No video

House Wiring | How To Select DB And It's Position How To Calculate Distribution Size |Tech hack work

  Рет қаралды 53,690

Tech hack work

Tech hack work

2 жыл бұрын

In this video I'm showing you how many electrical Distribution box need in an house, how to calculate it's size or space and where to install and more about house wiring.
There are many distribution box needs in an house but many people doesn't install the db while wiring, so it may cause to over consumption of electricity.
Your current electricity consumption is very high? and you want to decrease it?
Don't worry the video series helps you to decrease. please watch our previous electrical tips video and subscribe my channel for next updates. thank You
______________________________________________
Tech hack builders & Buliding consultant
പ്ലാൻ സംബന്ധമായ വിവരങ്ങൾക്ക് കൺസൾട്ടേഷനും contact me whatsapp
+91 80759 15003
_____________________________________________
Tech hack work.
For Business promotion and collaboration Interior and exterior consultation, designing and also To impliment Please Contact me through WhatsApp: +917736443452
LICENCED CONTRACTOR CUM SUPERVISOR
______________________________________________
To watch our electrical videos click link👇🏻 • HOUSE AND INDUSTRIAL W...
House wiring
wiring tips
Db selection
db position
number of db in an house
Distribution box
Distribution board
electrician
house electrification
before Plastering an house
house construction
latching relay
switch board wiring
switch board dressing
db wiring
pre wiring
best wiring materials
electrician
how to wire an house
electrification process
3phase wiring
single phase wiring
#techhackwork
#dbwiring
#dbselection
#threephase
#3phase
#single-phase
#housewiring
#homewiring
#modernhome
#electrification
#electrifying
#homeconstruction
#switchboardconnection
#dbwiring
#switchboardwiring

