Honeywell/System sensor fire alarm device recall | L-series low frequency

  Рет қаралды 5,984

NIC’S - SYSTEMS & ELECTRIC

NIC’S - SYSTEMS & ELECTRIC

Күн бұрын

Honeywell/system sensor recall information
buildings.hone...

Пікірлер: 93
@zachzebra56
@zachzebra56 5 ай бұрын
Wow! At least this isn't as widespread as the BG-10 recall. Lucky my school uses spectralert advanced/L series speaker strobe's so they don't have to worry about removing every single NA to see if it was affected. It would be painful. Believe me, there's definitely over a hundred with most of them ceiling mount, some on high ceilings.
@joeycaridi3030
@joeycaridi3030 5 ай бұрын
This is very crazy! It's been a long time since Honeywell had to recall a bunch of products which were the BG-10 series of pull stations in April of 2013 due to the rubber gasket seal around the button degrading, causing the button to stick, which would cause delayed fire alarm activation and also that the Hex screw models are prone to break easily from overtightening that would break the screw or the pull station and also earlier models of the BG-10 series had a plastic button that works all the time because it's very clickly rather than a metal button and there also rubber gasket replacement kits as well for those who don't want to replace it. So yes this was a serious issue with the L-Series low frequency sounder devices of how they won't sound loud (like at around 75 dB because all fire alarms need to be 15 dB higher than 75 dB for the high volume setting where's low volume is less than 90 dB) or not sound at all and just flash which is because they've must've used the wrong inductor for the manufacturing process and didn't stay well soldered into the board as the normal horn inductors for fire alarms I believe are 10 mH (10 milliHenrys) 10x16 5 pcs inductors. And I also see that at 05:18 you have gotten a System Sensor CHSWL L-Series Chimes Strobe to be installed in Garage Building B and I wonder what room will it be installed in.
@captainchris2016
@captainchris2016 5 ай бұрын
Just because he has a chime strobe does not mean hes gonna install it in the garage building (you can see it in the video)
@JourdainNovak
@JourdainNovak 5 ай бұрын
Is the alarm below one of the low frequency sounders a horn strone with an amber lense a horn strobe.
@themexicanmerc
@themexicanmerc 5 ай бұрын
what is this alert horn strobe that you will explain on a short video soon?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Whenever it's video gets upload
@NewEnglandAviaton987
@NewEnglandAviaton987 5 ай бұрын
@@nics-systems-electricmine start with 1
@baseballlion1615
@baseballlion1615 5 ай бұрын
I think I figured out what it’s for
@FireAlarmGuy-8090
@FireAlarmGuy-8090 5 ай бұрын
@@baseballlion1615what
@NewEnglandAviaton987
@NewEnglandAviaton987 4 ай бұрын
@@baseballlion1615it’s for the systems being linked together
@stormspotter
@stormspotter 5 ай бұрын
you are prepared for any thing i like that keep on doing what you love what is the yellow one for is that severe weather
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
The device with the Amber lens will go off if the separate garage system goes into alarm
@bottlerat2318
@bottlerat2318 5 ай бұрын
I have system sensor HRs in my home bedrooms, should i do low frequency instead?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Low frequency sounders are superior for waking sleeping occupants that is what they are designed to do as lower frequencies wakes you from a sleep more effectively
@TheLastWolfBane
@TheLastWolfBane 5 ай бұрын
Wow, that's new
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Yes, the recall was issued as of March 14, 2024
@TheLastWolfBane
@TheLastWolfBane 5 ай бұрын
@@nics-systems-electric I mean it's not relevant to me, but fun to know Only from the best
@DaSamNudge
@DaSamNudge 5 ай бұрын
I'm quite interested in the story behind that alert chime(?)/strobe
@firealarm421
@firealarm421 5 ай бұрын
I have a red l series low frequency sounder and mine is 2094
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Then that is not affected by the recall so it's all good
@firealarm421
@firealarm421 5 ай бұрын
@@nics-systems-electric I see you also got an Amber Alert strobe installed. Will there be a video on it in the future?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
@@firealarm421 yup
@FireAlarmGuy-8090
@FireAlarmGuy-8090 5 ай бұрын
What are the yellow strobes for
@cyberlight22
@cyberlight22 5 ай бұрын
did you make a video about the amber strobe and I missed that one
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
There will be a video eventually
@B9L3_Official
@B9L3_Official 5 ай бұрын
