfilling it just sitting static in the driveway. The thermometer in the vent becomes the most valuble indicator
@gunlover1955
@gunlover1955 Ай бұрын
Turn off the recirculation system on your a/c this is the right way to do it you need to use the outside air temperature to add the correct amount unless you recover and recharge by weight!
@aidenstefanson2175
@aidenstefanson2175 Жыл бұрын
As an air conditioning mechanic, I think you did a really good job. I don't know what laws are in the united states, so bear with me. In Canada, you need a license to purchase real refrigerant. The stuff we can buy at a parts store, isn't "real" r134a, but a hydrocarbon cocktail (propane, isobutane, etc.) that works in r134a systems. The catch, is that the weight of the charge and system pressures are very different. The products I'm familiar with require only 40% of the systems listed weight. This leads a lot of people to overcharge their systems, which prevents the ac from cooling at all. Its actually better to under charge than to overcharge. Pressure is great for diagnosing issues, but not great for charging.
@1RoadGarage
@1RoadGarage Жыл бұрын
Thanks, that’s interesting.
@TotalWarriorLegends
@TotalWarriorLegends Жыл бұрын
​@@1RoadGarageyou didn't show and open only the low pressure, blue doo. You didn't open the valve on the gauge red one, high pressure. Why you didn't do that?
@shawnvanderdoes9823
@shawnvanderdoes9823 Жыл бұрын
In the US to purchase large quantities of refrigerate you need an EPA license. The small cans anyone can purchase.
@aidenstefanson2175
@aidenstefanson2175 Жыл бұрын
@@shawnvanderdoes9823 that sounds really convenient for home mechanics who want to do it right
@jeepinintexas6215
@jeepinintexas6215 Жыл бұрын
Lol, you will know if you overcharged it. You will find oil from that AC system leaking from your AC line seals/o-rings. Then you will need to go have the system serviced lol.
@markymark5281
@markymark5281 Жыл бұрын
You were soooo close! Your pressures are good, which is why it is cold air when driving around. Hook your gauges back up like you did, then raise your RPM's to 2000-2500, and watch your pressures while doing that. You'll sleep better knowing your pressures now maych the chart. They'll drop back down when your rpm's.go down.
@1RoadGarage
@1RoadGarage Жыл бұрын
Thank you!
@Theferg1
@Theferg1 Жыл бұрын
@@raularteagagavia2835 the wheel as your AC system cycles on and off it’s supposed to.
@connorwallace9643
@connorwallace9643 3 ай бұрын
Why did he need two cans if it didn't change that much pressure wise ? When do you open high side valve . I don't think I saw him open it. When do you open yellow side valve
@traviskelly7082
@traviskelly7082 3 ай бұрын
@@connorwallace9643 You normally don't open your high side on MVAC , you just use the gauge for problem solving. As far as where your pressures should be you can look it up online and all it tells you is the weight from the factory and if your using a 30lb tank and scales you can just drop that weight in HOWEVER if I have to use small cans I normally go by Ambiant temp 82 to 90 outside and my temp gauge in the vent should be at a idling vehicle 39 to 44 is what I like but you will see some systems at 48 50 and it be 95 to 100 outside. Once I get pressure where I want per temp, I drive the car around while looking at the temp gauge. Long as temp is stable its good. Go by these steps and your good. Hés correct about a vacuum but you can vac it down normally 10 to 12 min then add freon, if you have a leak , pull your high side service valve out and using an injector add your oil and dye, reinstall with new service port valve-replace low side to, pull vac only on low side this is so you don't suck all you dye out, vac 12 min, dump freon in. I know long comment, but i love doing this stuff, I got license through MACS and opened up my side business at my house. I have been doing this for years and I have learned a lot My first 3 years I had a 40 year vet I could ask question to. Been on my own 5
@fatbastardwithabeard
@fatbastardwithabeard 3 ай бұрын
@@traviskelly7082 good info, thank you
@bluemax229
@bluemax229 6 ай бұрын
I sometimes get myself in trouble when I criticize KZbin posters, pointing out mistakes and things that they left out? But you need not worry, because your video is the most complete AC recharging video I have watched in the past few days! You showed all the steps. Please take this compliment, as I don't give very many!
@kevins5268
@kevins5268 3 ай бұрын
Lol tool
@rvh77
@rvh77 Ай бұрын
Wow! What an honor! I mean, coming from you and all 😂
@brittanywright9646
@brittanywright9646 Ай бұрын
That was very noble of you. However, this is the one time you should've opened your mouth. Instead you let this youtuber get away with doing a completely wrong ac recharge. As you know, the ac is a closed system, meaning the amount of refrigerant in the system is what will be there indefinitely unless there's a leak. A low charge in the system after having no issues means exactly that. The first would've been to evacuate the system and pull a vacuum on the system. Since it's obvious there is a leak, the next step is to find it. My method would be to let the system pull in about 50 psi of r152a and then spray soapy water on each connection point. Once the leak is fixed then vacuum system down again, more r152a, then recheck. If no more leaks, then a final vacuum for about 45 mins to be sure all moisture is out of system, and then recharge with your refrigerant of choice ( just make sure it's compatible with the oil in the system). *mic drop*
@danroth3962
@danroth3962 Ай бұрын
@@brittanywright9646 what the hell is r152a??
@brittanywright9646
@brittanywright9646 Ай бұрын
@@danroth3962 it's a refrigerant. Same as r134, but better.
