honeywell 8148A main operating control replaced on boiler

  Рет қаралды 24,748

steven lavimoniere

steven lavimoniere

9 жыл бұрын

honeywell 8148A main operating control circulator part of the control would not work .replaced with new one

Пікірлер: 42
@arcticminer32
@arcticminer32 3 жыл бұрын
Thanks for the descriptive video. Five years later I am using your advice on a boiler in Alaska.
@arniegrote319
@arniegrote319 9 жыл бұрын
Nice Job Steve, Marking the wires, Smart, Saves time, And using the crimp connector, Makes a good connection, I see a lot of wires wrapped around screws. Again Nice Job.
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Arnie Grote i like the connectors like you said it makes a better job
@JohnDoe-zb6rx
@JohnDoe-zb6rx 7 жыл бұрын
Hi Steve, love your channel, lots of valuable info. I have a WBV -04 Peerless Oil fired Boiler. It' a cold start, demand only, setup. 2 Taco, 3 zone valve control units. Two Taco Circulators, 3 zones on one, and two on the other. 5 zones total with room for one more.Separate Bock 32 gal oil fired hot water heater. I installed this about 6-7 years ago and have not had any problems since. An intermittent temp/ pressure gage went last winter and almost gave me a heart attack, gage pressure went to 40 Psi and then back and forth to 18psi .........? This year after cleaning and tuning up my units I fired up the boiler and turned up a couple on thermostats. A Honeywell L8148A1090 Aquastat came packaged with the boiler when a bought it. A few minutes after starting it up I noticed a melting plastic smell or fume coming from the top of Aquastat? I believe it was coming from the Transformer if that's what that coil wired plastic unit is on the top left hand corner of that unit? There's actually a clear plastic dried puddle on the top of the transformer metallic armature? I had a boiler tech come in who is someone that I know and when I started it up again, the smell started again and then went away. Honeywell has discontinued my Aquastat along with many others. It seems a recommended replacement is the L8148A"1017". I spoke to Honeywell tech support for hours and they told me they would not say or acknowledge that the "1017" unit would work for me despite their own Honeywell site having "A Cross-reference dated July , 2015 of last year saying that it would? They're pushing their new L7224U1002 Aquastat which is digital, and a universal, but has more bells and whistles than I need? I just want a simple control to replace my old one so I can move on. I realize my old unit had a fixed differential of 15 degrees where the 1017 has a fixed of 8 degrees, but I don't think that matters for my cold start, demand only, heating system? I apologize for this lengthy comment and inquiry, but if you could give me some advise on the best aqua-stat replacement for my system I would appreciate it greatly. If you need pics of my system I will be glad to send them. I am a retired General, and Carpenter Contracter and have/had worked hands on my entire life. Thank You, John
@richardangelini7296
@richardangelini7296 3 жыл бұрын
Your videos are greatly appreciated.
@eastcoastHVACtech
@eastcoastHVACtech 9 жыл бұрын
Nice video, good tutorial of the control at the end for the newer guys in the trade.
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
eastcoastHVACtech thanks for watching
@phillipgroom9187
@phillipgroom9187 9 жыл бұрын
Great video,you know your stuff.Thanks for the video and the time you put in recording and editing them.
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Phillip Groom thanks for the support
@harrydickson4575
@harrydickson4575 9 жыл бұрын
Fantastic video Steve Great stuff !!!!
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Harry Dickson thanks for watching harry
@iamskippy1976
@iamskippy1976 7 жыл бұрын
when that probe goes into that brass fitting what keeps the water from coming out? I have to change mine on a gas fired boiler
@jpatt1000
@jpatt1000 7 жыл бұрын
