It is not the size of house that matters, but the load in the house. This setup is not for AC but bulbs, fan and TV
@abisaiamatalo27695 ай бұрын
This is a Lithium Iron Phosphate (LiFePo) battery pack. It has many batteries inside connected in series-parallel configuration, and inverter chargers. This is very common here in Kenya in Off grid connections. There is nothing difficult here. Anyone who has an electrician diploma or certificate can do its wiring. For the above video, the hotel has energy saving bulbs, Probably LEDs, Phone charging sockets. The AC is probably connected to a few rooms.
@danielekweo.97705 ай бұрын
Critically analyzed by you..
@FunWheelsfrenzy4 ай бұрын
That guy is just talking as if he does not know that solar power professionals will see this video . This video just show a high level of ignorant
@LexionKing5 ай бұрын
You keep dissing the Generators and Transformers. Oya power all the ACs in the 32 Rooms with your 17.5KwH battery and 10KVa inverter na. Why you put only 3? 🙂 Do you know how many thousands of Kilowatts are consumed daily either through Grid Power or Heavy Duty Generators ? The inverter setup to do that will make the Transformer and Generator Prices a Joke. And for your info, 70% of the Daily Power consumption of that Hotel are the Air Conditioners. That's a necessity before most customers pay for a Hotel room anyways. So, the inverter is good, but certainly still needs major help from the Generators
@miltonchadwick5 ай бұрын
Don't mind the liar!
@peterigwilopi5 ай бұрын
Liar? The owner is saving money because he's using both the solar and generator alternatively@@miltonchadwick
@GTdontDOthat5 ай бұрын
d amount to power all d ac and all d load na better money .all dis can only power d light load in day time
@topreviews76905 ай бұрын
Yeah, that does not make any sense 17kw will only run a home a normal American home for half a day 12 hours hours much less run 38 rooms and especially on that single inverter stop playing games on the KZbin
@adamstaiwo77795 ай бұрын
😂😂😂😂😂😂 naija my country haba 17.5kw how for where with a/c no way pls it only for lighting and fans in the rooms dey have guess not all unless you make the battery 🔋 like 30/40kva that will power all the rooms lights and fans successful including the bar for some hours not all days for the a/c you still need the generator
@donptv4335 ай бұрын
14 solar panel is @500 watt is 7000watt =7kw. @32 rooms with lightning ⚡ point and air conditioning @1.5kw. what is the battery capacity. In conclusion the solar panel and battery is not fully for the load
@GTdontDOthat5 ай бұрын
also note 500watt will never produce up to 500watt
@shizzysmith25145 ай бұрын
Anybody that give this one job he do enter trouble
@blessingsunday52723 ай бұрын
@@shizzysmith2514 😂 😂
@relaxationstudio12705 ай бұрын
This is an hybrid inverter but, they don't use it that way..... This one can light up the hotel energy saving bulbs and some small loads.... Battery determine the backup time. That battery can last on bulb only and few load. Average house uses about 50kw of power per day not to talk of an hotel..... If you know about inverter, you know.... The cost of that inverter pass those generator
@danielokwum2485 ай бұрын
It is apparent most installers don't really understand the basic numbers when it comes to renewable energy. If conservatively, all rooms uses a 5 units of 5watts bulbs, 40 inches tv, tge table top refrigerator, the hotel's low voltage equipments, etc. Your run time on that battery alone might not exceed 2 hours. This battery DOD of discharge is at 80%.
@Swit-Elect5 ай бұрын
Don’t mind the Olodo. He said 17.5KWH is equivalent to 15 220ah tubular batteries. 4 batteries is 10KWH. 8 is 20KWH. The DOD of the lithium battery IS 98% compare to tubulars. Which is at most 50 to 70% DOD
@outtersteller5 ай бұрын
@@Swit-Electalthough he isn’t accurate but he isn’t wrong either, people often forget tubular batteries has a usable capacity of 50% Which means 15 12v 220amps is likely 19kw... and that’s without factoring the mixture of parallel and series connection to get a 48v architecture ....
@GTdontDOthat5 ай бұрын
maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night
@michaelakomolafe92495 ай бұрын
@@Swit-ElectThey are just creating content for the ignorant.