@j.r.branch1681
@j.r.branch1681 Жыл бұрын
I have been a HVAC service tech for 25 yrs the only thing I see is normal we put the straight end of the hose to the manifold and the curved end to the adapter for the service port but it works either way great job over all brother also if u idle the motor up to 1500 RPMS than set it at 42 to 44 and it should be good cause going down the road the engine is at 1500 RPMS and air moving across the condenser coil so always idle the motor up to 1500 then set the charge cause those pressures are for 1500 RPMS they will be lower at idle that’s why they look low
@kmlumd44
@kmlumd44 4 ай бұрын
Can you fill an AC system using the gauges instead of using the specified quantity of R134 under the hood?? Is he saying it doesn't matter if you disregard the specified quantity? Cause I got a car that isn't blowing super cold, but the system is sealed still after 20 years, and I was gonna evacuate the system before filling it so that way the quanitty is correct... But based on this guy's logic I can just see what the gauges are at and add however I see fit as long as the guages are in spec.
@UNUSINC
@UNUSINC 3 ай бұрын
@@kmlumd44it’s better to fill it with the amount labeled on the car. Using the pressure chart isn’t the best way to do it. Evacuate the refrigerant and see how much is weighs for science. Then fill it back to the right amount labeled in the hood of your car
@d46512
@d46512 3 ай бұрын
Oddly, the instructions showed the hoses installed backward. Easy to flip if your underhood space warrants it
@tsl7881
@tsl7881 3 ай бұрын
Thanks for this info. I started to worry because I thought I had been putting it in backwards for the last 15yr.
@Tubeagrutis
@Tubeagrutis Ай бұрын
Your video helped me fix my kids AC! Now I have some tools, knowledge, and experience to tackle future AC problems on any car. All due to you!!! Thank you very much for your *entertainment* vid!!!
@acidreign0911
@acidreign0911 Жыл бұрын
Many have said this, normally what I do is purge my high side while the engine is off by cracking the red knob just a tiny bit then closing it. You leave the yellow hose disconnected. then i repeat with the process with the low side with the engine on. Then do what your purge process. During the recharge, i use a thermometer to measure the temp on the condenser near the inlet side and compare it to the temp on the high side gage. Try to get the temp on the guage to match the temp at the condenser inlet without going over. Once these are close, usually within 10 to 15 degrees, your system is full. You will note the suction line on your compressor should be condensating. This means there is cool liquid refrigerant making its way back to the compressor to help keep it cool and lubricated. Its always worked for me and kept me cool in the Florida heat. Charge volume specs never actually tune your ac system because each system is different, and it's volume capacity depends on not only manufacturing accuracy but also elevation and ambient barometric pressure. Hence a system charged in denver would need slightly less freon than a system charged in New Orleans. Always go by condenser temp to prevent overcharging.
@carltonshore8843
@carltonshore8843 3 ай бұрын
The refrigerant going to the compressor should be vaporized or the compressor can lock up
@acidreign0911
@acidreign0911 3 ай бұрын
@@carltonshore8843 not completely, if the refrigerant is completely vaporized, you drop cooling capacity. Vaporization is dependent on temperature. If the lines aren't sweating and back to the compressor, you don't have enough refrigerant
@bertramlrezenet9311
@bertramlrezenet9311 3 ай бұрын
Just an observation, keep in mind, the compressor is supposed to pump Freon in the gas state.
@lees5402
@lees5402 Ай бұрын
I have watched a lot of these. You literally are the only video that is specific on what valves should be open and what are closed. Thank-You!
@perkinatorfpv5553
@perkinatorfpv5553 3 ай бұрын
if you were 24 ounces low on refrigerant then you have a leak somewhere. I would like to have seen you take it down to vacuum, say, 500-540 microns, and let it hold there to watch any decay in pressure over about 15 minutes time. Then you could have just recharged it to factory charge. Other than that, nicely done. I'm happy to see you purged air out of the lines before putting it in the system. So many people forget that step. When I do AC for myself and friends or whomever, I always put a blower fan up to the rad/condenser to simulate some driving. thumbs up!
@SteamTrain2639
@SteamTrain2639 Ай бұрын
How do you pull a vaccuum on it if it has refrigerant still in the system?
@cliffhaskett7703
@cliffhaskett7703 2 ай бұрын
Positioning a shop fan (24",36",Etc. drum type) in front of the grille blowing air into the condenser will simulate A/C performance while going down the road. Watch the gauges and see the pressures drop. While you're at it , it wouldn't hurt to flush the condenser out with a water hose if accessible. From the inside (engine side) out. Not internally flush , but externally.
@jimsix9929
@jimsix9929 4 ай бұрын
I am a pro mechanic and I think you did a fine job yes you will need better stuff to do it for a living but you did nothing wrong good job guy!!!!
@1RoadGarage
@1RoadGarage 4 ай бұрын
Thanks!
@LastTrump7
@LastTrump7 2 ай бұрын
@@1RoadGarage How did the AC do a month later? Did you have any leaks?
@isettech
@isettech Жыл бұрын
If you follow this video, it shows how to introduce non-condensables into a system. Yes, air in the hoses at 0 PSI is air at 1 ATM pressure. In the USA, to work on automotive AC systems, an EPA 609 certificate is required. Purged the refrigerant line, but not the high and low side lines. One out of 3. OK. To vent much less refrigerant to the atmosphere, opening the can valve, then closing it will squeeze the air and partially replace it in the hose, then with the can valve closed, purge at the manifold. The refrigerant in the line then expands and expels the air. No need for inverting the can for this step. Gas pressure alone is enough to purge the line. Same applies to the vehicle lines. Open the high and low side connector valves and close them, then release the pressure at the manifold. The expanding refrigerant will purge the hoses. Do this with the engine off, so the low side has more than 15 PSI to compress the air in the hose, then expell the air as the refrigerant expands as the pressure in the hose is released. Keep air out of the car AC system. It can't turn into a liquid and thus reduces efficiency and capacity. Save the environment by venting as little refrigerant as possible. Don't flow refrigerant to the atmosphere by venting it as shown in this video. Might take a look to see where the sight glass is on the vehicle AC system. Learn how to use the sight glass in addition to your gauges for charging. Remember, if you have non-condensable gas in your system, the sight glass will always have bubbles. Only a system without air in it will be able to fully condense the refrigerant into liquid to be seen as no bubble liquid in the sight glass.
