Heya Jason, I've got a lopi pioneer pellet stove. I got it used last year, a lot of the components have been replaced. new squirrel fan and blower motor. The augur stopped turning. bought a new augur motor- still nothing. The manual switch, doesn't engage the motor. We've been trying to chase down the vacuum sensors and wiring but are at a loss as to what else might be causing the issue. So- what can we check or test to figure out where the breakdown is. The fuse is intact and the wires themselves seem mostly ok. and what would be a mother board problem and how to test that?
@harrydoherty82993 жыл бұрын
just to add , i got a static zap when i touches the start button a few months ago . the erratic behavior started after that . stove is a breakwell p 22 . i have a new board on order .
@tonydem195229 күн бұрын
hi your videos are very good. I have a weird problem with my Harman Accentra insert. After my pre season cleaning the stove combustion motor turns on when i plug it in but the switch is set to off. Could this be a control board issue?
@playingwithfire203828 күн бұрын
That would more likely be a low limit sensor which usually is mounted to the exhaust fan. It has two wires going to it. With the stove unplugged, disconnect one of the wires. Plug the stove in and the fan should not turn on.
@tonydem195227 күн бұрын
@@playingwithfire2038 thanks for the reply but i have a harman accentra insert from 2008. i believe it's a 52i. Not sure though. I don't think it has a limit switch. It does have an esp though. could that be the issue. I did clean it. Thanks for the help.
@douglassummers2211 ай бұрын
Jason,I have a Golden Eagle stove (Breckwell) now U.S stove A-E-401GE circuit board , My issue is I had a fan plugged in the same outlet and I tripped over the cord of the fan and it pulled the wires out of the box-fan and sparked the wires on the fan,but it also blew my circuit breaker and now the stove won't turn on ?Did I Blow the circuit board or ?? please help if you can !
@JASONRICHARDMunson11 ай бұрын
You may have just pulled the power wires from the stove. Check that first, make sure power is getting the board. If it is and it's not working, we can repair the board....www.pelletstovepro.net/Repair-Service-for-Breckwell-Digital-Pellet-Circuit-Board-w-1-YEAR-WARRANTY
@michaelstill799311 ай бұрын
Hey Jason, tried to start my Whitfield Advantage WP2-III last week. Heard a slight “pop” when pressing the start button and nothing turned on. Replaced the control board fuse and checked breakers. Now getting no response from board at all.
@JASONRICHARDMunson11 ай бұрын
Your control board is bad. We can fix it....www.pelletstovepro.net/whitfield-advantage-plus-pellet---whitfield-advantage-plus-control-board---whitfield-advantage-plus-circuit-board-71
@sunsmile57 Жыл бұрын
DEAD,DEAD,DEAD..I have Enviro Empress FS, my combustion fan stopped working. While I was troubleshooting I popped the circuit board, changed the fuse…nothing. I order a circuit breaker but no juice. I tried what you said about disconnecting all the motors then adding them back no juice at all. I have been a pellet stove user for 10 yrs and this is the first time this as happened. Maybe I need a new wire harass or Do you think they sent me a bad circuit board..is there anyway of testing any thing. Nothing is working😮
@brianfox4284 Жыл бұрын
Hey Jason. I have an englander pellet stove. It works fine when you first light it. Flame goes up a bit, then down a bit as normal. After a while, it starts feeding crazy and stove gets super hot even with it in d mode and it's set 1 5 1 on advanced settings. Heat range on 2 and blower speed on 7. Any idea why this is doing this?
@JASONRICHARDMunson Жыл бұрын
I would replace the temp sensor. You have to get those directly from Englander.
@jeffwilliams72032 ай бұрын
How much do you charge for a pelpro 130 B rebuilt control board
@Proatcod103 жыл бұрын
I have a lopi was working great then a power surge happened . Won’t turn on . I replaced the fuse on circuit board n nothing . No lights nothing no power at all any idea what happens ?
@lafrancois63234 жыл бұрын
Thanks for the info, it confirmed my suspicion of the control board since it's completely dead. Got it started after not running for years, next day nothing. I have a bosca 500 spirit, haha yes I know. I would have loved for you to repair it but a new one is $220 and you charge $250. Is this still accurate?
@nicholasstarkweather75139 ай бұрын
My advance model stove doesn’t allow me to remove the panel it’s all built in… how do I do this??
@lessasue4 жыл бұрын
Hi Jason First THANK YOU! I have an Europa 75 Dell-Point stove. I keep getting codes F5 & F6 when I start it. I have checked the fuses and wires all is good. I thought it could possibly be the control board but after watching this I am doubting my diagnoses. I have removed and cleaned the augers and stove. I am at a loss. Suggestions?