@eddyemmanuel5125 ай бұрын
See lies 🤦♂️ 17.6kw system for this hotel Bros fear God o. Believe this at your own risk ⚠️
@GTdontDOthat5 ай бұрын
maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night
@beejsplacegamesloungelagos51575 ай бұрын
@@GTdontDOthat Almost all the info is wrong,you can list the size of an apartment as and estimate of power or duration of the power supply,the whole of sheraton if not a single bulb or electrical item is on will consume 0kw a year while a container with bitcoin miners can consume 10 kw a day..A lot of the info there are just upside down.
@GTdontDOthat5 ай бұрын
@@beejsplacegamesloungelagos5157 i also use solar.d thing surprise me and i say maybe na only day time wen d panel dey produce power
@wazitech57282 күн бұрын
At work wow even two bedroom will smoke all this out with working everything under just 6 to 7 hours
@ArrèyJAE5 ай бұрын
"They fit seize light, they no fit seize sun" legendary words my bro. Solar is the future in deed.
@ChristainCExcel5 ай бұрын
😂😂😂 SUN IS NATURAL BY GOD.
@michaelan1395 ай бұрын
sun de seize every night
@GTdontDOthat5 ай бұрын
@@michaelan139yes light in my area na rain every day
@KD-tp7cg4 ай бұрын
What guys don't understand is if the rain keeps failing every day like the 1 week, the sun is nearly out and less charge is stored, we have to make use of Nepa to charge. Nepa even charges the batteries faster than the sun
@yungpass15 ай бұрын
One of the generators can power the whole hotels both the ACS but the solar can not power quarter of the ACS. Just the play
@ikpalian44135 ай бұрын
I can only accept this, if is carrying critical load during off grid with energy saving bulb in the 32 rooms❤. Try on any heavy appliances if they will not call u back.
@wazitech57282 күн бұрын
Just for lighting only I will accept this works but for other things now never if it is the fancy type like pop type I will accept fully but with other things water heater is he joking
@OmosagbaKoleIsraelResonance4 ай бұрын
This solution is easier said than done. Let wait for the next 6-12 months
@juniorjohn49012 ай бұрын
THIS MAN NA LION OOO...
@wizlipskings89585 ай бұрын
1 water heater pull 2000 to 3000 watts of power , so imagine 3000watts x 34 rooms 102kw of power and u have 17kw. This can last 1hour if you give this hotel full load, imagine, tv , fan at max , at night it wont last ...at all
@GTdontDOthat5 ай бұрын
maybe it power only light load like light,tv and fan in d day time wen d solar is producing.dis cant carry d hotel at night.not possible
@wizlipskings89585 ай бұрын
@@GTdontDOthat yeah , but his video made it look like it will sustain the loads , especially at night.
@anyiegopatricks18695 ай бұрын
Nawao 😮
@wazitech57282 күн бұрын
He Is a dummy making people think rubbish
@charlestoniwuagwu37872 ай бұрын
I lost your contact. I appreciate the good Job that you are doing and want to discuss further with you. Be safe
@ClementElectrical115 ай бұрын
Good work my brother but all the Air conditioner won’t be on all the time there’s a load separation on the Distributional board
@justusmarthin8535 ай бұрын
The iron battery is like how much in naira for those who are interested but stay abroad Please can someone inform the correct amount of iron battery for solar
@greattom36055 ай бұрын
Hey Daddy you can lie ooooo😂😂😂😂😂😂😂😂😂
@ashestoashes69025 ай бұрын
😂😂😂😂😂
@shizzysmith25145 ай бұрын
HIs just saying rubbish
@heywireutilityelectricalАй бұрын
😂😂😂
@profprof58165 ай бұрын
Why would the battery be in operation during the day when the sun is at its fullest energy? The battery should be charging and automatically goes off if full. During the day, power should be from the solar to inverter and to appliances. At night it should be from Battery to Inverter and appliances.
@mamaosun35872 ай бұрын
The battery will only work at night, from 6:30pm
@2bor2bam2 ай бұрын
Na watin I don hear be this but never see who do am na so dem take kill my 8 batteries
@imonikhebraimoh71915 ай бұрын
as a solar installer, this is complete deceitful. First off, low customer patronage is causing load consumption to be minimum. Technically, if each room consumes just 200W, and all rooms consume that, power consumption= 6400w. then how long will that battery last? Also, the controller looks like an 80W controller which means max. solar power is about 3840W. what he is saying is incoherent.