Пікірлер: 69
@noufalck1919
@noufalck1919 2 жыл бұрын
ഇതൃയും Deatil ആയി ആരും ഇതു വരെ പറഞ്ഞില്ല waiting for next part
@al_sabahiya_trading
@al_sabahiya_trading 2 жыл бұрын
Selector db ഒക്കെ ഇപ്പൊ ആവശ്യം ഉണ്ടോ,ഞങ്ങളൊക്കെ ഒഴിവാക്കി പിന്നെ ചില kseb എഞ്ചിനീയർമാർ വെക്കാൻ അനുവദിക്കുന്നില്ല,db cut ചെയ്തു പൈപ്പ് ഇറക്കിയാൽ ip rating നഷ്ടപ്പെടും പൊടി കയറി mcb, rccb ഒക്കെ കേടുവരും,dbyude കൂടെയുള്ള ഷീറ്റ് മാറ്റി വേറെ ഷീറ്റ് hollsaw cut ചെയ്ത് അഡാപ്റ്റർ ഇട്ടാണ് ഞാൻ ചെയ്യാറ്
@Nijinshalu
@Nijinshalu 2 жыл бұрын
Good
@prinujohnson2491
@prinujohnson2491 2 жыл бұрын
👍
@aswinrajs690
@aswinrajs690 2 жыл бұрын
ip rating ??
@al_sabahiya_trading
@al_sabahiya_trading 2 жыл бұрын
@@aswinrajs690 electrical,eletronics ഉപകരണങ്ങൾക് dust, water എന്നിവയിൽ നിന്ന് എത്രത്തോളം protection നൽകുന്നു എന്നതിനെ ip rating എന്ന് പറയും
@thestudio4583
@thestudio4583 2 жыл бұрын
that is the proper way
@hunaisk8481
@hunaisk8481 2 жыл бұрын
4:38 ഇൽ നിങ്ങൾ പറയുന്നു ഇൻവെർട്ടറിന് elcb വെച്ചില്ലങ്കിൽ ഷോക്ക് അടിക്കാനെങ്കിൽ പ്രൊട്ടക്ഷൻ ഇല്ല എന്ന്. അത്‌ തെറ്റാണ് ബ്രോ.... നമുക്ക് ഒരു phase വയറിൽ നിന്ന് ഷോക്ക് കിട്ടണം എങ്കിൽ അവിടത്തെ ന്യൂട്രൽ ഭൂമിയുമായി ബന്ധം വേണം. അത്‌ inverteril നിന്നായാലും ലൈനിൽ നിന്നായാലും. ഭൂമിയും ന്യൂട്രലും തമ്മിൽ ഉള്ള link പ്രോവൈഡ്‌ ചെയ്യുന്നത് kseb ആണ്. ലൈനിൽ നിന്ന് ഷോക്ക് കിട്ടുന്നസമയത് phase ലൈൻ elcb യിലെ ന്യൂട്രൽ അറിയാതെ ഗ്രൗണ്ട് ആവുന്നു ഈ സമയത്ത് elcb ട്രിപ്പ്‌ ആവുന്നു. ഇനി ഇൻവെർട്ടർൽ നിന്നാണ് ഷോക്ക് കിട്ടുന്നതെങ്കിൽ. ഇൻവെർട്ടർ ന്യൂട്രൽ same elcb വഴി തന്നെ ആണ് kseb ഗ്രൗഡിലേക്ക് പോവുന്നത്. ഇൻവെർട്ടർൽ നിന്ന് ഷോക്ക് കിട്ടുന്ന സമയത്ത് elcb യിലെ phase അറിയാതെ elcb ന്യൂട്രാലിലൂടെ ഒരു കറന്റ്‌ ഫ്ലോ ഉണ്ടാവുന്നു. ഇത് കാരണമായും elcb ട്രിപ്പ്‌ ആവും. പിന്നെ അവിടെ ഇൻവെർട്ടർ ലൈൻ ഉണ്ടങ്കിലും ഷോക്ക് അടിക്കില്ല. കാരണം ഭൂമിയും ന്യൂട്രലും തമ്മിൽ ഉള്ള ബന്ധം elcb ട്രിപ്പ്‌ ആയതോടെ വിച്ഛേദിക്കപ്പെട്ടു.
@Techhackwork
@Techhackwork 2 жыл бұрын
കഷ്ട്ടം, 😥
@ajithradhakrishnan894
@ajithradhakrishnan894 2 жыл бұрын
Super comedy.hahaha...
@bhagavan397
@bhagavan397 Жыл бұрын
@@Techhackwork കളി ആകുന്നത് മോശം
@arumughanks1177
@arumughanks1177 Жыл бұрын
What will happen during power cut ?
@Longlivethespam
@Longlivethespam 7 ай бұрын
Sheda.....😂 Shock adichal ale earthing vazhi leakage current poi snm trip ava.... Shock adikand enthin trip Avanm..... iyal ith enthod😂
@leegeorge9766
@leegeorge9766 2 ай бұрын
ബ്രോ ആ ഇൻവെർട്ടർ ബ്രേക്ക്കർ ന്റെ കാര്യമൊരു വേറെ വീഡിയോ ആയി ചെയ്യാമോ
@kareemkak3249