10 ай бұрын
I understand that the refrigerant must be charged through the low pressure line in gas form and through the high pressure line in liquid form. It is not good to charge liquid through the low pressure line. Is that so?
@isettech
@isettech 10 ай бұрын
@ You can charge through the high side, but only after the system has been repaired and under vacuum. Liquid can be charged by weight into the high side. If you try to put liquid or gas into the high side, the tank being lower pressure will pump out the refrigerant into the tank possibly over filling it and making an explosion hazard. Some refrigerants are required to be added as a liquid, as blended refrigerants can be distilled by boiling off the higher vapor component first, which destroys the refrigerant glide. Look up blended refrigerants for more info.
@CWK090
@CWK090 7 ай бұрын
@isettech Reference ”In the USA, to work on automotive AC systems, an EPA 609 certificate is required” That statement is true ONLY IF you are being compensated ($ or bartering). “Any person who repairs or services a motor vehicle air conditioning (MVAC) system for consideration (payment or bartering) must be properly trained and certified under section 609 of the Clean Air Act by an EPA-approved program.”
7 ай бұрын
@@CWK090 This is one of the many things that make me happy to live in the developing world, definitely the "free" world is not free at all, everything regulated, everything normed, everything limited, everything controlled.
@brianmock551
@brianmock551 6 ай бұрын
And it is beyond you to comprehend why?
@Theferg1
@Theferg1 Жыл бұрын
Great video and info bro!! Hey the only thing that I would like to add is when you screw the fittings down onto your AC lines don’t screw them down all the way because they are known to break the Schrader valve that’s in your AC line so basically screw it down until you see the gauge move and maybe just a little bit turn past that and that should be good. Hope this helps.👍💯
@DrHavok1
@DrHavok1 5 ай бұрын
nice bit of advice sir thank you
@jimsix9929
@jimsix9929 4 ай бұрын
good advice, you only need to open it, any more will damage the fitting thank you!!!!
@cup_and_cone
@cup_and_cone Жыл бұрын
It's nice to see others take on something new to them. My opinion is just run it until it starts blowing warm again, otherwise you're throwing money away! If it's lasted 28 years so far, it'll probably be fine for at least several more years with the top off provided you didn't overcharge the system and hurt the compressor. If it is leaking anywhere, it's probably leaking at the service ports and compressor seals...could try soapy water and see if you get any bubbles to avoid having to add dye, but it's probably not a big deal if it has lasted this long. Just run it until it becomes intolerable before going down the rabbit hole of parts replacement.
@headhoncho4890
@headhoncho4890 Жыл бұрын
I just rebuilt my entire ac system l most anyway after recharging twice only to not have ac afterwards. Third time was a charm thang god. Cold ac is a blessing
@beesknees6970
@beesknees6970 Ай бұрын
wow maybe that's what I need to do. I've replaced my evaporator/condenser, compressor and it still struggles to get cold on hot days. It used to freeze us out! The dealership purged and refilled it because they can't figure it out. It got slightly better but still not cold. So maybe a third time will help! I'm thinking that there is some crud in the lines somewhere....
@gordonpotts753
@gordonpotts753 3 ай бұрын
U did pretty good, accept for a few things. 1. U should purge all the hoses. 2. Chevy typically have a back pressure regulator set for 28 psi. So no matter how much freon U sucked in the back pressure will always b 28 psi. U should always charge an A / C system by weight or temp, not by pressure.
@northwestrepair
@northwestrepair 3 ай бұрын
What do you mean by weight or by temp ? Please clarify in detail.
@user-nr2xp4ss9n
@user-nr2xp4ss9n 3 ай бұрын
@@northwestrepair with a refrigerant scale or by ambient temperature
@bones1225
@bones1225 2 ай бұрын
100 percent correct. You can only get the best reading on your gauges at 2500 rpm when the car is stationary. Otherwise you get lower readings at idle.
@bertramlrezenet9311
@bertramlrezenet9311 3 ай бұрын
For a DIY, you did great! Only once thing I'd like to add, it's a good practice to turn off your air recirculation switch while charging the A/C at 1200-1500 RPM, as the charging chart temp is normally taken as outside ambient air.
@caiobabe
@caiobabe Жыл бұрын
Unless you are evacuating a system or drawing a vacuum, you do not need to open the red (high) pressure valve on the manifold set. The gauge readings are irrespective of the manifold valve positions. Gauge dials read with manifold valves open or close. The valves control the flow from the yellow hose to the respective colored valve.
@mateocarlos2674
@mateocarlos2674 Ай бұрын
It took me days to figure this out. It's amazing how few people explain the manifold function. Thanks.
@laurenceprantner8618
@laurenceprantner8618 5 ай бұрын
I do the same, but like to run a little refrigerant thru the low side line to purge as well. I never open the high side at the manifold, so that is that. If the system is empty, and repairs are done, I evacuate the system with a vacuum pump for an hour, check for leaks, then add refrigerant according to the levels indicated by the manufacturer on labels under the hood, looking for, as you said, pressures to be proper with the ambient air temp, and look for cold air out. Thanks for the vid, you do it right. Cheers!