I actually made a video about this. This is pretty cool. That Nic is reporting on it too. But that video I made was 19 mins long
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
How did you manage to make a video that long about it?
@B9L3_Official
@B9L3_Official 5 ай бұрын
@@nics-systems-electric Because I read the document. And mention how I found the recall.
@B9L3_Official
@B9L3_Official 5 ай бұрын
I mentioned how similar it was to the EST situation. And I didn't manage to make a video of how to check it because I didn't have any similar devices.
@B9L3_Official
@B9L3_Official 5 ай бұрын
Oh yeah, and I have to mention theres microphone problems. For some reason???
@achannelwithnopurpose1977
@achannelwithnopurpose1977 5 ай бұрын
At least you don’t have to swap anything. Always good to proactively check though.
@NyxKemo
@NyxKemo 5 ай бұрын
Honestly surprised that System Sensor has a recall, also new alarm below the main one in the basement, wonder what it’s for
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
This video was posted as a time sensitive video so that device won't be featured in some videos until it's time comes around for its upload
@NyxKemo
@NyxKemo 5 ай бұрын
@@nics-systems-electric oh alright
@vintagesimplexfirealarmsof6440
@vintagesimplexfirealarmsof6440 5 ай бұрын
who's better 9838s on march time/continuous or low frequency sounders for alerting
@Fire-Lite457
@Fire-Lite457 5 ай бұрын
I have a ceiling mount white L-Series PC2WL-LF. Not part of the recall.
@UKsystems
@UKsystems 5 ай бұрын
At least they recall instead of just leaving it
@matthewnskamura
@matthewnskamura 5 ай бұрын
is it stilll being sold?
@ESTedwards
@ESTedwards 5 ай бұрын
The "GARAGE" horn strobe is actually a chime strobe meant for alerting the people in the building of an active supervisory. i know this is a chine strobe because of one of his more recent videos (kzbin.info/www/bejne/bZmyfqucm7WXfrM) Adding an annunciator to my home fire alarm system, he shows a bypass for the garage building chimes.
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Ayy someone really knows their stuff and has been paying good attention right on brotha
@LI0ydJoe
@LI0ydJoe 5 ай бұрын
Show us how you made your system? Wireless? Etc, we'd love to know!
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Check out KZbin channel I have an entire playlist on it
@BeurmaDinkuri
@BeurmaDinkuri 5 ай бұрын
are they going to continue to replace the low frequency sounders to mini horns just for now?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
There's no need to replace anything other than affected product code
@Will-c2l
@Will-c2l 5 ай бұрын
Is the regular l series hornstrobes affected?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
No low frequency only as was said in the video as well as the particular model numbers that are affected and product date codes
@keithpierce8458
@keithpierce8458 5 ай бұрын
Are they replacing low frequency Sounders to led low frequency sounders
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Definitely not. that would be a ridiculous thing to do. huge waste of money for no reason especially when it's the same product that is meant to be compatible with each other there is zero reason to do that.
@UriahStuff
@UriahStuff 5 ай бұрын
I think low frequency sounders should be required on home smoke alarms.
@William_lambo
@William_lambo 5 ай бұрын
Wow
@wibwabz
@wibwabz 5 ай бұрын
Something about how you are holding the device in the first few seconds looks strange.
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
I'll hold it with my feet next time if you'd prefer that
@wibwabz
@wibwabz 5 ай бұрын
@@nics-systems-electric HAHA!
@FireAlarmsOfPensacolaFlorida
@FireAlarmsOfPensacolaFlorida 5 ай бұрын
Honeywell quality!
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
They are getting as bad as wheelock and Edwards and simplex
@JMWtrainsnstuff
@JMWtrainsnstuff 5 ай бұрын
If those are all bad then who's good? I understand Edwards sucks but neither Wheelock nor Simplex have recalls like that
@joeycaridi3030
@joeycaridi3030 5 ай бұрын
@@JMWtrainsnstuff If they're all bad, then the fire alarm industry might be failing and they will be major complaints to reshape these businesses as maybe it could be a problem with manufacturing materials or the way how the economy works
@JMWtrainsnstuff
@JMWtrainsnstuff 5 ай бұрын
@@joeycaridi3030 I'm not saying that. I'm just going off what Nic said
@FireAlarmsOfPensacolaFlorida
@FireAlarmsOfPensacolaFlorida 5 ай бұрын
@@nics-systems-electric real, I don’t think Wheelock fell off as much as those companies you listed, but yeah. You can’t really find anything good nowadays. That’s why I love older devices so much.
@kylespencer1169