@asikaohadike89935 ай бұрын
The entire installation is a 20Kva with 17.5Kwh Lithium Backup, you can not run more than 5 Air-conditioner on this entire system. My concerns lie more with how many Good weather / sun hours Benin has in a year.
@GTdontDOthat5 ай бұрын
even with good sun.this cant power d hotel at night
@crimeandcontroversy90425 ай бұрын
how much does ot cost
@uzochukwujustin64525 ай бұрын
Haba Bros. How he gontalk say that 17kwh na like 15 of tubular. 4 units of 220ah tubular is approximately 10.5kwh meaning that 8 of it is 21kwh. How 15 u it's come take be 17kwh. Nawa o 😂
@seunsonoiki69795 ай бұрын
from tubular batteries , you can only use 50% of its rated capaccity for a longer life span.
@uzochukwujustin64525 ай бұрын
@@seunsonoiki6979 that the theory on paper. But have you compared both side by side? Cause I have. Put the same load on each and record the time it takes to completely consume.
@oluwatoyinjegede33485 ай бұрын
U KNOW EDO PEOPLE LIKE EXAGERATION NAH
@kenazuka75215 ай бұрын
Good! If 8 tubular is approximately equal to this one 17kw lithium.. lithium is always times 2 efficient that it's equivalent tubular battery because of the DEPT OF DISCHARGE
@Dr._Aniekan_udo5 ай бұрын
Have you heard of 100 ah tubular battery too? And have you heard of discharge efficiency? 98% discharge efficiency is not same as 50% to 60% discharge efficiency. So he is not far from being correct. Each 200ah tubular battery is 2.6kwh, but you can only extract 1.3kwh to 1.56kwh from it. And if you want it to have a longer lifespan you should avoid full discharge. With expert standard suggestion of 50% discharge you are left to use 0.65kwh to 0.78kwh. You can use the full 1.56kwh if you don’t mind. For LiFePo of 17kwh you can have up to 98% extraction, which give you 16.7kwh So for the most efficient ones (60% eff.) tubular in full usage is 11*200 ah = 17.16 kwh Tubular in Lifespan mindful usage(50% cap) 21*200 ah = 16.4 kwh I have a 1.2kwh LiFePo and have don reallife test using my friends 2*200ah tubular battery which is 4.8kwh. My friend had to change his tubular battery after it became very weak in 2 years. Also he does maintenance check every 6 months, while I haven’t done any. Lifepo4 only drops by 80% in about 4 years. Another benefit I discovered was that LiFePo battery also charges faster, even when sun shine is weak like this time that we are having rainy season.
@GTdontDOthat3 ай бұрын
the only person wen dey use one battery to power full hotel.crazy boy
@OssyOssy-hs6zf3 ай бұрын
14 piece 500watt for one charge controller. Well done,
@kaseamate90805 ай бұрын
Luckily for you to say it was only for 3 AC and other lighting points. Lol, i was expecting you to say the system will power all the AC in that hotel, and mind you the 14 sets of 500w solar panels won't be enough for this system and the Battery won't get enough charge from them if you're using the system on daytime. Well nice job
@GTdontDOthat5 ай бұрын
me alone i dey use 18 units of 625 halfcut panel.not to talk of hotel with many rooms
@chukwuemekaegbuonu66954 ай бұрын
This installation can only run 1 air conditioner all though the night.
@surajudeenayoola45915 ай бұрын
It can carry the load of fan, bulbs but not Air conditioner
@MrBenMedia20224 ай бұрын
One battery can't serve the entire hotel, for a house it's ok, though it's possible to power that hotel with solar energy 100% but the owner of that hotel needs to invest more in it.
@nwaaba17785 ай бұрын
Make person babe/wife/husband show face for this video. You go explain tire...😂
@shookoneldn3005 ай бұрын
😂😂😂
@ashestoashes69025 ай бұрын
😂😂😂😂😂😂
@oluwoleodetola16265 ай бұрын
Solar can be good but not reliable........Nigeria fixing it's electricity challenge is still the best.
