Hello to you all out there, I hope you enjoy this episode.
@stavracheandrei95803 ай бұрын
Great Video, thank you for sharing!
@TravelersWorld703 жыл бұрын
Such a Useful information onboard lng vessels.thanks Captain💛 for this Video.
@nickthesailorman3603 жыл бұрын
You are welcome Arnel thank you.
@abdelbakisofiane597415 күн бұрын
Thanks for this information about ESD .how about dable valves of amARMS loading
@socratescupra89773 жыл бұрын
Amazing video Captain keep going!!!
@nickthesailorman3603 жыл бұрын
Thank you Socrates appreciated.
@معتزالملاحي-ذ1مАй бұрын
Do you have strainer in the manifold ?
@wincros30643 жыл бұрын
Very good vedio. 👍👍👍
@forthegalacticempire47153 жыл бұрын
Hello capten Nick. I was wondering, in what emergency situation would someone use the emergency shut down system?
@nickthesailorman3603 жыл бұрын
Good day to you and hope you are doing well!!! Emergency situations are: Fire on board, Unsafe of Cargo Tank (Extremely High) and the Manual Shutdown.
@handokosuki17503 жыл бұрын
Hello Nick…thanks for This useful video..hope you Also make video that explain the process of LNG unloading in a discharging port
@nickthesailorman3603 жыл бұрын
Good day yes it is on schedule.
@ДмитрийЗеленцов-ф6р Жыл бұрын
Can you share electrical and pneumatic schematic drawings for ESD system?
@TheLibin282 жыл бұрын
hello Nick, I understand these are KM ESD systems onboard. Just wanted to know what is the pneumatic bypass wrong position indicator and electric wrong position indicator? When does it light?
@nickthesailorman360 Жыл бұрын
hello the system turn green when you use it
@vladnovikov27173 жыл бұрын
Thanks Nick Can you arrange a Cargo Compressor Room trip with your meticulousness?
@nickthesailorman3603 жыл бұрын
Well i Will do one in the future since now the only compressor room i can show you is my gardens pump for watering the plants.😀
@AnkitKumar-up1jr6 ай бұрын
Hi Nick Can you please answer the difference between HOT ESD test and Cold ESD test!!
@nickthesailorman3606 ай бұрын
@@AnkitKumar-up1jr hi Yes of course the warm esd test is when the cargo manifolds have not yet been cooled down.The cold esd test is when the manifolds and the associated pipings have been cooled down with liquid LNG.There is also the cold stroke test which is basically to see that the ESD valves are operating whilst they are cold.
@AnkitKumar-up1jr6 ай бұрын
@@nickthesailorman360 Thank you so much Nick!!🙏
@DimitriosPitsos-n2m3 ай бұрын
Is the ESD can be used only once? or can be reuse after the first time? Does anyone knows?
@nickthesailorman3603 ай бұрын
@@DimitriosPitsos-n2m Yes if you reset it and both sides are healthy then we can go ahead to establish communication of both shore and ship units.Then remove override and is ok to reuse it if there is an emergency.
@abdulwasi74112 жыл бұрын
hello Sir, just want to ask, what's that pneumatic for? is it pneumatic air for instrumentation (valves, etc) or what?
@nickthesailorman3602 жыл бұрын
Hello Abdul no this is another type of ESD system and I have came across with system as primary but mostly as back up.
@marinongpinas40523 жыл бұрын
Is it correct 48hrs of testing of ESD or 70hrs before
@nickthesailorman3603 жыл бұрын
Well we perform the within 48 hours prior cargo operations (loading-unloading).
@karimferrand84502 жыл бұрын
Nice manifold area that show high standard implemented on board;i wonder to know how old have this lady?. Question : if this test is conducted simultaneous for all valves witch valve you will calculate timing less than 30s because all valves will close at the same time ?
@nickthesailorman3602 жыл бұрын
Yes and yes she is a baby :) On your quesion kindly note that the ships ESD Liquid valves are the ones closing 4 Blue 1 Yellow
@kopaska1922 Жыл бұрын
sr , can u vidoe how to electric ESD working , thanks
@nickthesailorman360 Жыл бұрын
Will do so its exactly the same procedure of closing our valves, the system is electric.
@kopaska1922 Жыл бұрын
@@nickthesailorman360 Can U gift me videos, Line Electric ESD, i'am just corius. 😄
@budiharnawa613 Жыл бұрын
Thank you
@nyupnik3 жыл бұрын
Samsung 2274, "Gaslog Wales", eh? Stay safe!
@nickthesailorman3603 жыл бұрын
Thank you have a nice day.
@vladnovikov27173 жыл бұрын
What is the make (Manufacturer's brand) of your ESD valves?
@nickthesailorman3603 жыл бұрын
If I told you that I don't remember :)
@vladnovikov27173 жыл бұрын
No matter, mr Nick, I think this is Westad butterfly valve supplied with somewhat modified Scana quater-turn actuator. My business is training of tanker personnel, so can your videos be used as an educational stuff?