Does the boiler temp sensing bulb sit in a well so you don't have to drain the boiler? I can flex the circuit board to get my circulator to run so I'm thinking I just have a bad solder joint. Just don't want to get scalded pulling the relay out when I shouldn't!
@ziyadd2835
@ziyadd2835 3 жыл бұрын
Hi Steve how are you doing hope everything is going well with you and your family this ziyad calling from Canada 🇨🇦 just a question iam a general contractor and i do my hvac work This a bolier question the honeywell aquastat box it works only if you push your hand on the damper plug up or down kind of moving it around then the boiler work the way it should be so do you think the damer plug is not good the pins or the plug it self on the aquastat it self So when you move around the plug on the aquastat then the intire operation works good 1 the draft vent opens 2 the flam is on 3 the gas line opnes 4 then it fires 🔥 So not sure the aquastat it does all the steps only if you move the plug on the aquastat Thank you you stev By the way you are the best tec I really mean it Thank you for all the hard work you do on line
@jhhvacplumbing1944
@jhhvacplumbing1944 9 жыл бұрын
Nice work again Steve
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
justin henning thanks justin
@FcsstlHeatingCoolingPlumbing
@FcsstlHeatingCoolingPlumbing 9 жыл бұрын
Looks like it was your first time there, hopefully you added another repeat customer to your books.
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
First Choice Service LLC ( StL MO) i am sure i will be back for something else in the future
@MyJubilation
@MyJubilation 4 жыл бұрын
When the air vent on top of the oil fired boiler spewed water on the aquastat box, it caused it to start giving off a dark gray smoke. After almost 2 weeks it's still smoking when I turn on the boiler. Can I fix it, or must I replace it? Shouldn't it be dried enough to operate, or can the smoke burn off without turning into fire hazard?
@hllywd964
@hllywd964 9 жыл бұрын
very informative, nice job!
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
hllywd964 thanks hollywood
@gekkedirkie
@gekkedirkie 9 жыл бұрын
Nice camera angle, good job..
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
gekkedirkie thanks for watching
@bbm8873417
@bbm8873417 9 жыл бұрын
Good job Steve
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Bernard Sobbe thanks for watching
@mathewbetcher9663
@mathewbetcher9663 9 жыл бұрын
+1 do you use he heat conductive compound stuff on the probe? It's supposed to make it more accurate. When I have it I use it, never really noticed a difference though
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
M Bet i never use that stuff i guess it would not hurt . its just never seez
@paulroggemann1017
@paulroggemann1017 3 жыл бұрын
@@stevenlavimoniere I believe it is a thermal conductive paste. Commonly used on heat sinks to improve thermal conductivity.
@whommee
@whommee 9 жыл бұрын
good vid ,,, just curious, do you think it was some of the contacts on the relay fried?
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
nate something in the control on the circulator leg was not allowing voltage to flow to circulator so the control was replaced
@f.j.g.j.6563
@f.j.g.j.6563 5 жыл бұрын
Me gustan tus vídeos aunque no hablo inglés bueno muy poquito!
@SurferBoy690
@SurferBoy690 4 жыл бұрын
I noticed in the video that the old Aquastat was the 1090 version of the L8148A (from the side sticker), but you replaced it with the 1017 version. As far as I can tell the 1090 has a fixed 15 degree differential and the 1017 has a fixed 8 degree differential. What is the consequence of this? Let's say both Aquastats were set to 180 degrees. Does that mean that the 1090 would go to 180, turn off the burner, and then restart the burner when the temperature dropped to 165, but the 1017 would go to 180, turn off the burner, and restart the burner at 172? Am I understanding this correctly? Or does this differential refer to something else? Every explanation I've read online has to do with Hi-Lo Aquastats with domestic hot water. Can anyone help me understand what the differential means here for this high-limit-only Aquastat? And if my understanding is correct, what would be the consequence for the boiler now having shorter, more frequent burns?