@JASONRICHARDMunson4 жыл бұрын
I've never worked on that stove and I don't know what those error codes mean. If you have the manual and can tell me what those codes are for I might be able to help.
@lessasue4 жыл бұрын
Thanks for the reply. F5 Problem-- Auger feed motor fuse blown; Solution- Clear jammed auger and replace fuse. F6 Problem-Auger ash extraction motor fuse blown; Solution--Clear jammed auger and replace fuse. I have done both. I get power and blower fan just can not get rid of codes and feed auger to drop.
@mcross3203 жыл бұрын
Jason, I have an Avalon Avanti Ps stove. It wasn't feeding properly , cleaned it all inside and out , test motor ok, now nothing. Thinking circuit board problem? Mark
@JASONRICHARDMunson3 жыл бұрын
If it's dead, then most likely it's a bad control board. This is not one I sell or repair.
@link128323 жыл бұрын
I have an Integra model INTEGRA FS recently replaced the auger motor it works but cant control the flow of the pellets anymore, it always seems to run as if on max feed and I cant control the feed anymore for regulated heat. Can you help?
@JASONRICHARDMunson3 жыл бұрын
Email me, support@pelletstovepro.org. with a number to reach you at. I may have some questions.
@jaysonray52423 жыл бұрын
I have a pel pro pp60 stove. Routine maintenance and cleaning. My auger switch broke so I jumped it... working great until kids knock jumper wire out and blew the fuse. I replaced the fuse with correct fuse and replaced the switch as well. Since said problems fixed my auger wants to run non stop and over fill the burn pot. What could be the cause of this? I'm thinking when said jumper wire came out and grounded it blew the fuse and part of the board. I can stand beside it and keep tripping the switch to turn on and off the pellet feed. All fans are kicking on in sequence and does great as long as I'm *manually * flipping the feed switch. But it I let it run on it's own its overfeeding..... should I get a new board ? I have tested the snap disc as well and it is working. Thanks in advance.
@JASONRICHARDMunson3 жыл бұрын
Yeah, the auger running continuously is classic bad control board. I think you need a new one.
@scottnelson4172 жыл бұрын
I have a 5824 ussc stove it's acting up the auger motor is only working on high and it times out after 15 mins seems like it's not sensing it's hot to keep it going
@playingwithfire20382 жыл бұрын
Time for a new auger motor.
@littlejorr4 жыл бұрын
Hey. I appreciate the video. I am a little confused on my Quadra-Fire Castile Insert. When I first plug in my cord, the lights come on but the exhaust fan won't. If the exhaust fan doesn't come on, nothing else will happen. its just dead. I get 15VAC at the fan. I jumpered the fan to the wall outlet and the fan works. I removed the control box and checked the incoming pins to the control box. There was one with 120VAC (others with odd voltages ranging from 4-9) from the cord but still had 9VAC at the fan with the control box out. This seems odd to me. I cannot find a wire diagram for my unit but I am thinking the fan should get 120VAC coming from the outlet to the control box to the fan. Do you know if that is how they are typically wired or where I can get a wiring diagram? Would you guess its the control box? Your help would be greatly appreciated.
@JASONRICHARDMunson4 жыл бұрын
I would start w/ the control box as you should be getting more than 15vac. You could still have a bad fan but without voltage from the box, nothing is going to work. We can fix your box...www.pelletstovepro.net/Repair-Service-for-ALL-Quadrafire-Pellet-Stove-Circuit-Board
@oplanetjanet6 жыл бұрын
Hi Jason, I am a widow with a massive problem on my hands. I have a Harmen Advance-2 Pellet stove, Bought in 2006. Tonight I heard what sounded like a circuit pop and my pellet stove completely shut down immediately. No slow down, like if it was shut off. Completely off in a matter of like 3 seconds. The outlet works , I tested it with my cellphone charger. I plugged it into the other outlet and still nothing. Checked my fuse box in the basement , all was good there. (actually reset my whole house to make sure) The pellet stove is my ONLY source of heat. I am Eastern Long Island , Ny , we have at LEAST 8 more weeks of winter. There is nothing on the status board lite up. Please help!!!!! Where I bought my stove , Rella Coal, is absolutely a nightmare to deal with when it comes to these type of things. I am so worried.
@doylee4695 жыл бұрын
oplanetjanet janet, if you are heading into next winter with the same pellet stove as your only source of heat then i reccomend watching as many youtube videos as you can. Find your exact model, then unscrew the back of your unit, and onserve the parts people are changing in there videos. You will feel more comfident. I really hope this winter is short and warm for ya dear... your post broke my damn heart
@jayheard76346 жыл бұрын
Hi Jason My Harmon Accentra II runs well in Stove mode but I get 4 blinks (indicating no thermostat is hooked up) in the Room mode. It has thermostat connected. When I connect the two connector contacts together with a jumper cable, I still get the 4 blinks and the stove will not start automatically. Sometimes I need to turn stove "on" twice to get it to light in Stove mode, but it will light. Could this be a board problem? Any Ideas?