@MiggyDLegend
@MiggyDLegend 2 ай бұрын
Hey there! Just a quick note to add, and please feel free to correct me if I’m mistaken. It seems like the high and low lines weren’t under vacuum, which means outside air might have been entering your system. Ideally, you’d want to use a vacuum to remove any air from the lines. Once that’s done, make sure to seal them off to prevent any outside air from getting back in. This way, your system stays clean and efficient. Hope this helps!” 😊
@joesalinas-ct8fz
@joesalinas-ct8fz Ай бұрын
All I have to say you is you did an awesome job
@15Xalbatross
@15Xalbatross Жыл бұрын
Can’t get much colder than that. Smart to keep it safe like you did. The beauty with these old trucks is they are simple and when they work they don’t need fixed until they break. I’d bet yours will blow cold for years to come unless the compressor fails. Good video!
@jeepinintexas6215
@jeepinintexas6215 Жыл бұрын
Well, when it comes to automotive AC systems whether mid 90s or later vehicles, this is no different than my 2012 Jeep or my 2013 daily driver Nissan which the latter was low on refrigerant. Same procedure and now it's more comfortable driving to work in 110°F+ temps here where I live.
@kge420
@kge420 3 ай бұрын
That system was low on refrigerant for a reason. There’s a leak somewhere. Refrigerant isn’t a consumable.
@danglenn569
@danglenn569 Жыл бұрын
Dude, that was awesome, and AC units are always unpredictable. But as long as it's blowing cold, you're good.
@1RoadGarage
@1RoadGarage Жыл бұрын
That’s what I’m thinking
@DrHavok1
@DrHavok1 5 ай бұрын
I'm about to replace my entire system in my 98 Jeep Grand Cherokee and I bought the gauge setup and I want to do this the right way so I am here learning and this is one of the best videos I have come across so far. I really want to know more about charging a new system and removing the old refrigerant from the old. such a good job on this video thanks brother
@latrogeniwile58
@latrogeniwile58 3 ай бұрын
I just redid mine, and it works better than it ever has. I have a handful of tricks I developed over the 26 years I've owned this truck. I also perfected the coolant mix and radiator swap. Just towed a trailer in 97F Austin heat, full blast AC, never budged off the 180F stat set, other than a flicker after encountering a traffic light. 4700lb trailer. These secrets remain unknown because your host insulted be and canceled some posts. Carry on.
@Harold-si7eh
@Harold-si7eh Ай бұрын
Many AC/Heater Systems the fan blows first through the heater core then through the Evaporator,if the control switch does not shut off the hot engine water going through the heater core this will cause the AC air to be a mix and will be warmer than it should be,check for a electric or vacuum Switch in the hot water system,on semi- trucks I have installed a manual Shut off to stop the hot water in and out of the heater core!!! This brings a big dro in AC vent Temperature!!!❤
@jewermank8536
@jewermank8536 Жыл бұрын
Jimmy, you've come a long way. Another good one man
@MarzNet256
@MarzNet256 Жыл бұрын
Very wise to stop when you did. The system is performing very well, the difference between the pressures is correct.
@safffff1000
@safffff1000 Жыл бұрын
Yea I blew out my compressor trying to get get the pressure up to what is recommended
@jimsix9929
@jimsix9929 4 ай бұрын
hey no worries mate, as temps go up pressure will also go up, you did a great job, if it goes low again then it is time to look for a leak, if you have to recharge a 2nd time then you should vacuum the system and also add some oil but for now you are solid gold!!!
@TruckDriver326
@TruckDriver326 Жыл бұрын
The video is a really good video for any DIYer to follow. I'm a DIYer I work on my Class 8 truck. Your information right on.
@hermanrogers1325
@hermanrogers1325 Жыл бұрын
Good job plain and simple now all we need to do is fix it so home owners can do this also
@land7776
@land7776 8 күн бұрын
Great video, I would add one little point. When youre ready to charge, purge the low pressure (blue) hose as well as the yellow can hose.
@zarrna
@zarrna 19 күн бұрын
Your video helped me fix my AC
@hotrodray6802
@hotrodray6802 10 ай бұрын
Charging a properly evacuated system is much much simpler if using the "delta drop" procedure. That is, at 1600 rpm, measuring the input air temperature going into the evaporator coil and the output air temp coming out while charging slowly and intermittently (to stabilize) to get the maximum temperature difference. Thats the ONLY way of accurately determining the exact proper charge. Also the accumulator will be warm about half way down and cold in the upper half. That tells you that theres reserve refrigerant in the system. Youre welcome. 😁😎
@John-eh6jg
@John-eh6jg 3 ай бұрын
I got pumped for you when I saw your vents shooting out 30degree air haha that's awesome . Great video buddy
@randyfuqua5890
@randyfuqua5890 Жыл бұрын
I too have a GMC, it too cools better when the pressures are lower than those that a pressure chart says what they aught to be. When the pressures are brought up to the charts specification, the temp rose from around 44-46 to 52 or so. Keep the pressures slightly low for the coldest air. Rf-TN
@777smitty4
@777smitty4 Жыл бұрын
Place a fan in front of radiator that helps to simulate a driving condition it changes your pressure readings
@edbrandt8972
@edbrandt8972 3 ай бұрын
I think the low side should also be purged before connecting the yellow line to the full can. Should be no need to purge the high side since refrigerant will never be added there.