@dieselhater
@dieselhater 9 жыл бұрын
Hope your cold gets better
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Al Gregory its getting better
@nelsondonnell1393
@nelsondonnell1393 5 жыл бұрын
I've noticed that in all of your videos on replacing the Aquastat Relay that I've viewed, you never put any thermal heat paste on the sensing probe, why's that? Doesn't the manufacturer of the relay recommend that the thermal paste be used on the probe any longer?
@Brad1237202
@Brad1237202 9 жыл бұрын
Nice job Steven! If you could do a video and and your opinion on the propane/natural gas TracPipe.
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Brad1237202 trac pipe is not something i usually install,,, i like black pipe better for gas . i guess it has its place .if you have a long run up into a actic . it would save time .but it has to be grounded. because of lighting stricks
@guzman9011
@guzman9011 8 жыл бұрын
Mines makes a loud buzzing sound 24/7 is that normal?
@stevenlavimoniere
@stevenlavimoniere 8 жыл бұрын
+noe name replace the control it had a bad transformer ,in it
@tiaandbuster
@tiaandbuster 9 жыл бұрын
great video steve . I noticed you never use anti - seize on the sensor tube . I always use it on every new install and replacement . i carry a bottle of anti - seize with me all the time . it's just a habbit I got into years ago . I just find it makes a much better contact with the temperature in the boiler . it seems it makes the temperature more accurate to me . but that's just my opinion . we all have our own ways of doing things that works for us . just curious . nice job again buddy ........ I see you're still fighting that cold , I know how you feel , I have had pneumonia now for 2 weeks . it really saps the shit out of you ....... take care ........
@stevenlavimoniere
@stevenlavimoniere 9 жыл бұрын
Lloyd .Haight i probley should use the antiseez i just never do .i make sure the probe is into well all the way ,i never have a problem with it all the ones i replace never have any never seez on them eather right from the factory .. so i guess its not that important .. if the boiler manufature do not use it
@Bob.W.
@Bob.W. 6 жыл бұрын
You work when sick. Often.
heating no domestic hot water honeywell aquastat
14:05
steven lavimoniere
Рет қаралды 51 М.
black soot from boiler & other issues
35:14
steven lavimoniere
Рет қаралды 36 М.
Double Stacked Pizza @Lionfield @ChefRush
00:33
albert_cancook
Рет қаралды 119 МЛН
哈莉奎因以为小丑不爱她了#joker #cosplay #Harriet Quinn
00:22
佐助与鸣人
Рет қаралды 8 МЛН
Son ❤️ #shorts by Leisi Show
00:41
Leisi Show
Рет қаралды 8 МЛН
How L8148E1265 Aquastat works
7:57
Geo Electronix
Рет қаралды 10 М.
NEW VIESSMANN HIGH EFFICIENCY BOILER JOB HEAT RUNNING WILD
27:19
steven lavimoniere
Рет қаралды 23 М.
burnham boiler honeywell L8148A main operation control replacement
12:27
steven lavimoniere
Рет қаралды 100 М.
HONEYWELL RA832A PUMP RELAY REPLACEMENT.  TROUBLESHOOTING
9:53
Alex The Handyman
Рет қаралды 4,9 М.
Triple Aquastat Basics
12:08
Jersey Mike HVAC
Рет қаралды 6 М.
Hydronics - Aquastats
9:32
Christopher Molnar
Рет қаралды 12 М.
no heat on first floor bad taco 007 circulator replaced,purged air
21:32
steven lavimoniere
Рет қаралды 127 М.
L8148 Aquastat wiring with zone valves
17:55
Tony Saccavino-HVAC Instructor
Рет қаралды 9 М.
Honeywell Basic Hydronic Control Training
11:37
Neuco
Рет қаралды 78 М.
I Just Wanted to Build a House! 😭
0:22
ToolTastic
Рет қаралды 6 МЛН
She realized that true happiness was not near this guy 😇🦄❤️‍🔥
0:12
iPolina Queen of the Cringe 👑
Рет қаралды 79 МЛН
Are you competing for excitement or excitement and humor? Shoot as you please. Don't follow the
0:56
Será Que a FITA vai Grudar ela na PAREDE😱 #shorts
0:44
Lucan Pevidor
Рет қаралды 67 МЛН