@kareemkak3249 2 жыл бұрын
Heater ok bathroom സർക്യൂട്ട് ഒക്കെ എന്തിനാ suprate വലിക്കുന്നത്... ഒരു xhost fan ഒരു led കൂടിപ്പോയാൽ 100w ഇതിന് കൊടുക്കാൻ പറ്റുന്ന MCB shopil കിട്ടുന്നുണ്ടോ...1A b curve ഒക്കെ കിട്ടുമോ... എന്ത് വാടെയ് ഇത് റോമിലെ sercute ല് തന്നെ കൊടുത്താൽ പോരെ
@mohammedmubashirpp6842
@mohammedmubashirpp6842 2 жыл бұрын
Heater avum
@musthafapnm
@musthafapnm 2 жыл бұрын
1A MCB kuttan und
@malluvibes1740
@malluvibes1740 11 ай бұрын
Plywood, അല്ലെങ്കിൽ മൈക്ക wood ഉപയോഗിച്ച് എന്ത് കൊണ്ട് db ഉണ്ടാക്കികൂടാ... ഇത്ര വില കൊടുത്തു db വാങ്ങുന്നതിലും ലാഭകരം ആണോ
@sh_1270
@sh_1270 2 жыл бұрын
Ethanu best electrical wire ? Athinte video undo? Polycab or RR kabel?
@Techhackwork
@Techhackwork 2 жыл бұрын
ചെയ്യാം
@MyWorld-ok4sy
@MyWorld-ok4sy 7 ай бұрын
THANK YOU SIR
@chejusworld2444
@chejusworld2444 2 жыл бұрын
12 way db യെ കുറിച്ച് പറയാമോ
@sheebajacob470
@sheebajacob470 4 ай бұрын
Living areyayil vachal problem undo
@akbarakkuakbarakku6810
@akbarakkuakbarakku6810 Жыл бұрын
Super adipoli
@sarathkc6563
@sarathkc6563 Жыл бұрын
DB outer wallil vechal kuzapindo?
@Techhackwork
@Techhackwork Жыл бұрын
ഇല്ല
@abhinandhsachinps4502
@abhinandhsachinps4502 Жыл бұрын
Does the size of the DB changes accordingly with the home
@josephs35
@josephs35 2 жыл бұрын
Super
@mithunmathew6221
@mithunmathew6221 Жыл бұрын
👍
@joysonrappai1408
@joysonrappai1408 2 жыл бұрын
Nigalude place avideyanu Ente veetile earthing onnu check cheyyananu
@arttechy1573
@arttechy1573 2 жыл бұрын
👍🏻👍🏻
@abrahamthomas2054
@abrahamthomas2054 2 жыл бұрын
What is the use of 3rd DB
@muhammedadil4463
@muhammedadil4463 2 жыл бұрын
👍👍👍🔥
@rizwanarizuvlog7846
@rizwanarizuvlog7846 2 жыл бұрын
Tpn 8way db with out selector which model suitable pls answer !
@muhaiminpt3960
@muhaiminpt3960 19 күн бұрын
SCHNEIDER
@sajithpullikkattil
@sajithpullikkattil 3 ай бұрын
Separate db veno inverter inu
@navas....6418
@navas....6418 2 жыл бұрын
👍👍👍
@asherafworld9037
@asherafworld9037 2 жыл бұрын
Db ബാത്‌റൂമിന്റെ wall ൽ വെച്ചാൽ prblm വരോ. കിച്ചണിന്റെ അടുത്തുള്ള ബാത്‌റൂമിന്റെ ആണ്
@jaindevasia4585
@jaindevasia4585 Жыл бұрын
SERIKKUM PARANJAL VEKKAN PADILLA
@vishnuflowers2690
@vishnuflowers2690 2 жыл бұрын
SPD vekkunnath mainswitchinum meter num idaykkano അത്‌ supply line നു parallel connected aano
@JAG_UAR
@JAG_UAR Жыл бұрын
After meter
@MrSanish2
@MrSanish2 2 жыл бұрын
Ethellam sq mm ethellam points use cheyyanam oru video cheyyumo