@keithfreeman7886
@keithfreeman7886 Жыл бұрын
I don't know for sure but I've heard where one must vacuum all the refrigerant out and moisture before adding new refrigerant I've always heard that and to use a scale to measure how much to put back in according to the label under the hood
@Bizija123
@Bizija123 Жыл бұрын
It's the best way to know you are not undercharging or overcharging. Charging based on pressures is tricky and inaccurate.
@jonperry9979
@jonperry9979 Жыл бұрын
Jimmy I liked your video very much you explained all the processes very well.. I just finished working on my 95Chev just about the same system as yours. I only got the inside air temp down about 50* F until I drove it at freeway rpm’s then the temp came down to 45*. I was happy with that. The outside air temp was 98*.🤠
@brandyballoon
@brandyballoon 3 ай бұрын
In a two-phase system i.e. where you have the refrigerant existing as a liquid and a gas at the same time which is what's happening in both the evaporator and condensor when it's working properly, the pressure depends only on the temperature of the heat exchangers. Once there's enough for the proper two-phase cycle to occur, adding more refrigerant won't increase the pressure. All you're doing by adding more is increasing the proportion that in the liquid state. Too much will damage the compressor if liquid enters the compressor inlet from the evaporator or if the condenser is too full and backs up into the compressor outlet. The compressor wants gas only - liquid is bad. This is why there's a specific quantity of refrigerant specified. The only way to know for sure if the correct amount is in the system is to pump it all out with a vacuum pump and then refill it with a measured amount. It's measured by weight, not pressure. The gauges can give you an indication of the system performance, but they cannot tell you how much refrigerant is in the system. There are other potential causes of abberant pressure readings including a worn compressor, bad expansion valve etc.
@rruizproductions
@rruizproductions Жыл бұрын
Idle your engine to at least 1500 rpm. Your pressures should get to the idea measurements. Good job and explanation!
@lees5402
@lees5402 Ай бұрын
My Vivohome gauges do not have a schrader valve to purge the air before charging. OK I just watched an AC pro purge his air by opening the yellow charge line at the gauge even though he had a Schrader valve on his. So if you don't have that valve, that's another way of doing it. The main thing is don't add the freon until you purge the line of air. Hope this helps others like me. Thanks for posting.
@tyrehester5550
@tyrehester5550 Ай бұрын
Great video. I have that gauge set and my system needs Freon added. Your instructions were what I needed to have the confidence to get this done.
@bernardsantos4024
@bernardsantos4024 15 күн бұрын
Luv the way U make these videos and guide's I have same truck and your suggestions are perfect to me !!
@andycostilla
@andycostilla Жыл бұрын
Came across your video and provided me with directions to proceed. I saved it to refer back to the information. Thanks buddy, from South Texas where we are in 100° F heat dome.
@stuckinmygarage6220
@stuckinmygarage6220 Жыл бұрын
Stay Coooool! LOL Yes. Many do not use the vacuum like they should. I rent it from the local big boys. There is almost always some moisture in there after the years go on. Also, I'm sure you know, but if you suspect a leak - like your cold no longer cold in a week or so, you can use that fancy multi-legged thingy to push leak dye and UV light around (night better). BTW, save your gauges that come with some of the "rebate" canisters. You can use them on the refill cans, later.
@FireKnight43
@FireKnight43 2 ай бұрын
Very well done. Only thing I'd add is; check to see how much refrigerant a vehicle takes(should be by the weight). You don't want to overcharge a system.
@AllPraiseToYah
@AllPraiseToYah 3 ай бұрын
Hmmm, after 2. Can still no pressure increase on the low side. Sound like the expansion valve is stuck. This regulate the flow of refrigerant throw the system.
@petehubbell6747
@petehubbell6747 3 ай бұрын
Good point at the end of pointing out if you register 0 psi on guages you need to vac out air and moisture and be sure it holds showing no more leaks. Just had to order vaccuum and freon leak detector to find and fix before attempting refill.
@popie6735
@popie6735 Жыл бұрын
Not a pro here. But I have always only charged gas into the low side. Meaning the valve on the can is up. Tilting the can or putting it up side down will give you liquid. If you want to empty a can. Hang the can upright into a small bucket of hot water. I do the same with 30lb jugs too. Just makes the gas charge a little faster.
@publicmail2
@publicmail2 Жыл бұрын
The delta T on car AC is 30F, so if it's 100 inside car it will blow 70, there is no fixed ok temp, when cool in car 75F it should blow about 45F. Too much refrigerant will damage compressor. Charge for 30F delta and accumulator canister frosty to touch 70-80% of canister. If system is completely flat you have to fix leak, evacuate it, and recharge correct weight.
@44hawk28
@44hawk28 Жыл бұрын
Just for your edification, you can buy adapters to go on a 1234 system, because 134 will work in that system. When you get to about 11% of 134 in a 1234 system, you remove the fire hazard that the 1234 carries. It was well-known in Europe for causing engine fires quite frequently when they first started converting over to it. The other problem is is that the reason we use 134 is because it doesn't damage the ozone layer but they still can't explain why they're forcing us to convert over to yet another design except that the 134 patent has now expired. Just like R12 did a couple of decades ago. Many vehicles actually required elope side pressure to be somewhere around 30 to 35. The greater differential between the low-pressure and high-pressure which is usually around 275, the colder the air will be after it goes through the evaporator.
@0852657luis
@0852657luis Жыл бұрын
I was thinking just that. I don't know why they would stop using r134 considering how much better it is compared to the old stuff.