@seunsonoiki69795 ай бұрын
its reliable if properly designed
@oluwoleodetola16265 ай бұрын
@seunsonoiki6979 lol You only run on solar?? You don't use Nepa anymore??
@GTdontDOthat5 ай бұрын
wetin u dey talk.i get 18 units of 600watt half cut panel with 12 unit of 230ah battery.my solar dey work well with 3 inverter ac.2 fridge.4 big tv.micro wave.washing machine.pumping machine and many more .my solar dey generate 4000watt wen weather bad and almost 10000watt wen sun dey.spend good money on solar and enjoy but not for hotel bcos d rooms many but can power few load wen sun dey
@elvisgregor84035 ай бұрын
Nigeria electricity can never be fixed.. Even one presidential aspirant owns mikano Gen 😅
@krayonnesilva3905 ай бұрын
I only run solar in my house and it's very reliable
@GTdontDOthat4 ай бұрын
see d way he hold d company magazine as if he know wetin he dey do
@emmank37105 ай бұрын
Hw much for this system
@johnvincent49935 ай бұрын
It is good that the talkshow is promoting the guy but i being a pro in solar system, there are more things not said than said. I rest my case
@GTdontDOthat5 ай бұрын
u dont need to be solar pro to know dis cant power d hotel well
@elmultimediaschoolofartscu39244 ай бұрын
❤❤❤❤ Brother, for an African i congratulate you, don't focus on negative ernegy. People in Africa don't like to share knowledge 😢😢, keep going brother. I learnt a few things from you 😊😊😊❤❤❤❤🎉🎉🎉🎉 🥳
@GTdontDOthat4 ай бұрын
dey play and believe rubbish
@okwydes87834 ай бұрын
MUMU, this trash he's talking is the knowledge you wan learn 😂😂😂
@charlestoniwuagwu37875 ай бұрын
Great Job and awesome information. How may I reach out to you. Be safe
@Theedotalkshow5 ай бұрын
@Charles. His numbers are displayed at the bottom of the screen
@OjibaMario4 ай бұрын
One 17.5kwhr battery can't give you 15 tubular battery.. Mathematically one tubular battery is 2.64kwhr(12*220) multiplied by 8 that's about 21kwhr.. The advantage lipo battery has is better BMS, ease of maintenance, life span so one 17.5kwhr can never be up to 15 12v 220ah
@krayonnesilva3905 ай бұрын
I believe those rooms have fans and not ACs but solar is the way to go like he said.
@GTdontDOthat4 ай бұрын
u nor see ac? this cant power it
@electricvehiclesug2564 ай бұрын
Forsure solar is the way
@simonjackson34814 ай бұрын
As a design Engineer who have designs countless commercial and industrial and commercial projects around sub Saharan Africa, I would say that this is simply an over exaggeration.
@CharlesIjewemen5 ай бұрын
Ordinary 17.5KWH battery, this boy de lie sha. I use 2 x 17.5 and 30 550 panels for 4 beds duplex and I cannot on all the AC's. You guys should take this video down.
@alarapeedrees29035 ай бұрын
❤😂🎉 well try
@chigozieandrew44584 ай бұрын
15kva inverter is almost about 8 to 10million How much is the milkano generator?
@bitlebron88015 ай бұрын
What about AC's in the hotel rooms?
@GTdontDOthat5 ай бұрын
dis can't power all d ac
@jesuslover18964 ай бұрын
Lol. Ignorance is a bad thing. I have 15kW panels paired with 54 kWh of batteries. This system is nothing, and keep in mind it's all about load. No way this is running ACs. Probably just lights and fans.
@nedeosaretin40645 ай бұрын
I don’t think this boy is an installer or he’s new to the business and wants to mislead potential inverters owners.