@JASONRICHARDMunson6 жыл бұрын
I don't know that board very well so I would call Harmon on it. But if I would jumping out the thermostat I would be sure to do it right at the board and not at the end of the thermostat wires. I've had bad thermostat wires in the past cause this sort of problem.
@stephengibbons1845 жыл бұрын
Hi Jason, I have an Austroflamm integra and the auger light is just flashing quickly and the auger is not turning on. Read it could be the control board, just the EPROM, or the users control board. Anyway to trouble shoot which one may be bad? If I jumper the low temperature sensor, the combustion motor runs when the main switch is off. Any suggestions? Thanks
@JASONRICHARDMunson5 жыл бұрын
That is a bad control board. We can fix it ....www.pelletstovepro.net/austroflamm-pellet-integra-circuit-board--repair-service-product-730
@chrishill31684 жыл бұрын
User control board?
@bitchwilly53116 жыл бұрын
Hi Jason Munson I have a enviro Express Esspress fs pellet stove that is intermittently putting itself out this unit has a thermostat also self igniter option but is not installed
@JASONRICHARDMunson6 жыл бұрын
Tell me more. What do you mean by intermittently putting itself out? Can you tell me more specifically what happens?
@lawrenceklein35242 жыл бұрын
Heilsa QCPS 28000/Quality Craft Pellet Stove(s). I've looked high and low on the internet. All I have been able to find is a crappy Owner's Manual on PDF to download, and it is of no use at all. Does ANYONE out there know ANYTHING about these units?
@petersachs7645 жыл бұрын
So last year I bought a used England's 25-EPI and it ran fine for about 2 hours then it started popping fuses. I unplugged the auger motor and it did not pop a fuse. I removed the auger motor and connected it directly to a wall socket and the transformer on the motor assembly smoked itself. Since the motor is 120v A/C, I figured it must have been bad. I just installed a new motor and ran the stove successfully with a good flame for 2 hours. After the two hours I'm popping fuses all over again. Any ideas?
@playingwithfire20385 жыл бұрын
You have do the same basic process; start unplugging components until the fuse stops popping.
@petersachs7645 жыл бұрын
@@playingwithfire2038 But what if it's the control board itself popping the fuses?
@playingwithfire20385 жыл бұрын
@@petersachs764 That would be what you would replace if you unplug all the components and it's still popping the fuse.
@petergilleney16704 жыл бұрын
I have a Englander stove and the upper auger will not feed pellets? I bypass the vacuum switch still did not work? Is there something wrong with the board?
@JASONRICHARDMunson4 жыл бұрын
Try bypassing the hopper lid switch...
@petergilleney16704 жыл бұрын
That was the problem
@jackleydig2 жыл бұрын
My fan won’t stop running but my board won’t light up any idea what that would be?
@JASONRICHARDMunson2 жыл бұрын
If it's a Whitfield Control board that could be a bad control and maybe a bad low limit sensor.
@frankrongione67783 жыл бұрын
I noticed that my auger moter doesn't run all the time. It is very intermitten. I pulled the moter off of the whitfield stove and bench tested it. The moter workes and took approximately 54-56 seconds to make a complete rotation. I then checked the current runnint to the auger moter and found that when the feed light comes on the control board that there wasn't always power at the auger moter. The voltage was not constant when the light came on. What could be the problem? The control board?
@JASONRICHARDMunson3 жыл бұрын
How old is that auger motor? Sounds like it is going bad. This article has some other things to try...pelletstovepro.com/2012/11/my-auger-stopped/
@jessicasalcido12675 жыл бұрын
I have a pleasant hearth ph50cabps and the blower wont turn off only if I unplug it I bought a snap disc and that wasn't it any help?
@JASONRICHARDMunson5 жыл бұрын
There is more than one snap disc on your stove and if you didn't replace the low limit snap disc or if you put a high limit snap disc in the low limit spot then you're stove would do this. Try unplugging the stove and disconnecting the snap disc that is mounted to the exhaust fan. Make sure the wires don't touch any metal on the stove or you will ruin your control board. Plug it back it and trying running it. It should turn off within 15 mins. If it doesn't follow those two wires back to the control board and disconnect them. Run the stove again. If it still won't shut off you may have a bad control board.