@GlennHamblin
@GlennHamblin Жыл бұрын
It's only better according to the DuPont Scientists who said it was after the patent on R-12 expired.
@brianherndon5820
@brianherndon5820 Жыл бұрын
​@GlennHamblin r-12 worked great but killed the ozone bad. 134 works pretty well with way less side effects to the ozone. Why they released 1234 I have no idea
@ruben_balea
@ruben_balea Жыл бұрын
In theory it's because r134 is a greenhouse gas 100-120 times more powerful than CO2
@norman7179
@norman7179 5 ай бұрын
@@brianherndon5820 R-1234 YR 3 times the price.
@jpol3808
@jpol3808 3 ай бұрын
I saw comments from pros that said you did a great diy job and I fully agree! And yes better a little low than high. I usually just check with the thermometer and add until I hit 40 to 45 and the compressor runs constantly in full cool mode. I personally don't like the super cold air blowing on me. I'd rather chill out... Slowly! Later.
@TheChabm
@TheChabm 6 ай бұрын
I am also a DIYer.. on the r134a chart (i.e. 175-210psi on the highside), i rev to 2500rpm to get that highside range.. that would also be safer.. avoid high pressure hose from bursting.. that's just mu process :)
@MrAcacio
@MrAcacio 5 ай бұрын
Excellent video... For sure will help a lot people saving money out there. To know a good and honest mechanic shop that you can trust in this days is very hard and its sad to say it. Thank you so much for this great video. May God bless you.
@JettaRedIII
@JettaRedIII Жыл бұрын
When the weather got hot this year, my truck (a 2000 Ford F-150), also was not cooling. I found one of the Schrader valves was leaking. So, after replacing the valve, I recharged the system and it started cooling like yours.
@marksullivan9179
@marksullivan9179 Ай бұрын
Great video, the only thing I would say is if you had to put two cans of freon in you've got a leak somewhere
@martinswan9175
@martinswan9175 Жыл бұрын
Awesome video, this is in my near future too since the cost of doing this at the shop will be more than buying the necessary tools. Thanks✌
@j.bow87
@j.bow87 Жыл бұрын
You really need to recover all, check for leaks, and vacuum and fill to how much your OE manufacture says to have in it. Just checking by pressure is a great way to overfill your ac system and damage your ac compressor.
@1RoadGarage
@1RoadGarage Жыл бұрын
Thanks for the input.
@KensCounselingCouch
@KensCounselingCouch Жыл бұрын
I'm finishing a compressor replacement on my 05 t&c today. I thankfully saw before getting into this project that pressure by itself doesn't tell you how much refrigerant needs to go into the system. So I bought a kitchen scale, I 'obtained' a copy of the factory service manual, and figured out exactly how much oil & refrigerant I need to put into my system. So I'll be able to measure the exact ounces coming from the scale into the system and I've got the factory manual which has great info on how exactly to perform the tasks I need to do. Already swapped compressor, seals and o-rings, pulled my vacuum & no leaks. Just need to make a final trip to the parts store cause my stupid can tap was machined improperly and doesn't fit the acme 1/4” connectors like it should. Hopefully I can pull this off and get this AC working strong before a thousand mile move!
@avgFloridian
@avgFloridian 2 ай бұрын
Probably a pretty good guess on how much to add for you. Mine was completely open, so I had to grab new O-rings and vacuum test the system. I refilled by weight. I am going to pressure test this weekend again, mostly to verify it's the relay that went bad. (I can't just swap out a $10 relay in my car. It's a whole control module.)
@jimmycorbett4611
@jimmycorbett4611 Жыл бұрын
Jimmy, could you make a video showing how to replace your coolant on your 95 suburban? I have a 1998 gmt400 truck and am planning on doing this myself soon. I always watch your videos because you are always so thorough and meticulous about everything. I assumed you already would have a video of this but when I checked and you didn’t, I figured I would ask if you’d make one if your coolant needs to be changed. Thanks either way, love the videos, from Jimmy to Jimmy👍👍
@keithfreeman7886
@keithfreeman7886 Жыл бұрын
Don't get me wrong though I like your videos I like your style and I like the way you present doing your own mechanicking Air conditioning is always tricky what you doing really well job of explaining and showing what one should do thank you for that
@stevewheatley243
@stevewheatley243 2 ай бұрын
You done right. Any automotive AC does better driving. The compressor rpms circulate the freon better. I probably wouldn't add anymore. Who's to say how accurate the guages are?
@danhambrick6331
@danhambrick6331 Жыл бұрын
Nice job Jimmy.Looks like you fixed your problem,now a bunch of keyboard commandos are going to tell you what you did wrong.😂😂👍👍
@MonsterNinjaz
@MonsterNinjaz Жыл бұрын
I hate youtube for this exact reason.. everybody in the comments section an expert on everything... shits ridiculous
@DrHavok1
@DrHavok1 5 ай бұрын
lots of them especially in this comments section actually gave great advice and compliments... this guy did his homework though ad did this the right way
@kmlumd44
@kmlumd44 4 ай бұрын
Can you fill an AC system using the gauges instead of using the specified quantity of R134 under the hood?? Is he saying it doesn't matter if you disregard the specified quantity? Cause I got a car that isn't blowing super cold, but the system is sealed still after 20 years, and I was gonna evacuate the system before filling it so that way the quanitty is correct... But based on this guy's logic I can just see what the gauges are at and add however I see fit as long as the guages are in spec.
@kmlumd44
@kmlumd44 4 ай бұрын
I don't wanna mess up my system by just adding R134 til the gauges read within spec at the risk of overfilling with Freon...?