@TrishaPreshy16 күн бұрын
That means we don't need nepa or generators again shame on federal/state governments 😂
@Engineerizo5 ай бұрын
This guy is here to make video but me as an Engineer he should not deceive people around YES SOLAR IS GOOD BUT DO THE Math 17500x80% D. O.D Depth of discharge=14,000w Divide 14,000w by 12hr example of full run time =1166.6w/hr Divide 1166.6W/HR by 32 rooms that is avarage of 36.45625 w/hr for each room Do you think this is true each room can consume approximately 37W for 1 hr NO THAT'S A LIE 🛑
@bencoinstitute5 ай бұрын
This is mis information shaa
@degreatcornelius52925 ай бұрын
You no tell us how much 😊
@obinao.o5819Ай бұрын
Oga how many ac can this carry? no be to de talk talk
@mikelo_GIL4 ай бұрын
that system will only power light bulbs, TV and fans for some rooms
@stephensunday70485 ай бұрын
Solar is the way but your 20kva is not enough,I did something like this for my client but with 2pcs of 17kw lithium battery, that's for a person house o,how much more of this with only 1pcs of 17kw battery for hotel of 32rooms
@GTdontDOthat5 ай бұрын
u fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night
@EGBEAlpha5 ай бұрын
🤣🤣🤣🤣 everyone they do solar believe at Ur own risk is lies 32room how many watts per room big lies
@GTdontDOthat5 ай бұрын
only my house dey us 20wh not to talk of hotel
@GTdontDOthat5 ай бұрын
many will surely believe
@kenazuka75215 ай бұрын
😂😂😂😂... Depending on wetin de inside those 38 rooms oh.. maybe just 38 fans and 38 10watt lights bulbs and maybe 8 fans. E non go carry 38 ACs oh
@FTaiwo15 ай бұрын
How many air conditioners can this power and for how long?
@oladejosolomon21864 ай бұрын
It depends on the ac horse power and if its inveter ac then that even better.
@Tonyben15 ай бұрын
Them will bill you so that ur mind nor dey again
@IjeomaVictor.N-ld7nn5 ай бұрын
Baba why na😂😂
@engineervictorakpoghene96375 ай бұрын
Why promote something like this.... Every single talk Na nonsense 🤦♂️🤦♂️🤦♂️🤦♂️🤦♂️
@peteradams88564 ай бұрын
please stop deceiving people, how can you say 17.5 kw lithium batteries is equivalent to 15 tubular batteries? it approximately 6-7 tubular batteries, and mind you that system cannot power 3 unites of 1.5 hp ACs at the same time , even in peak periods
@BB_KUMBO4 ай бұрын
220AH tabular battery = 2.64 KWH x 7 = 18.48 KWH. Do the math and compare it to what he is saying. No one is doubting the quality of lithium ion battery but say 17.5 KWh is equivalent to 15 tabular batteries is a big lie
@enyichukwudi10265 ай бұрын
Pure lie. Una no dey ever talk true
@GTdontDOthat5 ай бұрын
if he say na only for day time we for believe small if dem remove some load
@obichukwuebukajames12094 ай бұрын
I want wind and solar in combine
@Idemudia-pk2ob5 ай бұрын
Whyy you dey mouth wash the generator and transformer na.. like say na you manufacture the inverter and battery 😂😂 na wah oh
@Oliviakitchen20234 ай бұрын
Pls , am installer always tell the truth when it comes to solar installation. What you are saying is not correct. I jave use 25kwh felicity battery up to 6pcs giving us 150kwh backup. Pls stop telling lies on solar installation. It works not the way you are saying.
@waliumoshood94054 ай бұрын
Don't mind the guy. Na so Dem go put people for problem after investing so much resources into the project.
@OyewoleDokun2 ай бұрын
Your design sizing were wrong
@onimisilovesonmusic454827 күн бұрын
A system just for light and tv
@titochineke12365 ай бұрын
You dey whine for 32 hotels. Unbelievable
@musajarjusey61324 ай бұрын
My friend this not possible,can power not more that 2hs.
@CovenantChisom5 ай бұрын
Is better for me to buy a 350kva soundproof than this solar system,350kva can power all the 32rooms and everything.
@adewumisesan265 ай бұрын
Ole
@egbunonworjoshua44113 ай бұрын
Guy this is wrong na, how can you power hotel with 17.5kw battery. It won't last long na. Is not about now but how long. Check the watts of Every bulbs, fans, tvs, small fridges this is 😂
@chigozieandrew44584 ай бұрын
Naso... No be only 12hrs Stop cappin on youtube biko.