@noufalck1919
@noufalck1919 2 жыл бұрын
Good request please consider 🙏
@anooppnair5871
@anooppnair5871 2 жыл бұрын
Main elcb trip ayal inverter nu vechirikunnna elcb trip akumo ?? Main neutral cut ayipokumo??? Rply plz
@krm4188
@krm4188 2 жыл бұрын
Erth leakage vannal randum trippakum
@MyWorld-ok4sy
@MyWorld-ok4sy 2 жыл бұрын
THANK YOU VERY GOOD BRO
@unnikarithalackal8895
@unnikarithalackal8895 2 жыл бұрын
തേപ്പുകാരൻ പണിതന്നാലോ. ടോപ് ബോക്സ്‌ വച്ച് 6ഓ 7ഓ പൈപ്പ് താഴെക്കിറക്കുക. റീ ഡ്രസിങ് ടൈമിൽ ഉപകാരപ്പെടും
@sum2473
@sum2473 Ай бұрын
DB consealed ആയി തന്നെ ചെയ്യണമെന്നുണ്ടോ? Consealed ആക്കാതെ വച്ചിട്ട് ഒരു ചെറിയ cupbord ചെയ്യാനാണ് ഞാൻ ഉദ്ദേശിക്കുന്നത്... ഇതിൽ എന്തെങ്കിലും കുഴപ്പം ഉണ്ടോ? വെറുതെ ഭിത്തി പൊട്ടിക്കാൻ താൽപര്യം ഇല്ല..അതാ...
@saraththebigboss
@saraththebigboss Жыл бұрын
eethe db box aayirunnu videoyil kaanichathe
@jasaeeljaa7353
@jasaeeljaa7353 2 жыл бұрын
👍🥰🥰🥰🥰🥰
@JayanPP-jy4tr
@JayanPP-jy4tr Жыл бұрын
What's the
@shibuv413
@shibuv413 2 жыл бұрын
Party rupa mutakkumo
@noufalck1919
@noufalck1919 2 жыл бұрын
Bakki vedio evide
@nishadbasheer85
@nishadbasheer85 Жыл бұрын
രണ്ട് rccb വെക്കുമ്പോൾ ഇൻവെർട്ടറിന് പ്രത്യേകമായി സർക്യൂട്ടിലേയ്ക്ക് ന്യൂട്രൽ വലിക്കേണ്ടതുണ്ടോ .
@midhunk7625
@midhunk7625 Жыл бұрын
Yes
@jassirjasi5657
@jassirjasi5657 2 жыл бұрын
എന്തിനാണ് നിന്ന് സംസാരിക്കുമ്പോൾ മുന്നിലോട്ടും പിന്നിലോട്ടും ഇങ്ങനെ ആടുന്നത്?
@Techhackwork
@Techhackwork 2 жыл бұрын
അനങ്ങാതെ നിന്നപ്പോൾ പോസ്റ്റ് പോലെ, അനങ്ങിയപ്പോൾ ഇങ്ങനെ 😥😜
@ameeralicp
@ameeralicp 2 жыл бұрын
@@Techhackwork 😀😀👍
@sejatpatel5457
@sejatpatel5457 2 жыл бұрын
Hindi me video banao mera bhai pls
@Techhackwork
@Techhackwork 2 жыл бұрын
🥰
@mithuna.j1671
@mithuna.j1671 7 ай бұрын
ബാത്‌റൂമിനു എല്ലാം കൂടി ഒറ്റ mcb മതി 30amp mcb വെച്ചാൽ മതി ഇത് ചുമ്മാ പണിക്കാർക്ക് പൈസ പിടുങ്ങാൻ ഉള്ള തട്ടിപ്പ്.. റൂമിനു എല്ലാം കൂടി ഒറ്റ mcb മതി power plug വരുന്ന സ്ഥലത്തു മാത്രം ഓരോ ഓരോ mcb വേണം
@sajithm.v1955
@sajithm.v1955 Жыл бұрын
👍
@muneerm1469
@muneerm1469 2 жыл бұрын
👍
My Cheetos🍕PIZZA #cooking #shorts
00:43
BANKII
Рет қаралды 24 МЛН
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 24 МЛН
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 2,9 МЛН
Single Phase House Wiring Diagram / Energy Meter / Single Phase DB Wiring
4:55
SL Engineering Academy
Рет қаралды 765 М.
RCCB Tripping ശരിയാക്കാൻ പഠിക്കാം.
15:53
BS Electrical Solutions
Рет қаралды 61 М.
3phase DB ശ്രദ്ധിക്കേണ്ട കാര്യങ്ങൾ
8:31