@jessicasalcido12675 жыл бұрын
@@JASONRICHARDMunson thanks
@davidr38812 жыл бұрын
Hi Jason, I have a Harman XXV, distribution fan will not run on low speed. Turn it up past half and it starts to run, below half shuts down. Control board or distribution blower fan?
@captainthrob53442 жыл бұрын
I have the same stove, mine does the same, it appears the stove needs to get up to set temperature before blowing air so it’s not blowing cold air. Hope that helps
@davidr38812 жыл бұрын
So just to confirm, again it does blow on half and above with the stove running but when I lower it past half it shuts down and this is because the stove is not up to temp?? Think it would not run on high but run on low until the stove gets up to temp. So I don’t need a new Distribution blower?
@davidr38812 жыл бұрын
Just to add, the stove has been running for 3 days, 24 hrs a day. Still doing the same thing
@renukahbabyray4 жыл бұрын
I’ve noticed in the past few days my Austraflumm starts squeaking when it’s running. Anyone know why this is or how to stop it?
@JASONRICHARDMunson4 жыл бұрын
The bushing on your convection fan has gone bad. This is what you need....www.pelletstovepro.net/pre-2006-austroflamm-integra-pellet-convection-blower-w-mounting-bracket---riiz104551--104551-g-product-510
@gina43193 жыл бұрын
what size fuse sir
@terryjones83605 жыл бұрын
Mine won't shut down properly. When I shut it down, it keeps feeding pellets and gets hotter and hotter until I empty the pellet bin and it runs out of pellets. That's the only way to shut it down.
@JASONRICHARDMunson5 жыл бұрын
I need some more info to help you solve this problem. Email me at ebay@jasonRmunson.com with the above info along w/ the make and model of your stove.
@terryjones83605 жыл бұрын
@@JASONRICHARDMunson I'd rather just give it to you on here. It's a Vogelzang VG5770. I've been told it's the main board and costs $256 just for the board. I think I'll just install a switch on the power wire of the auger and shut the auger off when I shut down the stove. The schematics show the auger is directly controlled by the board.
@JASONRICHARDMunson5 жыл бұрын
Try disconnecting the low limit sensor. It's the round disc mounted to the exhaust fan with two wires going to it. With that disconnected it should shut off within 20 mins of startup.
@terryjones83605 жыл бұрын
@@JASONRICHARDMunson Yeah, I know the switch. I had to replace it a month ago or so. Kept giving me E-3 errors. There's always something wrong with this stove. I think it'll be easier to install a switch on the auger wire and turn it off when I turn off the stove. That' way I don't have to take the side cover off and pull the wire on the POF switch every time I want to shut it down. Thanks!!!
@randallclawson1182 жыл бұрын
What if the stove runs but you can't adjust it
@randallclawson1182 жыл бұрын
It is a england stove
@harrydoherty82993 жыл бұрын
my board feed light jump around by them selves . also the fan would come on cold at start up. also if i lightly tap on the board cover the stove acted erratic . the next morning there were no light coming on when i pushed the start button . i back probed the power and common terminals at the board connector and the power out of the controller . has power . fuse is good i believe the old rap test verifies a bad board
@JASONRICHARDMunson3 жыл бұрын
email me at support@pelletstovepro.org and let me know the make and model of your stove along with the problem you have.
@charleskohli1282 жыл бұрын
Why does my stove turn on but turn right off
@charleskohli1282 жыл бұрын
It's a England stove works
@milagrossmith48913 жыл бұрын
This video is verbally informative but you did not show anything physical to see exactly what this looks like for example bad fuses. We are DIY'rs not professionals. It would be nice to actually see you testing something or show to to replace a part so we can know how to do it and what to look for. Thanks
@isaacridenour11892 жыл бұрын
Profile 30 control board all lights blinking, nothing will run! Whitfield!
@mcross3203 жыл бұрын
Stupid owners manual doesn't identify the TWO FUSES! That's all it was! 6 amp on control panel, 8 amp main inline.
@stanwhite5270 Жыл бұрын
Jason, my pellet stove works great, until I turn it on lol. If I by pass the snap switch for the blower fan it works great, but as soon as I hook the switch up it turns off with red light flashing. Any suggestions
@pc54402 жыл бұрын
I sent you an email
@annadaly66682 жыл бұрын
Hi Jason, my pellet stove working fine but wont change pellet feed between 1 to 5 , It shows setting 5 when i set it through the control board but makes no difference to the feed of pellets, It just works away at the one speed , Just wondering is it the control board thats not working properly ? Just want it to feed more pellets for more heat. It's an ICB 22kw wood pellet boiler stove made in Barcelona, I do not have a manual for it. But other than that it works great without any problem, just need more pellet feed for more heat. Thanks for all your videos , so helpfull .