@electrowashyelect97154 ай бұрын
Not serious u are just talking about 300ah x 4pcs of 12volts battery for lithium batteries. A 240ah 12v x4 pcs or 5 pcs or 150ah x 8pcs is still not bad ad equivalents ,but you have over promised what can not be achieved. Sorry for ur self if anybody does copycat of this poor design and over promised.
@oliverndubizu43605 ай бұрын
A just watching movie
@Tonyben15 ай бұрын
If you call them na their will not attend to you probably
@urchman74755 ай бұрын
Solar is the best way
@beejsplacegamesloungelagos51575 ай бұрын
So much misinformation in one vid
@GTdontDOthat5 ай бұрын
maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night
@charlesekpima82105 ай бұрын
It can not power the hotel even in day time with AC or water heater @@GTdontDOthat
@jollyuwu81883 ай бұрын
Me I need mooo
@okwydes87834 ай бұрын
MUMU keep deceiving yourself
@stanleyeyube935616 күн бұрын
You are supposed to be arrested this you're scamming
@Martinmartin-ix2cq4 ай бұрын
His explanation is wrong 😂
@peacenathaniel64484 ай бұрын
This is scam ooo This one battery cannot carry all the equipment in the hotel, it can carry the lights, tv and other small loads That battery is 17.5kwh and it is equivalent to 7 tubular batteries, this battery can only accept and give out 6kw of power and the hotel on full load is more than 25kw which invalidate his claim A typical household in Nigeria consumes about 0.75kw power to power basic appliance in the house ; an average house in Nigeria needs 4 tubular batteries, 5kw Inverter and 4kw of solar power to run smoothly. This guy is talking rubbish because if this is true, almost all hotels in Nigeria would have switched over to solar. Solar is very expensive to install, but cheaper on rhe long run. Your favorite installer.
@samgongelectronics37615 ай бұрын
I am an electrical engineer from Cameroon system of 500-watt of 14 solar panels can supply: -Total DC Power = 7000 watts - Total AC Power = 6300 watts (considering 90% inverter efficiency) -Daily Energy Production = 25.2 kWh to 37.8 kWh (depending on 4 to 6 peak sunlight hours) They can support a continuous AC load of up to 6300 watts under optimal conditions. I think you should be talking more about power consumption in DC using LED lights bulbs of between 5w to 15w each. your system cannot support More than 4 air-conditioners of 1.5Kw each.
@GTdontDOthat5 ай бұрын
solar panel will never produce their rating.a 500watt will never produce up to 500watt
@FunWheelsfrenzy4 ай бұрын
Oga Where did you learn your Solar power installation .If you only know about led acid and gel Batteries limit your self to that please . Do not talk about Lithium batteries if you do not know what you are talking about . Do not mislead innocent people please .
@leononi81944 ай бұрын
No no no 17 kWh battery 🔋man all your explanation done make no sense
@ogidz-xix4 ай бұрын
Another Click bait video. I stopped watching after a minute
@abdulhalimibrahim48264 ай бұрын
This Man is LYING I SWEAR, this Lithium Phosphate has the power of only 7 tubular batteries, The Inverters on the wall are 10KVA inverters, how can 20KVA be enough for at least 38 pieces of 1HP ACs? miserable liars. and how can these small breakers and changeover be enough for 38 hotel rooms? fear God my brother.
@xlgoldfish4 ай бұрын
I hate to see such videos like this. A 2kwh battery can power only light bulbs across a 32 room hotel. This guy is a fraud that is telling people half truth. What exactly is this system powering?
@EngrVick3 ай бұрын
This is guy is not learned enough how can you say that one of the battery is equivalent to 15 tubular batteries.. drop your calculations here show proof if you know your job However 17.5kwh cannot even power 35% of this Hotel load. Well you later said you only connected 3 air conditioner which can’t even be used simultaneously with other loads, why the initial bragging? Everyone seeing this video please be aware that even 100m cannot be enough to installed a solar system that can power at least 85% of this hotel load. Your connection is improper.. installation of 15kva (10kva & 5kva) to be manually operated. Hmmm Edo talk show keep posting unqualified installer/Engineers