@DelrioTheolus
@DelrioTheolus 4 күн бұрын
good job I have learning a lot from you.
@JG-yd8so
@JG-yd8so 2 ай бұрын
When adding refrigerant, never add liquid (high) though the gas ( low) side. The refrigerant instructions state tipping the can, however that introduces liquid into the gas side of the system, that’s how internal restrictions are created. Only top off with gas. It will take longer but ,, that’s the correct/ safest way to top off refrigerant . Many garages/ DIYrs will do it incorrectly to save time ( at the moment) or ignorance. When the system efficiency drops, it will take much more time and parts to correct the previous errors.
@AntonioClaudioMichael
@AntonioClaudioMichael Жыл бұрын
In america Vacuuming ac systems Standards are 10 minutes at 20 Inches Of Mercury to Boil off any water in the system if it passes 10 minutes no need to continue if it dosent then you need to do a 30 to 40 minute Vacuum Jimmy @1Road
@AntonioClaudioMichael
@AntonioClaudioMichael Жыл бұрын
Over filling is worse then underfilling for ac systems you didna great job Jimmy @1Road
@robalan57
@robalan57 3 ай бұрын
The straight end of hosed connect to the gauge set. There is a label on your vehicle under the hood that tells the amount of refrigerant your vehicle can hold. Sometimes it is less than the 24 ounces you added to your vehicle. So you may or may not be ok depending on your vehicle.
@Dark_Knight_USA
@Dark_Knight_USA 3 ай бұрын
Greetings: Ujunk...Great place w watch the blind leading the blind. Thx 4 the share.
@creekmud2857
@creekmud2857 Жыл бұрын
Question did you purge the suction and discharge? I noticed you purged the feeder hose but you didn't purge the other ones! Anyways great video... I'm a 29-year service technician from Nashville Tennessee
@1RoadGarage
@1RoadGarage Жыл бұрын
I’m in middle TN as well. Currently trying to solve a rough idle on my ‘05 Envoy. Check my latest video I just uploaded. Here’s a link to my fuel trims: Live Data From 2005 GMC Envoy! Help Me Diagnose Rough Idle! kzbin.infotTO8Oc_T1k0?feature=share
@RichardBonecito
@RichardBonecito Жыл бұрын
​@@1RoadGarageignored the question entirely.
@datsuntoyy
@datsuntoyy 2 ай бұрын
7:15 Didn't purge the high and low pressure hoses. I charge according to the high side. If the low side is way off, you likely have a restriction. My car was last charged by a pro (I used to be, still universal refrigerant certified) to the weight specified by the manufacturer. It wasn't super cold so I checked it myself and it was 15psi low on the high side. Brought high up 15 psi and I can blow 42 degree air at 115 outside. 36 at 100. When it can get really hot like 110+ outside, you want to make sure you are at the low end of the range when charging at lower outside temps. In regards to yours at 80, I'd add maybe another 10 psi high, but I wouldn't open a new can for that little change. But remember what I said about temp, it can get over 120 here and high side can skyrocket at that temp while stopped at a light so restraint needs to be used when charging.
@vernonbosshard9317
@vernonbosshard9317 Жыл бұрын
I like those gauges, they have a port for the vacuum and the freon so you can vac and then charge with out breaking any connections,
@deanlockamy2087
@deanlockamy2087 Жыл бұрын
Love my Harbor Freight AC gauges too.
@1RoadGarage
@1RoadGarage Жыл бұрын
They’re actually really nice gauges
@thomasward4505
@thomasward4505 Ай бұрын
When I charge AC I generally look for the high side to be about eight times whatever the low side is. When that happens cold air will come out of the vents. My high side pressure are always higher than your chart
@frank9649
@frank9649 5 ай бұрын
HI, for sake of argument , lets say your system takes 34oz of refrigerant...it will work better(believe it or not) with 31-32oz. Also wash your condenser rad with a garden hose it will help for better results. thanks for the vid, be well !
@dgc940
@dgc940 Жыл бұрын
Look at your gauges again carefully there is differant scales for different refrigerants listed on bottom sbove needle stop pin. The manifold reads 3 differnt types refrigerants. I believe your eyes are focused on the outter black numbers on gauge.
@DrFiero
@DrFiero Жыл бұрын
You have the correct adapter for that can. It's a self sealing can. The tip of the depressing rod is FLAT. You can remove the tap after retracting the rod. For anyone else - Don't use the other common can tap that has a POINTY end! Those are for the cans that have a puncture top. Once those are engaged (handle is turned down) you can't remove the tap or the can will just dump out.
@jmead2294
@jmead2294 Жыл бұрын
You can do this without having to drive around. Just put a high output fan in front of your radiator to blow air through your system just as if you were driving around. If you dont have enough airflow through your condenser, the system will not operate properly. The fan on your engine will not pull enough air through the condenser at an idle. Especially if you have electric fans.
@emmanuelmallarijr7715
@emmanuelmallarijr7715 3 ай бұрын
Rev the engine at steady 2000rpm during charging will do as opposed to driving around
@MrManolismo
@MrManolismo 11 ай бұрын
make sure your aircon motor sometimes not engaged, if not it will not last long. thanks for your effort.
@JamesAutoDude
@JamesAutoDude Жыл бұрын
I would also check your fan. I believe this is a fan clutch vehicle and it's likely weak / needs to be replaced. That'll definitely help with your sitting still pressures
@jeffreyshagerty2552
@jeffreyshagerty2552 2 ай бұрын
You just taught me exactly what I needed to know, thank you 😊
@johngouker3887
@johngouker3887 2 ай бұрын
You did good Filling the system back up but you didn't find out where you lost 24 oz's to Atmosphere !! Happy motoring !