@kylespencer1169 5 ай бұрын
Bring Gentex back
@Big-cc3nn
@Big-cc3nn 5 ай бұрын
only ogs remember pickle 700
@Comens1997
@Comens1997 5 ай бұрын
Can i have?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Sorry, I don't understand your comment
@Comens1997
@Comens1997 5 ай бұрын
You need a terrepery
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
@@Comens1997 man i still have no idea what you're saying
@CGray1234
@CGray1234 5 ай бұрын
Speaking in tongues fr
@Comens1997
@Comens1997 5 ай бұрын
@@CGray1234 you need a terrepery
@Comens1997
@Comens1997 5 ай бұрын
I have in paper made
@Comens1997
@Comens1997 4 ай бұрын
lol dont reply me
@JyKrp
@JyKrp 5 ай бұрын
well this is not good. Hopefully the broken ones will be replaced soon
@mimi2
@mimi2 5 ай бұрын
Ayo amber strobes?
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
yes this was an important time sensitive upload other videos will continue with the regular posting schedule
@mimi2
@mimi2 5 ай бұрын
@@nics-systems-electric alright I'll keep my beak shut Very curious on what this is about >:3
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
@@mimi2 it's no secret it's posted for the world to see I'm just letting people know that it won't be featured in videos until their time comes around
@mimi2
@mimi2 5 ай бұрын
@@nics-systems-electric ah alright. I am quite excited
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 5 ай бұрын
im luckly I dont have a l series low frequency sounders so im not even affected by this
@nikbob0304
@nikbob0304 5 ай бұрын
Bro i only got a spectacular alert classic im fine
@RjsfireALA
@RjsfireALA 5 ай бұрын
I SEE SOMETHING NEW hint it is yelow and white
@dimitriberozny3729
@dimitriberozny3729 5 ай бұрын
Honeywell,stink and smell!,Honeywell!!
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Huh?
@alexandersalarms5380
@alexandersalarms5380 5 ай бұрын
Didn’t this already happen lol
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
Not with the system sensor ones maybe another brand
@alexandersalarms5380
@alexandersalarms5380 5 ай бұрын
@@nics-systems-electric I recall back like a year or two ago system sensor pulled the l series low frequency sounders off the shelves temporarily. I forgot why. But since this is happening now I think it could relate to this. I know this cause my boss sent out an email.
@joeycaridi3030
@joeycaridi3030 2 ай бұрын
@@alexandersalarms5380 It happened in 2021 due to the global chip storage from the COVID pandemic but however in 2022 the L-Series products were brought back
@RJARRRPCGP
@RJARRRPCGP 5 ай бұрын
"9112"= 2019? Day 112?
@joeycaridi3030
@joeycaridi3030 5 ай бұрын
It means: 2nd week of November 2019 "9112" the date numbers of the date code are as followed: First digit: The number of the year of it's last digit Second and third digit: The numbers of the current month Fourth digit: The number of the week of the month
@allisonmiller170
@allisonmiller170 5 ай бұрын
They should've made it five digits, but the last four stay the same they should've added one in front the current first one EX; 24032 to represent: (Numbers 1 & 2) for the last two digits of the year (Numbers 3 & 4) for the month (Number 5) for the week Just for easier things in the future
@joeycaridi3030
@joeycaridi3030 5 ай бұрын
@@allisonmiller170 Yeah like when it's 10 years after the release of the LED L-series because it's the last product line in order to avoid confusion with the years of the date codes
@superstar64
@superstar64 5 ай бұрын
System sensor L series durability test when
@nics-systems-electric
@nics-systems-electric 5 ай бұрын
If you want to pay for one
Fire In My Generator Building Fire Alarm System Smoke Detector Activation Test
15:31
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 20 М.
2024 annual garage fire alarm system testing
30:15
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 81 М.
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 16 МЛН
SCHOOLBOY. Мама флексит 🫣👩🏻
00:41
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 6 МЛН
Testing Both My Fire Alarm Systems, Backup Generator And Emergency Lights | July Testing
29:10
LED L series Fire Alarm on FWR power?
9:56
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 6 М.
Service Tech Life #3: NAC troubleshooting
7:20
Service Tech Life
Рет қаралды 6 М.
What happens if you connect Windows XP to the Internet in 2024?
20:35
Electromagnetic Aircraft Launcher
15:09
Tom Stanton
Рет қаралды 970 М.
Power outage emergency generator test simulation at high school #2
23:56
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 10 М.
Almost EVERYONE is Wasting Money on Dash Cams.
17:32
Linus Tech Tips
Рет қаралды 10 МЛН
System Test 21
14:20
FrostedStrobes
Рет қаралды 197 М.