@jamkpa
@jamkpa Жыл бұрын
Should the red and blue hoses be bleed of air too?
@cup_and_cone
@cup_and_cone Жыл бұрын
Only if they're opened at the manifold. The high pressure side doesn't 'feed' into the system and the high pressure manifold valve didn't have any reason to be opened in this top off scenario. The low side should have been bled by cracking the manifold valve open slightly with the yellow fill hose side disconnected/open to bleed it out, then reclose the manifold valve. Yellow fill is always bled every time you connect a bottle/can.
@billw0129
@billw0129 5 ай бұрын
Was just about close the video out just before your said “ if your system has no pressure ……” & guess what, I went outside to check the pressure amd there is none on high side and low side. Looks like I gotta find the leak. Appreciate the video
@normheath7447
@normheath7447 Жыл бұрын
It would have been good to first to pull a vacuum on the system to make sure it doesn't have any leaks. The fact that you had to add 2 can of R132 A tells me that you do have a leak and your fix is temporary. All in all good video , this is how we all learn. O'Reillys Auto here in Bozeman will lend the gauge set and vacuum pump to make testing and recharging with very little cost
@fastst1
@fastst1 Жыл бұрын
pulling a vac on the system would require dumping all of the 134 out of the system, without a recovery device this is a bad idea. It looks like a GM that's a couple decades old. A leak detector is a better idea
@dgc940
@dgc940 Жыл бұрын
Yep a sealed system that leaks isnt a sealed system lol
@CalkoLouie
@CalkoLouie Жыл бұрын
You made it be a succes, definately but you still have to find the leak, great video.
@smartunnel
@smartunnel 3 ай бұрын
What about compressor oil? How to check whether it has enough or less oil?
@raypelletier9920
@raypelletier9920 2 ай бұрын
Great video will be following your steps in the process. Including tools.
@ReaperLSX
@ReaperLSX Жыл бұрын
Awesome video, I got my 03 avalanche last year and hasn't had any AC and I have to fix this soon
@bmfilmnut
@bmfilmnut 26 күн бұрын
I'm just learning how to properly charge auto A/C systems with a proper set of manifold gauges so I've been watching a lot of videos. I noticed that some pros read the pressures when the engine is revved up to 1,500 to 2,500 rpms. I wonder if that's why your readings are low.
@rubbertoea8088
@rubbertoea8088 Ай бұрын
I love your videos. I just had my father's RAV4 serviced because it was not blowing cold air. The shop I took it to in Mexico did the following. They checked the pressure and realized it was low. They did a vacuum on the AC using a pump and then refilled it with Nitrogen and checked for leaks. Thy found a leak on the one of the ports so they replaced the shredder valve. They refilled with nitrogen and retested it. After that they filled it with Refrigerant and they used a scale to check how much gas they needed it to put in (there is a sticker in the hood that says how much). They also added an oil using a special syringe that connected to the intake hose.
@meseahunt
@meseahunt Жыл бұрын
good job for a diy'er, always stay on the cautious side and DO NOT add tooooooo much 🤠
@PeterAndrew-jh9gw
@PeterAndrew-jh9gw 4 ай бұрын
You do everything perfectly sir
@danp7463
@danp7463 2 ай бұрын
That looks like a Suburban. If it has rear a/c than the refrigerant capacity is 49 oz. Without rear a/c the fill capacity is only 26 oz. So simple math on two cans that you added that's only 24 oz. I'd check the sticker on the underside of the hood or on the core support and that will say exactly how much refrigerant you need. If adding 24 oz didn't put you in the nominal pressure range it's likely you have rear a/c.
@miguelfroml.a.9310
@miguelfroml.a.9310 2 ай бұрын
yes is success. congrats !!! you make great job.
@SkaterWalsien-mp2uh
@SkaterWalsien-mp2uh 2 ай бұрын
Gd day,,, yes ur recharge procedure was properly done,,, but for my opinion u forgot 2 wet the condenser in between charging procedure,,, to simulate proper cycle of a/c operation ,,,thank u,
@billw0129
@billw0129 5 ай бұрын
Awesome- Thanks for sharing- gonna give it a go on my vehicle
How to Pull a Vacuum and Recharge Your AC System - ULTIMATE GUIDE - HVAC
25:45
How To Recharge an AC System - EricTheCarGuy
23:49
EricTheCarGuy
Рет қаралды 4,2 МЛН
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 117 МЛН
My daughter is creative when it comes to eating food #funny #comedy #cute #baby#smart girl
00:17
A/C Diagnosis-Sticking Thermal Expansion Valve (TXV, H-Valve)
31:46
ScannerDanner
Рет қаралды 1,5 МЛН
Replacing coils for rude customers
12:13
Rhodes Repair - HEATING AND AIR
Рет қаралды 4,2 М.
DIY Testing, Fixing, & Recharging A/C
18:35
That Shop Teacher Guy
Рет қаралды 659 М.
I can't believe Mechanics don't know How to Recharge AC system correctly!
7:46
NATES INTERACTIVE AUTO
Рет қаралды 4,5 МЛН
How To Add Refrigerant With Gauges (DIY A/C Recharge)
6:51
Chris Ryan's Workshop
Рет қаралды 6 М.
Never Use This on Your Car's AC System
7:33
Scotty Kilmer
Рет қаралды 2,5 МЛН
AC not blowing cold, then it works fine !?!?  What could cause this?
15:26
Wrenching With Kenny
Рет қаралды 320 М.
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 117 МЛН